Heath Zenith SH-5408 User Manual

MANUAL MODE
AUTO
TEST
Motion Sensor
OPERATION
Mode: On-Time: Works: Day Night
Test Normal Manual
5 Sec x x
1, 5, 10 min. x
Until Dawn* x
Light Control
Model SH-5408
Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
Lamp Holders
4 Mounting
Screws (2 sizes)
Cover
Plate
Sensor
Light Control
2 Wire
Connectors
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
TEST
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the 1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
• The light control requires 120-volts AC.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
• In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.
© 2008 HeathCo LLC 598-1156-03
Requirements
Mode Switching Summary
Gasket
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
INSTALLATION
Wire the Light Control
For easy installation, select an existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
❒ Drill the holes needed
to mount the backplate to the junction box.
If fixture is mounted
WARNING: Turn power off at the fuse or circuit
breaker.
❒ Remove the existing light fixture. Route the light control’s wires through the large
gasket hole.
Connect the junction box wires to the light control
wires. Twist together and secure with a wire connector.
White to White
Gasket
Eave Mount Wall Mount
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only: Rotate the sensor head towards the clamp screw
joint.
Control Switch
Joint Clamp
Then rotate the sensor head clockwise 180° so the
controls face down.
Black to Black
Mount the Light Control
Align the light control cover plate and the junction
box holes. Secure with the mounting screws.
If not installed on a weatherproof box or if an adaptor
plate (not included) was used, caulk the wall plate and mounting surface with silicone.
Avoid water damage and electrical shock - keep lamp holders below horizontal.
Keep lamps at least 1" (25 mm) from the sensor.
Lock nuts
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the flood­lamps, do not overtighten.
2
598-1156-03
ON - TIME
1051
TEST
MIN MAX
SENS
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
The detector is most sensitive to motion across its field of view.
Motion
Motion
NOTE: Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.
Turn the SENSITIVITY (SENS) control to the position ON-TIME control to the TEST position.
(halfway between MIN and MAX)
medium
and the
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
Sensor
Least Sensitive Most Sensitive
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage
area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
least 1" (2.5 cm) away from the lamps.
Adjust the SENSITIVITY
as n e e ded . Too much sensitivity may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
Down for Short
Higher for Long
Clamp Screw
Ball Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
8 ft.
(2.4 m)
60 ft.
(18.3 m)
110°
Maximum Range Maximum Coverage Angle
598-1156-03
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 110°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.] Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
3
TROUBLESHOOTING GUIDE
SYMPTOM
Lights will not come on.
Lights come on in daylight.
Lights come on for no appa rent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. F l o od light is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect check after dark).
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover de sired area.
1. Light control may be installed in a relatively dark location.
2. Light con trol i s in Test.
(Se t c ontr o l swi t ch to an ON-TIME position).
1. Light control may be sensing small animals or automobile traf­fic (re-aim sensor).
2. Sensitivity is set too high. (Reduce
sensitivity.)
(re-
SYMPTOM
Lights stay on continuously.
-
Lights flash on and off.
POSSIBLE CAUSE
1. A flood lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor.
(Reposition the lamp away from the sensor or nearby objects).
2. Light control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective sur­face. (Reposition sensor).
3. Light control is in Manual Mode.
to Auto.)
1. Heat or light from the lamps may be turning the light control on and off.
(Reposition the lamps away from the sensor).
2. Heat being reflected from other objects may be affecting the sensor. (Reposi- tion sensor).
3. Light control is in the Test mode and warming up. (Flashing is normal under these conditions).
4. Light may be leaking through the flood lamp reflectors. (Replace the lamps with
new high quality PAR 38 lamps).
(Switch
-
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance
before returning product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
HeathCo LLC P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or
TWO YEAR LIMITED WARRANTY
province to province. For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be cor­rected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expend­able items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PUR­POSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
4
598-1156-03
Detector de Movimiento y Control de Luz
Modelo SH-5408
Cumple con las normas ENERGY STAR® cuando usa bombillas de 120 W máximo.
Características
• Prende la luz cuando detecta movimiento.
• Apaga la luz automáticamente.
• La fotocélula mantiene la luz apagada durante el día.
Este paquete tiene:
Porta-lámparas
Requisitos
• El control de luz requiere 120 VCA.
• Para usar el Sobrecontrol Manual, conecte el control con un interruptor.
Algunos códigos requieren instalación por un
electricista calificado.
• Se recomienda usar este producto con el empaque provisto y con una caja de empalme marcada para uso en lugares húmedos.
• La placa trasera tiene discos removibles para poder montar el detector en casi todas las cajas de empal­mes.
• En algunas aplicaciones se puede necesitar una placa adaptadora. Los adaptadores se pueden comprar en los Centros Comerciales para el Hogar y en las Tiendas de Aparatos Eléctricos.
FUNCIONAMIENTO
Fase: Tiempo de encendido: Trabaja: día noche
Prueba Autom. Manual
*Se pone en Automático al amanecer.
Nota: Cuando lo prenda por primera vez espere 1 1/2 minutos hasta que el circuito se calibre.
5 segundos x x
1, 5, 10 minutos x
Hasta el amanecer* x
Placa
Cubertora
Control de Luz
Detector
4 Tornillos
(2 dimensiones)
2 Tuercas para
Alambre
Empaquetadura
Para PRUEBA:
Ponga el interruptor de tiempo (ON­TIME), al fondo del detector, en la posición de prueba (TEST).
Para AUTOMATICO:
Ponga el control de tiempo (ON-TIME) en la posición de 1, 5 ó 10 minutos.
Para MODO MANUAL:
El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO .
Apague el interruptor por un segundo y vuélvalo a prender.
El modo manual funciona sólo cuando el interruptor de tiempo (ON-TIME) está en la posición de 1, 5 ó 10 minutos.
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 segundo APAGADO
luego...
...préndalo.
598-1156-03
© 2008 HeathCo LLC 598-1156-03 S
5
Loading...
+ 11 hidden pages