The EDGE EVO Door module is wired to interface with the EDGE EVO device (Hi-O Networked Controler & Reader or Networked
Controller) with electronic door components. Designed for providing interface to traditional discrete access inputs and outputs, the Door
Module provides four input analog/digital inputs and two outputs. Congure the Door Module in two ways; as a primary door interface to
REX, Door Position Switch, Battery Fail, Power Fail, Lock, and Aux (Group 1) or as a general purpose input/output module (Group 2).
Specifications
CONDITIONS
DC Input (NSC)
DC Input (MAX)
Input
Supervised inputs
(AC, Batt, REX, Door Mon) (MAX)
Strike *** /
AUX
NC or NO
DC Output
Output
(MAX)
AUX 12 VDC
Input @
Controller
AUX 24VDC
Input @
Controller
PoE Input @
Controller
AUX 12-24 VDC
/ PoE Input @
Controller
NSC = Normal Standby Condition ** Each Relay
* Combined output rating not to exceed V*I = W *** Shared between relays
1.2 Amp (+24 VDC AUX Input, 28.8 W)
1.2 Amp (+12 VDC AUX Input, 12.96 W)
Unregulated (Wet)
Jumpers
Unregulated (Wet)
Jumpers
Regulated (Wet)
Jumpers – 12 VDC
Unregulated (Wet)
Jumpers
Regulated (Wet)
Jumpers – 12 VDC
Jumpers Set to Dry
VOLTAGE DC
(VDC)
+12 VDC 0.04 Amp 0.48
+24 VDC 0.04 Amp 0.96
+12 VDC 0.80 Amp 9.6
+24 VDC 0.80 Amp 19.2
0-5 VDC
Reference
+10 to +12 VDC 0.70 Amp* 8.40
+23 to +24 VDC 0.70 Amp* 16.80
+10 to +12 VDC 0.70 Amp* 8.40
+16.5 to 24 VDC 0.30 Amp* 7.2
+10 to +12 VDC 0.50 Amp* 6.0
+12 to 24 VDC
External
CURRENT
(Amp)
0.005 Amp
(Sink)
2.00 Amp** 24.00
POWER
(W)
0.025
OPERATING
TEMPERTURE
32° - 122°F
(0° - 50° C)
CABLE LENGTH
Inputs = 500 ft (150 m)
Outputs = 500 ft (150 m)
Hi-O CAN Bus Total Length 100 ft (30 m) -
22 AWG ● 0.65mm ● 0.33mm
Maximum between drops 30 ft (10 m)
22 AWG ● 0.65mm ● 0.33mm2
Door Module
EDM-M
InstallatIon GuIde
82342-901, Rev C.1
December 2012
UL REF
NUMBER
MEDMAxNN
2
x = K for Black
G for Grey
®

Door Module
EDM-M
Wiring
Short = Group 1, Open = Group 2
( )
Outside Door Inside Door
Optional
Supervised Inputs
1-6K
1-6K
1-6K
N/O
N/C
Relay Jumpers
P9
P5
P8
P6
P4
P7
10 P3 14 P1 1
-+
-+-+-+
REX
BATT AC
SENSE
Door
Mon
6 P10 1
NO
*
COM
AUX
NC
NO
DS
NC
COM
* Internal Optical Tamper Disable Jumper
82342-901 C.1
CAN V+
GND
CAN H
CAN L
HI-O CANbus
1-6K
N/O
CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break
voltage when de-energized due to magnetic eld collapse. It is recommended you use of a snubber circuit
across the controlling relay terminals to protect the controlling relay contacts. Go to support.hidglobal.
com, see Solution 891 - How do I wire a High In-Rush Current locking device to VertX/EDGE EVO.
Not evaluated by UL.
Note: Connect the Door Monitor to avoid a Door Forced Alarm.
Internal Optical Tamper
To disable the internal optical tamper sensor, attach a jumper wire from P3 pin 1 to P3 pin 2.
Note: If desiring an external tamper, wire an unsupervised Normally Closed contact to the Optical Tamper pins.
Relay Jumpers
AUX Wet
CAN V+
3 1
3 13 1 3 1
AUX Wet
+12VDC
AUX Dry
P9
P5
DS Wet
CAN V+
DS Wet
+12VDC
3 13 1
DS Dry
P6
P4
INSTALLATION GUIDE
2
JUMPER =
P8
P7
©2009 - 2012 HID Global Corporation. All rights reserved.

82342-901 C.1
Door Interface Board Groups 1 and 2
Group 1
Following are the inputs when the unit is congured for Group 1.
Input Port Pin
AC - P3 Pin3
AC + P3 Pin 4
BATT - P3 Pin 5
BATT + P3 Pin 6
REX - P3 Pin 7
REX + P3 Pin 8
Door Mon - P3 Pin 9
Door Mon + P3 Pin 10
Group 2
Following are the inputs when the unit is congured for Group 2.
Input Port Pin
Input 4 - P3 Pin3
Input 4 + P3 Pin 4
Input 3 - P3 Pin 5
Input 3 + P3 Pin 6
Input 2 - P3 Pin 7
Input 2 + P3 Pin 8
Input 1 - P3 Pin 9
Input 1 + P3 Pin 10
Door Module
EDM-M
©2009 - 2012 HID Global Corporation. All rights reserved.
INSTALLATION GUIDE
3

Regulatory
UL
Connect only to a Listed Access Control / Burglary power-limited power supply, or Listed Access Control / Burglary PoE (Power-over-Ethernet) adapter.
All National and local Electrical codes apply. Install in accordance with NFPA70 (NEC), Local Codes, and authorities having jurisdiction.
Indoor use only.
EDGE EVO Modules are UL Listed for installation within a protected area.
Mount onto UL Listed Single-Gang electrical box.
All panic and alarm hardware and equipment shall be UL Listed.
All cabling and wire shall be UL Listed or Recognized and suitable for the application.
All splices and connections shall be mechanically secure and bonded electrically.
For operation, testing and maintenance, refer to the Hi-O Network Controller & Reader (82000-922) and Hi-O Networked Controller Installation Guides (82000-920).
CAUTION: Any changes or modifcations to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes
: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
CE MARKING
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The controller portion is in compliance with the essential requirements and other relevant provision of Directive 2004/108/EC.
JAPAN MIC
この装置は認証済みです。
TAIWAN NCC
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。低功率射頻電機之使用不得
影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功
率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
According to «Administrative Regulations on Low Power Radio Waves Radiated Devices» without permission granted by the NCC, any company, enterprise, or user is not allowed
to change frequency, enhance transmitting power or alter original characteristic as well as performance to an approved low power radio-frequency devices. The low power radiofrequency devices shall not inuence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved.
The said legal communications means radio communications is operated in compliance with the Telecommunications Act.
The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.
ACCESS experience.
© 2009 - 2012 HID Global Corporation. All rights reserved.
Check reader label for current regulatory approvals.
hidglobal.com
82342-901 Rev C.1
Patent Pending
HID Global
North America
15370 Barranca Parkway
Irvine, CA 92618
USA
Phone: 800 237 7769
Fax: 949 732 2120
Asia Pacific
19/F 625 King’s Road
NorthPoint, Island East
Hong Kong
Phone: 852 3160 9800
Fax: 852 3160 4809
support.hidglobal.com
HID GLOBAL, HID, the HID logo, EDGE EVO and Hi-O are the trademarks or registered
trademarks of HID Global Corporation, or its licensors, in the U.S. and other countries.
Europe, Middle East & Africa
Phoenix Road
Haverhill, Suolk CB9 7AE
England
Phone: +44 1440 714 850
Fax: +44 1440 714 840