OPERATION
Mode: On-Time: Works: Day Night
Test 5 Sec x x Auto 1, 5, 10 min. x Manual Until Dawn* x
* resets to Auto Mode at dawn.
1
Note: When first turned on wait about 1 the circuitry to calibrate.
/2 minutes for
Model SL-5525
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night). This package includes:
Plastic Hanger
6 Screws
(3 sizes included)
1 Halogen
Lamp
Sensor
3 Wire
Connectors
Mounting Strap
Gasket
Light Control
TEST
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the 1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night because daylight returns the sen­sor to AUTO.
Flip the light switch off for one sec­ond then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Mounting Bolt
Rubber Plug
Light Shield
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
• Some codes require installation by a qualified electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
© 2004 DESA Specialty Products™ 595-5295-11
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
Mode Switch Summary
TEST
Move ON-TIME Switch to
1, 5, or 10 minutes
AUTO
Flip light switch off
for one second
then back on*
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
• Keep fixture at least 1" (2.5 cm) from combustible materials. Do not aim at objects closer than 3 ft. (1 m).
• Use only T3, 250W (max.) tungsten halogen 120 VAC lamps.
Note the position of the various parts of the fixture
for the type of installation for your application and adjust the lamp head and sensor as shown below.
Wall Mount
Lens Retainer
Light Shield,
with opening at
this side
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper opera- tion and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective
backing from the Light Shield and stick on as shown below.
Eave Mount
Lens Retainer
BULB INSTALLATION.
When relamping, turn power off and let the fixture
cool.
Remove glass cover and remove the old bulb by
pushing the bulb towards the socket indicated on the metal reflector.
To insert the new bulb, follow the instructions printed
on the metal reflector.
Check that the bulb is seated properly. Reinstall the glass cover.
WIRE THE LIGHT CONTROL.
Turn the power to the lighting circuit off at the
fuse or circuit breaker box.
Remove the existing light fixture. Install mounting strap to junction box using screws
appropriate for your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
Thread all fixture wires through the large holes in
the gasket as shown.
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with wire connectors.
Mounting Strap
Black to Black
White to White
Rubber
Plug
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
Clamp Screw
Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Light Shield
Opening
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Controls
Mounting
Bolt
Gasket
Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.
MOUNT THE LIGHT CONTROL.
Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.
Push the Rubber Plug firmly into place. If a wet location junction box was not used, caulk the
wall plate mounting surface with silicone weather sealant.
2
595-5295-11
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch. NOTE: Sensor has about 1 1/2 minutes warm up
period before it will detect motion. When first turned on, wait about 1 1/2 minutes.
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range Maximum
Coverage Angle
The detector is most sensitive to motion across its field of view.
RANGE
MIN MAX
180°
Loosen the clamp screw in
the sensor ball joint and gen­tly rotate the sensor.
Walk through the coverage
area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the coverage area. Keep the
sensor at least 1" (2.5 cm) away from the lamp.
Adjust the RANGE as
needed. RANGE set too high may increase false triggering.
Secure the sensor head
by tightening the clamp screw. Do not overtighten
the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Clamp Screw
Ball Joint
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 180°
Electrical Load. . . . . . . Up to 250 Watts Maximum In-
candescent. Power Requirements. . 120 VAC, 60 Hz
Operating Modes. . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . T3, 250W (or less) halogen
120 VAC DESA Specialty Products™ reserves the right to discon-
tinue products and to change specifications at any time without incurring any obligation to incorporate new fea­tures in products previously sold.
Motion
Sensor
Motion
Least Sensitive Most Sensitive
595-5295-11
3
TROUBLESHOOTING GUIDE
SYMPTOM Light will not
come on.
Light comes on in daylight.
Light comes on for no apparent reason.
Lights flash once, then stay off in Manual Mode.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect
after dark)
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover desired area.
1. Light control may be installed in a relatively dark location.
2. Light control is in test.
.
(recheck
(Set control
switch to an ON-TIME position.)
1. Light control may be sensing small animals or automobile traffic
aim sensor)
2. Sensitivity is set too high.
.
(re-
(Reduce
sensitivity.)
1. Sensor is detecting its own light.
(Reposition lamp to keep area be­low the sensor relatively dark.)
SYMPTOM Light stays on
continuously.
Light flashes on and off.
POSSIBLE CAUSE
1. The lamp is positioned too close to the sensor or pointed at nearby ob­jects that cause heat to trigger the sensor.
(Reposition the lamp away
from the sensor or nearby objects.)
2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective sur­face.
(Reposition sensor.)
3. Control is in Manual Mode.
(Set to
Auto.)
1. Heat or light from the lamp may be turning the Light Control on and off.
(Reposition the lamp away from the sensor.)
2. Heat being reflected from other ob­jects may be affecting the sensor.
(Reposition sensor.)
3. Light Control is in the Test mode and warming up.
der these conditions)
4. If eave installation, Light Shield not installed properly.
(Flashing is normal un-
.
(Install Light Shield
according to instructions.)
TECHNICAL SERVICE
Please call 1-800-858-8501 for assistance before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™ ATTN: Technical Service Specialty Products P.O. Box 90004, Bowling Green, KY 42102-9004
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WAR­RANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUEN­TIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAM­AGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for warranty claims.
TEN YEAR LIMITED WARRANTY
4
595-5295-11
Loading...
+ 8 hidden pages