Herkules 314-KIT-01 User Manual

Part # 1000557 4-17-00 4TN
OWNERS MANUAL
Black Pump
Rebuild Kit* 314-KIT-01 314-KIT-02 314-KIT-03 Rebuilt Pump 314W
Pump 314
*Note: An experienced person can rebuild a pump in an estimated 45 minutes. An inexperienced person can rebuild a pump in an estimated 2.5 hours
314 PUMP
OPERATOR'S MANUAL PD02P-X
X
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 10-1-96
REVISED: 11-5-99 (REV. E)
1/4" DIAPHRAGM PUMP
1:1 RATIO (NON-METALLIC)
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
SERVICE KITS
Refer to Service Kit Chart to match pump material with Service Kits offered. The "X" represents a variable digit of the Model Number. 637273–XXX for Pump Rebuild (model digits 7, 8, 9). 637274-XX for Check Valve Replacement (model digits 7, 9). 637275-XX for Diaphragm and Air Section repair (model digits 8, 9).
637276 for Pre-assembled Replacement Air valve section (fig.2).
PUMP DATA
Models………. See "Model Description Chart” for "-XXX”.
Pump Type….. Non-Metallic Air Operated Double Diaphragm. Material……… See Model Description Chart. Weight……….. Polypropylene……….. 4.08 lbs (1.85 kgs) Groundable Ac etal ….. 4.64 lbs (2.1 0 kgs) PVDF (Kynar)………… 4.9 lbs (2.22 kgs) Maximum Air Inlet Pressure…………… 100 p.s.i.g. (6.9 bar) Minimum Air Inlet Pressure…………… 20 p.s.i.g. (1.4 bar) Maximum Outlet Pressure…………….. 100 p.s.i.g. (6.9 bar) Maximum Flow Rate……………………. 4.6 g.p.m. (17.4 liters) Maximum Suction Lift …………………. 20 ft. (water) Maximum Output Per Cycle…………… 0.014 gallons (53 cc's) Maximum Particle Size…………………. 1/32" dia. (.79 mm) Maximum Temperature Limits Polypropylene………… 350 to 1500 F (20 to 660 C) Groundable Acetal…… 100 to 1800 F (-120 to 820 C) PVDF (Kynar)………… 10' to 2000 F (-120 to 93- C) Groundable……………………………. PD02P-XDS-DTX models only. Dimensional Data………………………… See page 8.
Noise Level @ 70 p.s.i. 60 c.p.m………. 59.8 db(A)
The pump sound pressure levels published here have been updated to an Equivalent Continuous Sound Level to meet the intent of ANSI S1.13-1971,CAGI-PNEUROP S5.1using four microphone locations.
1
NOTICE: All possible options are shown in the chart. However, certain combinations may not be recommended, consult a representative or the factory if you have questions concerning availability.
CENTER BODY MATERIAL
Polypropylene
P -
INLET / OUTLET
Single Inlet / Single Outlet
A ­D - Single Inlet / Double Outlet E - Double Inlet / Single Outlet H - Double Inlet / Double Outlet
WET END / FLUID CAP / MANIFOLD MATERIAL
D - Gr
PVDF (Kynar)
K -
Polypropylene
P -
GENERAL DESCRIPTION The Diaphragm Pump offers high volume delivery even at low air
pressures easy self priming, the ability to pump various viscosity
materials and the ability to pass solids (as stated in the chart above).
The pump is designed to correspond to the needs of the user by offering
a variety of wetted parts configurations to handle almost any application. Air operated double diaphragm pumps utilize a pressure differential in
the air chambers to alternately create suction and positive fluid pressure
in the, fluid chambers. Flat checks insure a positive flow of fluid. Pump cycling will begin as air pressure is a pplied and it will continue to
pump and keep up with the demand. It will build and maintain line
pressure and will stop cycling once maximum line pressure is reached
(dispensing device closed) and will resume pumping as needed. Model PD02P-XDS-DTX: The Acetal material used in this pump contains Stainless Steel fibers. Its conductivity allows it to be connected to a
suitable ground. A ground screw is provided for this.
HARDWARE MATERIAL
S - Stainless Steel
CHECK VALVE SEAT MATERIAL
D - Groundable Acetal K - PVDF (Kynar)
Polypropylene
P -
CHECK MATERIAL
-
DIAPHRAGM / “O”-RING MATERIAL
A - Santoprene / E.P.R. G - Nitrile / Nitrile T - T.F.E. (Teflon) / T.F.E. (Teflon) / Nitrile
FLUID SECTION SERVICE KIT SELECTION PD02P-X X S-X T X EXAMPLE: MODEL # PD02P-ADS-DTA 637313
FLUID SECTION SERVICE KIT # 637313-DA
MODEL DESCRIPTION CHART
oundable Acetal
Wet End Material
Diaphragm Material
PD02 P -XXS -XT
X
X
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
EXCESSIVE AIR PRESSURE HAZARDOUS MATERIALS STATIC SPARK HAZARDOUS PRESSURE
WARNING
personal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as stated on the Pump model plate.
Be sure material hoses and other components are able to with stand fluid pressures developed by this pump. Check all hoses for damage or wear. Be certain dispensing device is clean and in proper working condition.
WARNING
in severe injury or death. Ground pump and pumping system
PD02P-XDS-DTX Groundable Acetal pumps: Use the pump grounding screw provided. A screw terminal is provided on the manifold. Connect a 12 ga. (min.) wire (66885-1 kit is available) to a good earth ground source.
The pumping system and object being Sprayed must be grounded when it is pumping, flushing, recirculating or spraying flammable materials such as paints, solvents, lacquers, etc. or used in a location where surrounding atmosphere is conducive to spontaneous combustion.
Use the PUMP grounding screw terminal provided. Use Part No. 66885-1 Ground Kit or connect a suitable ground wire (12 ga. min.) to a good earth ground source.
Secure pump, connections and all contact points to avoid vibration and generation of contact or static spark.
Consult local building codes and electrical codes for specific grounding requirements.
After grounding, periodically verify continuity of electrical path to ground. Test with an ohmmeter from each component (e.g., hoses, pump, clamps, container, spray gun, etc.) to ground to insure continuity. Ohmmeter should show 100 ohms or less.
Submerse the outlet hose end, dispensing valve or device in the material being dispensed if possible. (Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and
sparks.
Keep containers closed when not in use.
WARNING
cause severe injury. Pipe exhaust away from work area and personnel.
In the event of a diaphragm rupture material can be forced out of the air exhaust muffler.
Pipe the exhaust to a safe remote location when pumping hazardous or inflammable materials.
Use a grounded 1/4" min. i.d. hose between the pump and the muffler.
WARNING
injury or property damage. Do not service or clean pump, hoses or dispensing valve while the system is pressurized.
EXCESSIVE AIR PRESSURE. Can cause
STATIC SPARK. Can cause explosion resulting
Pump exhaust may contain contaminants. Can
HAZARDOUS PRESSURE. Can result in serious
Disconnect air supply line and relieve pressure from the system by opening dispensing valve or device and / or carefully and slowly loosening and removing outlet hose or piping from pump.
WARNING
HAZARDOUS MATERIALS. Can cause serious injury or property damage. Do not attempt to return a pump to the factory or service center that contains hazardous material. Safe handling practices must comply with local and national laws and safety code requirements.
Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions.
CAUTION
Verify the chemical compatibility of the pump wetted parts and the substance being pumped, flushed or recirculated. Chemical compatibility may change with temperature and concentration of the chemicals) within the substances being pumped, flushed or circulated. Consult Form No. 8677-P. Fluid Compatibility Guide, for information on chemical compatibility.
CAUTION
Maximum temperatures are based on mechanical stress only. Certain chemicals will significantly reduce maximum safe operating temperature. Consult Fluid Compatibility Guide for chemical compatibility and temperature limits. Refer to PUMP DATA on page 1 of this manual.
CAUTION
Be certain all operators of this equipment have been trained for safe working practices, understand it's limitations, and wear safety goggles / equipment when required.
CAUTION
Do not use the pump for the structural support of the piping system. Be certain the system components are properly supported to prevent stress on the pump parts.
Suction and discharge connections should be flexible connections (such as hose), not rigid piped, and should be compatible with the substance being pumped.
CAUTION
Prevent unnecessary damage to the pump. Do not allow pump to operate when out of material for long periods of time.
Disconnect air line from pump when system sits idle for long periods of time.
CAUTION
Use only genuine replacement parts to assure
compatible pressure rating and longest service life.
NOTICE
Replacement warning labels are available upon
request: "Static Spark & Diaphragm Rupture" PN \ 94080.
WARNING
= Hazards or unsafe practices which could result in severe personal injury, death or substantial property damage.
CAUTION
= Hazards or unsafe practices which could result in minor personal injury, product or property damage.
NOTICE
=Important installation, operation or maintenance information.