Heat Wagon HVF110, HVF210, HVF310, HVF410HD User Manual

C US
Valparaiso, IN 46383
219-464-8818 • Fax 219-462-7985
www.heatwagon.com
Installation and Maintenance Manual
Please retain this manual for future reference.
HVF110, 210, 310, 410HD
Construction Heaters
HVF110 for SN 21103001 and beyond
HVF210 for SN 21202501 and beyond
HVF310 for SN 21302501 and beyond
HVF410HD for SN 21801001 and beyond
For your safety: Do not use this heater in
a space where gasoline or other liquids
having flammable vapors are stored.
Revision 5-15
CONSTRUCTION HEATER GENERAL HAZARD WARNING
TECHNICIAN.
WARNING
WARNING
WARNING
We cannot anticipate every use which may be made for our heaters. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULA­TIONS.
Other standards govern the use of fuel gases and heat producing products in specific applica­tions. Your local authority can advise you about these.
FOR YOUR SAFETY
DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS HAVING FLAMMABLE VAPORS ARE STORED OR USED.
IMPORTANT
Heater is designed for use as a construction heater. Heater is not intended for use in pest remediation. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration, or repair and to provide emergency heat. Properly used, the heater provides safe, economical heating. Products of combustion are vented out­side the area being heated.
Installation and Maintenance Manual
Model HVF110, 210, 310, 410HD
Construction Heater
Table of Contents:
Safety and Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5, 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7, 11-17
HVF110 Wiring/Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-20
HVF210 Wiring/Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21-23
HVF310 Wiring/Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21, 24-25
HVF410HD Wiring/Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-28
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Chimney/Flue Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
WARRANTY
All new Heat Wagon and Sure Flame heaters and fans are guaranteed against defective materials and work­manship for one (1) year from invoice date.
Warranty repairs may be made only by an authorized, trained and certified Heat Wagon dealer. Warranty repairs by other entities will not be considered. Warranty claims must include model number and serial number.
LIMITATIONS
Warrant claims for service parts (wear parts) such as spark plugs, igniters, flame rods will not be allowed. Diagnostic parts such as voltage meters and pressure gauges are not warrantable.
Evidence of improper fuel usage, fuel pressures outside of manufacturer’s specification, poor fuel quality, and improper electric power, misapplication or evidence of abuse may be cause for rejection of warranty claims.
Travel time, mileage and shipping charges will not be allowed. Minor adjustments of heaters are dealers’ responsibility. Defective parts must be tagged and held for possible return to the factory for 60 days from date of repair. The factory will provide a return goods authorization, (RGA) for defective parts to be returned.
No warranty will be allowed for parts not purchased from Heat Wagon.
342 N. Co. Rd. 400 East • Valparaiso, IN 46383
219-464-8818 • 888-432-8924 • Fax 800-255-7985
www.heatwagon.com
HVF110 HVF210 HVF310 HVF410HD
1020
94.8
5.73
4.05
0.55-80º W
0.5
0.118
5.9
0.05
89.5
183.5
1.48
10.47
7.65
A=3.5, .196
5.9
0.05
294
2,531
88.0
258.7
2.17
15.37
1,330
11.80
174
A=4, .236
5.9
0.05
412/272
3250
354/231
2.89/1.86
1,820
20
2.0-80º W
160/218
0.6
1.5
5.90
0.05
17.2
49.3x20x33.3
142
27.7
56.5x21.9x38
220
Runs on: #2 diesel (winter blend)
#1 kerosene
35.7
56.5x21.9x38
297
57
83x33x48
456
4
HVF 110, 210, 310
5
HVF 110, 210, 310
A
B
Reset Button Room Thermostat Plug
Control Lamp Power Cord
Main Switch A-No Thermostat
B-With Thermostat
Regulation of Electrodes
6
HVF110
HVF210
HVF310
HVF410HD
Note: 1/16” = 1.6 mm
TroubeshooTing
For additional details see advanced troubleshooting (page 11).
7
HVF 410HD
A
B
8
A-No Thermostat B-With Thermostat
HVF 410HD
9
HVF 410HD
10
Loading...
+ 22 hidden pages