Heath Zenith SL-5512 User Manual

DualBrite® Twin Halogen
Motion Sensing Light
Model SL-5512
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Some code s requ ir e in st al la tion by a
qualified electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
DualBrite® Timer.
• LED indicates motion was sensed (day or night).
This package includes:
Rubber Plug
Plastic Hanger
Light Control
Cover
Plate
Sensor
6 Mounting
Screws (3 sizes)
3 Wire
Connectors
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual Accent
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put ON-TIME switch on the sensor bottom to TEST and the Dual-
Brite® switch OFF.
Put the ON-TIME switch in the 1, 5, or 20 minute position.
5 Seconds x x
1, 5, or 20 Min x
To Dawn* x
3, 6 Hr, to Dawn x
* resets to Auto Mode at dawn.
TEST
ON-TIME
TEST 1 5 20
AUTO
DualBrite
Off 3 6 Dusk to Dawn
ON-TIME
TEST 1 5 20
®
MANUAL MODE
Mounting Bolt
2 Halogen Bulbs
© 2008 HeathCo LLC 595-5575-09
Mounting Strap
Light Shield
Gasket
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
INSTALLATION
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
DualBrite® Timer
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.
For easy installation, select an existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
CAUTION: Keep the sensor at least 1" (2.5 cm) away from the lamps.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).
• Use only T3, 150W (max.) tungsten halogen 120 VAC lamps.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the light shield and stick on as shown below.
NOTE:
If fixture is mounted higher than
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
Controls
Clamp Screw
Then rotate the sensor head clockwise 180° so
the controls face down.
Light Shield
Opening
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Controls
Controls
2
595-5575-09
Bulb Installation
NOTE: Lamps are included, but you will need to install
them NOTE: When re-lamping, turn power off and let the fixture cool. Open glass covers. To remove the old bulb push
the bulb towards the right until the left side of the bulb is clear of the left socket.
To install a bulb, push the bulb into the right socket
so the bulb fits completely into the left socket.
Check that the bulb is seated properly. Close the glass covers.
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture. ❒ Install mounting strap to junction box using screws
appropriate for your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
Thread all fixture wires through the large holes in
the gasket as shown.
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with wire connectors.
Mount the Light Control
Place the mounting bolt through the front of the
junction box cover. Push the small gasket hole over the mounting bolt.
Make sure the wire connectors and wires are inside
the junction box. Align the mounting bolt with the center hole in the mounting strap. Secure the fixture to the mounting strap.
Push the rubber plug firmly into place.
Mounting Bolt
Rubber Plug
If not installed on a weatherproof box, caulk the
wall plate and mounting surface with silicone.
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180° from the factory setting.
Push the rubber plug over the mounting bolt.
CAUTION: Do not cut any wires with factory installed wire connectors.
White to White
Mounting Strap
Gasket
Connect green or bare copper wire(s) in the fixture to green ground screw and ground wire in junc­tion box. Note: All ground wires shown as green in above illustration.
595-5575-09
Black to Black
Keep lamps at least 1" (2.5 cm) from the sensor.
3
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME DUAL BRITE
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it.
MotionMotion
Sensor
Least Sensitive Most Sensitive
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
240°
8 ft.
(2.4 m)
70 ft.
(21 m)
100 ft. (30.5 m) Boosted
Maximum Range Maximum Coverage Angle
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage
area noting where you are
Clamp Screw
Ball Joint
when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
least 1" (25 mm) away from
Aim Sensor
Down for Short
Coverage
the bulbs.
Adjust the RANGE as needed.
RANGE set too high may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Aim Sensor
Higher for Long
Coverage
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Set the DualBrite® switch to the amount of time after
dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
4
595-5575-09
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost. [vari es wi th surr ou nding
temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 300 Watt Maximum Incan-
descent [Up to 150 Maximum
each lamp holder]. Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . T3, 150W halogen maximum
120 VAC
DualBrite® Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come on.
Lights come on in day­light.
Lights come on for no apparent reason.
Lights turn off too late in Dusk-to-Dawn setting.
Lights stay on continu­ously.
Lights flash on and off. 1. Heat or light from the lamps may be turning the light
Lights flash once, then stay off in man ual mode.
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST.
1. Light control may be sensing small animals or auto­mobile traffic.
2. Range is set too high.
3. DualBrite® timer is on.
Light control may be installed in a relatively dark loca­tion.
1. A lamp is positioned too close to the light control or pointed at nearby objects that cause heat to trigger the light control.
2. The light control may be picking up a heat source like an air vent, dryer vent, or brightly painted, heat­reflective surface.
3. Light control is in manual mode.
control on and off.
2. Heat being reflected from other objects may be turn­ing the light control on and off.
3. Light control is in the TEST mode and warming up.
Light control is detecting its own lights. Reposition flood lamps to keep area below the light
1. Turn light switch on.
2. Check flood lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
1. The fixture is operating normally under these condi­tions.
2. Set control switch to 1, 5, or 10 minutes.
1. Re-aim light control.
2. Reduce range.
3. The fixture is operating normally under these condi­tions.
Relocate light control, or use 3 hr. or 6 hr. setting.
1. Reposition the flood lamp away from the light control or nearby objects.
2. Reduce range.
3. Switch light control to AUTO.
1. Reposition the flood lamp away from the light con­trol.
2. Reposition light control.
3. Flashing is normal under these conditions.
control relatively dark.
595-5575-09
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to: HeathCo LLC P.O. Box 90045, Bowling Green, KY 42102-9045 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modifica­tion of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROF­ITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
6
595-5575-09