Heath Zenith SL-4190 User Manual

Motion Sensing Diecast Lantern
SL-4190 Series
Meets the ENERGY STAR® guidelines when DualBrite® function is off.
Features
• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight hours.
OPERATION
Mode: On-Time Works: Day Night Test 5 Seconds x x Auto 1, 5, or 10 Min x Manual To Dawn* x Accent 3, 6 Hr, to Dawn x
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2
minutes for the circuitry to calibrate.
TEST
Set the ON-TIME switch on the bottom of the cover plate to TEST.
AUTO
Set ON-TIME switch to 1, 5, or 10 minutes.
TEST 1 5 10 MIN
TEST 1 5 10 MIN
This package includes:
• Lantern
• Easy to use universal mounting bracket (X-Bar)
• Mounting hardware
• Wire nuts
Requirements
• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes require installation by a
qualified electrician.
MANUAL MODE
Manual mode only works at night because daylight re­turns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
1 Second
OFF then...
... back on.
© 2007 HeathCo LLC 595-5628-08
Mode Switching Summary
MANUAL MODE
AUTO
TEST
INSTALLATION
ON-TIME Switch at 1,
5, or 10 minutes
Flip light
switch off for
one second
then back on*
* If you get confused while switching modes,
turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
DualBrite® Dimmer Control
Light comes on half bright for selected time af­ter dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 10 minutes) then returns to dim mode.
For best performance, mount the fixture about 6 feet (1.8 m) above the ground.
WARNING: Turn power off at circuit
breaker or fuse.
1. Remove
two nuts.
3. Tighten screws
finger tight.
MIN
2. Remove
X-Bar.
SENSITIVITY
MAX
4. Set sensitivity on
fixture back to the
mid-position.
5. Attach X-Bar to
junction box
Junction
Box
Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in place while connecting the wires.
2
595-5628-08
WIRING
Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means.
Contact a qualified electrician if there is any question as to the suitability of the system.
CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor.
Twist the junction box wires and the
fixture wires together as shown below. Secure with wire connectors. If you have a metal junction box, you may not need the green “pigtail”. If you are unsure about the grounding method, consult your local building code.
Connect the fixture wires to the wires in the junction box. Twist the wires together and secure with wire connectors.
or Bare
White
Black
Green
or Bare
Black
Green
White
One Motion Light
Light
Fixture
Two Motion Lights
Light
Fixture
Light
Fixture
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the “pigtail” with the GND screw on the X-bar.
Black to black
White to white
595-5628-08
3
OPTIONAL WIRING
This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of additional load may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp wattage for which the fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture: Strip the motion sensor’s red wire and connect to the standard light’s black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light fixture (Master / Slave): Strip the red wire in both light fixtures. Connect the red wire of the controlling (master) fixture to the red and black wires of the controlled (slave) fixture. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Master Slave
Light
Fixture
Wiring Diagram 2
Red
Light
Fixture
White
Black
Green
or Bare
Light
Fixture
Wiring Diagram 1
(Standard)
White
Light
Fixture
Red
Black
Green
or Bare
It is also possible to wire two motion lights so that either fixture will turn on both lights at the same time (dual master system). It is recommended that only people with plenty of electrical experience attempt this configuration. Please call our customer service number (1-800-858­8501 - English speaking only) before attempting this wiring. If the dual master wiring is not
done correctly, it can destroy both motion sensing fixtures and void your warranty.
4
595-5628-08
COMPLETE THE INSTALLATION
Stuff the wires into the junction box. Make
sure none of the wires get pinched.
Slide the fixture onto the
mounting screws and
tighten nuts.
Junction
Box
❒ Install one 100 Watt maximum light bulb, or
three 60 Watt bulbs in candelabra style.
❒ Install the fixture top. Secure with
decorative screws.
After completing the tests on page 5, caulk
fixture mounting surface with silicone
weather sealant.
Model 4193 Glass Installation
Corner Guides
Rubber Bumpers
❒ Model 4193 only: install the six pieces
of glass by sliding them down as shown. The glass panels should rest upon the corner guides on each side, and against the rubber bumpers at the bottom.
Note: As with any glass, handle with care.
595-5628-08
5
TESTING
Turn on the circuit breaker and light
switch.
The detector is less sensitive to motion di­rectly towards it and more sensitive to across motion.
NOTE: Sensor has a 1 1/2 minute warm up pe-
riod before it will detect motion. When first turned on, wait 1 1/2 minutes.
Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.
Switch the on-time to TEST position and
DualBrite® switch to the OFF position.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as heating vents and air condition- ers. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger
the control.
Nearby large, light-colored objects
reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
Motion
Sensor
Motion
Least Sensitive Most Sensitive
Walk through the coverage area noting
where you are when the lights turn on.
If you need to change the sensitivity,
temporarily remove the fixture and make the adjustment. Too much sensitivity may increase false triggering.
Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5, or 10 minutes).
Set the amount of time after dusk you want
the lights on accent level.
6 ft.
(1.8 m)
30 ft.
(9.1 m)
180°
Maximum Range Maximum Coverage Angle
6
595-5628-08
SPECIFICATIONS
Range . . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature]
Sensing Angle . . . . . Up to 180°
Electrical Load . . . . . See rating on fixture
for maximum wattage Sensor Capacity . . . Up to 360 Watts (3.0 A.)
Maximum Tungsten
Incandescent Power Requirements 120 VAC, 60 Hz Operating Modes . . . TEST, AUTO, and
MANUAL MODE
Time Delay . . . . . . . 1, 5, 10 minutes
DualBrite® Timer . . . Off, 3, 6 hours, dusk-to
dawn HeathCo LLC reserves the right to discontinue
products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM Light will not
come on.
Light comes on in daylight.
Light comes on for no apparent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (recheck after dark).
5. Incorrect circuit wiring, if this is a new installation.
1. Light control may be installed in a relatively dark location.
2. Light control is in Test. (Set
control switch to an ON-TIME position.)
1. Light control may be sensing small animals or automobile traffic (Reduce sensitivity).
2. Sensitivity is set too high. (Re-
duce sensitivity.)
SYMPTOM Light stays on
continuously.
Light flashes on and off.
POSSIBLE CAUSE
1. The sensor is pointed toward a heat source like an air vent, dryer vent, or brightly­painted heat-reflective surface.
(Reduce sensitivity.)
2. Light control is in Manual Mode.
(Switch to Auto.)
3. Light control is in DualBrite® mode.
4. Sensitivity is set too high. (Re-
duce sensitivity.)
1. Light control is in the Test mode an d war m i ng up .
(Flashing is n or mal under these conditions).
2. Heat being reflected from other objects may be affecting the sensor. (Reduce sensitivity.)
595-5628-08
7
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to: HeathCo LLC P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
FIVE YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of five years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equip­ment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUEN­TIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, IN­DIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
8
595-5628-08
Loading...
+ 16 hidden pages