Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
Move ON-TIME Switch to
1, 5, or 20 minutes
For under eave installation, the sensor head must be
rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper
under eave operation, remove the protective backing
from the light shield and stick on as shown below.
Flip light switch
off for one second
then back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
DualBrite® Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
INSTALLATION
CAUTION: Keep the sensor at least 1" (25 mm)
away from the bulbs.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the
fixture operate at high temperatures.
• Keep fixture at least 1" (25 mm) from combustible materials. Do not aim at objects closer than 3 ft. (1 m).
• Use only T3, 150W (max.) tungsten halogen 120 VAC
bulbs.
For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 ft.
(2.4 m) above the ground. NOTE:
higher than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.
If fixture is mounted
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Controls
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
Light Shield
Opening
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Bulb Installation and Replacement
NOTE: Bulbs are included, but you will need to install
them
NOTE: When replacing bulbs, turn power off and let
the fixture cool.
❒ Open glass covers. To remove the old bulb push the
bulb towards the right (with fixture as shown) until
the left side of the bulb is clear of the left socket.
❒ To install a bulb, push the bulb into the right socket
so the bulb fits completely into the left socket.
❒ Check that the bulb is seated properly.
❒ Close the glass covers.
2
598-1160-03
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture.
❒ Install mounting strap to junction box using screws
appropriate for your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Thread all fixture wires through the large holes in
the gasket as shown.
❒ Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with
wire connectors.
Mount the Light Control
❒ Place the mounting bolt through the front of the
junction box cover. Push the small gasket hole over
the mounting screw.
❒ Make sure the wire connectors and wires are inside
the junction box. Align the mounting screw with the
center hole in the mounting strap. Secure the fixture
to the mounting strap.
Push the rubber plug
over the mounting screw.
Keep bulbs at least 1" (25
mm) from the sensor.
Mounting
Strap
Connect any fixture ground wire(s) and the cover
plate ground screw to the junction box ground
wire.
White to
White
Black to
Black
Rubber
Plug
Mounting
Bolt
Gasket
❒ Push the rubber plug firmly into place.
❒ If not installed on a weatherproof box, caulk the
wall plate and mounting surface with silicone
❒ Adjust the bulb holders by loosening the lock nuts
but do not rotate the bulb holders more than 180°
from the factory setting.
598-1160-03
3
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWN HOUR
B
O
O
S
T
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
NOTE: Meets the ENERGY STAR® guidelines when
DualBrite® function is off and ON-TIME is 1 or 5 minutes
and when used with 120 W Max bulbs.
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite® to OFF,
and the ON-TIME control to the TEST position.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
ualZone™
D
Sensor
Motion
ualZone™
D
Least Sensitive Most Sensitive
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
may trigger the shut-off feature. Do not point other
lights at the sensor.
240°
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
Clamp
Screw
Ball
Joint
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the coverage area. Keep the sensor at
least 1" (25 mm) away from
Aim Sensor
Down for Short
Coverage
the bulbs.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Aim Sensor
Higher for Long
Coverage
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the DualBrite® switch to the amount of time
after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).
8 ft.
(2.4 m)
DualZone™
70 ft. 100 ft.
D
ualZone™
(21 m) (30.5 m)
Boosted
Maximum
Maximum Range Coverage Angle
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
NOTE: DualZone™ is a new zone of detection which
was added as an option to select Heath®/Zenith motion
sensing products. This feature adds a zone of detection under the motion sensor. DualZone™ requires
no additional adjustment and operates in conjuction
with the forward-looking sensor.
4
598-1160-03
SPECIFICATIONS
Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[var ies with sur rounding
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 300 Watt Maximum Tung-
sten Halogen [Up to 150 Watt
Maximum each bulb holder.]
Power Requirements . 120 VAC, 60 Hz
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
SYMPTOM
Lights will
not come on.
Lights come
on in daylight.
Lights come
on for no
apparent
reason.
Lights turn
off too late
in Dusk-toDawn setting.
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect
after dark).
5. Incorrect circuit wiring, if this is a new
installation.
6. Re-aim the sensor to cover desired
area.
1. Light control may be installed in a
relatively dark location.
2. Light control is in TEST.
switch to an ON-TIME position).
1. Light control may be sensing small
animals or automobile traffic. (Re-aim sensor).
2. RANGE is set too high.
RANGE).
3. D
ualBrite
1. Sensor is in a relatively dark location.
(Relocate sensor, or use 3 hr or 6 hr
setting).
®
Timer is on.
(Recheck
(Set control
(Reduce
SYMPTOM
Lights stay
on continuously.
Lights flash
on and off.
Lights flash
once, then
stay off in
Manual Mode.
POSSIBLE CAUSE
1. A bulb is positioned too close to the
sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the bulb away from the
sensor or nearby objects).
2. Sensor is pointed toward a heat source
like an air vent, dryer vent, or brightlypainted heat-reflective surface. (Repo-sition sensor. Reduce RANGE).
3. Light control is in Manual Mode.
to Auto).
1. Heat or light from the bulbs may be
turning the light control on and off.
(Reposition the bulbs away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-tion sensor).
3. Light control is in the TEST mode and
warming up. (Flashing is normal under these conditions. Turn BOOST off).
1. Sensor is detecting its own lights.
(Reposition bulbs to keep area below
the sensor relatively dark).
(Switch
598-1160-03
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com.
If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST
(M-F). You may also write* to:
HeathCo LLC
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from
state to state or province to province.
For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or
workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs,
batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does
not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or
return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and
components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT
THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF
ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL
BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please
keep your dated sales receipt, it is required for all warranty requests.
6
598-1160-03
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.