The EDGE EVO Door module is wired to interface with the EDGE EVO device (Hi-O Networked Controler & Reader or Networked
Controller) with electronic door components. Designed for providing interface to traditional discrete access inputs and outputs, the Door
Module provides four input analog/digital inputs and two outputs. Congure the Door Module in two ways; as a primary door interface to
REX, Door Position Switch, Battery Fail, Power Fail, Lock, and Aux (Group 1) or as a general purpose input/output module (Group 2).
Specifications
CONDITIONS
DC Input (NSC)
DC Input (MAX)
Input
Supervised inputs
(AC, Batt, REX, Door Mon) (MAX)
Strike *** /
AUX
NC or NO
DC Output
Output
(MAX)
AUX 12 VDC
Input @
Controller
AUX 24VDC
Input @
Controller
PoE Input @
Controller
AUX 12-24 VDC
/ PoE Input @
Controller
NSC = Normal Standby Condition ** Each Relay
* Combined output rating not to exceed V*I = W *** Shared between relays
1.2 Amp (+24 VDC AUX Input, 28.8 W)
1.2 Amp (+12 VDC AUX Input, 12.96 W)
Unregulated (Wet)
Jumpers
Unregulated (Wet)
Jumpers
Regulated (Wet)
Jumpers – 12 VDC
Unregulated (Wet)
Jumpers
Regulated (Wet)
Jumpers – 12 VDC
Jumpers Set to Dry
VOLTAGE DC
(VDC)
+12 VDC 0.04 Amp 0.48
+24 VDC 0.04 Amp 0.96
+12 VDC 0.80 Amp 9.6
+24 VDC 0.80 Amp 19.2
0-5 VDC
Reference
+10 to +12 VDC 0.70 Amp* 8.40
+23 to +24 VDC 0.70 Amp* 16.80
+10 to +12 VDC 0.70 Amp* 8.40
+16.5 to 24 VDC 0.30 Amp* 7.2
+10 to +12 VDC 0.50 Amp* 6.0
+12 to 24 VDC
External
CURRENT
(Amp)
0.005 Amp
(Sink)
2.00 Amp** 24.00
POWER
(W)
0.025
OPERATING
TEMPERTURE
32° - 122°F
(0° - 50° C)
CABLE LENGTH
Inputs = 500 ft (150 m)
Outputs = 500 ft (150 m)
Hi-O CAN Bus Total Length 100 ft (30 m) -
22 AWG ● 0.65mm ● 0.33mm
Maximum between drops 30 ft (10 m)
22 AWG ● 0.65mm ● 0.33mm2
Door Module
EDM-M
InstallatIon GuIde
82342-901, Rev C.1
December 2012
UL REF
NUMBER
MEDMAxNN
2
x = K for Black
G for Grey
®
Door Module
EDM-M
Wiring
Short = Group 1, Open = Group 2
( )
Outside Door Inside Door
Optional
Supervised Inputs
1-6K
1-6K
1-6K
N/O
N/C
Relay Jumpers
P9
P5
P8
P6
P4
P7
10 P3 14 P1 1
-+
-+-+-+
REX
BATT AC
SENSE
Door
Mon
6 P10 1
NO
*
COM
AUX
NC
NO
DS
NC
COM
* Internal Optical Tamper Disable Jumper
82342-901 C.1
CAN V+
GND
CAN H
CAN L
HI-O CANbus
1-6K
N/O
CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break
voltage when de-energized due to magnetic eld collapse. It is recommended you use of a snubber circuit
across the controlling relay terminals to protect the controlling relay contacts. Go to support.hidglobal.
com, see Solution 891 - How do I wire a High In-Rush Current locking device to VertX/EDGE EVO.
Not evaluated by UL.
Note: Connect the Door Monitor to avoid a Door Forced Alarm.
Internal Optical Tamper
To disable the internal optical tamper sensor, attach a jumper wire from P3 pin 1 to P3 pin 2.
Note: If desiring an external tamper, wire an unsupervised Normally Closed contact to the Optical Tamper pins.
Relay Jumpers
AUX Wet
CAN V+
3 1
3 13 1 3 1
AUX Wet
+12VDC
AUX Dry
P9
P5
DS Wet
CAN V+
DS Wet
+12VDC
3 13 1
DS Dry
P6
P4
INSTALLATION GUIDE
2
JUMPER =
P8
P7
©2009 - 2012 HID Global Corporation. All rights reserved.