hestan HFT, HCM Owner's Manual

1
Owner’s Guide
Installation & Operation
HFT Series
RETAIN THIS MANUAL FOR FUTURE REFERENCE
©2015 Hestan Commercial Corporation
Hestan Commercial Corporation
3375 E. La Palma Ave
Anaheim, CA 92806
(888) 905-7463
P/N 002131 REV 1
2
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT… …….
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
FOR YOUR SAFETY … …….
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WARNING …….
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE.
©2015 Hestan Commercial Corporation
3
Table of Contents
Section 1: Installation ............................................................................................... 4
Installation Procedure ..........................................................................................4
Uncrating ........................................................................................................4
Location ..........................................................................................................4
Clearances .......................................................................................................4
Placing Appliance ............................................................................................4
Leveling ...........................................................................................................4
Riser Installation ..............................................................................................5
Statutory Regulations .........................................................................................5
United States of America .................................................................................5
Canada ...........................................................................................................5
Gas Supply ............................................................................................................6
Gas Pressure Regulator ....................................................................................7
Ventilation Air / Flue Connections ...................................................................7
Electrical Supply .............................................................................................8
Model / Serial / Rating Plate Location ..............................................................8
Section 2: Operating Instructions .............................................................................. 9
Lighting and Shutdown Instructions .................................................................9
Section 3: Cleaning and Maintenance ...................................................................... 10
Gas-Fired Appliances ..................................................................................... 10
Service
Troubleshooting Guide .................................................................................. 11
.............................................................................................. 11
©2015 Hestan Commercial Corporation
4
Installation
COMBUSTIBLE
NON-COMBUSTIBLE
Model
BACK
SIDE
BACK
SIDE
French Top
4”
4”
0”
0
Installation Procedure
Uncrating
Check the crate for any possible damage sustained during transit. Carefully remove the appliance, removing all packing material, again check for damage. Any damage to the appliance must be reported to the carrier immediately.
Location
Proper placement of the appliance will ensure operator convenience and satisfactory performance. Adequate clearance must be maintained so that the combustion and ventilation air is not obstructed for proper operation. A minimum front clearance of 36 inches (914 mm) must be provided for servicing. The appliance must be kept free and clear of combustible materials.
Clearances
The following minimum clearances must be followed:
NOTE: For use on non-combustible counters or bases only.
Placing Appliance
Place the appliance in the required position and level by means of the adjustable legs. The surface on which the appliance is to be installed must be capable of adequately supporting the weight of the appliance.
Leveling
For proper and safe operation, each appliance must be level. Counter units must be installed on a non­combustible surface only.
4” legs are mounted using four hex-head bolts per leg and each leg is adjustable simply by turning the inner cylinder leg, clockwise to lower and counter-clockwise to elevate.
NOTE: A carpenter’s level can be used on the plate shelf for left to right leveling.
©2015 Hestan Commercial Corporation