Motion Sensor
Light Control with
Protective Lamp
Shields
Model SL-5330
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
•
Photocell keeps the lighting off during daylight hours.
This package includes:
Lamp Holders
Mounting Strap
OPERATION
Mode: On-Time: Works: Day Night
Test 5 Sec x x
Auto 1, 5, 20 min. x
Manual Until Dawn* x
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
TEST
Put ON-TIME switch on the sensor
bottom to TEST.
AUTO
Put the ON-TIME switch in the 1, 5
or 20 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
ON-TIME
TEST 1 5 20
ON-TIME
TEST 1 5 20
Rubber Plug
Cover
Plate
Light Control
Mounting Bolt
Connectors
2 PAR Lamps
2 Wire
Sensor
Plastic Hanger
Gasket
6 Screws
(3 sizes included)
Requirements
• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must
be wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
1 Second OFF
then...
... back on.
Mode Switching Summary
TEST
Move ON-TIME Switch to
1, 5 or 20 minutes
AUTO
Flip light switch off
for one second then
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
back on*
© 2003 DESA Specialty Products™ 598-1131-01
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
23456789012345678
Wall Mount Eave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
Controls
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mounting
Strap
Junction box ground wire to
green ground screw on fixture.
Black to
Black
White to
White
Rubber
Plug
Mounting
Bolt
Gasket
MOUNT THE LIGHT CONTROL.
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.
WIRE THE LIGHT CONTROL.
❒ Turn power off at the fuse or circuit breaker.
❒ Remove the existing light fixture.
❒ Install the mounting strap as shown using two
screws that fit your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of the
cover plate. The small end then goes into one of the
slots on the mounting strap.
❒ Route the Light Control’s wires through the large
gasket hole.
❒ Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Push the Rubber Plug firmly into place.
❒ If a wet location junction box was not used, caulk the
wall plate mounting surface with silicone weather
sealant.
To avoid water damage and
electrical shock, keep lamp
holders below horizontal.
Keep lamps at least
1" (2.5 cm) from the
sensor. Do not allow
Lock Nut
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
CAUTION: To avoid fire or burn hazards, keep
fixture at least 2" (51mm) from combustible materials. Do not aim at objects closer than 3' (1m).
Lens
the lamps to block
the lens.
2
598-1131-01