DualBrite
®
Motion Sensor
Light Control with
2-Level Lighting
Models SH-5318
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• DualBrite® Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Lamp Holders
Rubber Plug
OPERATION
Mode: On-Time Works: Day Night
Test
Auto
Manual
Accent
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual-
Brite® switch OFF.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
5 Seconds x x
1, 5, or 20 Min x
To Dawn* x
3, 6 Hr, to Dawn x
* resets to Auto Mode at dawn.
TEST
ON-TIME
TEST 1 5 20
AUTO
DualBrite
Off 3 6 Dusk to
Dawn
ON-TIME
TEST 1 5 20
MANUAL MODE
®
Plastic Hanger
Cover Plate
Sensor
Light Control
Mounting Bolt
2 Shells*
* Model SL-5318 only
Mounting Strap
6 Screws
(3 sizes included)
2 Wire
Connectors
Gasket
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require ins t a l lation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2007 HeathCo LLC 598-1154-01
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
1 Second OFF
then...
... back on.
Mode Switching Summary
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
DualBrite® Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mounting
Strap
White to
White
Black to
Black
Rubber
Plug
Wall Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Eave Mount
Controls
Mounting
Bolt
Gasket
Junction box ground wire to
green ground screw on fixture.
Mount the light Control
❒ Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Align the three slots in the decorative shell with the
lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
❒ Push the rubber plug firmly into place.
Shell Slot
❒ If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
Wire the light Control
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fixture.
❒ Install the mounting strap as shown using two screws
that fit your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Route the light control’s wires through the large
gasket holes.
To avoid water damage and electrical shock,
keep lamp holders 30° below horizontal.
Keep lamps at least
1" (2.5 cm) from the
Lock Nut
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
2
sensor. Do not allow
the lamps to block
the lens.Lens
598-1154-01
TEST AND ADJUSTMENT
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWNHOUR
B
O
O
S
T
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
❒ Turn the RANGE control to the mid position,
DualBrite® to OFF and the ON-TIME control to the
TEST position.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
•
may trigger the shut-off feature. Do not point other
lights at the sensor.
240°
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range Maximum
Coverage Angle
The detector is most sensitive to motion across its field
of view.
100 ft.
(30.5 m)
Boosted
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
Clamp
Screw
Ball
Joint
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the coverage area. Keep the sensor at
least 1" (2.5 cm) away from
Aim Sensor
Down for Short
Coverage
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Aim Sensor
Higher for Long
Coverage
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the DualBrite® switch to the amount of time after
dusk you want the lights on at low level (Off, 3, 6
Hrs., Dusk-to-Dawn).
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost. [varies
with surrounding temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite® Timer . . . . 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
598-1154-01