As an ENERGY STAR® Partner, Heath®/Zenith has determined that this product meets
the ENERGY STAR® guidelines for energy
efficiency. This product is ENERGY STAR®
compliant when used with 120 Watt bulbs.
Model SL-5411
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Lamp
Holders
Cover
Plate
Mounting Bolt
Sensor
Light Control
Mounting Strap
Rubber Plug
Plastic Hanger
2 Wire
Connectors
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
TEST
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the
1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Mode Switching Summary
Move ON-TIME Switch to
1, 5, or 10 minutes
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require ins t a l lation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
❒ Route the light control’s wires through the large
gasket holes.
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Wall Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Eave Mount
Controls
Mounting
Strap
Junction box ground wire to
green ground screw on fixture.
Black to
Black
White to
White
Rubber
Plug
Mounting
Bolt
Gasket
Mountthe Light ControL
❒ Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Push the rubber plug firmly into place.
❒ If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Wirethe Light ControL
WARNING: Turn power off at the fuse or circuit
breaker.
❒ Remove the existing light fixture.
❒ Install the mounting strap as shown using two screws
that fit your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
To avoid water damage and
electrical shock, keep lamp
holders 30° below horizontal.
Keep lamps at least
1" (2.5 cm) from the
Lock Nut
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
sensor. Do not allow
the lamps to block
the lens.Lens
2
595-4884-20
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
❒ Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
RANGE
MIN MAX
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the coverage area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Down for Short
Higher for Long
Clamp
Screw
Ball
Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
150°
Maximum Range Maximum
Coverage Angle
The detector is most sensitive to motion across its field
of view.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 150°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
595-4884-20
3
TROUBLESHOOTING GUIDE
SYMPTOM
Lights will not come
on.
Lights come o n
in daylight.
Lig hts come on
for no apparent
reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. F l ood li g ht is lo o se or
burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect
check after dark).
5. Incorrect circuit wiring, if this is a
new installation.
6. Re-aim the sensor to cover de
sired area.
1. Light control may be installed in
a relatively dark location.
2. Li g h t control is i n Te s t .
(Se t c o ntrol s witc h t o a n
ON-TIME position).
1. Light control may be sensing
small animals or automobile traffic (re-aim sensor).
2. R a nge is set to o h i g h.
(Reduce Range).
(re-
SYMPTOM
Lights stay on
continuously.
-
Lights flash on
and off.
POSSIBLE CAUSE
1. A flood lamp is positioned too close to
the sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the lamp away from the
sensor or nearby objects).
2. Light control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface. (Reposition sensor).
3. Light control is in Manual Mode.
to Auto.)
1. Heat or light from the lamps may be
turning the light control on and off.
(Reposition the lamps away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-tion sensor).
3. Light control is in the Test mode and
warming up. (Flashing is normal under these conditions).
4. Light may be leaking through the flood
lamp reflectors. (Replace the lamps with
new high quality PAR 38 lamps).
(Switch
-
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com.
If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST
(M-F). You may also write* to:
HeathCo LLC, P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state
to state or province to province.
For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship
will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries,
and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of
any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components
that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY
WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR
ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL,
OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO
LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT
FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for
all warranty requests.
4
595-4884-20
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.