Henny Penny 341 User Manual

Model OFE/OFG/OEA/OGA-341, 342
SECTION 5. TROUBLESHOOTING
5-1. TROUBLE SHOOTING GUIDE
Problem Cause Correction
POWER switch ON but fryer • Open circuit Plug fryer in completely inoperative
Check breaker or fuse at supply box
Shortening will not Open high limit Reset high limit per heat but lights are on. circuit High Limit Temperature Error message “E10” Control Section
• Drain valve open • Turn drain valve handle to Error message “E15” closed position
Foaming or boiling Water in shortening At end of Cook Cycle, drain over of shortening shortening and clean
• Improper or bad • Use recommended shortening shortening
• Improper filtering • Refer to the procedure covering filtering the shortening
• Improper rinsing after • Clean and rinse the frypot, then cleaning the fryer dry thoroughly
Shortening will not Drain valve clogged Open valve, force cleaning drain from frypot with crumbs brush through drain
Filter switch on, Motor thermal Reset thermal switch per section motor does not run protector tripped on Filter Pump Motor Protector – Manual Reset
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com, or 1-800-417-8405 or 1-937-456-8405.
903 5-1
Model OFE/OFG/OEA/OGA-341, 342
5-2. ERROR CODES In the event of a control system failure, the digital display will show an "Error Message." These messages are coded: “E4”, “E5”, “E6”, “E10”, “E15”, “E20”, “E-31”, “E41”, “E46”, “E54”, E-70-A & B and “E92”. A constant tone is heard when an error code is displayed, and to silence this tone, press any button.
DISPLAY CAUSE PANEL BOARD CORRECTION
“E-4” Control board Turn switch to OFF position, then turn switch back to ON. overheating if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5” Shortening Turn switch to OFF position, then turn switch back to ON; overheating if display shows “E-5”, the heating circuits and temperature probe should be checked
“E-6 A” Temperature Turn switch to OFF position, then turn switch back to ON;
probe open if display shows “E-6”, check the temperature probe; to replace, refer to Technical Manual
“E-6 B” Temperature Turn switch to OFF position, then turn switch back to ON;
probe shorted if display shows “E-6” check the temperature probe; to replace, refer to Technical Manual
“E-10” High limit Reset the high limit by manually pushing up on the reset button; if high limit does not reset, high limit must be replaced; refer to Technical Manual
“E-15” Drain switch Close drain, using the drain valve handle; if display still failure shows “E-15”, check the drain microswitch; refer to Technical Manual
“E-41”, Programming Turn switch to OFF, then back to ON; if display shows any
“E-46” failure of the error codes, try to reinitialize the control (Special Program Section) if error code persists, replace the control board; refer to Technical Manual
5-2 808