Heath Zenith SL-5597 User Manual

Dual Brite
OPERATION
Mode: On-Time: Works: Day Night
Test 5 Sec x x Auto 1, 5, 20 min. x Manual Until Dawn* x
Motion Sensor Light Control for Canadian Tire
Model SL-5597
Features
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Lamp
Holders
6 Screws
(3 sizes included)
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
TEST
Put ON-TIME switch on the sensor bottom to TEST and the Dual Brite™ switch OFF.
Put the ON-TIME switch in the 1, 5, or 20 minute position.
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
ON-TIME
TEST 1 5 20
AUTO
MANUAL MODE
DUAL BRITE™
Off 3 6 Dusk to
Dawn
ON-TIME
TEST 1 5 20
1 Second OFF
then
...
Manual mode works only with the ON-
Cover
Plate
Gasket
Sensor
Light Control
TIME switch in the 1, 5, or 20 position.
... back on.
Mode Switching Summary
2 Wire
TEST
Move ON-TIME Switch to
1, 5, or 20 minutes
Mounting Bolt
Connectors
Mounting Strap
AUTO
Plastic Hanger
Rubber Plug
2 Lamps
(installed)
MANUAL MODE
Requirements
• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
© 2003 DESA Specialty Products™ 598-1038-03
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
Dual Brite™ TIMER
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1,5, or 20 minutes) then returns to dim mode.
Flip light switch off
for one second then
back on*
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
• Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3' (1 m).
• Use only T4 100W (max.), G8 tungsten halogen bi­pin 120 VAC lamps.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only: Swing the sensor head towards the clamp
screw joint.
Clamp Screw
Controls
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
Route all fixture wires through the large holes in the
gasket as shown.
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with wire connectors.
Black to Black
Mounting
Strap
Junction box ground wire to green ground screw on fixture.
White to White
Rubber Plug
Mounting Bolt
Gasket
Rotate the sensor head clockwise 180° so the
controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
BULB INSTALLATION.
NOTE: When re-lamping, turn power off and let the
fixture cool. To remove lamp shade, loosen set screw 2 full turns
with a small flat-head screwdriver. Turn shade counterclockwise and remove.
To remove bulb, pull straight out of fixture. To replace bulb, push bulb pins into lamp socket.
Check that the bulb is seated properly.
To reinstall lamp shade, place shade on fixture and
align notches on shade with tabs on fixture. Turn clockwise. Tighten set screw firmly.
WIRE THE LIGHT CONTROL.
Turn power off at the fuse or circuit breaker. Remove the existing light fixture. Install mounting strap to junction box using screws
appropriate for your junction box.
MOUNT THE LIGHT CONTROL.
Place the Mounting Bolt through the front of the
junction box cover. Push the small gasket hole over the Mounting Screw.
Make sure the wire connectors and wires are inside
the junction box. Align the Mounting Screw with the center hole in the Mounting Strap. Secure the fixture to the Mounting Strap.
Push the Rubber Plug firmly into place. If a wet location junction box was not used, caulk the
wall plate mounting surface with silicone weather sealant.
Lamp Shade
Set Screw
Lock Nuts
Keep lamps at least 2" (51 mm) from the
sensor and 2" (51 mm) from combustibles.
Adjust the lamp holders by loosening the lock nuts,
but do not rotate the lamp holders more than 180° from the factory setting.
Adjust lamp shades by loosening the set screws
several turns, turn shades counterclockwise and remove. Reinstall the shades in the desired posi­tion and tighten set screws.
2
598-1038-03
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.
Turn the RANGE control to the mid position, Dual
Brite™ to OFF and the ON-TIME control to the TEST position.
MAX
MIN
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
(2.4 m)
Maximum
Range
The control is most sensitive to motion across it.
B
ON - TIME DUAL BRITE
O
O
S
T
RANGE
TEST 1 5 2 0
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
Bottom of Sensor
Avoid aiming the sensor at:
70 ft. 100 ft.
(21 m) (30.5 m)
Boosted
Maximum
Coverage Angle
Motion
240°
Motion
Loosen the clamp screw in the
sensor ball joint and gently ro-
Clamp Screw
tate the sensor.
Walk through the coverage area
noting where you are when the lights turn on. Move the sensor
Ball Joint
head up, down, or sideways to change the coverage area.
Keep the sensor at least 2" (51 mm) away from the lamps.
Adjust the RANGE as needed.
Too much range may increase false triggering. Range Boost
Aim Sensor
Down for Short
Coverage
increases coverage up to 100 feet.
Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you
Aim Sensor
Higher for Long
Coverage
want the lights to stay on after motion is detected (1, 5, or 20 minutes).
Set the DUAL BRITE™ switch to the amount of time
after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m); 100
ft.(30.5 m) with Range Boost. [varies with surrounding
temperature]
Sensing Angle . . . . . . . . Up to 240°
Electrical Load. . . . . . . . Up to 200 Watts Maximum
Incandescent (Up to 100
Watts Maximum each lamp
holder.) Power Requirements. . . 120 VAC, 60 Hz
Operating Modes. . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . . 1 , 5, 20 minutes
Dual Brite™ Timer. . . . . 3, 6 hours, Dusk-to-Dawn
Replacement lamp . . . . T4 100W, G8 halogen bi-pin
120 VAC DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
Sensor
Least Sensitive Most Sensitive
598-1038-03
3
TROUBLESHOOTING GUIDE
If you experience a problem, follow this guide.
SYMPTOM Lights will
not come on.
Lights come on in daylight.
Lights come on for no apparent reason.
Lights turn off too late in Dusk-to­Dawn setting.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turnoff is in effect
after dark)
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover desired area.
1. Light Control may be installed in a relatively dark location.
2. Light Control is in Test.
.
switch to an ON-TIME position)
1. Light Control may be sensing small animals or automobile traffic
sensor)
2. Range is set too high.
setting)
3. Dual Brite™ Timer is on.
1. Sensor is in a relatively dark location.
.
.
(recheck
(Set control
.
(re-aim
(Reduce Range
(Relocate sensor, or use 3 hr or 6 hr setting)
.
SYMPTOM Lights stay
on continu­ously.
Lights flash on and off.
Lights flash once, then stay off in Manual Mode.
POSSIBLE CAUSE
1. A lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor.
(Reposition the lamp away from the sensor or nearby objects)
2. Light Control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface.
.
(Reposition sensor. Reduce Range)
3. Light Control is in Manual Mode.
(Switch to Auto)
1. Heat or light from the lamps may be turning the Light Control on and off.
.
(Reposition the lamps away from the sensor)
2. Heat being reflected from other ob­jects may be affecting the sensor.
(Reposition sensor)
3. Light Control is in the Test mode and warming up.
.
.
(Flashing is normal un-
der these conditions. Turn Boost off)
1. Sensor is detecting its own lights.
(Reposition lamps to keep area be­low the sensor relatively dark).
.
.
See your Canadian Tire retailer for warranty information.
4
598-1038-03
Loading...
+ 8 hidden pages