Heath Zenith SH-5407 User Manual

TEST
Replacement Motion Sensor
Model SH-5407
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes require installation by a qualifi ed
electrician.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the 1, 5, or 10 minute position.
MANUAL MODE
Manual mode only works at night because daylight returns the sen­sor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
OPERATION
Mode: On-Time: Works: Day Night
Test Normal Manual
Note: When fi rst turned on wait about 11/2 minutes
5 Sec x x
1, 5, 10 min. x
Until Dawn* x
* resets to Auto Mode at dawn.
for the circuitry to calibrate.
* If you get confused while switching modes, turn the
Mode Switching Summary
TEST
AUTO
MANUAL MODE
power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip switch off for
one second then
back on*
INSTALLATION
For under eave installation, the sensor head must be rotated as shown in the next two steps
for proper operation and to avoid the risk of elec­trical shock.
For eave mount only:
Swing the sensor head towards the clamp
screw.
Clamp Screw
Controls
After screwing the sensor into the wall plate,
connect the junction box wires to the light control wires by twisting together and securing with wire connectors.
Red Sensor Wire to
White to White
Junction
Box
Black Lamp Wire
Lamp Holders
Rotate the sensor head clockwise 180° so
the controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
These instructions show the sensor wired to fl ood­lamps. The white sensor wire is neutral. The black sensor wire is hot. The red wire is the switched "hot" wire. The lighting load (500 W, 4.2A max) is placed across the white and red wires.
WIRE THE LIGHT CONTROL
WARNING: Turn power off at circuit breaker
or fuse.
Black to Black
Optional: Connect additional load
across the white and red wires. Total lighting load including lampheads on fi xture must not exceed 500W (4.2A).
MOUNT THE LIGHT
Follow the instructions that came with your light fi x-
ture for mounting and adjusting the light fi xture.
Keep regular PAR-38 lamps at least 1" (25 mm)
from the sensor. Halogen lamps should be kept at least 2" (51 mm) from the sensor.
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute calibration
period before it will detect motion. When fi rst turned on, wait 1 1/2 minutes.
Remove the existing light fi xture, if present.
-2-
598-1155-01
Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
10 5 1 TEST
MINUTES
RANGEON-TIME
MAXMIN
RANGE
MIN MAX
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffi c may trigger the control.
Nearby large, light-colored objects refl ecting light may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
180°
(2.4m)
70 ft.
(21m)
Maximum Range Maximum Coverage Angle
The sensor is less sensitive to motion directly to­wards it, most sensitive to motion across its fi eld of view.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
Loosen the clamp screw
in the sensor ball joint and
Clamp Screw
gently rotate the sensor.
Walk through the cover-
age area noting where
Ball
Joint you are when the lights turn on (also, the LED will fl ash several times when motion is detected). Move the sensor head up, down, or sideways to change
Aim Sensor
Down for Short
Coverage
the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps.
Adjust the RANGE as
needed. RANGE set too high may increase false
Aim Sensor
Higher for Long
Coverage
triggering.
Secure the sensor head by tightening the
clamp screw. Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fi re. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . . Up to 180°
Electrical Load . . . . . . . . Up to 500 Watt (4.2A) Maximum
Incandescent [Up to 250 Watt
maximum each lamp holder.] Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . . 1 , 5, 10 minutes
Range . . . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.