Heath Zenith SH-5316 User Manual

MANUAL MODE
AUTO
TEST
DualBrite® Replacement
Sensor Head
Model SH-5316
TEST
Put ON-TIME switch on the sensor bottom to TEST and the Dual-
Brite® switch OFF.
Put the ON-TIME switch in the 1, 5, or 20 minute position.
Manual mode only works at night because daylight returns the sensor to AUTO.
ON-TIME
TEST 1 5 20
AUTO
MANUAL MODE
DualBrite
Off 3 6 Dusk to Dawn
®
ON-TIME
TEST 1 5 20
Features
DualZone™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard bulbs. Lights bulb to full bright in under 2 seconds.
• Patented DualBrite® Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Requirements
• Not for use with fluorescent lights.
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Install sensor in accordance with local codes.
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual Accent
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
5 Seconds
1, 5, or 20 Min
To Dawn*
3, 6 Hr, to Dawn
* resets to Auto Mode at dawn.
x x
x x x
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
DualBrite® Timer
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.
© 2008 HeathCo LLC 598-1153-02
INSTALLATION
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only: Swing the sensor head towards the clamp screw
joint.
Then rotate the sensor head clockwise 180° so
the controls face down.
NOTE:
Clamp Screw
If fixture is mounted higher than
Controls
Wire the Light Control
WARNING: Turn power off at circuit breaker
or fuse.
These instructions show the sensor wired to floodlamps. The white sensor wire is neutral. The black sensor
wire is hot. The red wire is the switched “hot” wire. The lighting load (500 Watts, 4.2 A max. incandescent only) is placed across the white and red wires.
Remove the existing light fixture, if present. After screwing the sensor into the wall plate, con-
nect the junction box wires to the light control wires by twisting together and securing with wire connectors.
2. RED CONTROL WIRE & BLACK FIXTURE WIRES
1. ALL WHITE WIRES
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Junction Box
Bulb Holders
3. BLACK
CONTROL WIRE & JUNCTION BOX
BLACK
WIRE
Optional: Connect additional load across the white and red wires. Total lighting load including bulb holders on fixture must not exceed 500W (4.2A).
Mount the Light
Follow the instructions that came with your light
fixture for mounting and adjusting the light fixture.
Keep regular PAR-38 bulbs at least 1" (25 mm)
from the sensor. Halogen bulbs should be kept at least 2" (51 mm) from the sensor.
2
598-1153-02
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWN HOUR
B
O
O
S
T
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
Turn the RANGE control to the medium position
(halfway between MIN and MAX),DualBrite® OFF, and the ON-TIME control to the TEST position.
Bottom of Sensor
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control. Nearby large, light-colored objects reflecting light
• may trigger the shut-off feature. Do not point other lights at the sensor.
240°
15 ft.
(4.6 m)
70 ft. 100 ft.
DualZone
(21 m) (30.5 m) Boosted
Maximum Maximum Range Coverage Angle
NOTE:
the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it.
If fixture is mounted higher than 8 ft. (2.4 m), aiming
Motion
ualZone
D
Least Sensitive Most Sensitive
598-1153-02
Sensor
D
ualZone
Motion
DualZone
Loosen the clamp screw
in the sensor ball joint and
Clamp Screw
gently rotate the sensor.
Walk through the coverage
area noting where you are when the lights turn on (also,
Ball Joint
the LED will flash several times when motion is detect­ed). Move the sensor head up, down, or sideways to change the coverage area. Keep the
sensor at least 1" (25 mm) away from the bulbs.
Aim Sensor
Down for Short
Coverage
Adjust the RANGE as needed.
RANGE set too high may increase false triggering.
Secure the sensor head's
aim by tightening the clamp screw. Do not overtighten the
Aim Sensor
Higher for Long
Coverage
screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Set the DualBrite® switch to the amount of time
after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
NOTE: DualZone™ is a new zone of detection which
was added as an option to select Heath®/Zenith motion sensing products. This feature adds a zone of detec­tion under the motion sensor. DualZone™ requires no additional adjustment and operates in conjuction with the forward-looking sensor.
SPECIFICATIONS
Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost. [var ie s with sur round in g
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 500 Watts Maximum In-
candescent Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite® Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
3
TROUBLESHOOTING GUIDE
SYMPTOM Lights will
not come on.
Lights come on in day­light.
Lights come on for no apparent reason.
Lights turn off too late in Dusk-to­Dawn setting.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (Recheck
after dark)
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover desired area.
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST. (Set control
switch to an ON-TIME position)
1. Light control may be sensing small animals or automobile traffic. (Re-aim sensor).
2. RANGE is set too high. (Reduce RANGE).
3. DualBrite® Timer is on.
1. Sensor is in a relatively dark location.
(Relocate sensor, or use 3 hr or 6 hr setting).
.
.
SYMPTOM Lights stay
on continu­ously.
Lights flash on and off.
Lights flash once, then stay off in Manual Mode.
POSSIBLE CAUSE
1. A bulb is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor.
(Reposition the bulb away from the sensor or nearby objects)
2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly­painted heat-reflective surface.
sition sensor. Reduce RANGE)
3. Light control is in Manual Mode. (Switch to Auto)
1. Heat or light from the bulbs may be turning the light control on and off.
(Reposition the bulbs away from the sensor).
2. Heat being reflected from other objects may be affecting the sensor.
tion sensor)
3. Light control is in the TEST mode and warming up. (Flashing is normal under
these conditions. Turn BOOST off)
1. Sensor is detecting its own lights.
(Reposition bulbs to keep area below the sensor relatively dark)
.
.
.
(Repo-
.
(Reposi-
.
.
4
598-1153-02
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to: HeathCo LLC P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modifica­tion of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROF­ITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
598-1153-02
5
Repuesto DualBrite® Para el Cabezal del Detector
Modelo SH-5316
FUNCIONAMIENTO
Modalidad: A tiempo: Trabaja: Día Noche
Prueba Autom. Manual
Adorno
*Se pone en Automático al amanecer.
Nota: Cuando lo prenda por primera vez espere 1 1/2 minutos hasta que el circuito se calibre.
5 seg.
1, 5 ó 20 min.
Hasta el
amanecer*
3, 6 hrs, hasta
el amanecer
Para PRUEBA:
x x
x x
x
Características
• Tecnología DualZone™.
• Prende la luz cuando detecta movimiento.
• Apaga la luz automáticamente.
Bulb Saver™ - Prolonga la vida de la bombilla hasta 4 ve­ces con respecto a las bombillas estándar. Las bombillas alcanzan la brillantez total en menos de 2 segundos.
• Temporizador luz de dos niveles, DualBrite
• La fotocélula mantiene la luz apagada durante el día.
• LED indica que se ha detectado movimiento (durante el día o la noche).
®
Requisitos
• No utilizable con luces fluorescentes.
• El control de luz requiere 120 VCA.
• Para usar el Modo Manual, conecte el control con un interruptor.
Instale el detector de acuerdo a los códigos
locales.
Ponga el interruptor de tiempo (ON-TIME), al fondo del detector, en la posición de prueba (TEST) y DualBrite® a apagado (OFF).
Para AUTOMATICO:
Ponga el control de tiempo (ON­TIME) en la posición de 1, 5 ó 20 minutos.
Para MODO MANUAL:
El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO.
Apague el interruptor por un segundo y vuélvalo a prender.
El modo manual funciona sólo cuando el interruptor de tiempo (ON­TIME) está en la posición de 1, 5 ó
20 minutos.
ON-TIME
TEST 1 5 20
DualBrite
Off 3 6 Dusk to Dawn
®
ON-TIME
TEST 1 5 20
1 segundo
APAGADO
luego...
...préndalo.
© 2008 HeathCo LLC 598-1153-02 S