Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
INSTALLATION
CAUTION to avoid fire or burn hazards:
• Allow fixture to cool before touching. The bulb
and fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible
materials. Do not aim at objects closer than 3 feet
(1 m).
• Re-lamp with type T 150W (or less) halogen 120
VAC lamp only.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Rotate the sensor head towards the clamp screw
joint.
For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE:
higher than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.
CAUTION: The sensor must be mounted
below the lamp housing for wall installations.
If fixture is mounted
Eave Mount
Wall Mount
Control Switch
Joint Clamp
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
2
598-1159-06
Bulb Installation and Relamping
❒ When relamping, turn power off and let the fixture
cool.
❒ Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.
❒ To insert the new bulb, push the bulb into the right
socket so the bulb fits completely into the left
socket.
❒ Check that the bulb is seated properly.
❒ Close the glass cover. Replace screw.
Mount the Light Control
❒ Align the light control cover plate and cover plate
gasket and the junction box. Insert and tighten the
mounting screws.
❒ If not installed on a weatherproof box or if an adaptor
plate is used, caulk the wall plate and mounting
surface with silicone weather sealant.
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture.
❒ Strip about 5/8" insulation from the existing junction
box wiring.
❒ Route the light control’s wires through the large
hole in the gasket.
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
White to White
Mounting
Strap
Black to Black
Rubber
Plug
Mounting
Bolt
RIGHTWRONG
The halogen light must be
mounted horizontally (+/- 4°).
Gasket
Connect any fixture ground wire(s) and the cover
plate ground screw to the junction box ground
wire.
598-1159-06
3
ON - TIME
1051
TEST
MINMAX
SENS
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
❒
Turn the SENSITIVITY (SENS) control to the
position
(halfway between MIN and MAX)
ON-TIME control to the TEST position.
medium
and the
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Halogen lamp is loose or burned
out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect (Recheck after dark).
5. Incorrect circuit wiring, if this is a new
installation.
6. Not aimed correctly (Re-aim the sensor to cover desired area).
1. Light control may be installed in a
relatively dark location.
2. Light control is in TEST (Select 1, 5 or 10 minutes for AUTO time).
Light control may be sensing small
1.
animals or automobile traffic (re-aim sensor).
2. Sensitivity is set too high (Reduce sensitivity).
SYMPTOM
Light stays on
continuously.
Light flashes
on and off.
POSSIBLE CAUSE
1. The halogen lamp is positioned too
close to the light control's sensor or
pointed at nearby objects that cause
heat to trigger the sensor (Reposition
the lamp away from the sensor or
nearby objects).
2. Light control's sensor is pointed toward
a heat source like an air vent, dryer
vent, or brightly-painted heat-reflective
surface (Reposition sensor).
3. Light control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the halogen lamp
may be turning the light control on
and off (Reposition the lamp away from the sensor).
2. Heat being reflected from other
objects may be affecting the light
control (Re-aim sensor).
3. Light control is in the TEST mode
and warming up (Flashing is normal
under these conditions).
598-1159-06
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance
before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com.
If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM
CST (M-F). You may also write* to:
HeathCo LLC
P.O. Box 90045, Bowling Green, KY 42102-9045
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or
TWO YEAR LIMITED WARRANTY
province to province.
For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will
void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use,
unauthorized service, or return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer
uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY,
REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE
PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT
LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please
keep your dated sales receipt, it is required for all warranty requests.
6
598-1159-06
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.