Heat & Glo 6000TV-OAK-IPI User Manual

Model:
6000TV-OAK 6000TV -OAK-IPI
READ THIS MANUAL BEFORE INSTALLING OR OPERA TING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.
WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTL Y, A FIRE OR EXPLOSION MAY RESULT CAUS­ING PROPERTY DAMAGE, PER­SONAL INJURY, OR DEA TH.
Owner’s Manual
Installation and Operation
Underwriters
Laboratories Listed
WARNING: IMPROPER INSTALLA­TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM­AGE. REFER TO THIS MANUAL. FOR ASSIST ANCE OR ADDITIONAL INFOR­MATION CONSULT A QUALIFIED IN­ST ALLER, SERVICE AGENCY , OR THE GAS SUPPLIER.
- Do not store or use gasoline or other flam­mable vapors and liquids in the vicinity of this or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Printed in U.S.A. Copyright 2005
Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 481 1534, 5000162, 5016609, 5076254, 51 13843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.
1.This appliance may be installed in an af­termarket, permanently located, manufac­tured (mobile) home, where not prohibited by local codes.
2. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
• a CO detector shall be installed in the room where the appliance is installed.
Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer , please call 1-888-427-3973.
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05
1
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully
!
before starting the installation. FAILURE TO FOLLOW these installation instructions may result
in a possible fire hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the
!
Using Your Fireplace section of the Owners Guide.
DO NOT USE this appliance if any part has been
!
under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
!
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting
!
system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways adequate combustion and ventilation air.
BE KEPT CLEAN to provide for
These units MUST use one of the vent systems described in the Installing the Fireplace section of
!
the Installers Guide. NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be
!
vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to
!
make sure that no debris is interfering with the air flow.
The glass door assembly MUST be in place and
!
sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass
!
door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.
Always KEEP the appliance clear and free from
!
combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and
!
ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.
Due to the high temperature, the appliance should be LOCATED out of traffic areas and away from
!
furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the
!
hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Y oung children should be CAREFULL Y SUPERVISED when they are in the same room as the appliance.
The glass door assembly SHALL ONLY be
!
replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.
DO NOT USE abrasive cleaners on the glass door
!
assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician
!
perform an appliance check-up at the beginning of each heating season.
Any safety screen or guard removed for servicing
!
must be replaced before operating this appliance.
DO NOT place furniture or any other combustible
!
household objects within 36 inches of the fireplace front.
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/052

TABLE OF CONTENTS

Safety and Warning Information. ............................................... 2
Î
Service Parts Lists. .................................................................... 4
Section 1: Approvals and Codes............................................... 8
Appliance Certification................................................................... 8
Installation Codes.......................................................................... 8
High Altitude Installations............................................................... 8
Section 2: Getting Started ......................................................... 9
Introducing the Heat & Glo Gas Fireplaces................................... 9
Pre-installation Preparation........................................................... 9
Section 3: Installing the Fireplace...........................................11
Constructing the Fireplace Chase ...............................................11
Step 1 Locating the Fireplace ..................................................11
Step 2 Framing the Fireplace.................................................. 12
Step 3 Negative Pressure Make-up Air ................................... 12
Step 4 Installing the Vent System............................................ 13
A. Vent System Approvals........................................... 13
B. System Components ............................................. 13
C. Bedroom Installation in Canada ............................. 14
D. Vent Termination .................................................... 14
Step 5 Positioning, Leveling, and
Securing the Fireplace................................................. 14
Step 6 The Gas Control Systems........................................... 14
Step 7 The Gas Supply Line ................................................... 15
Step 8 Gas Pressure Requirements ...................................... 15
Î
Step 9 Wiring the Fireplace .................................................... 16
Step 10 Finishing ...................................................................... 18
Step 1 1 Installing Trim, Logs, and Ember Material.................... 18
Installing the Trim......................................................... 18
Positioning the Logs .................................................... 18
Shutter Settings........................................................... 18
Placing the Ember Material.......................................... 18
Glass Specifications ..................................................... 19
Step 12 Before Lighting the Fireplace ....................................... 19
Step 13 Lighting the Fireplace .................................................. 19
After the Installation..................................................................... 19
Section 4: Maintaining and Servicing Your Fireplace ......... 20
Î = Contains updated information.
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05
3
Service Parts
6000TV -OAK, 6000TV -OAK-IPI
(NG , LP) Exploded Parts Diagram
3
2
Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______
4
12
Part number list on following page.
5
1
6 Log Set Assembly
9
8
13
7
10
11
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/054
Service Parts List
6000TV-OAK, 6000TV -OAK-IPI
IMPORTANT: THIS IS DA TED INFORMA TION. The most current information is located on your dealers VIP site. When order-
ing, supply serial and model numbers to ensure correct service parts.
ITEM COMMON PARTS SERIAL # PART NUMBER
1Burner NG, LP SRV383-338A 2 Glass Door Assembly GLA-6TROC 3 Surround 4Hood SRV60-143-BK 5 Log Grate 383-360A 6 Oak Log Set Assembly LOGS-6OAK 7 Log 1 SRV385-720 8 Log 2 SRV385-724 9 Log 3 SRV385-721
10 Log 4 SRV385-723
11 Log 5 SRV385-722
PRE 002324021 POST 002324021
385-130 2026-108
12 Combustion Board 385-401
Touch Up Paint TUP-GBK- 1 2 Glass Latch Assembly 386-122A
Mineral Wool Embers 050-721
Vermiculite Embers MYSTI C- EMBERS High Temp L imit Switch 066-531 Pilot Orifice NG 446-505 Pilot Orifice LP 446-517
STANDING PILOT IGNITION ONLY
13 Junction Box
Thermocouple 446-511
Thermopile 060-512
Conversion Kit NG NGK-6TVOC
Conversion Kit LP LPK-6TVOC
INTERMITTENT PILOT IGNITION (IPI) ONLY
13 Junction Box
Conversion Kit LP LPK-6TVOC-IPI
PRE 002324021 POST 002324021
PRE 002324021 POST 002324021
100-250A 4021-013
383-250A 4021-013
ACCESSORIES
Trim Door Mesh MESH- 6 00 0 Fan Kit GFK-160A
Wall Switch Kit, Off-white
Wall Switch Kit, White WSK-21-W
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05
WSK-21
5
Service Parts
6000TV-OAK-IPI
Intermittent Pilot Ignition
Valve Assembly
1
(NG , LP) Exploded Parts Diagram
11
8
Beginning Manufacturing Date: 4-01
Ending Manufacturing Date: ______
9
7
3
4
6
2
10
5
ITEM DESCRIPTION SERIAL # PART N O .
1 Fle x B all Va lve A ss e m b ly 302-320A 2 ON/OFF Ro ck e r Swi tch 060-521A 3Valve NG 750-500 3 Valve LP 750-501
4 Flexible Gas Connector 5 Module 593-592
6Wire Assembly 593-590A
Burner Orifice NG (#40C) 582-840
7
Burner Orifice LP (#53C) 582-853
8Pilot Assembly NG 8Pilot Assembly LP
9 Pilot Bracket 385-164
10 Valve Bracket
11 Ground S t r ap 2025-512
3V Adaptor Plug 593-593A Battery Pack 593-594A 72" & 80" W i re Assembly 522-504A
PRE 002324021 POST 002324021
PRE 002324021 POST 002324021 PRE 002324021 POST 002324021
PRE 002324021 POST 002324021
477-301A 383-302A
385-510A 4021-025 385-511A
4021-026
550-169 2025-101
Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/056