The Heath®/Zenith Motion Sensor Entryway Light turns
on up to 60 watts of incandescent light when motion
is detected and then, after a selectable time period,
automatically turns the light off. The built-in photocell
keeps the light off during daylight hours.
OPERATION
Mode:On-TimeWorks:Day Night
Test
Auto
Manual
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
5 Secondsxx
1, 5, or 10 Minx
Until Dawn*x
* resets to Auto Mode at dawn.
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
This package includes:
Sensor
2 Screws
globe
(SL-5615)
Entryway Light
Mounting Nut and Stem
or
jar
(SL-5610)
2 Wire
Connectors
Mounting Strap and
Grounding Wire
Requirements
• The Entryway Light requires 120-volts AC.
• If you want to use Manual Override, the light must be
wired through a switch.
Some codes require installation by a qualified
•
electrician.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
INSTALLATION
For best performance, mount the fixture about 7ft (2.1
m) above the ground.
❒ Turn the power to the lighting circuit off at the
fuse or circuit breaker box.
❒ Remove the existing light fixture.
❒ Install the mounting strap
into the junction box. Orientation of the strap may
be different.
❒ Strip about 5/8 in. (15 mm)
insulation off of the existing
junction box wiring.
❒ Connect the white (neutral) junction box wire to the
white Entryway Light wire. Twist the wires together
and secure with a wire connector.
❒ Caulk the back edge of the light and mounting
surface with silicone weather sealant.
❒ Install a 60 Watt maximum light bulb into the lamp
holder. Do not overtighten. Higher wattages will
void warranty.
Holding Screw
for Globe or Jar
❒ Loosen the front holding screw so the globe or jar
cover can be installed. Secure by tightening the
screw. Do not overtighten.
❒ Connect the green or
bare (ground) mounting
strap wire to a grounded
wire or to a grounded
metal box.
❒ Install the mounting stem into the strap so
that it extends out about 3/4 in. (19 mm).
❒ Install the fixture over
the mounting stem.
❒ Connect the black
(hot) junction box
wire to the black En-
tryway Light wire.
❒ Install and tighten the
mounting stem nut.
2
595-5498-09
TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
The detector is less sensitive to motion directly towards
it and more sensitive to across motion.
NOTE: Sensor has a 1 1/2 minute calibration period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
❒ For aiming, turn the SENSITIVITY (SENS) control
to the mid position and the ON-TIME control to the
TEST position.
ON-TIMESENS
TEST 1 5 10MIN MAX
Bottom of Sensor
In the test position shown above, the light will turn
on for 5 seconds each time motion is detected during both daylight and darkness.
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating vents or air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
110°
7ft
(2.1 m)
30 ft (9.1m)
Maximum Range Maximum
Coverage Angle
Motion
Sensor
Motion
Least Sensitive Most Sensitive
❒ Rotate the sensor base left
and right to aim the sensor.
Adjust the sensor eye up
and down to obtain desired
coverage range.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.
❒ Set SENSITIVITY as needed.
Too much sensitivity may
increase false triggering.
❒
Set the amount of TIME the
lights stay on after motion is detected (1, 5, or 10 minutes).
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 30 ft (9.1 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . . Up to 110°
Electrical Load . . . . . . . . Up to 60 Watt Maximum In-
candescent
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
OVERRIDE
Time Delay . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
595-5498-09
3
TROUBLESHOOTING GUIDE
SYMPTOM
Light will not come
on.
Lig ht comes o n
in daylight.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light bulb is loose or burned
out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turnoff is in effect
check after dark).
5. Incorrect circuit wiring, if this is a
new installation.
6. Re-aim the sensor to cover de
sired area.
1. Entryway Light may be installed
in a relatively dark location.
2. Entryway Light is in Test. (Set
control switch to an ON-TIME
position).
(re-
SYMPTOM
Light comes on
for no apparent
reason.
Light stays on
continuously.
-
Light flashes
on and off.
POSSIBLE CAUSE
1. Entryway Light may be sensing small
animals or automobile traffic (re-aim sensor).
2. Sensitivity is set too high. (Reduce sensitivity).
1. Entryway Light is pointed toward a
heat source like an air vent, dryer
vent, or brightly-painted heat-reflective
surface. (Reposition sensor).
2. Light control is in Manual Mode. (Switch
to Auto.)
1. Heat being reflected from other objects
may be affecting the sensor. (Reposi-
tion sensor).
2. Entryway Light is in the Test mode and
warming up. (Flashing is normal under
these conditions).
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com.
If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST
(M-F). You may also write* to:
HeathCo LLC
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province
FIVE YEAR LIMITED WARRANTY
to province.
For a period of five years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will
void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use,
unauthorized service, or return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer
uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY,
REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE
PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT
LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please
keep your dated sales receipt, it is required for all warranty requests.
4
595-5498-09
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.