As an ENERGY STAR® Partner, Heath®/Zenith
has determined that this product meets the
ENERGY STAR® guidelines for energy efficiency. This product is ENERGY STAR
pliant when used with 120 Watt bulbs.
Model SL-5408
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
®
com-
OPERATION
Mode:On-Time:Works:DayNight
Test5 Secxx
Auto1, 5, 10 min.x
ManualUntil Dawn*x
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
TEST
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the 1, 5, or
10 minute position.
MANUAL MODE
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
Lamp Holders
Light Control
Cover
Plate
Sensor
4 Mounting
Screws (2 sizes)
Gasket
2 Wire
Connectors
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with a junction box
marked for use in wet locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may be
needed. Adaptors are available at home centers and
electrical supply stores.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ONTIME switch in the 1, 5, or 10 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
TEST
Move ON-TIME Switch to
1, 5, or 10 minutes
AUTO
Flip light switch off
for one second then
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
For easy installation, select an existing light operated by
a wall switch for replacement.
For best performance, mount the fixture about
8 feet (2.4 m) above the ground.
❒ Drill the holes needed to
mount the backplate to
the junction box.
Wall MountEave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Rotate the sensor head towards the clamp screw
joint.
Control Switch
❒ Turn power off at the fuse or circuit breaker.
❒ Remove the existing light fixture.
❒ Route the Light Control's wires through the large
gasket hole.
❒ Connect the junction box wires to the Light Control
wires. Twist together and secure with a wire
connector.
Black to
White to
White
Black
Gasket
MOUNTTHE LIGHT CONTROL.
❒ Align the Light Control cover plate and the junction
box holes. Secure with the mounting screws.
❒ If not installed on a weatherproof box or if an
adaptor plate (not included) was used, caulk thewall plate and mounting surface with silicone.
Avoid water damage and
electrical shock - keep lamp
holders below horizontal.
Joint Clamp
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
Keep lamps at
least 1" (25 mm)
Lock nuts
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
2
from the sensor.
595-5292-18
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
❒ Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST
position.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
ON-TIME
10 5 1 TEST
Bottom of Sensor
SENS
MINMAX
❒ Loosen the clamp screw in
the sensor ball joint and gently rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the coverage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.
❒ Adjust the SENSITIVITY as
needed. Too much sensitivity
may increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you
want the lights to stay on after motion is detected (1,
5, or 10 minutes).
Down for Short
Higher for Long
Clamp
Screw
Ball
Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
60 ft.
(18.3 m)
110°
Maximum RangeMaximum
Coverage Angle
The detector is most sensitive to motion across its field
of view.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 110°
Electrical Load. . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any
time without incurring any obligation to incorporate
new features in products previously sold.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
595-5292-18
3
TROUBLESHOOTING GUIDE
SYMPTOM
Lights will not come
on.
Lights come on
in daylight.
Lights come on for
no apparent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Flood light is loose or
burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect
check after dark)
5. Incorrect circuit wiring, if this is a
new installation.
6. Re-aim the sensor to cover desired area.
1. Light Control may be installed in
a relatively dark location.
2. Light Control is in Test.
(Set control switch to an
ON-TIME position)
1. Light Control may be sensing
small animals or automobile traffic
(re-aim sensor)
2. Sensitivity is set too high.
duce sensitivity.)
.
.
.
(re-
(Re-
TECHNICAL SERVICE
SYMPTOM
Lights stay on
continuously.
Lights flash on
and off.
POSSIBLE CAUSE
1. A flood lamp is positioned too close to
the sensor or pointed at nearby objects that cause heat to trigger the
sensor.
from the sensor or nearby objects)
2. Light Control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
3. Light Control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the lamps may be
turning the Light Control on and off.
(Reposition the lamps away from the
sensor)
2. Heat being reflected from other objects may be affecting the sensor.
(Reposition sensor)
3. Light Control is in the Test mode and
warming up.
der these conditions)
4. Light may be leaking through the
floodlamp reflectors.
with new high quality PAR 38 lamps)
(Reposition the lamp away
(Reposition sensor)
.
(Flashing is normal un-
.
.
.
(Replace the lamps
.
.
Please call 1-800-858-8501 for assistance before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the
problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
DESA Specialty Products™
ATTN: Technical Service Specialty Products
P.O. Box 90004, Bowling Green, KY 42102-9004
* If contacting Technical Service, please have the following information available: Model Number, Date of
Purchase, and Place of Purchase.
No Service Parts Available for this Product
TWO YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state
to state or province to province.
For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship
will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries,
and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or
of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for
inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and
components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE
FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO
LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS,
WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for
warranty claims.