SECTION 3. OPERATION
3-1. INTRODUCTION This section provides explanations of all controls, along
with operating procedures and daily maintenance. Read the Introduction, Installation and Opeation Sections before operating the unit.
Wait at least 4 hours before plugging the unit into an electrical supply. The gases and oils in the refrigeration system needs to settle before operating the compressor, or damage to the compressor could result.
3-2. OPERATING CONTROLS Refer to figure 3-1.
Fig. Item Description Function No. No.
3-1 1 Power Switch Turns electrical power off and on to the unit; located on the
bottom of the control panel
3-1 2 Digital Display Shows the temperatures and the information in the Technical
Mode
3-1 3 Used to increase setpoint values, as well as programming
values; also, automatic defrost cycles are programmed in the controls, but to manually start a defrost cycle, press and hold for 3 seconds to start a manual defrost cycle;
“DEF/SET’ shows in display
3-1 4 Used to decrease setpoint values, as well as programming
values
3-1 5 Press to view the setpoint temperature, or hold it for it for 4
seconds to enter the program mode; once in the Program Mode, press to view other parameter setpoints;
Press , along with and to change the parameters
3-1 303
Henny Penny Model CMC/CMR-103,104,105,106,107
3-2. OPERATING CONTROLS (Continued)
3 2 1
Figure 3-1
4 5
303 3-2
Henny Penny Model CMC/CMR-103,104,105,106,107
3-3. BASIC OPERATION 1. Turn power switch to ON position.
2. Wait for temperature to reach operating temperature, 34 to 38° F (1.1 to 3.3° C).
3. Place chilled product into case.
Do not block the air return and air discharge vents with product. Product temperatures may become unsafe, and increase operating costs.
Do not use mechanical devices or other means to quicken the defrosting process, other than those recommended by the manufacturer, or damage to the unit could result.
Do not use electrical appliances inside the food storage areas of the unit, unless they are of the type recommended by the manufacturer, or damage to the unit could result.
3-4. CLEANING Weekly:
1. Remove all electrical power supplied to the unit by unplug­ging the power cord from the wall, or by turning off the wall circuit breaker.
2. Clean interior and exterior surfaces with a soft cloth, soap and water.
Do not use steel wool, other abrasive cleaners or cleaners/sanitizers containing chlorine, bromine, iodine or ammonia chemicals, as these will deteriorate the stainless steel, and glass material, and shorten the life of the unit.
Do not use a water jet (pressure sprayer) to clean the unit, or component failure could result.
3. Clean around the electronic controls with a soft, damp cloth.
4. Reconnect the electrical power, and unit is now ready for operation.