Heath Zenith SH-5311 User Manual

Professional Motion Sensor Quartz Security Light
Model SH-5311
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard bulbs. Lights bulb to full bright in under 2 seconds.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
6 Screws
(3 sizes included)
S-hook
Cover Plate
Gasket
1 Halogen
Lamp
Requirements
• This fixture is designed for wall mounting only.
• If you want to use Manual Override, the control must be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
• The backplate has knockouts so the sensor can be mounted on most junction boxes.
• In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.
OPERATION
Mode: On-Time: Works: Day Night
Test Normal Manual
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
5 Sec x x
1, 5, 10 min. x
Until Dawn* x
* resets to Auto Mode at dawn.
TEST
ON-TIME
10 5 1 TEST
Cover
Plate
Sensor
Light Control
© 2008 HeathCo LLC 598-1343-00
3 Wire
Connectors
Put the ON-TIME switch in the 1, 5, or 10 minute position.
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
Wire the Light Control
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
INSTALLATION
CAUTION: Risk of fire. This fixture is designed for wall mounting only. DO NOT install on a ceiling or soffit.
For easy installation, select an existing light operated by a wall switch for replacement.
For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
If fixture is mounted
Attach the lamp arm to
the backplate arm and secure with the long bolt.
WARNING: Turn power off at circuit breaker
or fuse.
Remove the existing light fixture. The S-hook can be used to hold the fixture while
wiring. The small end of the hook can be inserted into a hole in the junction box. The large end goes around the “neck” of the fixture.
Route the light control’s wires through the large
hole in the gasket.
Twist the junction box wires and fixture wires together
as shown. Secure with a wire connector.
Black to Black
Cover Plate
Gasket
White to White
Junction box ground wire to green ground wire on fixture.
❒ Drill out the holes if needed
to mount the backplate to the junction box.
Note: When tightening the arm screw, pull on the wires to make sure the wires are not pinched by the joint.
2
598-1343-00
Mount the Light Control
Align the light control cover plate and cover plate
gasket and the junction box. Insert and tighten the mounting screws.
If not installed on a weatherproof box or if an adaptor
plate is used, caulk the wall plate and mounting surface with silicone weather sealant.
+/- 4°
Bulb Installation and Re-lamping
When re-lamping, turn power off and let the fixture
cool.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
• Keep fixture at least 2" (51 mm) from combustible ma­terials. Do not aim at objects closer than 3 ft. (1 m).
• Re-lamp with type T halogen, 500 W max., 120 VAC lamp only.
MOUNT HORIZONTALLY
The halogen light must be
mounted horizontally (+/- 4°).
❒ Remove glass cover and remove the old bulb by
pushing the bulb towards the right until the left side of the bulb is clear of the left socket.
To insert the new bulb, push the bulb into the right
socket so the bulb fits completely into the left socket.
Check that the bulb is seated properly. Re-install the glass cover.
For proper operation and safety, the light fixture must be above the sensor and the sensor head must be rotated so that the controls are on the bottom.
598-1343-00
3
TEST AND ADJUSTMENT
MAXMIN
RANGEON-TIME
10 5 1 TEST
MINUTES
Turn on the circuit breaker and light switch.
NOTE: Sensor has about 1 1/2 minutes warm up period
before it will detect motion. When first turned on, wait about 1 1/2 minutes.
Turn the RANGE control to the mid position (halfway
between MIN and MAX) and the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range Maximum Coverage Angle
RANGE
MIN MAX
180°
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage
area noting where you are when the lights turn on (also,
Clamp Screw
Ball Joint
the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the cover­age area.
Adjust the RANGE as needed.
Aim Sensor
Down for Short
Coverage
RANGE set too high may increase false triggering.
Secure the sensor head
by tightening the clamp screw. Do not overtighten
the screw.
Set the amount of TIME you
Aim Sensor
Higher for Long
Coverage
want the lights to stay on after motion is detected (1, 5, or 10 minutes).
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 500 Watts Maximum
Tungsten. Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . . T, 500W (or less) halogen 120
VAC HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance. The detector is most sensitive to motion across its field
of view.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
4
598-1343-00
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Light will not come on. 1. Light switch is turned off.
Light comes on in day­light.
Light comes on for no apparent reason.
Light stays on continu­ously.
Light flashes on and off.
Light flashes once, then stays off i n manual mode.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST.
1. Light control may be sensing small animals or auto­mobile traffic.
2. Range is set too high.
1. A lamp is positioned too close to the light control or pointed at nearby objects that cause heat to trigger the light control.
2. The light control may be picking up a heat source like an air vent, dryer vent, or brightly painted, heat­reflective surface.
3. Light control is in manual mode.
1. Heat or light from the lamps may be turning the light control on and off.
2. Heat being reflected from other objects may be turn­ing the light control on and off.
3. Light control is in the TEST mode and warming up.
Light control is detecting its own lights. Reposition lamp to keep area below the light control
1. Turn light switch on.
2. Check lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.
1. The fixture is operating normally under these condi­tions.
2. Set control switch to 1, 5, or 10 minutes.
1. Re-aim light control.
2. Reduce range.
1. Reposition the lamp away from the light control or nearby objects.
2. Re-aim light control. Reduce range.
3. Switch light control to AUTO.
1. Reposition the lamp away from the light control.
2. Reposition light control.
3. Flashing is normal under these conditions.
relatively dark.
598-1343-00
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to: HeathCo LLC P.O. Box 90045, Bowling Green, KY 42102-9045 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modifica­tion of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROF­ITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.