Heath Zenith SH-5511 User Manual

Compact 150 Watt Motion Sensing Halogen
Model SH-5511
Requirements
• The light control requires 120-volts AC. Do not con-
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with a junction box marked for use in wet locations.
• The backplate has knockouts so the sensor can be mounted on most junction boxes.
• In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
6 Mounting
Screws (3 sizes)
Cover
Plate
Sensor
Gasket
Light Control
Mounting StrapMounting Bolt Rubber Plug
3 Wire
Connectors
OPERATION
Mode: On-Time: Works: Day Night
Test Normal Manual
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10 minute position.
5 Sec x x
1, 5, 10 min. x
Until Dawn* x
* resets to Auto Mode at dawn.
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
Plastic Hanger
© 2008 HeathCo LLC 598-1159-06
Halogen
Bulb
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
INSTALLATION
CAUTION to avoid fire or burn hazards:
• Allow fixture to cool before touching. The bulb and fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).
• Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only: Rotate the sensor head towards the clamp screw
joint.
For easy installation, select an existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
CAUTION: The sensor must be mounted
below the lamp housing for wall installations.
If fixture is mounted
Eave Mount
Wall Mount
Control Switch
Joint Clamp
Then rotate the sensor head clockwise 180° so the
controls face down.
2
598-1159-06
Bulb Installation and Relamping
When relamping, turn power off and let the fixture
cool.
Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.
To insert the new bulb, push the bulb into the right
socket so the bulb fits completely into the left socket.
Check that the bulb is seated properly. ❒ Close the glass cover. Replace screw.
Mount the Light Control
Align the light control cover plate and cover plate
gasket and the junction box. Insert and tighten the mounting screws.
If not installed on a weatherproof box or if an adaptor
plate is used, caulk the wall plate and mounting
surface with silicone weather sealant.
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
Remove the existing light fixture. Strip about 5/8" insulation from the existing junction
box wiring.
Route the light control’s wires through the large
hole in the gasket.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
White to White
Mounting
Strap
Black to Black
Rubber
Plug
Mounting
Bolt
RIGHT WRONG
The halogen light must be mounted horizontally (+/- 4°).
Gasket
Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.
598-1159-06
3
ON - TIME
1051
TEST
MIN MAX
SENS
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
Turn the SENSITIVITY (SENS) control to the position
(halfway between MIN and MAX)
ON-TIME control to the TEST position.
medium and the
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
(2.4 m)
110°
Loosen the clamp screw in the
sensor ball joint and gently
Clamp Screw
rotate the sensor.
Walk through the coverage
area noting where you are
Ball Joint
when the lights turn on. Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
least 1" (2.5 cm) away from the lamps.
Aim Sensor
Down for Short
Coverage
Adjust the SENSITIVITY
as ne ede d. Too mu c h sensitivity may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Aim Sensor
Higher for Long
Coverage
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
60 ft.
(18.3 m)
Maximum Range Maximum Coverage Angle
4
598-1159-06
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 110°
Electrical Load . . . . . . Up to 150 Watts Maximum tung-
sten Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
Replacement lamp . . . T 150W (or less) halogen 120
VAC
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM Light will not
come on.
Light comes on in daylight.
Light comes on for no apparent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Halogen lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (Recheck after dark).
5. Incorrect circuit wiring, if this is a new installation.
6. Not aimed correctly (Re-aim the sensor to cover desired area).
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST (Select 1, 5 or 10 minutes for AUTO time).
Light control may be sensing small
1. animals or automobile traffic (re-aim sensor).
2. Sensitivity is set too high (Reduce sensitivity).
SYMPTOM Light stays on
continuously.
Light flashes on and off.
POSSIBLE CAUSE
1. The halogen lamp is positioned too close to the light control's sensor or pointed at nearby objects that cause heat to trigger the sensor (Reposition
the lamp away from the sensor or nearby objects).
2. Light control's sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface (Reposition sensor).
3. Light control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the halogen lamp may be turning the light control on and off (Reposition the lamp away from the sensor).
2. Heat being reflected from other objects may be affecting the light control (Re-aim sensor).
3. Light control is in the TEST mode and warming up (Flashing is normal
under these conditions).
598-1159-06
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance
before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
HeathCo LLC P.O. Box 90045, Bowling Green, KY 42102-9045 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or
TWO YEAR LIMITED WARRANTY
province to province. For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be cor­rected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expend­able items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PUR­POSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
6
598-1159-06
Loading...
+ 14 hidden pages