LIMITED WARRANTY FOR HENNY PENNY APPLIANCES
Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny Penny appliances and replacement parts:
New Equipment Any part of a new appliance, except lamps and fuses, which proves to be defective in material or workmanship within one year from date of original installation, will be repaired or replaced without charge F.O.B. factory,Eaton, Ohio, or F.O.B.authorized distributor. To validate this warranty,the registration card for the appliance must be mailed to Henny Penny within 10 days after installation.
Replacement Parts Any appliance replacement part, except lamps and fuses, which proves to be defective in material or workmanship within 90 days from date of original installation will be repaired or replaced without charge F.O.B. factor y, Ea ton, Ohio, or F.O.B. authorized distributor.
This warranty covers only the repair or replacement of the defective part and does not include any labor charges for the removal and installation of any parts, travel or other expenses incidental to the repair or replacement of a part.
Any claim must be presented to either Henny Penny or the distributor from whom the appliance was purchased. No allowance will be granted for repairs made by anyone else without Henny Penny’s written consent.If damage occurs during shipping, notify the carrier at once so that a claim may be filed.
THE ABOVE LIMITED WARRANTY SETS FORTH THE SOLE REMEDY AGAINST HENNY PENNY FOR ANY BREACH OF WARRANTY OR OTHER TERM. BUYER AGREES THAT NO OTHER REMEDY (INCLUDING CLAIMS FOR ANY INCIDENTAL OR CONSEQUENTAL DAMAGES) SHALL BE AVAILABLE.
The above limited warranty does not apply (a) to damage resulting from accident, alteration, misuse, or abuse; (b) if the equipment’s serial number is removed or defaced; or (c) to lamps and fuses.
THE ABOVE LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES,EXPRESS OR IMPLIED, INCLUDING MERCHANT ABILITY AND FITNESS,AND ALL OTHER WARRANTIES ARE EXCLUDED. HENNY PENNY NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Indication of Safety Warnings
Throughout this manual you will see the following words and symbols relating to important issues of personal safety and proper operation. Their usage is described here:
The word DANGER indicates an imminent hazard which will result in highly serious injury, such as severe burns.
The word WARNING is used to alert you to a procedure, that if not performed properly, may cause personal injur y.
The word CAUTION is used to alert you to a procedure, that if not performed properly, may damage the equipment.
The word IMPORTANT is used to highlight especially important information. The word NOTE is used to separate additional useful subject matter for the sake of clarity.
2
Dear Customer, Congratulations on your decision to purchase a new Henny Penny
ClimaPlus
®
Combi. In our opinion, you now possess the most advanced combi in the industry, featuring IQT–Intelligent Cooking Technology– and the unique ClimaPlus
®
Control which provides the ideal cooking climate for every type of food. As you begin to become familiar with its operation and more confident in the results, you will see the incredible potential for quality, variety and productivity this unit has to offer.
The new ClimaPlus
®
Combi is not difficult to operate, but it is a fairly sophisticated piece of equipment. We recommend a thorough study of this Applications Manual. It is filled with information, suggestions, and explanations that will help you achieve the potential of the unit. Keep the manual in a safe place, but accessible for easy reference.
Henny Penny products are known for their outstanding craftsmanship, leading edge technology and user-friendly operation. As a company, we believe in establishing a partnership with our customers that leads both parties to long-term success. In that spirit, we remain interested in any questions, comments, suggestions or ideas you may have concerning the combi you have purchased, as well as this manual.
We hope you enjoy good food and good profits with your new Henny Penny ClimaPlus
®
Combi. Welcome to the world of imaginative cooking.
Henny Penny Corporation
+1 937 456.8400 Toll free in USA
800 417.8417 www.hennypenny.com
Table of Contents
General Information
Models and Features ................................................................................................5
Control Panel Functions ..........................................................................................8
Basic Operation and Settings ..................................................................................9
Loading and Unloading..........................................................................................10
ClimaPlus
®
Control................................................................................................13
Operating the Clima Plus Combi
Cooking Modes ..............................................................................................................16
Moist Heat Mode ..................................................................................................17
Tender Steaming ....................................................................................................19
Forced Steaming ....................................................................................................21
Dry Heat Mode ....................................................................................................23
Combination Mode ..............................................................................................25
Rethermalizing ......................................................................................................27
Cooking Functions
Probe Cooking with IQT Sensor ....................................................................................30
IQT Logic Programs
IQT +Profile Cooking ............................................................................................33
IQT +Low-T Cooking ..........................................................................................35
IQT +Delta-T Cooking ........................................................................................37
IQT Key Special Functions
Preset Program Library ..........................................................................................39
Half-Energy............................................................................................................39
Delta-T ................................................................................................................40
HACCP Interface ..................................................................................................41
Programming..................................................................................................................43
Additional Key Pad Functions
Steam Injection......................................................................................................51
Half Speed Fan ......................................................................................................52
Pulse Fan................................................................................................................52
Cool Down............................................................................................................53
Cleaning..........................................................................................................................54
Conventional Cleaning ..........................................................................................54
Using CleanJet
®
......................................................................................................55
CDS CalcDiagnosis System....................................................................................58
Installation – Electric and Gas Units ..............................................................................59
Cooking Guides..............................................................................................................68
Distributors ....................................................................................................................83
3
4
General Information
In this section:
Models and Features at a glance Control Panel Functions at a glance Basic Operation Loading and Unloading ClimaPlus Control
ClimaPlus Combis from Henny Penny have the potential to make your entire approach to foodservice production simpler, more consistent and more productive.
Simpler because, ultimately, you will use fewer appliances as you become more adept at utilizing the ClimaPlus for different applications.
More consistent because the ClimaPlus Combi is designed to produce the perfect cooking climate for just about any type of food. With its sophisticated electronics and program capacity, the ClimaPlus can do it every time.
More productivebecause its versatility and automation combine to make efficient use of both skilled and unskilled labor. Not to mention, ClimaPlus cooks faster with less food shrinkage than conventional appliances and practically cleans itself.
The ClimaPlus Combi uses pressureless steam and hot-air convection, along with the patented ClimaPlus Control, in nearly infinite combinations to create perfect foods. IQT Sensor and IQT Logic enable self-regulating cooking processes. There are plenty of other features and functions, all designed to make cooking easier and more precise.
As you become more familiar with the way the machine operates and the cooking concepts it employs, experiment! Try different settings. Change modes and ClimaPlus settings at any time in the cooking cycle (you can.) Observe the results, adjust your approach. In short, learn and use the capabilities of the ClimaPlus Combi to create the kind of food you want to create.
5
GENERAL INFORMA TION
Models and Featuresat a glance
Models and sizes available
Model numbers are designated according to pan capacity. Units are available in either electric (LCS) or gas (LCG.)
NOTE: Features may vary between gas and electric models. Accessories may vary according to unit size.
A reference such as “LCS models” or “LCS-6/10/1020/20/40” designates the LCS electric model in all sizes. A reference such as “LCG base-top models” or “LCG­6/10/1020” designates only LCG gas models of those sizes.
Features
Cooking modes and applications
Moist Heat
Steaming
Tender Steaming
Forced Steaming
Dry Heat
Combination Moist and Dry
Rethermalizing
Base-top models
Floor models
LCS-6 LCG-6
LCS-10 LCG-10
LCS-1020 LCG-1020
LCS-20 LCG-20
20 steam table pans or 20 half sheet pans
LCS-40 LCG-40
40 steam table pans or 20 steam table pans or 40 half sheet pans or 20 full sheet pans
6 steam table pans or 6 half sheet pans
10 steam table pans or 10 half sheet pans
10 full sheet pans with rack adapter or
20 steam table pans or 10 steam table pans
12 x 20 x 2
1
2 (325 x 530 x 65)
13 x 18 (330 x 457)
12 x 20 x 2
1
2 (325 x 530 x 65)
13 x 18 (330 x 457)
18 x 26 (457 x 660)
12 x 20 x 2
1
2 (325 x 530 x 65)
20 x 24 x 2
1
2 (530 x 650 x 65)
12 x 20 x 2
1
2 (325 x 530 x 65)
13 x 18 (330 x 457)
12 x 20 x 2
1
2 (325 x 530 x 65)
20 x 24 x 2
1
2 (530 x 650 x 65)
13 x 18 (330 x 457) 18 x 26 (457 x 660)
6
Control
ClimaPlus Control regulates precise humidity for unlimited combinations of
moist and dry heat.
Fully digital operation
Alphanumeric LED readouts featuring optional Asian character display
Auto-reverse fan
Cooking control functions:
Steam Injection
Half Speed Fan (Available on all LCS electric models and the LCG-40)
Pulse Fan
Half Energy (Available on all LCS electric models)
IQT Sensor food probe with five point temperature measurement
Automated cooking
99 nine-step custom cooking program capacity
IQT key access to preset program librar y, Half Energy operation, Delta-T and
Profile cooking applications, HACCP interface
IQT automated cooking applications:
+Delta-T
+Low-T
+Profile
Design and operation
Auto-reverse fan
Filterless grease extraction
Cool down
Dual glass door
Safety latch handle (Standard on all floor models, available as option on all
base-top models)
HACCP interface and serial port
Auto flush
Built-in retractable hand shower
CleanJet automated cleaning system
CDS CalcDiagnosis displays level of sediment build-up in steam generator
GENERAL INFORMA TION
Models and Features
continued
GENERAL INFORMA TION
Models and Features
continued
7
1. Steam is created and dispersed
rapidly from the self-cleaning steam generator.
2. Dry heat up to 575°F (300°C)
is produced by tubular electrical elements or gas burners.
3. Select either Moist Heat or
Dry Heat modes, or both for Combination cooking. Set the desired humidity level with the ClimaPlus control.
4. Precise combinations of moist
and dry heat create the ideal cooking climate for virtually any type of food. Patented ClimaPlus Control measures and regulates the humidity in all modes.
5. ClimaPlus regulates cooking
climate by automatically removing excess humidity
to maintain desired level.
6. IQT Sensor and IQT Logic enable cooking applications that self­adjust to conditions of the food and the environment in the cabinet.
7. Auto-reverse fan and air circulation system keep temperatures precise and heat distribution uniform throughout the cabinet, even when cooking full loads.
8. Hinged racking system or mobile oven rack accepts a wide range of pans and grids.
9. Coved corners, filterless grease extraction system, built-in handshower and CleanJet automated cleaning system minimize cleaning labor.
1
2
3
4
5
7
8
9
How it works
6
0I
PROG
START
ON/OFF switch ClimaPlus function key with control arrows (green)
ClimaPlus display window MOIST HEAT MODE key DRY HEAT MODE key
Press MOIST HEAT MODE key and DRY HEAT MODE key for COMBINATION MODE
CABINET TEMPERATURE indicator key CABINET TEMPERATURE display
TIMER activation key
Press and hold for continuous run
COOKING TIME display
IQT SENSOR key IQT SENSOR display
IQT key IQT display
Program Library Additional Functions
PROGRAM/START key & additional PROGRAM display COOL DOWN key PULSE FAN key HALF SPEED FAN key (not available on LCG gas models) STEAM INJECTION key
CENTRAL DIAL Unit serial number (located on the left side
of cabinet in the lower right hand corner)
Please refer to this number when requesting service
COOK SYSTEM
LCS COMBI
ClimaPlus
reset
LCG gas models will have this key pad display
RESET
indicator
STEAM
INJECTION
KEY
PULSE
FAN
key
COOL
DOWN
key
8
Control Panel Functionsat a glance
GENERAL INFORMA TION
9
GENERAL INFORMA TION
Basic Operation and S ettings
Turning unit on
Press the ON/OFF button.
ON appears in the display for 2 seconds followed by the current time.
Select Cooking Mode
Press Moist Heat key for steaming (See Moist Heat Mode, page 17.)
OR press Dry Heat key for baking or roasting without added humidity
(See Dry Heat Mode, page 23.)
OR press Moist and Dry Heat keys at the same time for Combination Mode
(See Combination Mode, page 25.)
Choosing Time and Temperature Cooking
Press TIMER key and set desired Cooking Time.
Press TEMPERATURE key and set desired Cooking Temperature.
Dial in settings while the display is flashing. In most cases, settings can be changed in this manner at any time during the cooking process.
Choosing IQT Sensor Cooking
Press IQT Sensor key and set D one temperature (see Probe Cooking, page 31.)
Set desired level of ClimaPlus Control (See ClimaPlus Control, page 14.)
Set other desired functions.
Dial in settings while the display is flashing. In most cases, settings can be changed in this manner at any time during the cooking process.
Choosing Custom Program Cooking
DO NOT select Cooking Mode. Deactivate if mode has already been selected.
Press PROG/START key and use Central Dial to select desired custom cooking
program by name or number. Do not select flashing numbers. In this case, they indicate empty (available) program slots.
Press PROG/START again to activate selected program.
Checking current cooking conditions
While unit is operating, press Temperature key and hold to display:
Current humidity in cabinet
Current temperature in cabinet
Elapsed cooking time
Current probe temperature
Program number/step if running on automatic program
0I
PROG
START
10
Loading and U nloading
Your Henny Penny ClimaPlus Combi includes either a removable hinged racking system (standard with 6 and 10-pan units) or a mobile oven rack that is integral to the equipment’s operation. All pans and grids are loaded directly onto the hinged racking system, or onto the mobile oven rack which is then rolled into the cooking cabinet.
Removable Hinged Racking–Standard LCS/G- 6 & 10
To remove, simply lift rack upward and out of mountings. Reverse the action to replace the rack. To move rack laterally on hinges, lift front of rack slightly to clear mounting and swivel rack.
Base-top Models
Mobile Oven Racks (Standard on 1020)
Oven rack on transport cart rolls up to the front of the unit. Oven rack rolls completely into the cabinet. Standard with LCS/LCG-1020, available separately (rail system required) for LCS/LCG-6 and10.
Floor Models
Mobile Oven Racks (Standard on 20 and 40)
Mobile oven rack rolls directly into unit. Specially designed oven rack allows cabinet door to close easily and completely around the rack. Standard with LCS/G-20 and 40. Additional mobile oven racks or specially designed oven plate racks are available separately.
IMPORTANT!
When using the oven rack on transport cart, be sure to lock the front casters of the transport cart when it is in the loading or unloading position at the front of the cabinet. Keep the front wheels of the oven rack locked at all times (using the locking lever near the right front wheel) except when rolling it into or out of the cabinet and onto the transport cart itself. Following this procedure stabilizes the load. To keep pans in place lock both vertical hinged bars.
To Load
Preheat unit to set temperature.
Place food product on appropriate grids, pans and racks.
If using mobile oven rack, slide full grids, pans and racks into shelves on mobile
oven rack. Be sure containers are secure on both sides.
Opening door during operation
Open door slightly until fan stops and heat dissipates. Open door fully with care.
GENERAL INFORMA TION
Mobile Oven Racks
Transport Cart
(optional)
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
11
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door slightly until fan stops and steam dissipates. Open door fully with care to unload.
Load hinged racking system with food containers or roll loaded mobile oven rack
directly into unit.
Shut door and begin cooking.
To unload
Open door slightly until fan stops and heat dissipates. Open door fully with care.
Remove cart handle.
Using oven mitts or pads, remove food containers carefully from shelves in
hinged racking system.
With floor units, roll mobile oven rack straight out of unit to appropriate location.
With base-top models using transport cart, roll transport car t up to front of
unit and lock front casters. Roll oven rack out of unit and onto transport cart. Be sure wheels on oven rack are locked to stabilize load and reduce the chances of spills.
GENERAL INFORMA TION
Loading and Unloading
continued
WARNING: Surfaces of food containers, mobile oven racks and inside cabinet surfaces may be extremely hot. Always use insulated oven mitts or pads when removing food containers or handling mobile oven racks or burns could result.
12
Partial Loads
Individual pans or racks of product can be easily loaded or unloaded while the unit is in operation.
Open door slightly until fan stops and heat dissipates. Open door fully with care.
Using oven mitts or pads, load or unload individual containers.
Shut door. Cooking process continues automatically.
Tips
Preheat cooking cabinet prior to loading for full loads.
Since no flavor transfer occurs during cooking, try to plan full loads based on
similar cooking climates (Moist, Dry, Combination) rather than food compatibility.
When cooking for longer periods, or on continuous run cooking, load items
that will be done sooner toward the front of the oven. These can be removed individually when done.
For the greatest efficiency, try to cook with full loads. In general, cooking times
and temperatures are not affected by the quantity of product in the cooking cabinet.
When loading roasts or large cuts of meat, place product grids and load grids
directly onto shelves near the bottom of the unit. Load an empty pan directly beneath the roast to catch drippings and roast bones.
For base-top models, consider the purchase of Combi Base Units. Several styles
are available that offer storage for convenient access to pans, grids, and racks.
If rethermalizing plated portions is a frequent part of your production, consider
the purchase of special plate racks and thermal covers.
GENERAL INFORMA TION
Loading and Unloading
continued
13
ClimaPlus®Control Precise automatic humidity control
Use ClimaPlus Control to set, measure and maintain desired humidity in the cooking environment. ClimaPlus is a patented technology that precisely and automatically measures and controls the amount of humidity in the cooking climate. This gives operators the flexibility and control to produce crisp crusts for roast chicken... tender consistency for roasts, ribs, and meat loaf... delicate evenness for light breads, cakes and pastries... perfect browning for au gratin dishes, casseroles, and pies.
Advantages
Control humidity to:
Improve the quality of foods with different textures and consistencies.
Enable precise finishing of delicate items.
Cook a wide variety of foods at the same time, including sauces and stocks.
Achieve proper cooking intensity for doughy pastries.
Increase humidity to:
Promote basting.
Retain foods natural flavors and nutrients.
Prevent dehydration for increased portions.
Remove humidity to:
Achieve browning.
Increase crispness and texture.
Maintain a consistent environment when baking or roasting wet foods.
Tips
A good approach to using ClimaPlus is to observe the cooking process and react with the appropriate adjustment to the humidity level. Use ClimaPlus when:
Food perspires
Condensation forms on pans
Browning needs to proceed more rapidly
ClimaPlus Control is most effective with foods that have high moisture content.
ClimaPlus is well suited to maintain a consistent environment when cooking
frozen or partially frozen meats, casseroles, entrées or side dishes.
Be sure to use Combination Mode if you wish ClimaPlus to add humidity.
GENERAL INFORMA TION
14
Capabilities
ClimaPlus works by constantly monitoring and controlling the level of humidity in the cooking environment. Most foods release moisture into the air as they cook, naturally building excess humidity in the cabinet. When humidity rises above the set level, ClimaPlus removes excess moisture. When humidity drops below the set level, ClimaPlus signals the steam generator to add moisture into the cabinet .
The ClimaPlus window and controls are designed to display important information about the cooking climate at a glance:
When cooking in Combination Mode, the horizontal display lights
up as a bar that is part blue and part red, with blue representing moist heat and red representing dry heat.
The amount of blue and red showing indicates the desired
combination of moist and dry heat as set by the Central Dial.
The small green number displayed above the red/blue bar is the
actual percentage of relative humidity in the cabinet.
The ClimaPlus arrow key is used to activate ClimaPlus Control. During operation,
the arrows light up to indicate ClimaPlus activity. The up arrow lights up to indicate that steam is being added to the cabinet. The down arrow lights up when humidity is being removed from the cabinet.
Operation
Select Dry Heat or Combination Mode.
NOTE: Steam Generator is not active in Dry Heat mode. Therefore, ClimaPlus functionality is limited to removing humidity from the cabinet. Moisture from food may continue to build during cooking process but cannot be increased by ClimaPlus.
Press the ClimaPlus Control arrow key.
Use the Central Dial to set the desired humidity level.
To check the current humidity level:
Press and hold TEMPERATURE key. The current humidity level in the cooking
cabinet is displayed in the ClimaPlus window.
GENERAL INFORMA TION
ClimaPlus Control
continued
Operating the ClimaPlus®Combi
In this section:
Cooking Modes Cooking Functions Cleaning Installation
The following section presents in some detail a complete overview of the operation of your Henny Penny ClimaPlus Combi. You'll find the advantages, tips and step-by-step operating instructions for each feature of the LCS and LCG models, from cooking modes to IQT applications and additional keypad functions.
The programming section included in Cooking Functions will help you customize the day-to-day operation of the ClimaPlus Combi to your particular production needs. Simple instructions, accompanied by visual icons of the appropriate control panel keys, make it easy to do everything from creating custom programs to setting up the displays for the desired time, temperature and language formats.
The Cleaning section explains the advantages and operation of the CleanJet automated cleaning system and CDS CalcDiagnosis feature. The Installation section offers basic information about site requirements and the water, electrical and gas connections necessary to properly install and set up the ClimaPlus Combi for operation.
15
16
Cooking M odes
ClimaPlus Combis have two basic cooking modes: Moist Heat and Dry Heat. These two cooking modes can be used individually, in sequence,
or together in a third Combination mode. Almost all traditional cooking processes can be accomplished in these modes.
Moist Heat Mode
The steam generator produces hygienic steam and releases it (without pressure) into the cooking cabinet where it is circulated at high speeds by the fan. The cooking temperature in this mode can be regulated from 85-265°F (30-130°C) to accomplish:
Steaming
Tender Steaming
Forced Steaming.
Dry Heat Mode
Powerful heating elements heat the air inside the cabinet. The fan circulates this hot, dry air evenly throughout the interior. Temperature can be regulated precisely between 85-575°F (30-300°C).
Cooking environment can be manipulated extensively with additional functions
and ClimaPlus Control.
Combination Mode
The unit’s control system combines both Moist Heat and Dry Heat modes to create a cooking environment in which variable amounts of humidity can be introduced and controlled at temperatures from 85-575°F (30-300°C).
Cooking environment can be manipulated extensively with additional functions
and ClimaPlus Control.
Rethermalizing is accomplished in Combination Mode at 60% humidity or less.
17
Moist Heat Mode 212°F (100°C)
Pressureless steam generation and auto-reverse fan quickly produce a cooking environment of 100% humidity. Perfect for steaming a wide variety of foods with no flavor transfer. Also used for stewing, blanching, poaching, simmering, soaking, thawing, rethermalizing, preserving.
Advantages
Extremely short preheating time.
Excellent food consistency.
Conser ves nutrients, color.
No added fats or oils.
Cook different products at the same time with no flavor transfer.
Can be partially unloaded for serving convenience.
No need to boil water in pots.
Menu suggestions
Ingredients preparations–tomato concasees, garnish, mushrooms, blanched
vegetables for stuffing, peeling, etc.
Starters, appetizers–scrambled, poached or boiled eggs; vegetable pate, asparagus,
stuffed vegetables, cannelloni.
Entrees–cooked beef, ham, turkey legs, steamed fish, chicken breasts.
Sides–rice, dumplings, pasta, fresh and frozen vegetables, boiled potatoes, and
grains.
Tips
Determine which foods can be cooked together for the greatest production
efficiency. This is best done by considering the cooking modes and temperatures. Keep in mind that fish, meat, vegetables, fruit, etc. can be cooked at the same time because no flavor transfer occurs.
Potatoes should always be cooked in perforated pans. This allows steam to
circulate for faster, more even cooking.
In general, two shallower pans are better than one deeper pan. This avoids bruising.
Dumplings should be placed in shallow pans not too close together.
Rice, dr y pasta, beans, and grains are foods to which water must be added prior
to cooking. Longer soaking times mean shorter cooking times.
Tomatoes can be skinned easily when steamed for 30 to 60 seconds, then chilled
in cold water.
Stock can be collected by inserting a container in the bottom of the oven rack.
COOKING MODES
18
Operation and Settings
Turn unit on.
Select MOIST HEAT mode and set TIMER on Continuous Run. Only blue
bars appear in ClimaPlus window indicating 100% moist heat.
Preheat until temperature reaches 212°F (100°C), or to desired temperature.
Load oven.
Select TIMER key. Set desired cooking time using Central Dial OR select IQT
Sensor and set desired Sensor core temperature OR select Continuous Run.
ClimaPlus control is preset at 100% humidity and cannot be changed in Moist
Heat mode.
Unload oven when done. Unit automatically shuts off when door is opened.
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door
slightly until fan stops and steam dissipates. Open door fully to unload.
COOKING MODES
Moist Heat
continued
CONT-RUN
CONT-RUN
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
19
Tender Steaming 85-210°F (30-99°C)
A gentle cooking application in Moist Heat mode that uses steam with less air turbulence at temperatures below the boiling point. Use Tender Steaming for scalding, poaching, thawing, proofing, simmering, blanching, rethermalizing, soaking, vacuum cooking, and preserving.
Advantages
Fast preheating.
The ability to select and maintain precise low cooking temperatures.
Gentle steaming for a variety of delicate items.
Excellent consistency and taste for many kinds of meat and fish.
Lower cooking temperatures mean less sticking and crumbling.
Less shrinkage resulting in moist, attractive portions for display merchandising.
No added fats or oils are needed for cooking.
Excellent method for proofing breads and doughs at 95-99°F (35-37°C).
Can be partially unloaded for serving convenience.
Menu suggestions
Ingredients preparations–blanching bacon and ham, proofing, soups, sauces,
stocks, fish garnishings, etc.
Starters, appetizersPoached eggs, seafood, cakes, patés, etc.
Entrees–Fish (salmon, sole, orange roughy), poultry, vacuum cooking items,
boneless chicken and turkey filets, beef filets, sausages, etc.
Sides-Vegetable casseroles
Desserts–fruit, cheese cakes, delicate moist items, etc.
Yeast doughsbreads, rolls, bagels, etc.
Tips
Approximate temperature ranges for some common Tender Steamed items:
Soup garnishings 167-194°F 75-90°C Fish, seafood 149-194°F 65-90°C Pork, veal 161-167°F 72-75°C Chicken/white meat 167-185°F 75-85°C Chicken/dark meat 176-194°F 80-90°C Poultry (other) 176°F80°C Beef, lamb 135-165°F 58-74°C Desserts 149-194°F 65-90°C Breads, doughs 95-99°F 35-37°C
COOKING MODES
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
CONT-RUN
CONT-RUN
Cooking times
Moist Heat mode principles apply: generally, the lower the cooking temperature the longer the cooking time.
Seasoning
Season lightly. Low temperature cooking intensifies a food’s natural taste, as well as the taste of seasonings. For the same reason, use less essences or reducing agents.
Texture, appearance
Tender Steaming imparts excellent characteristics to food for presentation in display merchandisers:
Excellent color
Firm structure for clean portioning
Less shrinkage for plump, taut skins
Fewer and smaller bursts even when skin is damaged
Operation and settings
Turn unit on.
Select MOIST HEAT mode and set TIMER on Continuous Run.
Preheat until temperature reaches 212°F (100°C) or to desired temperature.
Load oven.
Set desired Tender Steaming TEMPERATURE 85-210°F (30-99°C) using
Central Dial.
Select TIMER key. Set desired cooking time using Central Dial OR
Select IQT Sensor and set desired core temperature using Central Dial OR
select Continuous Run.
Unload oven when done. Unit automatically shuts off when door is opened.
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door
slightly until fan stops and steam dissipates. Open door fully to unload.
COOKING MODES
20
Tender Steaming
continued
21
F or ced Steaming 213-265°F (101-130°C)
A cooking application in Moist Heat mode using additional heat to allow full-humidity steaming at temperatures well above boiling. Forced Steaming is excellent for cooking dense products, such as root vegetables and frozen casseroles.
Advantages
Creates an intensified cooking process
Shorter cooking times
Product retains color, nutrients
Less shrinkage
Menu suggestions
Potatoes, carrots, celery
Frozen prepared foods
Tips
Approximate temperature ranges for some common Forced Steamed items:
Celery 230°F 110°C Carrots 240°F 115°C Potatoes 257°F 125°C Turnips, yams 248°F 120°C Frozen lasagna 248°F 120°C Frozen vegetables 248°F 120°C Rice 248°F 120°C
COOKING MODES
CONT-RUN
CONT-RUN
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
22
Operation and settings
Turn unit on.
Select MOIST HEAT mode and set TIMER on Continuous Run.
Preheat to set temperature.
Load oven.
Set desired Forced Steaming TEMPERATURE 213-265°F (101-130°C) using
Central Dial.
Select TIMER. Set desired cooking time using Central Dial OR select
IQT Sensor and set desired core temperature using Central Dial OR select Continuous Run.
Unload oven when done. Unit automatically shuts off when door is opened.
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door
slightly until fan stops and steam dissipates. Open door fully to unload.
COOKING MODES
Forced Steaming
continued
23
Dry Heat M ode85-575°F (30-300°C)
Po werful convection heating and auto-reverse fan create the ideal environment for fast, even broiling, roasting, baking, browning, thawing, grilling and sautéing.
Advantages
Powerful heating capability up to 575°F (300°C), even when fully loaded.
Fast pre-heating.
High-speed air circulation creates even heating for high quality food production.
Consistent cooking and even browning at all rack levels.
No added fats or oils are needed for cooking.
Cook different products at the same time with no flavor transfer.
Can be partially unloaded for serving convenience.
Menu suggestions
Ingredients preparations–roasted bones for stock, melting butter, thawing
frozen ingredients.
Starters, appetizers–meatballs, roast beef, grilled ham, sausage, chicken wings,
quiches, tarts, breadsticks, bread rolls, etc.
Entrees–beef and pork roasts, ribs, chicken whole or piece, turkey, frozen lasagna,
pizza, pizza rolls.
Sides–baked potatoes, soufflés, casseroles.
Desserts–sponge cake, marble cake, puff pastries, frozen fruit puffs, pies, etc.
Tips
Cooking times
Proper cooking times will vary depending on the quality, weight, or size of the product being cooked. Generally, cooking time is not affected by the size of the load. However, avoid overloading grids or pans so air will circulate evenly around all product.
Roasting, broiling
Preheat up to 575°F (300°C). Load and set to desired temperature.
Ideal thickness for steaks, chops, cutlets, or loin cuts:
1
2
-1 in. (13-25mm).
Cook on grids with drip pans underneath. This allows even browning on all sides.
Group similarly sized products on the same grids.
Sautéing
Preheat enamel pan.
Shallow pans work best.
Browning, finishing
Preheat up to 575°F (300°C). Load and set to desired temperature.
COOKING MODES
CONT-RUN
CONT-RUN
24
Baking
Preheat to desired baking temperature. In general, ClimaPlus Combi baking
temperatures will be 70-80°F (20-25°C) LOWER than conventional ovens.
When baking do NOT preheat pans.
For bread, rolls, and muffins use only every second rack. Trays should not be
deeper than 23⁄4
in. (70mm).
Defrost frozen bread dough and let rise for a short time before baking.
When baking full loads of wet product (frozen or dough), adjust ClimaPlus to
remove built-up humidity.
Lightly mist breaded products with water or vegetable oil or brush with eggwash.
When baking whole fish, wrap tail in foil and support it from underneath with
raw potatoes.
Operation and settings
Turn unit on.
Select DRY HEAT mode and set TIMER on Continuous Run.
Two red bars appear in ClimaPlus window.
Preheat, set to desired cooking TEMPERATURE.
Load oven.
Select TIMER key. Set desired cooking time using Central Dial OR select IQT
Sensor and set desired core temperature using Central Dial OR select Continuous Run.
NOTE: Steam generator does not operate during Dry Heat Mode. However, humidity builds in the cabinet from the moisture escaping food as it cooks. Use ClimaPlus Control to limit the level of this humidity buildup if desired.
If desired, press arrow key and set ClimaPlus Control using Central Dial.
Unload oven when done. Unit automatically shuts off when door is opened.
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door
slightly until fan stops and steam dissipates. Open door fully to unload.
COOKING MODES
Dry Heat
continued
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
25
Combination Mode 85-575°F (30-300°C)
Fast, consistent method for cooking foods that require a combination of moist and dry heat. Enables practically any percentage of humidity and precise control of the desired level. Use when combi-baking, combi-roasting, combi­steaming, browning, braising, glazing, basting.
Advantages
Fast preheating.
Cook with steam at temperatures above 212°F (100°C).
Less food shrinkage from dehydration.
More servings per cooked pound.
Automatic basting.
Foods retain more nutrients and flavor.
No added fats or oils are needed for cooking.
Even heating improves cooked quality of large meat portions.
Cook different products at the same time with no flavor transfer.
Consistent cooking and browning at all rack levels.
Can be partially unloaded for serving convenience.
Menu suggestions
Ingredients preparationsroasted bones for stock.
Starters, appetizersquiche, pastas, bread, rolls (frozen), etc.
Entrees–roasts (beef, veal, pork, lamb) stuffed peppers, whole roast chicken,
turkey legs, casseroles, lasagna, etc.
Sides–potatoes au gratin, baked potatoes, frozen vegetables, baked apples, etc.
Desserts–yeast dough (choux pastry).
Tips
To achieve even cooking and browning, always cook roasts on grids with plenty
of space around each roast for air to circulate.
When practical, place roasts on grids with meat grain parallel to airflow for even
better results.
Cook large, fat-encrusted roasts in MOIST HEAT mode for the first one-third
of the total cooking time, then switch to COMBINATION mode with desired settings for the remainder. This technique helps seal in juices, flavors and nutrients while reducing shrinkage.
Condensation and juices can be collected in a pan under the roasts to be used
later with roasted bones for sauce stocks.
Use chicken grid to roast whole chickens upright for even cooking, browning.
COOKING MODES
CONT-RUN
CONT-RUN
26
Operation and settings
Turn unit on.
Press Moist Heat and Dry Heat keys at the same time to set on
COMBINATION mode.
Set TIMER on Continuous Run.
A bar that is mostly blue and partly red appears in ClimaPlus window, indicating
that the ClimaPlus Control is set at 90% humidity.
Preheat to desired temperature.
Load oven.
Set desired cooking TEMPERATURE using Central Dial.
Select TIMER key. Set desired cooking time using Central Dial OR set for
Continuous Run. Select IQT Sensor and set desired core temperature using Central Dial.
To change ClimaPlus Control setting, press the control arrow key and set the
desired humidity level with the Central Dial.
Unload oven when done. Unit automatically shuts off when door is opened.
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door
slightly until fan stops and steam dissipates. Open door fully to unload.
COOKING MODES
Combination
continued
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
27
Rethermalizing
Rethermalizing is a cooking application that utilizes a combination of moist and dry heat plus ClimaPlus Control to maintain flavor and textures when bringing chilled cooked foods back up to serving temperatures.
Advantages
Different food products can be reheated without being covered.
Perfect mode for re-heating ingredients, servings or meals previously cooked and
chilled as part of a cook/chill production process.
Whole meals can be plated and chilled in quantity on special racks that roll
directly from the blast chiller into the ClimaPlus Combi for rethermalizing.
Allows more efficient use of time to prepare dishes and trays ahead of time.
Less shrinkage.
Menu suggestions
Starters, appetizers–pasta, vegetable dishes, macaroni & cheese, casseroles, spring
rolls, etc.
Entrees–roasts, pasta, casseroles, chilled or frozen meat and fish, chilled or frozen
prepared entrees, stuffed vegetable dishes.
Sides–rice and rice dishes, vegetables, noodles, new potatoes, potatoes au gratin,
potato pancakes, fries, etc.
Desserts–fruit pies, cheese cakes, stewed fruit, etc.
Tips
Proper rethermalizing temperatures will vary depending on type of food.
Generally, a ClimaPlus Control setting of 60% humidity or lower is
recommended for rethermalizing.
Rethermalizing times depend on the type of food, the beginning internal
temperature and the number of plates of pans in the load. Times should be from 5 to 8 minutes.
Use probe cooking with the IQT Sensor when practical. Ideal serving
temperatures are easier to achieve.
Re-heating plated servings is more efficient, especially when preparing meals in
volume.
Use special mobile oven rack designed to hold plates for rethermalizing. Racks
roll from blast chiller or walk-in directly into the ClimaPlus Combi. Fitted thermal covers are available to keep plates on rack warm for short periods or during transport.
Make sure food is arranged evenly on plates.
Sauces should be poured over product prior to re-heating or on side after
re-heating.
COOKING MODES
CONT-RUN
CONT-RUN
28
Create a custom cooking program with Rethermalizing settings that can be used
for similar recurring situations.
Use ClimaPlus Control to “fine tune Rethermalizing to achieve desired results.
Operation and settings
Turn unit on.
Press Moist Heat and Dry Heat keys at the same time to set on COMBINATION
mode.
Set TIMER on Continuous Run.
Preheat to desired temperature.
Load oven.
Set desired Rethermalizing TEMPERATURE using Central Dial.
Select TIMER key. Set desired cooking time using Central Dial OR select
Continuous Run. Select IQT Sensor and set desired probe “done temperature using Central Dial.
Adjust ClimaPlus Control setting to achieve desired humidity level, generally
60% humidity or below, by pressing the control arrow key. Set desired humidity level with the Central Dial
Unload oven when done. Unit automatically shuts off when door is opened.
NOTE: LCS & LCG models 20 & 40 have a built-in safety latch that lets steam and heat out before door fully opens. Safety latch is optional on models 6, 10 and
1020. If your ClimaPlus Combi is NOT equipped with this feature, open door
slightly until fan stops and steam dissipates. Open door fully to unload.
COOKING MODES
Rethermalizing
continued
X
Opening Door During Operation
Open door slightly to allow hot steam and/or vapors to escape. KEEP FACE AND HANDS AWAY FROM OPENING or burns could result. When steam and/or heat has dissipated open door fully with care. Escaping hot steam and/or vapors can cause serious burns. Interior surfaces, including pans, grids and oven racks, can be extremely hot. To prevent burns, allow unit to cool or use appropriate heat resistant protective mitt or pad when handling. Do not use built-in retractable hand shower when cabinet temperature is above 212°F (100°C) or burns could result.
Cooking F unctions
ClimaPlus Combis feature a host of digital controlled functions that can be employed to create the perfect cooking environment for practically any type of food. These functions also help automate the cooking process, saving labor and providing consistent results, load after load.
Probe cooking with IQT Sensor
The new IQT Sensor 5-point probe works with IQT Logic and the ClimaPlus Control to automatically produce the desired browning, texture and core food temperature every time–regardless of load size.
IQT Intelligent Cooking Functions
The IQT key accesses three IQT Logic programs that use the IQT Sensor to provide feedback for real-time control and adjustment of the cooking process. These programs are designed to completely automate the lengthy process of cooking roasts or other large cuts of meat. (To access these programs, be sure no cooking mode is active before pressing the IQT key.)
+Profile Cooking
+Low Temperature Cooking
+Delta -T Cooking
Preset program library
The IQT key is also used to access other special functions. (To select these functions, a cooking mode must be activated before pressing IQT key.)
Half Energy (available on all LCS electric models and the LCG-40)
Delta-T (without IQT Logic)
HACCP interface
Lime scale check (CalcDiagnosis System)
Program Lock/Unlock
Programming
Use PROG/START key when inputting up to 99 nine-step custom cooking programs and when working with programs and programmable operations of the unit. Use this key to access and start selected custom program.
Additional Key Pad Functions
Steam Injection
Half Speed Fan (available on all LCS electric models)
Pulse Fan
Cool Down
29
PROG
START
30
P robe Cooking with IQT Sensor
The Probe Cooking function allows the operator to select the food’ s desired “ done” temperatur e. The IQT Sensor probe is inserted into the food to measure the actual internal temperature of the food as it cooks. The IQT Logic controls the cooking time and stops the cooking cycle when the selected internal temperature is achiev ed.
Advantages
Cook to proper “doneness for precise, consistent results with different types
of food.
Prevents over cooking, less waste.
Results in less shrinkage, more portions.
Does not require constant observation of cooking process.
IQT Sensor 5-point measurement eliminates false readings due to improper
insertion.
Check elapsed time and current core temperature at any time.
Eliminates wasteful and unattractive intrusive testing methods such as needle,
fork or cutting.
When to use
Probe cooking can be used for practically any type of food, most often with roasts, meats, poultry, casseroles, entreés, soups, rethermalizing plated portions.
Tips
When roasting meat for sliced cold servings, set food core temperature about
9°F (5°C) lower than recommended “done temperature. Roast will continue to cook as it cools.
A hot probe may sear the meat on contact, leaving a hole or scar when probe is
removed. Always cool probe prior to insertion.
Probe cooking temperatures can be changed or reset at any time during the
cooking process. For example, you may wish to change cooking modes or accelerate the cooking process after a certain core temperature is reached. Simply make those changes and reset probe “done temperature to the desire cooked setting.
Consider using IQT +Profile automated cooking program that allows the
selection of core temperature and desired surface texture and browning.
COOKING FUNCTIONS
31
Operation and settings
Turn unit on.
Load oven rack.
Insert probe into thickest part of meat, or into central location of other types of
foods, on center oven rack.
NOTE: Be sure IQT Sensor is clean and cool prior to insertion.
Select cooking mode (probe cooking is enabled in all modes.)
Select IQT Sensor and set desired done temperature using Central Dial.
Display shows selected done temperature and current core temperature.
NOTE:TIMER function does not operate when using probe function. If TIMER is set before selecting IQT Sensor, the cook time continues to run in the back­ground, but does not control the cooking process. To display time remaining, press and hold both IQT Sensor and TIMER keys. To return to probe temperature display, press IQT Sensor key
To check elapsed cooking time, press and hold TEMPERATURE key.
Completion signal sounds when done temperature is reached. Unit shuts off
automatically.
IQT Sensor
Monitors the surface temperature of the food.
Regulates the degree of browning when
using IQT +Profile
Calculates the precise core temperature,
even when improperly inserted.
Computes and displays the exact
remaining cooking time.
Constantly updates
information as conditions change.
COOKING FUNCTIONS
Probe Cooking with IQT Sensor
continued
The IQT Sensor reads temperatures at five different points:
Surface temperature
Plus four separate core temperatures
X
Probe sensor may be extremely hot
When not in use, always place probe sensor in holder. Do not let probe sensor hang loose outside the cooking cabinet. Remove probe sensor from food before unloading unit.
32
COOKING FUNCTIONS
Probe Cooking with IQT Sensor
continued
Probe Cooking Guide to “Doneness”
Meat Probe “Done Temp” Appearance
Beef Rare 130°F55°C Dark, blood red
Medium rare 140F 60°C Red meat, blood-red juice Medium 145°F63°C Light pink core
Well done 167-189°F 75-65°C Gray-brown throughout Veal Fully cooked 155-170°F 69-77°C Red-brown to gray-white Por k Medium 150°F65°C Light pink
Well done 167-176°F 75-80°C Pale brown to gray-white
Cured 150°F65°C Pale red-brown or nearly
colorless
Lamb Fully cooked 165°F74°C Gray to pale-red juice,
clear juice Mutton Fully cooked 165°F74°C Pale gray meat, red juice Poultry Fully cooked 185°F85°C White meat, nearly colorless
juice
33
IQT +P rofile Cooking
IQT +Profile Cooking allows operators to dial in both the desired core temperatures AND the degree of browning/crispness–IQT Logic does the rest.
Capabilities
+Profile is an automated cooking control program that is essentially “self-regulating in nature. That is, it adjusts cooking parameters in response to real-time conditions. Information on food and cabinet conditions is acquired by IQT Sensor and ClimaPlus Control. The IQT Logic intelligent software automatically and continu­ously analyzes this data, factors in the size of the roast or bird, and makes any adjustments in temperature and humidity necessary to ensure that the desired core temperature is reached at the same time as the ideal degree of browning.
Advantages
Five point sensing system of IQT Sensor insures accurate core and crust
temperatures, even with inaccurate probe insertion.
Select from seven degrees of browning (1-7 lighter/darker) to produce just the
type of outer skin or crust you want, automatically.
Constant automatic monitoring and adjustments produce the perfect cooking
cycle, resulting in moist flavorful meats, less shrinkage, and crisp skins without the dryness.
Updates and display of remaining cook time allows for better production
planning.
Get precise, consistent results every time regardless of meat size or size of load.
When to use
+Profile is most suitable for larger cuts of meat, such as a variety of pork, meat
loaf, turkey breast, chuck, brisket, veal roasts, and chicken.
For best results, cuts should be a minimum of 3 in. (7.6 cm) thick and at least
6 lbs. (2.7 kg).
Loads should be composed of similar sized cuts.
Cooking time should not be less than 30-40 minutes.
Select foods best sutied for Combi mode.
COOKING FUNCTIONS
+PROFILE
34
Operation and settings
Turn unit on.
Load oven rack.
Insert probe into thickest part of meat, or into central location of other types
of foods, on center oven rack.
NOTE: Be sure IQT Sensor is clean and cool prior to insertion.
DO NOT select cooking mode. Deactivate if mode has already been selected.
Press IQT key: +PROFILE appears in the adjacent display.
Press PROG/START key to activate program.
BROWN 4 appears in the temperature display. While the figure 4 is flashing,
use Central Dial to select desired level of browning from 1 to 7 (light to dark).
The IQT Sensor display shows a pre-selected core temperature of 162°F (72°C).
Press the IQT Sensor key and use Central Dial to set the desired core temperature.
Press PROG/START to confirm and initiate +Profile cooking.
During operation
Since all modes and humidity levels are enabled by the automated process, the
ClimaPlus window will display a blue-red bar and Moist Heat and Dry Heat modes will be active during the entire cooking cycle.
Cook time remaining is displayed and constantly updated during the latter stages
of the cycle.
Actual core temperature is displayed next to selected Done temperature.
The control panel is not accessible during operation to prevent automatically
selected settings from being accidentally altered. HACCP, Half Energy and Half Speed Fan functions can be selected during operation.
Opening the door during operation merely interrupts the cooking process.
When door is closed, all functions resume.
To stop any IQT program altogether, it is necessar y to turn off the unit.
NOTE: +Profile is a complete cooking program that automatically controls the cooking process. It cannot be used as a step in another program. However, IQT +Profile can be saved with specific settings as an individual custom program (See Programming, page 43.)
COOKING FUNCTIONS
IQT +PROFILE
continued
+PROFILE
BROWN 4
162
PROG
START
PROG
START
35
IQT +Low-T Cooking
IQT +Low-T Cooking offers operators a completely automated low temperature slow-cook solution for maximizing yield, color and consistency of large roasts.
Capabilities
+Low-T (low temperature) is a gentle cooking process designed for cooking large roasts over a long period of time. The completely automated cook cycle begins with a brief searing phase followed by a progressive lowering of the cabinet temperature until it matches the desired core temperature of the food. Over the remaining time, the actual core temperature of the slowly cooking meat continues to rise until it reaches the desired core temperature. At this point, the entire roast has reached the same temperature as its surrounding environment and can be held up to 24 hours.
Advantages
Slow, gentle process results in uniform cooking and prevents overcooking.
Mild cooking climate helps meat retain natural juices and flavor with minimal
weight loss and shrinkage.
Completely automated process compensates for load size and type of meat.
Rapid temperature drop after searing prevents overcooked exteriors. Steady
increase in core temperature results in uniform color and texture inside.
Automatic cook and hold process permits unattended, overnight cooking to
improve production efficiency and take advantage of lower energy rates.
NOTE: +Low-T is a complete cooking program that automatically controls the cooking process. It cannot be used as a step in another program. However, IQT +Low-T can be saved with specific settings as an individual custom program (See Programming, page 43.)
COOKING FUNCTIONS
+PROFILE
Desired core
temperature range
110-176°F
(45-80°C)
Searing temperature
range 266-392°F
(130-200°C)
Searing phase
Finishing phase Holding
Progressive temperature drop
Actual core temperature
Cabinet temperature
+LOW-T
36
Operation and settings
Turn unit on. DO NOT load yet.
DO NOT select cooking mode. Deactivate if mode has already been selected.
Press IQT key: (+PROFILE appears in the adjacent display.) Use Central Dial
to select +LOW-T.
Press PROG/START key to activate program. Pre-selected settings will appear
on the TEMPERATURE and IQT Sensor displays.
Press TEMPERATURE key and use Central Dial to enter desired searing
temperature–266-392°F (130-200°C).
Press IQT Sensor key and use Central Dial to enter desired core temperature–
110-176°F (45-80°C).
Press PROG/START to confirm and initiate +Low-T cooking.
Unit now begins preheating. When preheating temperature is reached, the
display will flash “LOAD” and buzzer will sound.
Load oven rack.
Insert IQT Sensor probe.
Close door to begin +Low-T cooking.
During operation
Since +Low-T cooking operates in Dry Heat mode, the ClimaPlus window will
display a red bar and Dry Heat mode key will be active during the cooking cycle.
After a period of time, the actual core temperature will appear in the display next
to done ” core temperature.
When the finishing phase begins, RIPENING appears in the TIMER display.
When the core temperature reaches the desired done temperature, the word
HOLDING appears in the TIMER display. This phase can be maintained for up to 24 hours.
The control panel is not accessible during operation to prevent automatically
selected settings from being accidentally altered. HACCP and Half Energy functions can be selected at the start of operation.
Opening the door during operation merely interrupts the cooking process.
When door is closed, all functions resume.
To stop the IQT +Low-T program prior to the holding phase, it is necessary to
turn off the unit. During holding phase, the program can be stopped simply by pressing the lit mode key to de-activate the mode.
COOKING FUNCTIONS
IQT +LOW-T COOKING
continued
PROG
START
PROG
START
37
IQT +Delta-T Cooking (with IQT Logic)
IQT +Delta-T Cooking offers operators a gentle, effective and completely auto­mated program for cooking hams and large marinated, salted or cured cuts of meat with the best flavor and yield.
Capabilities
+Delta-T uses IQT Logic to provide a gentle slow-cooking process in which the cabinet temperature rises slowly in direct proportion to the rise in the core temperature of the meat. The constant difference between the two is called the Delta-T or “difference in temperature. The operator enters both the “done” core temperature of the meat and the Delta-T number. The actual cabinet temperature rises quickly to forma mild crust that seals in juices and nutrients, then rises grad­ually pulling the temperature of the meat up gently to the desired core temperature.
Advantages
Creates a specific, gentle cooking process for hams and large cuts of marinated
or cured meat.
Process causes proteins to coagulate and meat fibers to swell, retaining juices
and nutrients.
Rapidly created outer crust seals in flavor and natural juices.
When core temperature is reached unit remains in holding phase.
Completely automated, no obser vation of the cooking process is necessar y.
Great for off-peak hours production.
NOTE: +Delta-T is a complete cooking program that uses IQT Logic to automati­cally control the cooking process. It cannot be used as a step in another program. However, IQT +Delta-T can be saved with specific settings as an individual custom program (See Programming, page 43.)
COOKING FUNCTIONS
+DELTA-T
180°F 130°F
Done cooking temperature Done core temperature
Actual core temperature
Cabinet temperature
Delta-T = 110°F
38
+DELTA-T
Operation and settings
Turn unit on.
Load oven rack.
Insert IQT Sensor probe.
DO NOT select cooking mode. Deactivate if mode has already been selected.
Press IQT key: (+PROFILE appears in the adjacent display.) Use Central Dial
to select +DELTA-T.
Press PROG/START key to activate program. Pre-selected settings will appear
on the TEMPERATURE and IQT Sensor displays.
Press TEMPERATURE key and use Central Dial to enter desired Delta
temperature–68-140°F (20-60°C).
Press IQT Sensor key and use Central Dial to enter desired core
temperature–110-210°F (45-99°C).
Press PROG/START to confirm and initiate +Delta-T cooking.
During operation
Since +Delta-T cooking operates in Moist Heat mode, the ClimaPlus window
will display a blue bar and the Moist Heat mode key will be active during the cooking cycle.
The actual core temperature will appear in the display next to “done” core
temperature.
The control panel is not accessible during operation except for the following
functions (may depend on model.)
IQT, HACCP (all LCS and LCG models)
Half Energy (all LCS Electric models)
Half Fan Speed (all LCS Electric models and the LCG-40 Gas)
Opening the door during operation merely interrupts the cooking process.
When door is closed, all functions resume.
To stop the IQT +Delta-T program altogether, it is necessary to turn off the unit.
NOTE: For a Delta-T Cooking program without IQT Logic see “Special Functions: Delta-T Cooking, page 40.
COOKING FUNCTIONS
IQT +DELTA-T COOKING
continued
PROG
START
PROG
START
+ROASTCHI
COOKING FUNCTIONS
39
P r eset Program Library
Built-in programs for cooking, preheating, rethermalization and cleaning.
The IQT key can be used to access a library of preset programs based on manufacturer’s research and testing. The library includes a host of cooking programs for basic items. There are also programs for efficient preheating, rethermalizing plated portions, and a cleaning program.
Operation
Turn unit on.
Load oven rack.
DO NOT select cooking mode. Deactivate if mode has already been selected.
Press IQT key: Use Central Dial to select desired preset program.
NOTE:The three IQT programs are first in order of display, followed by a series of asterisks. Preset programs are next, each preceded by a single asterisk.
Press PROG/START key to activate program.
+ROASTCHI
Special Function: Half Energy
A feature that efficiently reduces the unit’s electrical operating requirement to about half the energy nor mally used.
Advantages
Saves on energy costs when operating during hours of peak power rates.
Helps control slow cooking process at lower temperatures.
NOTE: In most cases, cooking times will be longer when using HALF ENERGY feature.
Operation
SELECT any mode.
Select desired cooking TIME (adjusted for Half Energy), TEMPERATURE
and/or probe “done temperature.
E1/2 ON
Available on all LCS electric models only
PROG
START
DELTA ON
DELTA OF
40
Special Function: Delta-T
(without IQT Logic)
A special program for slow-cooking large curd or mari natedroasts for best flavor and yield.
NOTE:This function does NOT use IQT Logic. For detailed description of capabilities and advantages of Delta-T Cooking, see IQT +Delta-T Cooking, page 37.
Operation
SELECT desired mode. Insert IQT Sensor probe.
Press IQT key. Use Central Dial to select DELTA. DELTA OF appears in the
display.
Press PROG/START key to activate function. DELTA ON appears in display.
Press IQT Sensor key and use Central Dial to enter desired core
temperature–65-210°F (20-99°C).
Press TEMPERATURE key and use Central Dial to enter desired Delta
temperature–35-110°F (20-60°C).
DELTA
E 1/2 OF
E 1/2 ON
210oF E
Press IQT key. Use Central Dial to select Half Energy.
Display will read E 1/2 OF”.
Press PROG/START key to activate function. Display will change to E 1/2 ON”.
When Half Energy is in operation, the letter E will appear at the right in the
Temperature display.
COOKING FUNCTIONS
Half Energy
continued
PROG
START
41
HACCP
1.60
COOKING FUNCTIONS
Special Functions: HACCP Interface
A special capability that records, prints and/or transmits actual cooking data for conformance with HACCP procedures.
The ClimaPlus Combi is equipped with a serial interface to output key cooking data, such as core temperature progression, cabinet temperature, start and end times, etc. This data can be printed out directly in report form or downloaded to a PC environment. HACCP requires CCP (Critical Control Points) reports to be archived.
Set Up
First, connect a printer or PC to your ClimaPlus Combi using a standard serial cable. The combi serial port is located on the underside of the unit near the front. Once connected, follow the instructions below to begin recording data.
Recording data
Be sure mode and cooking parameters are selected. Recording can only take place when using probe cooking. Be sure food probe is inserted.
Press IQT key. Use Central Dial to select HACCP.
Press PROG/START key to activate function. A flashing dot appears in the
display to indicate that data is being recorded.
Close cabinet door and begin cooking.
The function stops at the end of the cooking cycle, or if the unit is turned off
for longer than 4 seconds. Data recording can be terminated prior to completion
of the cooking process by pressing active mode key to deactivate.
Outputting data
Data can be output to the following devices:
A standard printer equipped with a serial RS232 interface that can be set
to the specified transmission format.
Any PC with Windows 95 or higher operating system. Windows 95 and 98
include a terminal program in the Hyper Terminal folder within the Accessories program group. After launching the "Hypertrm" application program, the following settings must be made:
HACCP
PROG
START
Windows 95 and Windows 98
1. Create a new connection in Hyper Terminal and name it “HACCP.
2. In the Phone Number dialog box, click on Connect Using and select either COM 1, COM 2, ...OR COM n, depending on which of the PC’s serial interfaces is connected to the combi steamer. Click “OK.
3. In the Properties dialog box that appears, select the following settings:
Bits per second:9600 Data Bits: 8 Parity: None Stop bits: Flow control: None Click OK.
4. In the Hyper Terminal main window, click File and select Properties from the pull down menu.
5. Click on the Settings tab and select VT-100 from the Emulation menu. Click OK.
6. In the Hyper Terminal main window , click Transfer and select Capture Text.
7. A name must be given for the text file. You must include the “txt with your file name. Click OK.
For Windows NT 4.0 or higher and Windows 2000, please refer to the
appropriate operating manuals or consult your organization’s network technical support personnel.
Evaluating data
Data downloaded from the combi includes a header, the temperature data, and an end character. Tabs separate the individual temperatures in a data record. This makes it easy to import data into suitable spreadsheet or database software.
A “data record is comprised of the following three values:
1. Core temperature of food
2. Cabinet temperature
3. Number of minutes elapsed since the start of recording.
The current date and the start time (of the cooking process) should be entered
(manually) via the PC.
A graphical display of temperature progressions has proved useful.
Always ensure that once cooking is over, a clear signal is sent to the staff
operating the unit that the cooking process parameters have been adhered to (i.e. that the core temperature has been reached).
A “non-temperature data record can be identified by the fact that the first
character is a semicolon.
The batch number is automatically numbered from 0 upwards for each
cooking cycle.
The temperature data measured is sent at 60-second intervals.
The termination time is output in minutes and seconds.
The end character consists of the message end***.
COOKING FUNCTIONS
42
HACCP Interface
continued
43
P rogramming
Programming capabilities of the ClimaPlus Combi allow operators to:
Create custom cooking programs
Incorporate IQT functions into custom programs
Lock/Unlock programs
If you are not already familiar with the LCS control panel, please review page 8 before attempting to program your unit.
Capabilities
Memory
Up to 99 total cooking programs are available to the operator. Up to 9 steps
(sets of parameters) are available for each cooking program.
An additional 11 programs have been pre-set at the factory (see Preset Program
Library, page 39.) These include 10 programs for common menu items as well as a cleaning program.
ClimaPlus Combis also feature 3 IQT Logic programs (See +Profile Cooking,
+Low-T Cooking, and +Delta-T Cooking, page 37.)
Control
Automatic–Unit begins operation when PROG/START key is pressed.
Unit shuts down when last program step has been completed.
Manual Override–Program operation can be interrupted at any time by simply
selecting or setting a new value or special function. The new value or function affects the cooking process only in the step in which the program was overridden. Overriding the program DOES NOT cancel it. When the new value or function is achieved, and/or that step of the program is completed, program operation continues with the next programmed step, or shuts down unit if program is complete.
Program Lock–Cooking programs can be locked to prevent any unauthorized or
undesired changes to the programs. If programming is locked out, only stored programs will be displayed.
COOKING FUNCTIONS
PROG
START
44
12/2
12
LASAGNA
PREHEAT
Programming the ClimaPlus Combi
To create custom cooking programs:
Turn unit on and open door.
Press the PROG/START key. The display shows the current program
number/name.
Select the desired program number (1-99) using Central Dial. Flashing numbers
indicate available program numbers.
NOTE: Most cooking programs require preheating. To make preheating the first step in a program, follow these steps.
Select the desired Cooking Mode for preheating (this begins the first program
step.) The selected program number and the current program step are displayed (e.g. 12/1, indicating program #12, step 1).
Select desired preheating cabinet temperature.
Press and hold TIMER key until PREHEA T is displayed.
Select a Cooking Mode to save this step and activate step two.
Continue with step two by selecting additional parameters, such as cooking
temperature, probe “done temperature, additional functions, etc. For each parameter or function, press the appropriate key and use the Central Dial to dial in the desired value.
To move on to the next step in the program, select a cooking mode. It can be
the same mode or a different one. This saves the cooking parameters of the previous step and activates the next program step (e.g. 12/2).
When all steps have been entered in this manner, press PROG/START to
save settings and store the program.
To review the program, press PROG/START repeatedly to step through the
program until the display is blank.
Close door.
COOKING FUNCTIONS
Programming
continued
12/1
PROG
START
PROG
START
45
12
P2
PI
12
PIE A
PIE A
PIE A
Naming programs:
You may wish to name programs in order to identify them faster and more reliably. Names can contain up to eight characters.
Press the PROG/START key. The display shows the current program number.
Select the desired program number using the Central Dial.
Press and hold the IQT key until the cursor flashes under the first digit position
in the display. The Central Dial will now run through all alphanumeric characters. Select the first character of the program name and press IQT key to confirm. The cursor then flashes in the next position to the right.
Continue selecting letters and/or numbers in this manner.
To save the name, press and hold IQT key until the underscore disappears.
Programs are stored by name or by number. Named programs will be stored in alphabetical order and will appear first in the display, followed by the numeric dis­play. Named programs are no longer associated with program numbers. Program numbers which have been given names no longer appear in the numeric display.
Tip:
If you use the same name more than once, ClimaPlus will index them by number.
Always enter letters of name before any numbers you may wish to include, e.g.,
Chicken 1, Chicken 2, etc.
Working with programs
To run a saved program
Turn unit on.
Press the PROG/START key and select the desired program using the
Central Dial.
Press the PROG/START key again to begin the program.
Once all cooking steps have completed, signal will sound and unit will shut
down automatically.
To make changes to a saved program
Press the PROG/START key and select the desired program using the
Central Dial.
Press PROG/START until the step you wish to change changed is displayed.
Make desired changes by selecting new mode, temperatures, time and/or any
additional functions.
To save changes press and hold the TEMPERATURE and PROG/START
keys simultaneously until the program number or name begins flashing. This confirms that changes have been saved.
COOKING FUNCTIONS
Programming
continued
PROG
START
PROG
START
PROG
START
PROG
START
PROG
START
PROG
START
20
+PORKTND
+PROFILE
46
*CC CHICK
14
CC CHICK
NOTES:
Any cooking parameter in any step of a program can be changed. However, once
saved, no step can be added or removed.
Factory Preset Programs (See Library of Preset Programs, page 39) CANNOT
be edited. However, they can be copied and saved as a custom program, and then edited. See Copying programs” below.
Copying programs
Preset programs can be copied and saved as custom programs and edited as desired. IQT Logic programs with specific values can be copied and saved as custom programs. They cannot be edited.
To copy Preset programs:
Press the IQT key and use the Central Dial to select the desired program to copy.
Each Preset program is preceded by an asterisk.
Press PROG/START once to activate program.
Press and hold IQT key until flashing (available) program number appears in
program display. You may now accept this number for use or select any other available number using the Central Dial.
Press the IQT key. All displays go out, indicating that the Preset program has
been saved into the custom program memory. The Preset program name will now appear in the program display WITHOUT the asterisk. Access, rename and edit this program as desired, following the procedures above.
To copy an IQT Logic program:
Press the IQT key and use the Central Dial to select the desired IQT Logic
program to copy.
Follow procedures (pages 33-37 ) to enter required settings.
DO NOT Press PROG/START to confirm/activate.
Instead, press and hold IQT key until flashing program number appears in
program display. You may now accept this number for use or select any other available number using the Central Dial.
Press the IQT key again. All displays go out, indicating that the IQT Logic
program has been saved into the custom program memory. The IQT program name will now appear in the program display WITH the
+
. Access and rename
this program as desired, following the procedures above.
NOTE: IQT Logic programs, while appearing to contain many changes or steps are nevertheless integral–they are NOT themselves composed of separate programming steps that may be edited. They do not work this way. When in operation, they respond with changes to real-time conditions in the cabinet. While these programs cannot be edited, they MAY be inserted whole as an individual step in a custom program.
Changes must be saved before moving to the next step of the program.
COOKING FUNCTIONS
Programming
continued
PROG
START
*********
*L*******
C********
PROG LOCK
47
PIE A
12
To insert IQT Logic programs as custom program steps:
Follow the procedures for creating a new program or changing a saved program. When the desired step is displayed, follow the procedures above for copying an IQT Logic program. The program name (with the required settings entered) will appear as a step in the current program.
To delete a program
Press the PROG/START key and select the desired program using the Central Dial.
Press any cooking mode key.
00:00 appears on the display.
Press and hold PROG/START for five seconds. The program number will begin
to flash indicating that the program has been deleted and that the number is now available. If you are deleting a named program, the text disappears and the original program number flashes in its place.
Program Lock and Passwords
To lock or unlock the programming function of the unit, a password must be entered. The password that has been pre-programmed at the factory is: CLIMA
+
This password can be changed later.
To lock or unlock programming
With unit on and door open, press any Cooking Mode key.
Press the IQT key and select LOCK or UNLOCK using the Central Dial.
Press and hold the PROG/START key until the TIMER display shows a line of
asterisks, with the cursor flashing under the first asterisk position.
Enter password CLIMA+by using the Central Dial to select a character and
by pressing the TIMER key after each character to save it and advance the cursor. Do this carefully, as the display shows only the letter being entered. For security purposes, the other positions remain visible only as asterisks.
When the complete password is entered, press the TEMPERATURE key to
toggle between PROG LOCK and UNLOCK.
Press PROG/START key to save the desired setting.
NOTE: After starting a program when programming is locked, it is not possible to change any function of the program. The selected program can only be cancelled by turning the unit off.
COOKING FUNCTIONS
PROG
START
PROG
START
PROG
START
PROG
START
48
@
@@@@@@@@
UNLOCK
To Change Programming Password
IMPORTANT: If the pre-programmed password is changed and then forgotten,
it is only possible to deactivate the program locking system with a total reset procedure. If a total reset must be performed all custom programs in the system
will be lost.
A password may consist of (1 to 8) letters, numbers and symbols. To change the password, follow the procedures for Locking/Unlocking above to
enter the current password. If no new password has been entered, this will be the factory set password: CLIMA
+
When the complete password is entered, press the TEMPERATURE key to
toggle from PROG LOCK to UNLOCK.
Turn the Central Dial. The TIMER display shows the flashing cursor and
asterisks. Enter the new password in the same manner as above.
When finished, press the PROG/START key to submit the new password.
As a security measure, the TIMER display responds with a line of @ symbols, with the first symbol flashing. Re-enter the new password to confirm.
Be sure PROG LOCK/UNLOCK is set to desired status.
Press the PROG/START key to save the new password and program locking
status.
Time, Temperature and Language Settings
The ClimaPlus®Combi offers the operator the choice of:
Time formats:
Military (24:00)
Standard time (AM:PM)
Languages
English
Spanish
Portuguese
French
German
User choice
Temperature scales
Fahrenheit
Celsius
COOKING FUNCTIONS
*
********
PROG
START
PROG
START
49
AM:PM
ENGLISH
FAHRENH
WATER
WATER
To specify settings
Turn unit on. If unit is already on, switch off and turn on again.
Press TEMPERATURE and TIMER keys simultaneously for about 10 seconds
or until the TIMER display reads “24:00 or “AM:PM”.
Select the desired time format using the Central Dial.
Press the TEMPERATURE key to save the selected time format and activate the
next setting, language selection. Select the desired language using the Central Dial.
Press the TEMPERATURE key to save language selection and move to the next
step, temperature selection. Select CELSIUS” or FAHRENH” using the Central Dial.
Press PROG/START to save all selections and exit.
NOTE: If you have chosen the USER language selection, DO NOT exit with PROG/START.
To convert text commands to User language:
Press TEMPERATURE key again to begin converting text commands. The first
term appears in English (default language) in the temperature display. The term is repeated in English in the program display with a flashing cursor under the first character.
Using the Central Dial select the letters for the desired spelling of the term in the
user’s preferred language. Press the IQT key after each letter selection to confirm it and advance the cursor.
When done, press the TEMPERATURE key to access the next term and
proceed in this manner.
Press PROG/START at any time to save all entries and exit User language text
conversion.
Setting the clock
The unit’s clock can be set to display continuous operation or real time. Automatic start-up time can also be set.
Be sure unit is on and NO cooking mode is selected
To display continuous operation:
Press the TIMER key once to display 00:00 A:M.
Press and hold TIMER briefly to display DURA TION”.
COOKING FUNCTIONS
PROG
START
PROG
START
50
9:15 AM
REALTIME
STRTTIME
To set real time:
Press and hold the TIMER key for about 10 seconds, skipping the start-time
display. Display shows REALTIME”.
Use Central Dial to set correct real time.
Press TIMER once to store real time.
To set automatic Start Time:
Press TIMER key for about 5 seconds, skipping the duration display. Display
shows STRTTIME”.
Use the Central Dial to set the desired starting time.
Press TIMER once more to store starting time.
NOTE: Start Time is stored in memory and remains until changed. It does not have to be entered every day.
To operate unit with Start Time:
Follow proper procedures for entering cooking parameters, selecting the first step
of a cooking program, or selecting IQT Logic programs and entering required values. DO NOT START cooking process.
Activate Start Time by pressing and holding first the TIMER key and then the
PROG/START key. Hold both keys for a few seconds until unit goes into standby mode.
While unit is in standby mode, waiting to switch itself on, the current time and
the Start Time alternate in the display.
COOKING FUNCTIONS
PROG
START
51
Additional functions: S team I njection
Steam Injection is a keypad function enabled in Dry Heat mode that, when activated, sprays a four-second burst of water onto heating elements, creating an immediate and brief humidified environment in the cooking cabinet.
Advantages
Improves rising and browning of dough.
Adds slight glaze to pastries.
Keeps foods, and especially skins and crusts from dehydrating.
Additional control for fruit, meat pastries and other items with varied textures,
densities and consistency.
Tips
Use Steam Injection sparingly. If ongoing humidity is desired, use Combination
Mode or Forced Steaming.
Use early in the baking process to improve dough and pastry rising.
Can be used in all program steps that use Dry Heat between 248°F and 482°F
(120-250°C). When programmed, a four-second burst occurs every two minutes.
Operation and settings
Steam Injection can only be activated when cooking in Dry Heat mode.
Cooking temperature must be set between 248°F and 482°F (120-250°C).
NOTE: Steam Injection will not operate until cabinet temperature is 248°F (120°C) or higher.
To activate, press and hold STEAM INJECTION key. Hold for up to four
seconds per burst. Release to stop at any time.
Repeat as desired.
COOKING FUNCTIONS
52
Additional functions: Half Speed Fan
Half Speed Fan is a keypad function that reduces fan speed by one-half to produce less turbulence in the cooking environment.
Advantages
Maintains a gentle cooking environment for light pastries, custards and other
items with exposed fillings.
Less turbulence when rising or finishing doughs and pastries.
Maintains even heating and browning.
Tips
Use Half Speed Fan when baking large braided or shaped loaves.
Create a gentler cooking environment by combining Half Speed Fan with the
Pulse Fan function (see below).
Half Speed Fan may be used in any cooking program.
Operation and settings
Half Speed Fan can be used in any cooking mode, temperature setting, and at
any time during the cooking process.
To activate, press the HALF SPEED FAN key. Green LED on key will light.
Press again to return to normal fan speed.
Pulse Fan is a keypad control feature that, when activated, causes the fan to run intermittently–on for 10 seconds and then off–at intervals.
Advantages
Promotes gentle, even cooking at lower temperatures.
Conser ves energy over longer cooking times.
Enables consistent, quality results when slow-cooking.
Perfect control feature for slow cooking large cuts of meat, such as leg of lamb,
beef roast, cured ham, leg of veal, pork roast, whole turkey.
Advantages of slow cooking
Meat tenderizes as it cooks.
Meat retains moisture and natural juices resulting in less shrinkage and weight
loss. This means more portions served per uncooked pound.
Cook and hold overnight with no supervision necessary.
COOKING FUNCTIONS
Additional functions: Pulse Fan
Available on all LCS electric models and the LCG-40
COOL DOWN
53
Tips
When cooking large roasts, use Pulse Fan when core temperature reaches
140°F (60°C).
The existing heat in the cabinet and from the bulk of the roast is enough to
complete the cooking process with Pulse Fan operation.
Pulse Fan can be programmed at any stage of the cooking process.
For low temperature cooking, experiment by using Pulse Fan along with Half
Speed Fan and/or Half Energy features to create a gentle cooking environment.
Operation and settings
Pulse Fan can be used in any cooking mode, temperature setting, and at any
time during the cooking process.
To activate, press the PULSE FAN key. Green LED on key will light.
Press again to return to normal fan operation.
COOKING FUNCTIONS
Additional Functions: Pulse Fan
continued
Cool Down is a keypad convenience function that enables the fan to continue operating when the door is open. This dissipates heat quickly.
Advantages
Achieve rapid reduction in cabinet temperature when switching to a lower
cooking temperature from preheating or from a higher cooking temperature.
Saves time for efficient operation.
Prevents overcooking, especially with shorter cooking times.
Operation and control
Cool Down can be used in any cooking mode, at any temperature setting, and
at any time during the cooking process.
Unit must be in operation with door closed.
Press the Cool Down key. Green LED on key will light. OPEN DOOR
appears in display.
Open door with care. COOL DOWN appears in display.
Actual cabinet temperature appears with flashing digits in Temperature display.
NOTE: Always cool unit down 20-30° below desired cooking temperature. Press cool down to de-activate cool down function.
Additional functions: Cool Do wn
OPEN DOOR
Cleaning
Your ClimaPlus®Combi MUST be cleaned at least once a day to ensure proper sanitation and continued trouble-free operation. Daily cleaning can be accomplished in two ways:
Conventionally using Moist Heat mode and/or pre-set cleaning program.
With the CleanJet automated cleaning feature.
Conventional Cleaning
All ClimaPlus Combis are equipped with a preset cleaning program and a built-in retractable hand shower for rinsing. The unit uses its own built-in water supply, plus heat and steam from Moist Heat mode operation to do most of the work.
For best results with conventional cleaning, use Henny Penny Oven and Grill Cleaner and follow the procedures outlined below:
1. Leave hinged racks or mobile oven racks and grids. Stainless steel containers may also be left in the cooking cabinet.
2. Allow cooking cabinet to cool down below 130°F (55°C).
3. Spray all interior cabinet surfaces (even behind the pivoted air baffle) as well as oven rack, grids and pans thoroughly with Henny Penny Oven and Grill Cleaner. (Goggles and gloves should be worn when using chemicals.)
To initiate factory pre-set cleaning program (about 40 minutes)
NOTE: If you do not wish to use pre-set cleaning program, skip steps 4-6.
4. Press IQT key
5. Select *CLEAN using central dial.
6. Press PROG/START and skip steps 7-9.
7. Let cleaner act for approximately 20 minutes.
8. Select Moist Heat mode.
9. Select TIMER and set for 15 minutes.
10. Repeat process for heavily soiled cabinet.
11. Rinse thoroughly with built-in hand shower.
NOTE:To activate the hand shower water flow, pull hose to full extension and release to rest position. Press spray gun button.
54
+CLEAN
OR
PROG
START
STEP 0
CLEANJET
55
U sing CleanJet
®
ClimaPlus Combis are now equipped with CleanJet, a unique, patented system that cleans and rinses the cabinet interior with no labor or supervision whatsoever.
The CleanJet cleaning arm
The special CleanJet arm attaches to the inside of the cabinet and lays down a powerful vortex” spray pattern that works in conjunction with high heat and timed cleaning stages to completely clean and rinse the combi.
Dispensing detergent and rinsing agent
CleanJet detergent and rinsing agent are dispensed automatically in the proper
amounts, depending on the cleaning cycle selected.
On base-top models, a special drawer dispenser slides out from under the unit
to be filled, then slides back under to engage and store.
On floor models, detergent and rinsing agent containers are connected with a
hose directly to the ClimaPlus.
To begin the automatic CleanJet cleaning:
1. Be sure unit is turned off and cabinet has cooled to 150°F (83°C) or below.
2. For base top units, be sure dispensing drawer has sufficient detergent and rinsing agent. For models 20 and 40, be sure detergent and rinsing agent containers are properly connected with the connecting hose to the appropriate nozzles located under the front edge of the unit to the left of the handshower.
3. Connect CleanJet arm to the fixture inside the cabinet on the back wall. Floor models 20 and 40 require two CleanJet arms (included.)
DO NOT place soiled racks, pans or grids in cabinet for cleaning
when using CleanJet. CleanJet arm could be damaged during operation.
4. Close door.
DO NOT open door while cycle is in progress. CLEANJET
CYCLE WILL NOT STOP IMMEDIATELY.
5. Turn unit on. CLEANJET appears in the TIMER display. STEP 0 or STEP 1 appears in the IQT display.
6. Use the Central Dial to select the desired cleaning stage based on the condition of the cabinet. CleanJet offers a total of seven cleaning programs, steps 0-6, and QUICK”.
NOTE: If you do not find “Step O or Step 5” and Step 6 in the display, it is because they must first be copied into the CleanJet menu by means of another method of access. This will only need to be done once. To make Step 0 or Steps 5 and 6 available in the CleanJet display, follow the procedure below:
CLEANING
CLEANJET
+STEP56
ACTIV
CLEANJET
24:00
56
Unit must be on, WITHOUT CleanJet arm(s) attached, and no mode selected.
Press TEMPERATURE and TIMER keys simultaneously for about 10 seconds
or until the TIMER display reads “24:00 or “AM:PM”.
Press TEMP key three times. Either “+STEP 0”, “STANDARD” or
+STEP56will appear.
Use Central Dial to select desired step.
Press PROG/START. All displays go out indicating program was copied and
saved to CleanJet location.
Turn unit off and follow the procedures above beginning with step 2.
7. Press PROG/START to begin cleaning cycle. “ACTIV and CLEANJET
shows in the display. Remaining cycle time shows in the TIMER display. See charts on page 57 for duration of each cleaning program.
8. Unit shuts off automatically when cycle is complete.
Tips
To stop the cycle for any reason, it is necessary to switch the unit off.
If the unit is turned off for any reason during cleaning cycle (or if power to the
unit is interrupted,) cycle will be suspended. When the unit is switched back on (or when power is restored,) the cleaning cycle will NOT continue. Instead, ABORT is displayed. Press PROG/START to run through a short rinsing cycle to clear the cabinet of any remaining detergent and/or loose debris. Operator may now repeat entire cleaning cycle.
Hand cleaning accessibility
The hinged racks can be removed for cleaning by lifting up on the racks,
swiveling them inward, and lifting them off their mountings.
If using the mobile oven rack system, roll the rack out of the unit and remove
the guide frame from the bottom of the unit by lifting it upward out of its mountings.
The air baffle, covering the left side of the interior cabinet, provides even airflow and
protects operator from heating elements and fan. To open the baffle for cleaning:
1. Turn unit off and disconnect electrical power to unit.
2. Swivel left hinged rack inward. (If using mobile oven rack, remove rack and guide frame.)
3. Using a flat-head screwdriver or a coin, turn the two quick fastening locks one-quarter turn counterclockwise. Baffle will swing open for cleaning.
NOTE–floor units have 2 air baffles that open in this manner.
Safety protection (gloves, goggles, etc.) is required when working with cleaning products. Please refer to cleaning product guidelines before use.
CLEANING
PROG
START
57
Cycle time in minutes.Detergent and rinse values in ounces.Water values in gallons.
CLEANING
CleanJet
®
continued
Tables of cycle times and water usage for CleanJet
®
.
Guide to selecting cleaning level.
Cycle Level 0 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Quick
Duration (min) 23 24 52 70 89 108 127 13
Model 6 Detergent (oz) 3 7 10 20 27 47 57 14
Rinse Aid (oz) 17 17 17 17 17 17 17 17 Water (gal) 8 12 23 35 48 60 72 14
Model 10 Detergent (oz) 3 7 14 24 37 54 68 20
Rinse Aid (oz) 17 17 17 17 17 17 17 17 Water (gal) 8 12 23 35 48 60 72 14
Duration (min) 39 42 61 82 103 124 145 13
Model 1020 Detergent (oz) 14 24 34 44 54 71 84 41
Rinse Aid (oz) 34 34 34 34 34 34 34 34 Water (gal) 16 21 35 54 73 92 111 21
Model 20 Detergent (oz) 7 10 17 37 51 68 84 24
Rinse Aid (oz) 30 30 30 30 30 30 30 30 Water (gal) 17 22 36 55 76 95 115 22
Model 40 Detergent (oz) 20 41 51 68 84 112 135 61
Rinse Aid (oz) 51 51 51 51 51 51 51 51 Water (gal) 17 22 37 58 79 100 121 22
Cycle time in minutes.Detergent, rinse and water values in liters.
Cycle Level 0 Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Quick
Duration (min) 23 24 52 70 89 108 127 13
Model 6 Detergent 0.1 0.2 0.3 0.6 0.8 1.4 1.7 0.4
Rinse Aid 0.5 0.5 0.5 0.5 0.5 0.5 1.5 0.5 Water 31 44 88 134 180 226 273 52
Model 10 Detergent 0.1 0.2 0.4 0.7 1.1 1.6 2 0.6
Rinse Aid 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Water 31 44 88 134 180 226 273 52
Duration (min) 39 42 61 82 103 124 145 13
Model 1020 Detergent 0.4 0.7 1 1.3 1.6 2.1 2.5 1.2
Rinse Aid 11111111 Water 16 21 35 54 73 92 111 81
Model 20 Detergent 0.2 0.3 0.5 1.1 1.5 2 2.5 0.7
Rinse Aid 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 Water 65 85 138 207 287 360 435 85
Model 40 Detergent 0.6 1.2 1.5 2 2.5 3.3 4 1.8
Rinse Aid 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Water 65 85 140 220 300 380 460 85
Level 0 Very small amounts of crumbs from bakery products. Level 1 Cooking vegetables and fat-free products. Level 2 Minimal level of grease and oils from mixed loads of vegetables and meat. Level 3 Moderate amounts of grease and oils from roasted meats and vegetables. Level 4 Heavier amounts of grease and oils from roasted meats and products heavy in starch,sugar and
marinades.
Level 5 High amounts of grease and oils from roasted meats and vegetables. Level 6 Excessive amounts of grease and oils from multiple loads of grilled or roasted meats and products
heavy in starch, sugar and marinades.
Quick Fast program for intermediate rinsing during heavy use. Use throughout the day to remove heavy
levels of grease and deposits that cause scorching and odors.
LIMSCAL
58
*******
CALCCHECK
Descaling maintenance
Limescale deposits occur naturally inside the steam generator. Time, heavy use and hard water conditions result in a gradual build-up of these deposits, eventually affecting the performance of the ClimaPlus Combi. Periodic, professional cleaning of the steam generator (descaling) must be performed by a certified and properly trained technician to ensure peak performance of your ClimaPlus Combi.
Auto Flush
Auto Flush is an automatic feature of ClimaPlus that drains and flushes the steam generator on a regular basis in order to keep the unit operating reliably between descalings. While it extends the time between service calls, it is not meant to make descaling unnecessary.
IMPORTANT: Descaling should ALWAYS be performed by a certified and properly trained technician.
CDS CalcDiagnosis
Henny Penny ClimaPlus Combis are equipped with a special feature called CDS CalcDiagnosis that monitors limescale build-up and warns the operator when descaling is necessary. This is a particular advantage because the CalcDiagnosis system permits the operator to schedule descaling not just regularly or randomly, but when needed.
To check the level of limescale deposits at any time:
To check the level of limescale deposits at any time:
Press any Cooking Mode key.
Press IQT key and use Central Dial to select LIMSCAL”.
Press and hold PROG/START key. A horizontal line of asterisks will appear
in the IQT display, indicating graphically the relative build-up of deposits in the steam generator.
When deposits reach 80 percent of the permissible level, the “CALCCHECK
warning display flashes for two minutes. When the level reaches 90 percent, the warning remains on without flashing for two minutes.
Service call for descaling should be scheduled within 14 days.
When descaling has been completed the display with the horizontal line of
asterisks must be reset. (Should be reset by the service technician.)
CLEANING
CALCCHECK
PROG
START
59
Installation
Refer to the following pages for important information regarding the installation of LCS and LCG ClimaPlus Combis. It is recommended that installation be accomplished by a certified and properly trained technician.
NOTE: When installing a ClimaPlus combi, humidity calibration must be performed. This process takes approximately 45-60 minutes. (page 62)
Site, leveling
1) Check for any transport damages. Should there be any signs of transport
damage immediately inform your dealer/freight forwarder.
2) Check installation site. Check entrance clearance.
Minimum entrance space needed without pallet: Model 6 & 10: 351⁄2 in. (902 mm)
Model 1020: 495⁄8 in. (1262 mm) Model 20: 397⁄8 in. (1012 mm) Model 40: 521⁄2 in. (1332 mm)
Floor at installation site must be level.
Cold water line in place. (page 63)
2 in. (50 mm) drain connection installed.
Max. drain height for floor units: 4 in. (100mm)
Electrical power supply/protective measures installed and sized correctly.
(page 60-61)
3) Remove all cartons, packing materials, documents etc. from the interior cabinet.
4) Remove grid shelves/trolley from cabinet.
5) Take unit off the pallet.
Moving unit without pallet: Sizes 6, 10, 1020 (Fig. 1)
Moving unit without pallet: Sizes 20, 40 (Fig. 2)
Minimum clearance sides and back: 2 in. (50 mm)
Service clearance, left side: 20 in. (500 mm)
Clearance for door opening: Model 6 & 10: 20
1
2
in. (521 mm)
Model 1020: 29
1
2
in. (749 mm)
Model 20: 28
3
4 in. (730 mm)
Model 40: 30
3
4
in. (781 mm)
Fig. 1
Fig. 2
60
Unit weights:
LCS 6: 270 lbs.(123 kg) LCG 6 335 lbs. (152 kg) LCS 10 334 lbs. (152kg) LCG 10 384 lbs. (174 kg) LCS 1020 484 lbs. (220 kg) LCG 1020 584 lbs. (265 kg) LCS 20 686 lbs. (312 kg) LCG 20 798 lbs.(362 kg LCS 40 972 lbs. (442 kg) LCG 40 888 lbs.(403 kg)
6) Installation models 6, 10, 1020
Place floor stand at the installation place and level by adjusting legs. (Fig. 3).
Minimum clearance required to neighboring equipment or walls. (page 59)
Place the unit on top of the stand. The units legs must be centered on
the locating pins of the stand (Fig. 4).
Unit must be level (Fig. 5).
7) Installation models 20, 40
The unit must be secured against shifting on the floor by means of floor
fixtures (Fig. 6). If floor fixtures are glued to the floor (use polyurethane glue or similar), remove all grease from the floor first.
Place the unit at its final location and level by adjusting legs. (Fig. 5).
Minimum clearance required to neighboring equipment or walls. (page 59)
The area of floor under the unit where Mobile Oven Racks will roll in
must be level or door will not seal. (Fig. 7).
Electrical
8) Electrical connection
Connect the unit only according to the information given on the data plate.
Observe all regulations of your local Electrical Code.
The appliance may only be connected by a licensed electrician.
Each appliance requires an independent fused power supply line.
Connection via GFI circuit breaker is advisable.
On-site installation: provide accessible all-pole disconnection device with
minimum of
1
8 in. (3 mm) contact gap (not required for 120v gas units.)
Connect appliance to ground.
Special voltages on request. Circuit diagram is located behind the operator
panel.
Connected load for electric units:
INST ALLATION
continued
Model KW
Amps
208v 3Phase 240v 3 Phase 208v 1 Phase 240v 1 Phase
LCS-6 10 28 24 48 42 LCS-10 19 53 45.8 LCS-1020 31.5 87.5 75.9 LCS-20 38 105.6 91.5 LCS-40 63 175.1 151.8
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
61
Choose conductor size according above tables and your local regulations.
IMPORTANT
Gas units are voltage specific. Supply voltage must match voltage rated on data plate.
Gas units are supplied with grounded power cord and plug.
Electric units are NOT supplied with power cord.
To connect power supply for electric units, models 6, 10:
Open the operator panel. (Fig. 8)
Insert power cord through cable inlet under left side of unit to desired
length and secure the cable connection tight. (Fig. 9)
The circuit diagram is located behind the control panel.
To connect power supply for electric units, models 1020, 20, 40:
Access power connection terminals by removing left side panel.
Insert power supply cable through cable inlet under left side of unit to desired
length and secure the cable connection tight. (Fig. 9)
Connect supply wires as follows:
Gray terminals: L1, L2, L3, phase sequence
does not need to be observed Blue terminal: Neutral (if applicable) Yellow/Green terminal: Ground
IMPORTANT
In some areas Henny Penny Electric Combis are shipped set up for 240 volts, but can be converted to 208 volt operation. If conversion is necessary the unit must be reset and calibrated.
Convert from 240 volt to 208 volt operation
Disconnect unit from power supply source.
Open service door (Fig. 8) by loosening fastener at top of the unit over the
control panel using a 5 mm Allen wrench. A rubber grommet must first be removed to access the bolt.
Move transformer primary lead from the 240v tap to the 208v tap (Fig. 10).
Open left side panel and locate relay K3.1 (Fig. 11).
Remove the jumper wire from the appropriate terminal positions. The
terminals on K3.1 relay socket are numbered. Use the chart below to determine from which terminals to disconnect jumpers.
INST ALLATION
Electrical requirements of gas units: Model Voltage Phase Cycle/Hz KW LCG-6 120 1 60 1 LCG-10 120 1 60 1 LCG-1020 208/240 1 60 1.5 LCG-20 208/240 1 60 1.6 LCG-40 208/240 3 60 3.5
Fig. 8
Fig. 10
Fig. 9
240 volt tap
208 volt tap
Common tap
Fig. 11
Jumper
wire
Terminal
location
K3.1 relay
Cable Inlet
N
L
L
L
3
2
1
Once conversion has been completed, a “total reset” of the CPU-PCB must be
done.
Record all end-user (custom) programs before undertaking a Total Reset.
Secure all panels and covers.
Total reset
Turn on unit.
Press and hold IQT Sensor key, IQT key, and PROG/START
simultaneously and turn unit off.
Release all keys. Wait at least 4 seconds and turn unit on.
NOTE: With total reset procedure all custom programs are deleted. After a total reset, 12:00 or 13:00 will be indicated on the timer display. Real time must be reset. To set clock to actual time, see page 50.
Humidity calibration
The interior cabinet must be clean. If it is not, wipe clean.
The interior cabinet temperature must be below 122°F (50°C) and the
cabinet must be dry.
Turn on unit.
Open cabinet door.
Select any cooking mode.
Access diagnostic program by pressing TEMPERATURE key, IQT
Sensor key, and IQT key simultaneously until the word VERSION appears next to the IQTkey.
Use Central Dial to select CALIBRATE.
Close cabinet door.
To star t calibration press PROG/START and TEMPERATURE key
simultaneously.
Calibration starts automatically and lasts 45-60 minutes.
After calibration, unit must be switched off for 5 seconds before using again.
During calibration, several values will be shown on the display.
Once calibration begins, do not interrupt the process.
Do not open door until calibration is complete.
After calibration, very hot steam–around 392°F (200°C)–remains in the cabinet. When opening the cabinet door hot steam will escape, and burns could result.
62
Model Terminal Positions LCG-6 5 and 6 LCG-10 5 and 6 LCG-1020 5 and 6 LCG-20 6 and 7 LCG-40 5 and 6
63
Fig. 12
Fig. 13
Fig. 14
WA
WA
WZ
INST ALLATION
Water supply
9) Drain Connection (WA)
For drain connection (Fig. 12) use only steam temperature resistant pipe,
diameter 2 in. (50 mm) and constant slope 5%. No hose should be used.
Direct drain connection is possible, ventilated gap is an integrated part of the
appliance (Fig. 13).
Drain pipe should be supported to the wall/floor.
Max. water discharge rate during Auto Flush:11 gal./min. (0.7 liter/sec.)
Average drain water temperature: 150°F (65°C).
10) Water Connection (WZ)
Observe all local plumbing codes.
Flush water line before connecting the water supply to the unit.
Connect to cold, potable water only.
Operational water pressure: MIN: 30 psi (200kPa) MAX: 88 psi (600kPa).
RECOMMENDED: 44 psi (300kPa). Water flow must be at least 3 gal/min (12 l/min).
Water connection supplied by customer: 1⁄
2 in. pressure hose with R
3
4 in. tapered
fitting.
Customer fitted shut-off valve for each appliance.
Water conductivity: 50-2000 µS, lower conductivity on request.
Maximum chloride concentration (Cl-): below 150 ppm (150 mgr/liter)
at any time.
For conductivity above 2000 µS or higher chloride concentration use
hydrogen-ion exchanger (A in Fig. 15) in the supply water line.
Water Redox-Potential must be below 300mV at any time.
For higher Redox Potential use Active Carbon Filter (B in Fig. 14). Obser ve
maintenance period of active carbon filter.
Use a 3 micron (0.08mm) particle filter (C in Fig. 14) to prevent excessive
soiling of the supply water.
Recommended test instruments: Cl2 Tester (swimming pool accessories),
conductivity tester, redox meter.
Optional Treated Water Connection
To connect a dual water supply–treated soft water or warm water below
140°F (60°C)–disconnect T-water connection at the two water inlets (Fig. 15).
Connect treated water to water inlet marked WZ2 and standard water to inlet marked WZ1. Treated water must comply with the above-mentioned water specifications.
NOTE: If using external filter to treat hard water: Contact your Henny Penny distributor for average water consumption when using CleanJet. Increases in average water consumption may exceed specifications of external filters and may affect the frequency of filter maintenance. (See page 57)
Fig. 15
WZ1
WZ2
CBA
64
General
11) Technical Data
Working place specific noise level: <70dB Average water consumption during operation:
Model 6: 3.17 gal/hr (0.2 l/min.) Model 10: 6.7 gal/hr (0.42 l/min.) Model 1020: 10.9 gal/hr (.069 l/min.) Model 20: 13.2 gal/hr (0.83 l/min.) Model 40: 15.8 gal/hr (1.0 l/min.)
Heat emission:
INST ALLATION
Model Latent Sensible LCS/G-6 .64 W (2.30 kJ)/hr 84 W (2.93 kJ)/hr LCS-G-10 1.05 W (8.50 kJ)/hr 1.4 W (5.00 kJ)/hr LCS/G-1020 1.67 W (6.00 kJ)/hr 2.4 W (8.50 kJ)/hr LCS-G-20 2.13 W (7.67 kJ)/hr 2.67 W (9.60 kJ)/hr LCS/G-40 3.7 W (13.35 kJ)/hr 4.26 W (15.34 kJ)/hr
Ventilation
Contact your local regulatory agency for ventilation requirements. If a ventilation hood is installed, observe the following:
The standards of the local authority.
The hood should protrude 12-20 in. (300-500 mm) over the front of the
appliance.
The integrated grease filter should be in the protruding part of the hood.
Specifications and technical descriptions in this applications manual are subject to change without prior notice.
Gas supply
12) Gas supply (for LCG units only)
The ClimaPlus gas model is available for either natural or propane gas. Check the data plate on the left corner of the unit to determine the proper gas supply requirement.
Model Gas Line Connection LCG-6
3
4 in.
1
2 in.
LCG-10
3
4 in.
3
4 in.
LCG-1020 1 in.
3
4 in.
LCG-20 1 in.
3
4 in.
LCG-40 1
1
4 in. 1 in.
DO NOT attempt to use any type of gas other than that specified on the data plate. Incorrect gas supply could result in fire or explosion resulting in severe injuries and/or property damage.
To avoid possible serious personal injury, the installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1988 or latest edition. In Canada, CAN/CGA-B 149.1 Natural Gas Installation Code CAN/CGA-B 149.2 Propane Installation Code.
All Henny Penny Combi-Steamers are equipped with two heat exchanger
systems. One is responsible for steam production, the second for dry heat. Each individual heat exchanger is heated with a separate burner assembly.
Separate gas valves for the steam burner and dry heat burner are responsible for
the gas supply to the individual burners. All LCG models have manual shut-off valves that can be accessed from the left without tools. To operate the valves, unscrew the two knurled screws and remove the service cover. Open or close manual valves as desired.
Gas Leak Test
After piping and fittings have been installed, check for gas leaks. A simple
checking method is to turn on the gas and brush all connections with a soap solution. The appearance of bubbles indicates escaping gas. In this event, the piping connection must be redone until no bubbles occur.
Never use a lighted match or open flame to test for gas leaks. Escaping gas could result in fire or explosion resulting in severe injuries and/or property damage.
Gas pressure
The gas pressure should be measured when all other gas appliances in the
kitchen are on high flame. The minimum and maximum incoming line flow pressures should be as follows:
Natural: 7-10 in. water column (18-25 mb) Propane: 12-14 in. water column (30-35 mb)
INST ALLATION
continued
65
66
During pressure testing note the following:
1. The unit and its individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system when test pressures exceed 1⁄2 psig (3.45kPa). Turn OFF main gas shut-off valve or main gas supply line.
2. The unit must be isolated from the gas supply piping system by closing its individual manual shut-off valves during any pressure testing of the gas supply piping system at test pressure equal to or less than 1⁄2 psig (3.45kPa).
3. If incoming pressure is over 14 in. water column (35 mb) a separate regulator must be installed ahead of the manual gas shut-off valve.
To prevent damage to the control valve regulator, the first time the gas valve knob is turned to the ON position, it is very important to turn the knob very slowly.
NOTE
After turning on the gas, the manual shut-off valve must remain open, except during pressure testing as outlined above, or when necessary during service maintenance.
Incoming pressure reading can be taken by installing a gas pressure gauge on
the front of the unit’s main gas valves test port. This should be done with all gas appliances in operation on the same gas supply line. Should the manifold pressure drop below the desired level, consult your local gas utility service.
Gas Hook-up
INST ALLATION
continued
RIGHT
A minimum pull of appliance away from wall is acceptable in order to disconnect hook-up.
WRONG
Maximum pull prior to disconnect will result in kinked ends and reduce hose and connector life.
67
Utilize elbows when necessary to avoid sharp kinks or excessive bending. For ease of movement, install with a lazy” loop. Gas appliance must be disconnected prior to maximum movement. (Minimum movement is permissible to disconnect gas line.
Cable Restraint
Please refer to the illustration at left when installing cable restraint on all moveable gas appliances
Eye-bolt is to be secured to the building using acceptable building practices.
Dry wall construction
Secure eye-bolt to a framing stud. DO NOT attach to dry wall only. Locate eye-bolt at the same height as the gas service approximately 6 in. (150 mm) to either side of service. Cable restraint must be at least 6 in. (150 mm) shorter than flexible gas line.
INST ALLATION
continued
Couplings and hose should be installed in the same plane as shown at left. DO NOT OFFSET COUPLINGS. This results in twisting and undue torsion causing premature failure.
Correct way to install metal hose for vertical traverse. Note single, natural loop. Allowing a sharp bend, shown at right, strains and twists the metal hose to a point of early failure at the coupling.
Maintain the minimum or larger bending diameter between couplings for the longest life. Couplings too close together, as shown at right, create double bends causing work fatigue failure of fittings.
In all installations where self-draining is not necessary, connect metal hose in a vertical loop. DO NOT CONNECT METAL HOSE HORIZONTALLY unless self-draining is necessary. Then use support on lower plane as show at left.
68
Cooking Guides
The following section offers basic guidelines for preparing a wide variety of popular menu items in the Henny Penny ClimaPlus Combi.
Menu items are charted in a format that covers quantities, proper containers, times, temperatures, ClimaPlus Control settings, and whether probe cooking or and/or additional items should be employed. As you gain experience with this equipment, you may wish to adjust these parameters or to add items that better suit the needs of your foodservice operation and the preferences of your customers. For your convenience, a blank chart has been included at the end of the section to assist you in recording data for your individual recipes.
Key to terms and abbreviations
Units of measure–temperature
Temperatures in the charts appear as number values without degree marks or F/C. Unless other wise indicated, temperatures measured in degrees Fahrenheit appear first; the Celsius equivalent follows immediately enclosed by parentheses.
212 (100) = 212°F (100°C)
Units of measure-weight
Weights for quantities of food in the charts often appear as number values without unit measure abbreviations. Unless otherwise indicated, weight values are always represented in pounds and kilograms. The value representing weight or range of weight measured in pounds appears first; the metric equivalent in kilograms follows immediately enclosed by parentheses.
5-7 (2.3-3.2) = 5-7 lbs. (2.3-3.2 kg)
Total Time
As a convenience, cooking times for items with multiple time-cook only steps have been totaled and appear as Total Time. This cannot be done when any step includes probe cooking, preheating or an IQT program.
ALT = Designates an alternate method that can be used in
place of the steps listed.
Ctrl = ClimaPlus is controlled by the IQT program and cannot
be adjusted by the operator.
Containers
Perf = Perforated Pan = Stainless steel steam table pan Sheet, Sht = Sheet pan Alum = Aluminum Enamel, Enam = “Granite” style enamel cooking pan Grid = Grid rack that fits right into the shelf Chicken grid = Special grid for cooking whole birds upright Drip pan = Single pan set on bottom rack to catch drippings
from above
69
Item/Prep notes Container Max yield
Rotisserie Style Chicken Chicken grid 8 birds
Step Mode Time Probe Temp Clima %
2
1
2-3 lb.whole birds. Season.
Time cook–check for internal temp. 185 (85).
Or,use IQT +Profile.
Per load Per load 1 Combi 13
— —
80 60 30
6 16 birds 2 Combi 13 10 24 birds 3 Dry Heat
Temp
350 (177) 360 (183) 370 (188) 13
1020 48 birds 39 20 40 birds 40
2 3 6 5 12 96 birds
ALT IQT +Profile
Total Time
Browning Level: 6 185 (85) Ctrl
Item/Prep notes Container Max yield
Baked Chicken, pieces
1
2 sheet pan 16 pieces,mixed
Step Mode Time Probe Temp Clima %
Eight cut. Season. Time cook–check for internal
temp. 185 (85). Or,use IQT +Profile.
Per load Per load 1 Combi 10
— —
100
60 30
6 96 pieces 2 Combi 10 10 160 pieces 3 Combi
Temp
340 (171) 360 (182) 380 (194) 5
1020 320 pieces 25 20 320 pieces 40
6 10 20 20 40 640 pieces
Total Time
Item/Prep notes Container Max yield
Turkey, whole Grid/drip pan 1 bird
Step Mode Time Probe Temp Clima %
12-18 lb. (5.5-8 kg) bird. Wash,stuff, season, baste. Probe cook or IQT +Profile.
Per load Per load 1 Combi 165 (74)
185 (85)
80 50
6 2 birds 2 Combi 10 3 birds
Temp
280 (138) 340 (171)
1020 6 birds 20 6 birds 40
2 3 6 6 12 12 birds
ALT IQT +Profile Browning Level: 5 185 (85) Ctrl
Item/Prep notes Container Max yield
Turkey Breast, boneless Grid/drip pan 2 per grid
Step Mode Time Probe Temp Clima %
8-10 lb. (3.6-4.5 kg) boneless breast.
Season. With bone-in breasts, increase
final core temp to 185 (85).
Per load Per load 1 Combi 145 (63)
165 (74)
80 50
6 6 breasts 2 Combi 10 10 breasts
Temp
280 (138) 345 (174)
1020 20 breasts 20 20 breasts 40
3 5 10 10 20 40 breasts
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Meat & Poultry
Item/Prep notes Container Max yield
Oven Fried Chicken
1
2 sheet pan 16 pieces,mixed Step Mode Time Probe Temp Clima %
Eight cut. Bread and prepare to oven fried recipe. Grease pan lightly.
Time cook–check for internal temp. 185 (85).
Or,use IQT +Profile.
Per load Per load 1 Combi 15
60 20
6 96 pieces 2 Combi 10 10 160 pieces
Temp
385 (196) 415 (213)
1020 320 pieces 20 320 pieces 40
6 10 20 20 40 640 pieces
25
Total Time
Cooking stages and suggested parameters
70
Item/Prep notes Container Max yield
Steaks, chops Grid 10-12 steaks
Step Mode Time Probe Temp Clima %
Season. Preheat grids to 575 (300).Vary time for thickness and desired doneness.
Pork,add 3-5 min. Serving tip: Plate grid side up.
Per load Per load 1 Dry Heat
—20
6 60-72 2 Dry Heat 7-10 10 100-120
Temp
Preheat 575 (300) 485 (251)
1020 200-240 20 200-240 40
6 10 20 20 40 400-480
Item/Prep notes Container Max yield
Roast Beef Rib Roast (Prime Rib)
Grid/drip pan 1 per grid
Step Mode Time Probe Temp Clima %
10-18 lb. (4.5-8 kg) roast. Season.
Probe cook or IQT +Low-T. For lighter or darker crust,
adjust IQT +Low-T sear temperature accordingly.
Per load Per load 1 Dry Heat 130 (54)
135 (57) rare
145 (63) medium
155 (68) well
60 20
6 30-54 (13.5-24) 2 Dry Hea t 10 50-90 (22.5-40)
Temp
280 (138) 340 (171)
1 Dry Heat 120 (49)
135 (57) rare
145 (63) medium
155 (68) well
60
2 Dry Heat
280 (138) 340 (171)
1020 100-180 (45-80) 20 100-180 (45-80) 40
3 5 10 10 20 200-360 (90-160)
ALT IQT +Low-T Sear:360 (182) 135-155 (57-68) Ctrl
30-48 (14-22) 50-80 (23-36) 100-160 (46-72) 100-160 (46-72)
3 5 10 10 20 200-320 (92-144)
Item/Prep notes Container Max yield
Beef Tenderloin Grid/drip pan 2 per grid
Step Mode Time Probe Temp Clima %
5-8 lb. (2.3-3.6 kg) pieces. Season.
Per load Per load
6 10
Temp
1020 20 40
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Hamburgers
1
2 sheet pan 8 patties per pan Step Mode Time Probe Temp Clima %
4 oz. frozen patties. Season. For fresh patties, use 60%
ClimaPlus setting.
Per load Per load 1 Combi 8-12 40
6 48 patties 10 80 patties
Temp
425 (218)
1020 160 patties 20 160 patties 40
6 10 20 20 40 320 patties
Item/Prep notes Container Max yield
Meatballs
3
4 in. enamel 5-7 lbs. (2.3-3.2 kg)
Step Mode Time Probe Temp Clima %
1-2
1
2 oz. each meatball.
Mix ingredients and form according to recipe.
Per load Per load 1 Dry Heat 10 20
6 30-42 (14-19) 10 50-70 (23-32)
Temp
350 (177)
1020 100-140 (46-64) 20 100-140 (46-64) 40
6 10 20 20 40 200-280 (92-128)
Cooking stages and suggested parameters
Cooking stages and suggested parameters
71
Meat & Poultry continued
Pork
Item/Prep notes Container Max yield
Corned Beef Brisket, raw Grid/drip pan 1 piece per grid
Step Mode Time Probe Temp Clima %
Texture is more important than core temperature.Allow sufficient cook time for brisket to become very tender.
Per load Per load 1 Combi 165-170 (74-77) 100
6 3 briskets 10 5 briskets
Temp
280 (138)
1020 10 briskets 20 10 briskets 40
3 5 10 10 20 20 briskets
48-60 (22-33) 80-120 (36-55) 160-240 (72-110) 160-240 (72-110) 320-480 (144-220)
Item/Prep notes Container Max yield
Beef Stew 2
1
2 in. pan 8-12 lbs. (3.6-5.5 kg)
Step Mode Time Add’l Functions Clima %
Step 1: Brown meat with Dry Heat mode.
Step 2: Mix all ingredients, cover and simmer to taste.
Per load Per load 1 Dr y Heat 5
Half Speed Fan*
30 70
6 2 Combi 1-1.5 hrs. 10
Temp
320-360 (160-182) 280 (138)
1020 20 40
6 10 20 20 40
Cooking stages and suggested parameters
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
Item/Prep notes Container Max yield
Meatloaf 2
1
2 in. pan 8-10 lbs.(3.6-4.5 kg) Step Mode Time Probe Temp Clima %
Mix ingredients and form according to recipe.
Molds can be substituted for pans.
Probe cook or IQT +Profile.
Per load Per load 1 Moist 15
150 (66)
100
40 20
6 24-30 (11-13.5) 2 Combi 10 40-50 (18-22.5) 3 Dr y Heat
Temp
180 (82) 280-320 (138-160) 335 (168) 10
1020 80-100 (36-45) 20 80-100 (36-45) 40
3 5 10 10 20 160-200 (72-90)
ALT IQT +Profile Browning Level: 4 155 (68) Ctrl
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Ribs (pork or beef) Grid 2 slabs
Step Mode Time Probe Temp Clima %
Season or marinate.
Per load Per load 1 Moist 12-15
— —
100
70 30
6 12 slabs 2 Combi 15-20 10 20 slabs 3 Dry Heat
Temp
180 (82) 280 (138) 350 (177) 15
1020 40 slabs 42-50 20 40 slabs 40
6 10 20 20 40 80 slabs
Total Time
Item/Prep notes Container Max yield
Bacon
1
2 sheet pan Approx.:1 (.5)
Step Mode Time Add’l Functions Clima %
Tray up.Approximately 1 lb. (.5 kg) per pan.
Per load Per load 1 Combi 5-7 Half Speed Fan* 40
6 6 (3) 10 10 (5)
Temp
400 (204)
1020 20 (10) 20 20 (10) 40
6 10 20 20 40 40 (20)
Cooking stages and suggested parameters
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
72
Item/Prep notes Container Max yield
Sausage, links or patties
1
2 sheet pan 1.5 (.7) per pan Step Mode Time Probe Temp Clima %
Per load Per load 1 Combi 8-12 30
6 9 (4.2) 10 15 (7)
Temp
325 (163)
1020 30 (14) 20 30 (14) 40
6 10 20 20 40 60 (28)
Item/Prep notes Container Max yield
Smoked Sausage Grid or
1
2 sheet 4 (1.8) per grid
Step Mode Time Probe Temp Clima %
Time cook or probe cook.
Per load Per load 1 Combi 12-15
165 (74)
30
6 24 (11) ALT Combi 10 40 (18)
Temp
325 (163) 325 (163)
1020 80 (39) 20 80 (39) 40
6 10 20 20 40 160 (78)
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Italian Sausage, Bratts Grid or
1
2 sheet 4 (1.8) per grid Step Mode Time Probe Temp Clima %
Per load Per load 1 Moist 7
— —
100
40 20
6 24 (11) 2 Combi 7 10 40 (18) 3 Dr y Heat
Temp
180 (82) 280 (138) 350 (177) 5
1020 80 (39) 19 20 80 (39) 40
6 10 20 20 40 160 (78)
ALT 3 Dry Heat
Total Time
165 (74)
Item/Prep notes Container Max yield
Pork Tenderloin Grid or enamel 8-12 pieces
Step Mode Time Probe Temp Clima %
Season.
Per load Per load 1 Combi 165 (74) 40
6 48-72 10 80-120
Temp
320 (160)
1020 160-240 20 160-240 40
6 10 20 20 40 320-480
24-36 (11-16.5) 40-60 (18-27.5) 80-120 (36-55) 80-120 (36-55) 160-240 (72-110)
Item/Prep notes Container Max yield
Pork Loin Grid/drip pan 1 per grid
Step Mode Time Probe Temp Clima %
8-12 lb. (3.6-5.5 kg) loin roasts. Season.
Per load Per load 1 Moist 10
155 (68) 165 (74)
100
60 35
6 2 Combi 10 3 Combi
Temp
212 (100) 320 (160) 350 (177)
1020 20 40
3 5 10 10 20
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Cooking stages and suggested parameters
73
Fish, Seafood
Item/Prep notes Container Max yield
Pork Roast Fresh Ham, large
Grid/drip pan 2 per grid
Step Mode Time Probe Temp Clima %
8 lbs. (3.6 kg) or more. Season. IQT +Profile
Per load Per load 1 IQT +Profile 165 (74) Ctrl
6 4 roasts 10 6 roasts
Temp
Browning Level:6
1020 12 roasts 20 12 roasts 40
2 3 6 6 12 24 roasts
Pork continued
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Smoked ham Grid/drip pan 1 per grid
Step Mode Time Probe Temp Clima %
12-15 lbs. (5.5-6.8 kg) hams.
Per load Per load 1 Combi 165 (74) 40
6 2 hams 10 3 hams
Temp
250 (121)
1020 6 hams 20 6 hams 40
2 3 6 6 12 12 hams
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Fish, poached Perf pan 8 lbs. (3.6 kg)
Step Mode Time Probe Temp Clima %
Season.
Per load Per load 1 Moist 140 (60) 100
6 48 (21.6) 10 80 (36)
Temp
180 (82)
1020 160 (72) 20 160 (72) 40
6 10 20 20 40 320 (144)
Item/Prep notes Container Max yield
Fish, baked
1
2 sheet pan 5 lbs. (2.3 kg) Step Mode Time Probe Temp Clima %
Lightly grease pan. Season and top.
Per load Per load 1 Combi 8-12 60
6 30 (14) 10 50 (23)
Temp
345 (174)
1020 100 (46) 20 100 (46) 40
6 10 20 20 40 200 (92)
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Fish steaks, grilled Grid 8-12 steaks
Step Mode Time Probe Temp Clima %
1
1
2 - 21⁄2 in. (38-63 mm) steaks. Season. Preheat grid to 575 (300).
Per load Per load 1 Combi
90 40
6 24-36 steaks 2 Combi 6-8 10 40-60 steaks
Temp
Preheat 575 (300) 485 (252)
1020 80-120 steaks 20 80-120 steaks 40
3 5 10 10 20 160-240 steaks
Cooking stages and suggested parameters
74
Item/Prep notes Container Max yield
Breaded Fish Pieces
3
4 in. enamel 21⁄2 lbs.(1.1 kg) Step Mode Time Probe Temp Clima %
Lightly grease pan. Spray top of product with
shortening prior to cooking.
Per load Per load 1 Combi 6-8 30
6 15 (6.6) 10 25 (11)
Temp
425 (218)
1020 50 (23) 20 50 (23) 40
6 10 20 20 40 100 (45)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Cocktail Shrimp Perf pan 5 lbs. (2.3 kg)
Step Mode Time Probe Temp Clima %
Season. Cook in shell. Remove and blast-chill
immediately.
Per load Per load 1 Moist 6-10 100
6 30 (13.8) 10 50 (23)
Temp
180 (82)
1020 100 (46) 20 100 (46) 40
6 10 20 20 40 200 (92)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Whole Lobster,steamed Perf pan 3-4 lobsters
Step Mode Time Probe Temp Clima %
Per load Per load 1 Moist 10-14 100
6 9-12 10 15-20
Temp
212 (100)
1020 30-40 20 30-40 40
3 5 10 10 20 60-120
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Clams, Mussels Perf pan 3 lbs. (1.4 kg)
Step Mode Time Probe Temp Clima %
Cook in shell. Ladle butter, sauce over after cooking.
Per load Per load 1 Moist 8-10 100
6 9 (4.2) 10 15 (7)
Temp
212 (100)
1020 30 (14) 20 30 (14) 40
3 5 10 10 20 60 (28)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Scallops, broiled Enamel 3 lbs. (1.4 kg)
Step Mode Time Probe Temp Clima %
Drain and clean.Dredge in flour.Season. Lightly oil pan and preheat to 425 (218). Stir into pans when loading.
Per load Per load 1 Combi 4-8 30
6 9 (4.2) 10 15 (7)
Temp
385 (196)
1020 30 (14) 20 30 (14) 40
3 5 10 10 20 60 (28)
Cooking stages and suggested parameters
75
Meats, Special Cuts
Item/Prep notes Container Max yield
Cutlets, breaded
3
4 in. enamel 12-15 pieces Step Mode Time Probe Temp Clima %
Bread. Preheat pans to 575 (300).
Spray top of product with shortening prior to cooking.
Per load Per load 1 Combi
90 30
6 72-90 2 Combi 6-8 10 120-150
Temp
Preheat 575 (300) 425 (218)
1020 240-300 20 240-300 40
6 10 20 20 40 480-600
Item/Prep notes Container Max yield
Medallions
3
4 in. enamel 12-15 pieces
Step Mode Time Probe Temp Clima %
Season or marinate. Preheat pan to 575 (300).
Per load Per load 1 Combi
90 20
6 72-90 2 Combi 6-8 10 120-150
Temp
Preheat 575 (300) 485 (252)
1020 240-300 20 240-300 40
6 10 20 20 40 480-600
Item/Prep notes Container Max yield
Scaloppini
3
4 in. enamel 12-15 Step Mode Time Probe Temp Clima %
Dredge in seasoned flour. Mist with oil. Oil pan lightly and preheat to 575 (300).
Serving tip: Plate pan side up.
Per load Per load 1 Combi
90 30
6 72-90 2 Combi 5-7 10 120-150
Temp
Preheat 575 (300) 485 (252)
1020 240-300 20 240-300 40
6 10 20 20 40 480-600
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Baked Potatoes
1
2 sheet or grid 20 pota toes Step Mode Time Probe Temp Clima %
80 ct. Wash,oil lightly or season.
Per load Per load 1 Combi
90 40
6 120 potatoes 2 Combi 45 10 200 potatoes
Temp
Preheat 525 (270) 385 (196)
1020 400 potatoes 20 400 potatoes 40
6 10 20 20 40 800 potatoes
Cooking stages and suggested parameters
Potatoes
Item/Prep notes Container Max yield
Steamed Potatoes 2
1
2
in.perf pan 6 lbs. (2.7 kg)
Step Mode Time Probe Temp Clima %
Wash and cut.Preheat.
Per load Per load 1 Combi
90
100
6 36 (16) 2 Moist 30-35 10 60 (27)
Temp
Preheat 280 (138) 230 (110)
1020 120 (54) 20 120 (54) 40
6 10 20 20 40 240 (108)
Cooking stages and suggested parameters
76
Item/Prep notes Container Max yield
Roasted Potatoes
1
2 sht or enam 6 lbs. (2.7 kg) Step Mode Time Probe Temp Clima %
Cut, oil, season.
Per load Per load 1 Combi
90 20
6 36 (16) 2 Combi 20 10 60 (27)
Temp
Preheat 525 (270) 425 (218)
1020 120 (54) 20 120 (54) 40
6 10 20 20 40 240 (108)
Cooking stages and suggested parameters
Breads
Item/Prep notes Container Max yield
Proofing
1
2 sheet pan 2 lbs. (.9 kg) Step Mode Time Probe Temp Clima %
Lightly grease pan. Proof until dough doubles in
size.
Per load Per load 1 Moist see note 100
6 6 (2.7) 10 10 (4.5)
Temp
95 (35)
1020 20 (9) 20 20 (9) 40
3 5 10 10 20 40 (18)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Bread Dough
1
2 sheet pan 2 lbs. (.9 kg) Step Mode Time Probe Temp Clima %
Proof first. Lightly grease pan.
Per load Per load 1 Dry Heat 15-20 70
6 6 (2.7) 10 10 (4.5)
Temp
350 (177)
1020 20 (9) 20 20 (9) 40
3 5 10 10 20 40 (18)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Rolls
1
2 sheet pan 12-15 rolls Step Mode Time Add’l Function Clima %
4 oz. rolls. Proof first. Lightly grease pan. Egg wash
rolls.
Per load Per load 1 Dry Heat 15-17 Steam Injection 100
6 36-45 rolls 10 60-75 rolls
Temp
335 (168)
1020 120-150 rolls 20 120-150 rolls 40
3 5 10 10 20 240-300 rolls
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Muffins
1
2 sheet pan 1 dozen per pan
Step Mode Time Add’l Function Clima %
4 oz. muffins. Lightly grease pan.
Per load Per load 1 Dry Heat 5 Half Speed Fan*
80 30
6 3 dozen 2 Dry Heat 12-15 10 5 dozen
Temp
335 (168) 335 (168)
1020 10 dozen 20 10 dozen 40
3 5 10 10 20 20 dozen
17-20
Total Time
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
Note: Proof until dough doubles in size.
77
Breads continued
Item/Prep notes Container Max yield
Cinnamon Rolls
1
2 sheet pan 2 lbs.(.9 kg) Step Mode Time Add’l Function Clima %
Proof first. Lightly grease pan.
Per load Per load 1 Dry Heat 5 Half Speed Fan*
80 30
6 6 (2.7) 2 Dry Hea t 10-13 10 10 (4.5)
Temp
335 (168) 335 (168)
1020 20 (9) 20 20 (9) 40
3 5 10 10 20 40 (18)
15-18
Total Time
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
Item/Prep notes Container Max yield
Biscuits, frozen
1
2 sheet pan 2 dozen per pan
Step Mode Time Probe Temp Clima %
Lightly grease pan. Serving tip: Melted butter
may be brushed on biscuit tops after cooking.
Per load Per load 1
2
Preheat Dry Heat
—20
6 6 dozen
3 Dry Heat 1510 10 dozen
Temp
7— 80335 (168)
335 (168)
1020 20 dozen 20 20 dozen 40
3 5 10 10 20 40 dozen
22
Total Time
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Sheet Cake Brownies
1
2 sheet pan 54 2in.squares Step Mode Time Add’l Function Clima %
Lightly grease pan.
Per load Per load 1 Dry Heat 15 Half Speed Fan*
10 10
6 324 pieces 2 Dry Hea t 20 10 540 pieces
Temp
350 (177) 340 (171)
1020 1080 pieces 20 1080 pieces 40
6 10 20 20 40 2160 pieces
35
Total Time
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
Item/Prep notes Container Max yield
Cookies
1
2 sheet pan 1 dozen per pan Step Mode Time Add’l Function Clima %
2 oz. cookies. Lightly grease pan.
Per load Per load 1 Dry Heat 3 Half Speed Fan*
20 20
6 6 dozen 2 Dry Heat 3-6 10 10 dozen
Temp
335 (168) 335 (168)
1020 20 dozen 20 20 dozen 40
6 10 20 20 40 40 dozen
6-9
Total Time
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
Item/Prep notes Container Max yield
Strudel Perf alum 2 per pan
Step Mode Time Probe Temp Clima %
Brush with egg wash.
Per load Per load 1 Combi 45-55 60
6 6 10 10
Temp
335 (168)
1020 20 20 20 40
3 5 10 10 20 40
Cooking stages and suggested parameters
78
Item/Prep notes Container Max yield
Cobbler 2
1
2 in. pan 12 lbs. (5.5 kg) Step Mode Time Probe Temp Clima %
According to recipe.
Per load Per load 1 Combi 20
70 25
6 72 (33) 2 Dry Heat 40 10 120 (55)
Temp
365 (185) 345 (174)
1020 240 (110) 20 240 (110) 40
6 10 20 20 40 480 (220)
60
Total Time
80Total Time
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Pie, fresh
1
2 sheet pan 2-3 pies per pan
Step Mode Time Probe Temp Clima %
Brush tops with egg wash.
Per load Per load 1 Dry Heat 35-45 30
6 6-9 pies 10 10-15 pies
Temp
335 (168)
1020 20-35 pies 20 20-35 pies 40
3 5 10 10 20 40-60 pies
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Bread Pudding 2
1
2 in. pan 12 lbs.(5.5 kg) Step Mode Time Probe Temp Clima %
According to recipe. Lightly grease pans.
Per load Per load 1 Combi 40
— —
80 50 20
6 36 (16.5) 2 Combi 30 10 60 (27.5) 3 Dry Heat
Temp
280-300 (138-149) 320-340 (160-171)
350 (177) 10
1020 120 (55) 20 120 (55) 40
3 5 10 10 20 240 (110)
Cooking stages and suggested parameters
Miscellaneous
Item/Prep notes Container Max yield
Entrees, frozen 2
1
2 in. pan 12 lbs.(5.5 kg) Step Mode Time Probe Temp Clima %
Brush with egg wash.
Per load Per load 1 Combi 45-60 60
6 72 (33) 10 120 (55)
Temp
280-320 (138-160)
1020 240 (110) 20 240 (110) 40
6 10 20 20 40 480 (220)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Entrees, fresh 2
1
2 in. pan 12 lbs. (5.5 kg)
Step Mode Time Probe Temp Clima %
Use also for thawed entrees.
Per load Per load 1 Combi 165 (74) 40
6 72 (33) 10 120 (55)
Temp
280 (138)
1020 240 (110) 20 240 (110) 40
6 10 20 20 40 480 (220)
Cooking stages and suggested parameters
79
Miscellaneous continued
Item/Prep notes Container Max yield
Vegetables, frozen 2
1
2 in. perf. pan 9 lbs.(4 kg) Step Mode Time Probe Temp Clima %
Per load Per load 1 Moist 8-15 100
6 54 (24) 10 90 (40)
Temp
212-225 (100-107)
1020 180 (80) 20 180 (80) 40
6 10 20 20 40 360 (160)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Vegetables, fresh 2
1
2 in. perf. pan 6 lbs. (2.7 kg)
Step Mode Time Probe Temp Clima %
Cut to desired serving size.
Per load Per load 1 Moist 6-10 100
6 36 (16) 10 60 (27)
Temp
212 (100)
1020 120 (54) 20 120 (54) 40
6 10 20 20 40 240 (108)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Beans, dry 2
1
2 in. pan 6 lbs. (2.7 kg) dry Step Mode Time Probe Temp Clima %
Rinse and soak beans. Stir every 10 to 15 minutes
during step 2. Per load yield is indicated in
dry wt./cooked wt.
Per load Per loaddry/cooked 1 Moist 30
100
40
6 36/90 (16/41) 2 Combi 40-60 10 60/150 (27/68)
Temp
265 (129) 280 (138)
1020 120/300 (54/136) 20 120/300 (54/136) 40
6 10 20 20 40 240/600 (108/272)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Rice 2
1
2 in. pan 3 lbs. (1.4 kg) dry Step Mode Time Probe Temp Clima %
Add liquid to rice and let stand for a minimum of 20 minutes before cooking.
Converted rice will cook quicker. Per load yield is indicated in
dry wt./cooked wt.
Per load Per loaddry/cooked 1 Combi 20-40 100
6 18/42 (8.2/19) 10 30/70 (14/32)
Temp
260 (127)
1020 60/140 (28/64) 20 60/140 (28/64) 40
6 10 20 20 40 120/280 (56/128)
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Pasta 4 in. pan 6 lbs. (2.7 kg) dry
Step Mode Time Probe Temp Clima %
Add water to pan covering pasta completely.Stir pasta thoroughly after Step 1. When done, remove from unit and drain immediately.
Per load yield is indicated in dry wt./cooked wt.
Per load Per loaddry/cooked 1 Moist 8
100 100
6 18/54 (8/24) 2 Moist 8-15 10 30/90 (13.5/40.5)
Temp
212 (100) 212 (100)
1020 60/180 (27/81) 20 60/180 (27/81) 40
3 5 10 10 20 120/360 (54/162)
Cooking stages and suggested parameters
80
Item/Prep notes Container Max yield
Egg Rolls, frozen
1
2 sheet pan 24 per pan Step Mode Time Probe Temp Clima %
3-4 oz. egg rolls.
Per load Per load 1 Combi 8-12 40
6 144 egg rolls 10 240 egg rolls
Temp
480 (250)
1020 480 egg rolls 20 480 egg rolls 40
6 10 20 20 40 960 egg rolls
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Pizza, frozen Perf alum 1 pie per pan
Step Mode Time Add’l Function Clima %
Maximum diameter pizza for half sheet pan is 12 in.
Models 1020 and 40 can accommodate larger pizzas on full size sheet pans
Per load Per load 1 Combi 3-5 Half Speed Fan* 20
10
6 6 pies 2 Dry Heat 8-10 10 10 pies
Temp
340 (171) 365 (185)
1020 20 pies 20 20 pies 40
6 10 20 20 40 40 pies
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
Item/Prep notes Container Max yield
Eggs, hard cooked Grid 5 dozen per grid
Step Mode Time Probe Temp Clima %
Set layer pack directly on combi grids.
For loose eggs,use perf pan.
Per load Per load 1 Moist 14-18 100
6 30 dozen 10 50 dozen
Temp
212 (100)
1020 100 dozen 20 100 dozen 40
6 10 20 20 40 200 dozen
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Egg Casserole 2
1
2 in. pan 5-7 lbs. (2.3-3.2 kg) Step Mode Time Probe Temp Clima %
Mix ingredients according to recipe.
Lightly grease pan.
Per load Per load 1 Combi 10
100
40
6 15-21 (7-9.5) 2 Combi 7-10 10 25-35 (11.5-16)
Temp
280 (138) 320 (160)
1020 50-70 (23-32) 20 50-70 (23-32) 40
6 10 20 20 40 100-140 (46-64)
17-20
Total Time
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Quiche
1
2 sheet pan 2-3 per pan
Step Mode Time Add’l Function Clima %
Mix ingredients according to recipe. Place mixture in pie shells. Pie shells may require par-baking.
Per load Per load 1 Combi 20 Half Speed Fan* 100
40
6 12-18 2 Combi 25 10 20-30
Temp
350 (177) 365 (185)
1020 40-60 20 40-60 40
6 10 20 20 40 80-120
45
Total Time
Cooking stages and suggested parameters
* If unavailable, use Pulse Fan.
81
Item/Prep notes Container Max yield
Stir Fry 2
1
2 in. enam 8 lbs.(3.6 kg) Step Mode Time Probe Temp Clima %
Prepare ingredients according to recipe.
Preheat pans to 575 (300). Sauce after removing food
from unit.
Per load Per loaddry /cooked 1 Combi
90 80
6 48 (21.6) 2 Combi 8-10 10 80 (36)
Temp
Preheat 575 (300) 425 (218)
1020 160 (72) 20 160 (72) 40
6 10 20 20 40 320 (144)
Cooking stages and suggested parameters
Miscellaneous continued
82
Item/Prep notes Container Max yield
Step Mode Time Probe Temp Clima % Per load Per load 1
6 2 10 3
Temp
1020 20 40
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Step Mode Time Probe Temp Clima % Per load Per load 1
6 2 10 3
Temp
1020 20 40
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Step Mode Time Probe Temp Clima % Per load Per load 1
6 2 10 3
Temp
1020 20 40
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Step Mode Time Probe Temp Clima % Per load Per load 1
6 2 10 3
Temp
1020 20 40
Cooking stages and suggested parameters
Item/Prep notes Container Max yield
Step Mode Time Probe Temp Clima % Per load Per load 1
6 2 10 3
Temp
1020 20 40
Cooking stages and suggested parameters