Hewlett-Packard 2000 SA G2 User Manual

QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array

Overview

The HP StorageWorks 2000sa G2 Modular Smart Array is a 3Gb SAS direct attach, external shared storage solution that helps customers easily transition from direct attached to centralized storage. It allows departmental and small to medium businesses customers to grow capacity as demands increase up to 29.7 TB SAS or 60 TB SATA, and supporting up to 64 hosts
With up to 511 LUNs and LUN sizes up to 16 TB, the MSA2000sa G2 gives maximum configuration flexibility. The MSA2000sa G2 allows mixing of enterprise-class, dual-ported SAS drives and archival-class SATA drives, and supports both Large Form Factor and Small Form Factor drives. The optional HP StorageWorks 2000 Modular Smart Array Snapshot Software offers increased data protection. The MSA2000sa G2 can be configured with a single controller for a low initial price with future expansion, or with dual controller for situations that require higher availability and performance for the most demanding entry-level situations.
What's New
New SAS controller with four SAS host ports Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch Support for Small Form Factor (SFF) SAS and SATA drives, common with ProLiant Support for attachment of THREE dual I/O MSA70 SFF JBODs (total ninety-nine SFF drives) Increased support to FOUR MSA2000 LFF disk enclosures with the MSA2012 Chassis (sixty LFF drives) Support for new Small Form Factor 300 GB SAS drive - doubling the SFF SAS capacity Increased optional snapshot capability to 255 snaps Additional LUN support up to 511 total volumes in a Dual Controller system Availability of a carrier grade NEBS-certified DC-powered MSA2024 SFF chassis
HP StorageWorks 2024 G2 Modular Smart Array
HP StorageWorks 2012 G2 Modular Smart Array
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 1
QuickSpecs

Models

Models
HP StorageWorks 2000sa G2 Modular Smart Array
Controller-less CHASSIS & MSA2300sa G2 Controller
HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) (Will accept one or two controllers or Disk Enclosure I/O modules)
HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) (Will accept one or two controllers)
HP StorageWorks 2300sa G2 Modular Smart Array Controller
Disk Enclosures
HP StorageWorks MSA2000 Single I/O 3.5-inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with single controller array head
HP StorageWorks MSA2000 Dual I/O 3.5-inch inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables) Used with dual controller array head
HP StorageWorks MSA2000 Drive Enclosure I/O Module (no cable included)
HP StorageWorks MSA70 2.5-inch 25 SFF Drive Enclosure 2.5 in Drive Enclosure (single I/O, single domain) (w/one .5m miniSAS to miniSAS cable)
HP StorageWorks Dual Domain I/O Module for MSA70 enclosure (upgrades MSA70 to dual domain) (w/ one .5m miniSAS to miniSAS cable)
Configured Units
HP StorageWorks 2312sa G2 Dual Controller Modular Smart Array (LFF)
HP StorageWorks 2324sa G2 Dual Controller Modular Smart Array (SFF)
Controller-less Chassis: DC-powered units
HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) (can add one or two MSA2300sa G2 controllers or MSA2000 JBOD I/O modules)
HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) (can add one or two MSA2300sa G2 controllers. No MSA2000 JBOD I/O module support)
Controller-less Carrier Grade Chassis
HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis (SFF)
Related Option
HP StorageWorks 2000sa Modular Smart Array Controller (limited use) (for use only with an AJ948A LFF chassis for those needing to configure an older MSA2012sa. Only supports older features, functionalities. No SFF or MSA70 JBOD support, max 48 LFF drives, max 64 snaps)
HP StorageWorks 2000sa G2 Modular Smart Array
AJ948A
AJ949A
AJ808A
AJ749A
AJ750A
AJ751A
418800-B21
AG779A
AJ805A
AJ807A
AJ950A
AJ951A
AM337A
AJ754A
Related Items
MSA2324sa G2 DL380 G6 Package Cluster
MSA2000sa Switch Bundle
HP StorageWorks 2324sa G2 Modular Smart Array DL380 G6 Package Cluster
NOTE:
The HP MSA2324sa G2 DL380 G6 Package Cluster Bundle contains the following components: One MSA2324sa G2 Dual-controller array; Two DL380 G6 Servers Four HBAs Four SAS cables Snapshot software 8 LTU (
NOTE:
This bundle is available worldwide except APJ and Brazil)
HP StorageWorks 2000sa Modular Smart Array 3Gb SAS BL Switch Bundle
NOTE:
The HP MSA2000sa 3Gb SAS BL Switch Bundle contains the following components:
HP MSA2012sa DC Modular Smart Array (Qty 1)
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
AP813A
AP716A
Page 2
QuickSpecs
Models
HP 3Gb SAS BL Switches (Qty 2) HP mini-SAS 2M Cable (Qty 4)
NOTE:
This bundle includes original MSA2000sa controllers
3Gb SAS Switch
Blade Mezzanine Module
HP StorageWorks 3Gb SAS BL Switch (CTO Only)
HP StorageWorks 3Gb SAS BL Switch - Dual Pack
Configuration Rules
The SAS Switch is supported only in the HP c-Class Enclosures (C7000 &
1. C3000) The switch is placed into an interconnect bay in the back of the c-Class
2. Enclosure chassis. C7000 chassis has 6 interconnect bays for switches & C3000 chassis has 3 interconnect bays for switches, however for this solution we will only support the use of 4 interconnect bays in the C7000 and 2 interconnect bays in the C3000. (2) SAS Switches are required in the same c-Class enclosure
3. interconnect bay row. For the C3000 enclosure, the SAS Switch can only be placed into
4. interconnect bays (3 and 4) For the C7000 enclosure, the SAS Switch can only be placed into
5. interconnect bays (3 and 4), or (5 and 6) or (7 and 8). The preferred interconnect bays are (5 and 6) then (7 and 8). For the C3000 enclosure, using a server's mezzanine slot 1 along with
6. enclosure interconnect bay 2 is not supported.
HP Smart Array P700m Controller/256BBWC Controller
HP Smart Array P700m Controller/512 BBWC Controller
Battery Kit
Configuration Rules
HP StorageWorks 2000sa G2 Modular Smart Array
AJ864A
AJ865A
:
507925-B21
508226-B21
452348-B21
:
A half height blade server must have a P700m (508226-B21 or 507925-
1. B21) installed in server mezzanine slot 1 or mezzanine slot 2. The preferred mezzanine slot is slot 2. A full height blade server must have a P700m 508226-B21 or 507925-
2. B21) installed in server mezzanine slot 1, mezzanine slot 2 or mezzanine slot 3. The preferred mezzanine slot is slot 2. A double density blade server must have a P700m (508226-B21 or
3. 507925-B21) installed in server mezzanine slot 2 of each server. 4 SAS Switches, in interconnect bays 5, 6, 7 and 8, must also be included in this configuration.
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 3
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array

Features and Benefits

Key Hardware Features
Highly efficient consolidation and sharing of storage geared to departmental and small to medium business requirements Cost efficient plus high-availability choices Flexibility in drives: LFF MSA2 3.5-inch or HP ProLiant SFF 2.5-inch drives Enterprise-class SAS or archival-class SATA drives as the need and budget dictates Dual-ported SAS drives for enterprise needs Large capacity SATA drives for inexpensive archival storage Able to mix SAS and SATA drives within the same drive enclosure Choose either single or dual controller array models to fit the budget Choice of low cost single I/O or high-availability dual I/O drive enclosure models
Customer Benefits
The HP StorageWorks 2000 Modular Smart Array family manages growing storage requirements across multiple HP ProLiant servers for customers who need a centralized dedicated storage solution for applications. Shared storage allows for controlled, cost-effective growth and increased protection of data. Its ease of management allows a department or small company to effectively handle growing storage requirements with a minimum of complexity. The MSA2000sa G2 extends the benefits of shared storage resources to first time implementers on a tight budget Depending on the model chosen, the modular design allows the user to start relatively small but supports future growth to hundreds of users and up to 27 TB of LFF SAS or 60 TB of LFF SATA storage, or 29.7 TB of SFF SAS or
24.7 TB of SFF SATA storage. The optional controller-based snapshot and clone capability as part of the MSA2000 family allows the smaller departmental user or company to implement functionality once only available to much larger firms with expensive arrays.
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 4
QuickSpecs
HP StorageWorks 2000sa G2 Modular Smart Array

At a Glance

HP MSA2000sa G2 At a Glance:
High performance Modular Smart Array controller with four 3Gb SAS ports per controller Single and dual controller capability 1 GB transportable cache per controller - battery-free cache backup with super capacitors and compact flash 511 LUNs with 16TB LUNs supported 2U rack mount chassis combining both the controller and disk shelf Twelve 3.5 inch dual-ported SAS or SATA MSA2000-specific drives (supports mixing of drive types in a single shelf) Twenty-four 2.5 inch dual-ported SAS or SATA ProLiant drives (also supports mixing of drive types in a single shelf) Support expansion to 4 additional enclosures & total of 48 disk drives Supports expansion to 3 additional SFF enclosures (MSA70) for a maximum total of 99 SFF disks Redundant power supplies and fans are standard RAID levels 0, 1, 3, 5, 6, 10, 50 Non-disruptive on-line controller code upgrade Heterogeneous support for 32-bit and 64-bit Windows, Red Hat and SuSE Linux Windows Server 2008 x64 Hyper-V, VMware, RedHat Enterprise Linux Virtualization, and Citrix XenServer Qualified and certified for Windows, Linux and Solaris clustering Optional controller-based snapshot and clone functionality
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 5
QuickSpecs

Family Information

HP StorageWorks 2000sa G2 Modular Smart Array
Capacity
Minimum / with maximum additional drive enclosures
Controller Cache
Total LUNs
Host connect
MSA2000 has 1 or 2 controllers, EVA has 2 controllers standard
Maximum Drives
w/ expansion
Maximum host supported
Snapshot, remote replication
Use for Storage
*maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of LUNs and LUN size ** Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch
(raw)
MSA2000sa G2
LFF:
SFF:
1 GB per controller 1 GB per controller 1 GB per controller
Primary Storage with SAS
Secondary with SATA
5.4 TB SAS
or 12 TB SATA
w/ 4 drive enclosures:
27 TB SAS
or 60 TB SATA
7.2 TB SAS
or 6.0 TB SATA
w/ 3 MSA70 JBODs:
29.7 TB SAS
or 24.7 TB SATA
511 512 512
Four 3Gb
SAS ports
per controller
60 LFF/99 SFF 60 LFF/99 SFF 60 LFF/99 SFF
64
**
Snapshot, clone Snapshot, clone Snapshot, clone
MSA2000fc G2
LFF:
SFF:
Fibre Channel ports
Primary Storage with SAS
Secondary with SATA
5.4 TB SAS
or 12 TB SATA
w/ 4 drive enclosures:
27 TB SAS
or 60 TB SATA
7.2 TB SAS
or 6.0 TB SATA
w/ 3 MSA70 JBODs:
29.7 TB SAS
or 24.7 TB SATA
Two 4Gb
per controller
64 32
MSA2000i G2
LFF:
or 12 TB SATA
w/ 4 drive enclosures:
or 60 TB SATA
SFF:
or 6.0 TB SATA
w/ 3 MSA70 JBODs:
29.7 TB SAS
or 24.7 TB SATA
Two 1GbE
iSCSI ports
per controller
Primary Storage with SAS
Secondary with SATA
5.4 TB SAS
27 TB SAS
7.2 TB SAS
Product Technology
SAS
Modular Chassis
Drives available
Four 3Gb host ports per controller
2U rack height. 12 Large Form Factor or 24 Small Form Factor drive bays, accommodating SAS and SATA. Comes with space for one or two controllers, or MSA2000 3.5-inch disk Enclosure I/O modules (LFF chassis only).
The new MSA2300sa G2 controller supports both the MSA2 3.5-inch Large Form Factor (LFF) drives, or the HP ProLiant 2.5-inch Small Form Factor (SFF) drive
Serial Attached SCSI (SAS) enterprise-class drives designed for high volume, 24x7 usage. Serial-ATA (SATA) are usually reserved for archival of data as they are both relatively inexpensive and are available in very large capacities. The MSA2000 family of arrays can accommodate both SAS and SATA drives within the same enclosure making it ideal to have both business-critical, high activity files on SAS drives while using snapshot or clone capability to keep back-up data on the less expensive drives.
For investment protection, the MSA2300sa G2 controller will support single port SAS & SATA drives in a single-domain MSA70. This support allows current owners of MSA70s to migrate their single port drives (in their MSA70 only) to be attached to an MSA2000sa G2. They can only cascade to another single I/O MSA70. This is not a data-in-place transition.
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 6
QuickSpecs
Family Information
Optional Disk enclosures
HP StorageWorks 2000sa G2 Modular Smart Array
SAS drive performance can be approximately 30% greater than SATA performance on sequential host IO. SAS performance excels in sequential lower latency response time and random IO per second transaction performance due to higher rpm disk speeds yielding lower seek times.
NOTE:
MSA2 3.5" Large Form Factor (LFF) drives are for use only in
the MSA2000 family.
Just as the user has a choice of chassis for the array head (LFF and SFF drive bays), so also do they have a choice of expansion disk enclosures accommodating either drive size. (NOTE: these are not supported as part of a NEBS-certified with the MSA Carrier Grade Chassis.)
MSA2000 3.5-inch drive enclosure
inch) drive bays and accepts for MSA2 dual-ported SAS and SATA drives. One model (AJ749A) has a single I/O module that matches with a single controller array head, giving a single path to the drives. The second model (AJ750A) comes standard with two I/O modules installed, required when paired with a dual controller array head, giving two paths to the drives for higher availability.
. This 2U unit has twelve LFF (3.5-
Scalability
This 3.5-inch drive enclosure can be attached to either the LFF or SFF MSA2000sa G2 array head. Each model ships standard with two .6m SAS to SAS cables for cascading to other MSA2000 drive enclosures For connection to either form-factor MSA2300sa array head, miniSAS to SAS cable(s) must be purchased. The single I/O model can be upgraded to a dual model with the purchase of an additional MSA2000 Drive Enclosure I/O module (AJ751A). No cable is included with this upgrade. Up to four MSA2000 3.5-inch enclosures can be attached to an MSA2300i controller in the array head.
MSA70 2.5-inch drive enclosure
B21) is designed to support twenty five ProLiant 2.5-inch Universal form factor (SFF) SAS or SATA hard drives. It ships standard with a single I/O module installed.
This 2.5-inch drive enclosure can be attached behind either LFF or SFF MSA2000sa G2 Array head. The MSA70 enclosure ships with a single .5m miniSAS to miniSAS cable. To support a dual controller MSA2000sa G2 array head, the user needs to purchase and install an MSA70 Dual Domain I/O Module (AG779A). This option ships standard with an additional .5m miniSAS to miniSAS cable. Up to three MSA70s may be attached to the array head, given total support for 99 SFF drives.
The MSA2300sa G2 controller is designed to allow an installation to begin with smaller capacity and be able to grow gradually as needed. The flexibility of SAS or SATA drive technology, form factors, sizes, speeds, and costs per GB allows a system to easily fit in almost any budget.
. This 2U storage enclosure (418800-
Large Form Factor configurations can scale up to 5.4 TB SAS or 12 TB SATA, expandable to 27 TB SAS or 60 TB SATA with the addition of a maximum of four MSA2000 3.5-inch Drive Enclosures. Small Form Factor configurations can scale from 7.2 TB SAS or
6.0 TB SATA. With the addition of three MSA70 JBODs, the MSA2000sa G2 can support 29.7 TB SAS or 24.7 TB SATA.
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009
Page 7
QuickSpecs
Family Information
LUNs
RAID 0, 1, 3, 5, 6, 10, 50
Configuration and Management Tools
Hot Plug Expansion and Replacement Support
Snapshot and Clone
Performance
Workload
Host Connect
MSA2000 RAID 10 Performance Results (rounded)
Random Reads IOPs
Random Writes IOPs
Random Mix IOPs 60/40 read/write
Sequential Reads MB
Sequential Writes MBs
MSA2000 RAID 5 Performance Results (rounded)
Random Reads IOPs
Random Writes IOPs
Sequential Reads MBs
Sequential Writes MBs
HP StorageWorks 2000sa G2 Modular Smart Array
Users may configure a 24-drive MSA2000sa G2 SFF array head with up to three 12-drive LFF MSA2000 3.5-inch disk enclosures. This is an excellent method for a configuration that support fast SFF enterprise-class SAS drives in the array head, combined with economical LFF drives staged for archival purposes, all in the same array.
Qualification of larger capacity drives is ongoing.
The MSA2000 family of arrays supports 511 LUNs and LUN sizes up to 16TB. The arrays support LUN expansion and deletion of any LUN.
In addition to the usual RAID levels, the MSA2000 family features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes.
HP StorageWorks MSA Storage Management Utility (SMU), Management access, out-of-band: WEB GUI, CLI. Interface Types: Mini DB9 RS232, 10/100 Ethernet Protocols Supported SNMP, SSL, SSH, SMTP, HTTP, Telnet.
The MSA2000sa G2 supports hot plug expansion and replacement of redundant controllers, fans, power supplies, and I/O modules for simple, fast installation and maintenance.
Optional controller based functionality. Offers higher levels of data protection, enabling an almost instant recovery from data failure or corruption. Offers alternative development testing of 'offline' production data and the ability to backup snapped/cloned data.
Performance numbers are a guideline as established by tests using RAW I/O in an Operating System Agnostic test lab environment. A total of 96 72GB 15K SAS drives were used in a dual controller configuration of eight 12 Disk vdisks, eight 806 GB volumes, and two volumes per host. Four hosts directly attached to the MSA2000sa G2 were used in this test configuration (results cannot be expected with a single host). Results were achieved in Sequential Writes with 256K blocks; all random test were based on 8K block sizes. Number and type of applications, drive type, operating system used, and the number of hosts will affect overall performance.
MSA2300sa G2
3Gb SAS
21861
14491
17700
1049
531
21019
2705
1051
644
DA - 13331 Worldwide QuickSpecs — Version 2 — 7.31.2009