TM
®
Dual Brite™
Motion Sensing
Coach Light
Models SL-4180/84 - A
Features
• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight hours.
This package includes:
Mounting screws
and wire
connectors
OPERATION
Mode: On-Time Works: Day Night
Test 5 Sec x x
Auto 1, 5 or 10 Min x
Manual To Dawn* x
Accent 3,6 Hr, to Dawn x
* resets to Auto Mode at dawn.
For TEST
Set the ON-TIME switch
on the bottom of the cover
plate to TEST.
For AUTO
Set ON-TIME switch to 1,
5 or 10 minutes.
For MANUAL OVERRIDE
Flip the light switch off for
one second then back on.
Manual override works
when the ON-TIME switch
is in any position.
TEST 1 5 10 MIN
TEST 1 5 10 MIN
1 Second OFF
then...
Grand
Manor
Candelabra
or
Tail Assembly
(Lantern & Coach)
Requirements
• The Light Control requires 120 volts AC.
• If you want to use Manual Override, the
control must be wired through a switch.
• Some codes require installation by a
qualified electrician.
Manual override only works
at night because daylight
returns the sensor to AUTO.
Mode Switching Summary
TEST
Turn
light
AUTO
switch
off for 10
Questions? Call 1-800-858-8501
8:00 AM to 4:45 PM Eastern Time,
weekdays.
Lo sentimos, pero no podemos contestar
preguntas en español por teléfono.
© Heath Company Printed in Hong Kong 595-5578
seconds
then
MANUAL OVERRIDE
back on*
* Wait one minute for sensor to warm up.
Dusk Accent Mode
Light comes on half bright for selected time
after dusk (Off, 3 hr., 6 hr., until dawn). If
motion is sensed, the light turns on full bright
for the ON-TIME (1, 5 or 10 minutes) then
returns to dim mode.
... back on.
ON-TIME
Switch at
1, 5 or 10
minutes
Flip light
switch
off for 1
second
then on
INSTALLATION
❒ Turn power off at circuit breaker.
1. Remove
two nuts.
2. Remove
Mounting Plate.
BLACK
WHITE
One Motion Light
OPTIONAL WIRING:
3. Set sensitivity range
SENS
MIN
MAX
4. Screw in mounting
on fixture back.
Junction
Box
plate to junction box.
Horizontal Junction Boxes Only:
Ground
Fixture
Screw
Notch
Junction
Box
Screws
Screw
Fixture
Screw
Remove ground screw and 2 fixture screws
from the mounting plate. Flip plate over and
rotate 90°. Re-insert ground screw. Insert the
2 fixture screws in the holes near the junction
box screws holes. Route wires through notch
in adaptor plate.
1. Connect Bare wire
to ground screw
BLACK
WHITE
Two Motion Lights
BLACK
WHITE
Wiring to Motion Light &
Standard Fixture
BLACK
RED to
BLACK
(Standard)
When wiring to additional standard
fixture only: Strip the motion sensor's
red wire and connect to the standard
light's black wire. Connect all white wires
together. Total fixture ratings must not
exceed 400W (3.3 A.).
Slide the fixture onto
the mounting screws
and tighten nuts.
2. White to white
❒ Caulk fixture and mounting surface
with silicone weather sealant.
❒ Install three 60W bulbs in candelabra
style lights.
3. Black to black