Hearthstone DVI44 User Manual

Read This Manual in Its Entirety
Operate And Maintain This Gas Heater According
To This Instruction Manual.
SAVE THESE INSTRUCTIONS!
DVI 44
(Model 8860)
GAS-FIRED
Owner's Manual
Installation
&
Operating Instructions
.
WARNING: FOLLOW THE INFORMATION IN THESE
INSTRUCTIONS EXACTLY, IF NOT, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: DO NOT STORE OR USE GASOLINE OR
ANY OTHER FLAMMABLE VAPORS AND LIQUIDS NEAR THIS OR ANY OTHER GAS APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance. Do not touch electrical switches; do not use the phone in
your building.
Immediately call your gas supplier from a phone outside
the structure. Follow your gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department or 911.
A qualified installer, service agency, or gas supplier must perform installation and service of this appliance. In the Commonwealth of Massachusetts, all installation of gas lines and gas fittings must be performed by a licensed gas fitter or licensed plumber.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉERIEL, TOUTE BLESSURE OU LA MORT.
AVERTISSEMENT: NE PAS ENTRESPOSER NI
UTILISER D’ESSENCE NI D’AUTRE VAPERURS OU
LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE CET APPRAREIL OU DE TOUT AUTRE APPAREIL.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareil. Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le batiment où vous vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service dos incendies.
L’installation et service doit être exécuté par un qualifié installer,
agence de service ou le fournisseur de gaz.
Hearthstone Quality Home Heating Products, Inc. ®
DVI-44 Model 8860
Manual: 6400-404##
R: 8/2/2012
Intentionally Blank
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
3
Serial Number:
Fuel type:
Natural Gas
Liquid Propane
Sold by:
Date of Purchase:
Address:
Phone:
E-mail
Website:
Installed by:
Date of Installation:
Address:
Phone:
E-mail
Website:
Gas Supplier:
Address:
Phone:
E-mail
Website:
Date
Who Performed Work
Work Performed
Notes:
Information Sheet
Use this page to record all relevant information concerning the purchase, installation, and maintenance of your DVI 44 Model 8860 Direct-Vent Fireplace Insert. This information will facilitate servicing, purchase of replacement parts, and warranty claims (if necessary). Keep your original receipt as proof of purchase.
Read this Owner’s Manual before installing, or operating your DVI 44. Retain this manual for future reference.
SERVICE RECORD
WHAT WHEN
Firebox Cleaning............. annually
Glass Cleaning................ as needed
Door Gasket.................... Replacement as needed
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
4
Table of Contents
INTRODUCTION ........................................................................................................................................................... 5
SAFETY & GOOD PRACTICES ...................................................................................................................................... 6
SPECIFICATIONS ......................................................................................................................................................... 9
DVI 44 8860 Model Overview ................................................................................................................................... 11
Control Functions ..................................................................................................................................................... 14
INSTALLATION PREPARATION .................................................................................................................................... 16
Codes ....................................................................................................................................................................... 16
Items Required for Installation .................................................................................................................................. 16
Packing List .............................................................................................................................................................. 16
Unpacking and Inspection ........................................................................................................................................ 16
CLEARANCES TO COMBUSTIBLES .............................................................................................................................. 19
Clearance to Combustibles ...................................................................................................................................... 19
Hearth Requirement/Floor Protection ....................................................................................................................... 19
VENTING INFORMATION ............................................................................................................................................. 22
Venting Components ................................................................................................................................................ 22
ELECTRICAL SYSTEM INFORMATION .......................................................................................................................... 26
GAS SUPPLY & CONNECTIONS .................................................................................................................................. 27
Gas Connections ...................................................................................................................................................... 28
BAFFLE, LOG SET, & SCREEN PLACEMENT ............................................................................................................... 29
Installation of the Baffle ............................................................................................................................................ 29
Installation of the Log Set ......................................................................................................................................... 30
Completing the Installation ....................................................................................................................................... 30
Installation of the Screen .......................................................................................................................................... 31
Removal of Log Set .................................................................................................................................................. 31
Surround Installation ................................................................................................................................................. 32
Façade Installation ................................................................................................................................................... 32
LIGHTING & OPERATION ........................................................................................................................................... 33
Lighting Instructions .................................................................................................................................................. 33
Initial Adjustments .................................................................................................................................................... 33
Daily Operation ......................................................................................................................................................... 35
ROUTINE MAINTENANCE AND CARE ........................................................................................................................... 37
Cleaning ................................................................................................................................................................... 37
Monthly (or as needed): ............................................................................................................................................ 37
Annually: ................................................................................................................................................................... 37
As Needed: ............................................................................................................................................................... 39
REPLACEMENT PARTS & ACCESSORIES LIST ............................................................................................................. 40
TROUBLESHOOTING .................................................................................................................................................. 41
RATING LABEL ......................................................................................................................................................... 43
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
5
Introduction
Congratulations on your purchase of the DVI 44 Model 8860, Gas-Fired Direct-Vent Insert. The DVI 44, by Hearthstone, incorporates the latest in direct vent gas technology, which will provide you with ease of use, clean, and efficient heat for years to come. The DVI 44’s copious glass, sleek styling, and enameled or painted façade options gives the DVI 44 ambiance and a pleasing look that enhances any room.
However, as with any gas appliance, the unit must be properly and safely installed and maintained by qualified service personnel to ensure safe and trouble-free operation.
DVI 44 Model 8860 features:
1. The most realistic looking gas fire available today with highly detailed logs.
2. Heat Wave® refractory firebox liner to reflect the heat into your room in the most efficient way possible.
3. Real Platinum glowing embers, for instant glow and realism.
4. Child safety screen to reduce the risk of severe burns on the front glass.
5. Smart thermostatic remote control with split burner technology for a full range of heat output.
6. Integral, quiet, and efficient room air circulating fan – standard.
7. Battery backup to maintain basic functionality during power outages (up to a week on fresh batteries).
The Proflame System Features:
1. Thermostatic Remote Control
a. Twelve (12) flame levels, adjustable via
the remote b. Split Burner control via remote c. Six (6) blower speeds, adjustable via the
remote d. Thermostatic mode to turn on/off based
upon room temperature.
2. The option to toggle back and forth between an
3. “Child-safe” lock-out on remote control.
4. “Low Battery” indicator for Transmitter on remote
Operate and maintain this gas heater according to the instructions in this manual. For your safety, and years of trouble free operation, read this manual in its entirety.
Verify the gas connections and that venting systems supply adequate combustion and ventilation air to meet the requirements of local, regional or national installation codes. Qualified service personnel must inspect the gas heater before use, and at least annually.
Manufactured & warranted by:
Hearthstone Quality Home heating Products, Inc. 317 Stafford Ave. Morrisville, VT 05661
www.hearthstonestoves.com inquiry@hearthstonestoves.com
e. “Smart” thermostatic mode to modulate
flame levels automatically as the unit approaches the set point temperature.
f. Firebox Accent Light controlled by the
remote.
Intermittent (IPI) or Continuous (CPI) pilot mode via the remote.
a. The IPI (Summer) mode allows the most
efficient use of gas, burning the pilot only when the thermostat calls for the burner to ignite.
b. The CPI (Winter) mode runs the pilot
continuously keeping the firebox warmer thus promoting better draft in colder weather.
control
Read this Owner’s Manual
Insert Must Be Installed and Maintained By
Qualified Service Personnel
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
6
Safety & Good Practices
Your DVI 44 is an attractive and extremely efficient and easy to use heater, utilizing today’s best technologies. By following a few simple safety precautions and by performing minimal maintenance, the unit will remain appealing while providing years of quality performance.
The installation must conform to local codes or, in the absences of local codes, the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54) or CAN/CGA B149 Installation Code. (Installer
l’appareil selon les codes ou réglements locaux, ou,
en l’absence de tells réglements, selon les Codes d’installation CAN/CGA B149.)
CAUTION: DO NOT USE THIS APPLIANCE IF ANY
PART WAS UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND GAS CONTROL THAT HAS BEEN UNDER WATER. (NE PAS SE
SERVIR DE CET APPAREIL S’IL A ÉTÉ PLONGÉ DANS L’EAU, COMPLÉTEMENT OU EN PARTIE.
APPELER UN TECHNICIEN QUALIFIÉ POUR
INSPECTOR L’APPAREIL ET REMPLACER TOUTE
PARTIE DU SYSTÉME DE CONTRÔLE ET TOUTE COMMANDE QUI ONT ÉTÉ PLUNGES DANS
L’LAU.)
During the first few hours of operation the appliance may produce smoke and/or odor. This is normal during the first several burns and also after long periods when the stove is not burned. During these initial burns, open a window(s) to assist in the removal of the smoke/odor.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig. (3.5k Pa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5k Pa).
Fire Hazard
Do not store or use gasoline, other flammable vapors or liquids in the vicinity of this appliance. Locate the DVI 44 out of traffic areas and away from furniture, draperies, clothing, and flammable material.
Vent Only to the Outside
Never vent the gas heater to other rooms or buildings.
Service Caution
If you believe your DVI 44 is not in any way performing properly, immediately discontinue operation until the unit is inspected and approved by qualified service personnel. Prior to servicing the unit, turn the gas to the valve off, and disconnect any electrical source. Ensure the unit is cool prior to servicing and cleaning. Replace any safety screen,
guard, or component removed during servicing prior to operation. (Tout écran ou protecteur retiré
pour permettre l’entretien de l’appareil doit être remis
en place avant de mettre l’appareil en marche.) Use of
any components not supplied by Hearthstone on the stove voids all warranties. Do not substitute
components.
Proper Fuel
This gas heater is designed to burn natural gas (NG) or with conversion, liquid propane (LP). Never burn any fuel gas not intended for use with this unit. Never burn paper, wood, or other materials in this appliance.
This heater is factory equipped to burn natural gas (NG). To burn propane (LP), you must purchase an LP conversion kit 98-56601.
This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Cet appareil doit être atilisé
uniquement avec les types de gas indiqués sur la
plaque signalétique. Ne pas l’utiliser avec d’autres
gas sauf si un kited conversion certifié est installé. )
WARNING: THIS GAS APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE GAS OR SOLID-FUEL BURNING APPLIANCE
WARNING: DO NOT OPERATE THE APPLIANCE
WITH THE FRONT GLASS REMOVED, CRACKED, OR BROKEN. REPLACEMENT OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. ONLY OPEN FRONT FOR ROUTINE SERVICE. DO NOT SLAM FRONT OR STRIKE GLASS. AVERTISSEMENT. NE
PAS UTILISER L’APPAREIL SI LE PANNEAU FRONTAL EN VERRE N’EST PAS EN PLACE, EST
CRAQUÉ OU BRISÉ. CONFIEZ LE REMPLACEMENT DU PANNEAU À UN TECHNICIEN AGRÉÉ.
WARNING: HEARTHSTONE RECOMMENDS THAT
ONLY AN NFI CERTIFIED SERVICE TECHNICIAN INSTALLS, AND REPAIRS THIS APPLIANCE. A QUALIFIED SERVICE TECHNICIAN MUST
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
7
INSPECT THE APPLIANCE BEFORE USE, AND AT LEAST ANNUALLY. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, PETS, ETC. IT IS IMPERATIVE THAT THE CONTROL COMPARTMENTS, BURNERS, AND CIRCULATING AIR PASSAGES OF THE APPLIANCE ARE KEPT CLEAN AND FREE OF OBSTRUCTIONS.
(L’INSTALLATION ET LA RÉPARATION DEVRAIT
ÊTRE CONFIÉES À UN TECHNICIEN QUALIFIÉ.
L’APPAREIL DEVRAIT FAIRE L’OBJET D’UNE
INSPECTION PAR UN TECHNICIEN PROFESSIONNEL AVANT D’ÊTRE UTILISÉ ET AU MOINS UNE FOIS L’AN PAR LA SUITE. DES NETTOYAGES PLUS FRÉQUENTS PEUVENT ÊTRE NÉCESSAIRES SI LES TAPIS, LA LITERIE, ET CETERA PRODUISENT UNE QUANTITÉ IMPORTANTE DE POUSSIÈRE. IL EST ESSENTIEL QUE LES COMPARTIMENTS ABRITANT LES COMMANDES, LES BRÛLEURS ET LES
CONDUITS DE CIRCULATION D’AIR DE L’APPAREIL SOIENT TENUS PROPRES)
Hot Surfaces
Certain exposed surfaces of the DVI 44 will reach high temperatures during normal operation. Clearances to combustibles must be maintained, as specified in the “Clearances To Combustibles” section of this manual.
DUE TO HIGH TEMPERATURES THE APPLIANCE
SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE, DRAPERIES, CLOTHING AND FLAMMABLE MATERIALS. (EN
RAISON DES TEMPÉRATURES ÉLEVÉES, L’APPAREIL DEVRAIT ÊTRE INSTALLÉ DANS UN ENDROIT OÙ IL Y A PEU DE CIRCULATION ET LOIN DU MOBILIER ET DES TENTURES.)
CHILDREN AND ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS TO SKIN OR CLOTHING IGNITION.
(LES ENFANTS ET LES ADULTES DEVRAIENT ÊTRE INFORMÉS DES DANGERS QUE POSENT LES TEMPÉRATURES DE SURFACE ÉLEVÉES ET
SE TENIR À DISTANCE AFIN D’ÉVITER DES
BRÛLURES OU QUE LEURS VÊTEMENTS NE S’ENFLAMMENT.)
CAREFULLY SUPERVISE YOUNG CHILDREN
WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN, AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIER IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUALS IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE, INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN, AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES. (LES JEUNES
ENFANTS DEVRAIENT ÊTRE SURVEILLÉS
ÉTROITEMENT LORSQU’ILS SE TROUVENT DANS LA MÊME PIÈCE QUE L’APPAREIL. LES
TOUT PETITS, LES JEUNES ENFANTS OU LES ADULTES PEUVENT SUBIR DES BRÛLURES
S’ILS VIENNENT EN CONTACT AVEC LA
SURFACE CHAUDE. IL EST RECOMMANDÉ
D’INSTALLER UNE BARRIÈRE PHYSIQUE SI DES
PERSONNES À RISQUES HABITENT LA MAISON.
POUR EMPÊCHER L’ACCÈS À UN FOYER OU À
UN POÊLE, INSTALLEZ UNE BARRIÈRE DE SÉCURITÉ; CETTE MESURE EMPÊCHERA LES TOUT PETITS, LES JEUNES ENFANTS ET TOUTE
AUTRE PERSONNE À RISQUE D’AVOIR ACCÈS À
LA PIÈCE ET AUX SURFACES CHAUDES.)
CLOTHING OR OTHER FLAMMABLE MATERIAL
SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. (ON NE DEVRAIT PAS PLACER DE
VÊTEMENTS NI D’AUTRES MATIÈRES INFLAMMABLES SUR L’APPAREIL NI À
PROXIMITÉ.)
CLEAN THE AREA AROUND, UNDER, AND
BEHIND THE UNIT ON A REGULAR BASIS TO PREVENT THE ACCUMULATION OF DUST AND LINT.
Ceramic Logs, & Burner
If the decorative ceramic log, or burner material supplied with the DVI 44 are damaged or parts are missing, they must be replaced with the same, or approved Hearthstone replacement parts. These components affect the combustion quality and safety of the heater. Do not replace ceramic logs, or the burner with unapproved ceramic components or any other material.
We recommend you always wear gloves and safety goggles while handling the ceramic log set, and burner materials.
Electrical Hazard
Any three-prong grounded plug must be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from any plug or otherwise attempt to circumvent the grounding protection provided with the unit. The DVI 44 must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI.NFPA 70 in the U.S. or CSA C22.1 Canadian Electrical Code in Canada.
Do Not Light Pilot or Burner by Hand
The pilot light on this gas heater is lit using an electronic ignition module as described elsewhere in this manual. Never attempt to light the pilot or main burner by hand with a match or lighter.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
8
Mobile Home Installations
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home (USA only), where not prohibited by local codes.
(Cet appareil peut être installé dans un maison préfabriquée (mobile) déjá installée á demeure si les réglements locaux le permettent.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
9
Specifications
LISTED: Gas-Fired Direct-Vent Fireplace Heater
Model: DVI 44 Direct-Vent Gas Fireplace
Insert (8860) Testing Agency: Intertek Testing Services NA, Inc. (ITS) Tested to: ANSI Z21.88-09, CSA 2.33-09, CAN/CGA2.17-M91 Certified for Canada, CSA P.4.1-02 Approved for Mobile Home Installation (see page 8)
Certified for use by:
Board of State Examiners of Plumbers & Gasfitters 100 Cambridge Street, Room 1511 Boston, MA 02202 www.mass.gov
Figure 1 - Model 8860 Dimensions (Inches)
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
10
Specification
NG
LP
INPUT RATING (Btu/hr) (0-610 m)
43,000
46,000
MAXIMUM OUTPUT (Btu/hr) (0-610 m)
28,478
31,496
MINIMUM INPUT (Btu/hr) (0-610m)
15,000
17,000
HIGH ALTITUDE RATING (Btu/hr) 610-1370 m
36,000
37,000
ORIFICE SIZE (DMS) 0-610 m (front/rear))
46F/38R
55F/53R
MANIFOLD PRESSURE - (in. W.c./kpa)
3.5/0.87
10.0/2.48
MANIFOLD PRESSURE - Low setting (in. W.c./kpa)
1.6/0.40
6.4/1.59
INLET PRESSURE - MINIMUM (in.w.c./kpa)
5.0/1.25
12.0/2.99
INLET PRESSURE-MAX (in. W.c./kPa) 14.0/3.47
10.5/2.6
14.0/3.47
Figure 2 – 8860 Minimum Fireplace Dimensions
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
11
NOTE: REMOVE FAÇADE & SURROUND FOR
COMPLETE ACCESS TO ELECTRICAL AND GAS CONNECTIONS.
DVI 44 8860 Model Overview
Proflame 2 GTMFS System
The Proflame 2 GTMFS is a modular remote control system that directs the functions of the DVI 44. The Proflame 2 GTMFS System is configured to control the on/off, main/split burner operation, its flame levels, and provides Manual and Smart thermostatic control of the hearth appliance. The system controls two remotely actuated 120V/60Hz power outlets. The Fan outlet controls the fan speed through six levels, and the Auxiliary outlet, used for the firebox light, either on or off. There is also an additional constantly powered 120V/60Hz outlet. The system has battery backup power for burner operation and control during power outages (see page 13 for specifications).
Back-up Battery Holder- On/Remote/Off Switch
The back-up battery holder is powered (6V DC) by the Control Board and uses four 1.5 volt AA type batteries for backup during power outages. The slider switch is set to one of three positions: ON (Manual Override), REMOTE (Remote Control) or OFF. The ON selection turns the valve on (to high), and activates the split flow setting last used if the Remote becomes inoperative.
Figure 4 – Proflame 2 Battery Holder
Figure 3 – Proflame 2 Remote Transmitter
Remote Transmitter
The DVI 44 comes equipped with a thermostatic remote control transmitter. The easy to read LCD display shows all functional abilities as well as a childproof lockout and low battery indicator. It displays room temperature readout, set temperature readout and function status. The remote transmitter is powered by three 1.5 volt AAA batteries. A Mode Key is provided to index between the features and a Thermostat Key is used to turn on/off or index through thermostat functions.
Figure 5 – Proflame 2 Control Board
Proflame 2 Control Board
This is the command center for the appliance. The Control Board allows the pilot to run in the Intermittent (IPI) mode or the Constant (CPI) mode. The pilot mode can be toggled between IPI and CPI via the remote control. The Control Board signals the burner to light or shut down and provides the ignitor with the electricity needed for sparking. It is the main power supply for the entire system when 120V power is available or by the batteries in the Back-up Battery Holder during a power outage.
The Control Board provides 120V power to control the fan unit through 6 speeds and turns the Accent
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
12
Light on and off via the remote control. Neither the Accent Light nor the blower will operate when 120V power is not present.
The Control Board is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from the plug.
SIT Modulating Gas Valve
The remote transmitter can modulate the valve and the flame to 6 different settings between high and off. You can modulate the flame via the remote yourself or by setting the remote control to one of the thermostatic modes. In the thermostatic mode, the stove will turn on/off based on the temperature set on the remote. In the Smart thermostatic mode, as the room temperature approaches the limit set for shut down the valve will automatically gradually step down the flame height. The reverse happens when the room cools - the valve will automatically gradually increase the flame height.
SIT Split Burner Solenoid
The remote transmitter can toggle between dual burner, and single burner mode (46,000 Btu/hr (LP) 43,000 (NG) or 16,000 Btu/hr). The burner will turn on/off.
Pilot Assembly
The pilot assembly consists of a pilot hood, sensor rod, and ignitor. The ignitor sends a spark to the pilot hood which ignites the gas and lights the pilot. With the pilot lit the sensor rod is engulfed by the flame, flame rectification occurs and the appliance remains lit. If the sensor does not stay engulfed by the flame the main burner will not light and the pilot will shut down.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
13
Figure 6 - Proflame GTMFS Component Specifications
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
14
Control Functions
Pilot Mode
Continuous Pilot (CPI): Running the DVI 44 in CPI mode will keep your pilot on even when the thermostat does not call for heat and when the burner is not lit. This is an advantage in cooler temperatures or under windy
conditions. The “standing pilot” helps to keep the venting warm and generate some draft within the system. The
standing pilot also keeps the firebox and venting warm – greatly minimizing, draft issues or condensation formation on the glass during startup. The ignitor will automatically spark whenever the pilot mode is switched to CPI, regardless of the position of the receiver switch. Hearthstone recommends the use of the CPI mode during the heating season.
Intermittent Pilot (IPI): Using the IPI mode is a more efficient use of fuel as the pilot only ignites when the thermostat calls for heat.
To switch back and forth between the two pilot modes 1) Press the OFF button on the remote 2) Press the Mode button on the remote. 3) Press Up or Down on the center pad to toggle back and forth between the two modes.
Back –up Battery Holder- On/Remote/Off Switch
The Back-up Battery Holder is normally powered by the Proflame 2 Control Board or by four 1.5V AA batteries during a power outage. This On/Remote/Off switch can be set to three different positions:
On: Manual override allowing the valve to function and ignite the burner without the remote transmitter. The ignitor will spark automatically.
Remote: Remote Transmitter controls all functions of components. Off: Turns off the stove. If CPI mode is selected, pilot will remain lit. PRG Key: Used to synchronize the Transmitter and Receiver initially, and after each battery change (see page
38).
Figure 7 - Receiver Detail