INSTRUCTIONS EXACTLY, IF NOT, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: DO NOT STORE OR USE GASOLINE OR
ANY OTHER FLAMMABLE VAPORS AND LIQUIDS
NEAR THIS OR ANY OTHER GAS APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch electrical switches; do not use the phone in
your building.
Immediately call your gas supplier from a phone outside
the structure. Follow your gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department or 911.
A qualified installer, service agency, or gas supplier must
perform installation and service of this appliance. In the
Commonwealth of Massachusetts, all installation of gas lines
and gas fittings must be performed by a licensed gas fitter or
licensed plumber.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉERIEL,
TOUTE BLESSURE OU LA MORT.
AVERTISSEMENT: NE PAS ENTRESPOSER NI
UTILISER D’ESSENCE NI D’AUTRE VAPERURS OU
LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE
CET APPRAREIL OU DE TOUT AUTRE APPAREIL.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le batiment où vous vous
trouvez.
Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service dos incendies.
L’installation et service doit être exécuté par un qualifié installer,
agence de service ou le fournisseur de gaz.
Hearthstone Quality Home Heating Products, Inc. ®
DVI-44 Model 8860
Manual: 6400-404##
R: 8/2/2012
Intentionally Blank
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
3
Serial Number:
Fuel type:
Natural Gas
Liquid Propane
Sold by:
Date of Purchase:
Address:
Phone:
E-mail
Website:
Installed by:
Date of Installation:
Address:
Phone:
E-mail
Website:
Gas Supplier:
Address:
Phone:
E-mail
Website:
Date
Who Performed Work
Work Performed
Notes:
Information Sheet
Use this page to record all relevant information concerning the purchase, installation, and maintenance of your
DVI 44 Model 8860 Direct-Vent Fireplace Insert. This information will facilitate servicing, purchase of
replacement parts, and warranty claims (if necessary). Keep your original receipt as proof of purchase.
Read this Owner’s Manual before installing, or operating your DVI 44. Retain this manual for future reference.
SERVICE RECORD
WHAT WHEN
Firebox Cleaning............. annually
Glass Cleaning................ as needed
Door Gasket.................... Replacement as needed
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
DVI 44 8860 Model Overview ................................................................................................................................... 11
Control Functions ..................................................................................................................................................... 14
Items Required for Installation .................................................................................................................................. 16
Packing List .............................................................................................................................................................. 16
Unpacking and Inspection ........................................................................................................................................ 16
CLEARANCES TO COMBUSTIBLES .............................................................................................................................. 19
Clearance to Combustibles ...................................................................................................................................... 19
VENTING INFORMATION ............................................................................................................................................. 22
ELECTRICAL SYSTEM INFORMATION .......................................................................................................................... 26
GAS SUPPLY &CONNECTIONS .................................................................................................................................. 27
Gas Connections ...................................................................................................................................................... 28
Installation of the Baffle ............................................................................................................................................ 29
Installation of the Log Set ......................................................................................................................................... 30
Completing the Installation ....................................................................................................................................... 30
Installation of the Screen .......................................................................................................................................... 31
Removal of Log Set .................................................................................................................................................. 31
ROUTINE MAINTENANCE AND CARE ........................................................................................................................... 37
As Needed: ............................................................................................................................................................... 39
REPLACEMENT PARTS &ACCESSORIES LIST ............................................................................................................. 40
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
5
Introduction
Congratulations on your purchase of the DVI 44
Model 8860, Gas-Fired Direct-Vent Insert. The DVI
44, by Hearthstone, incorporates the latest in direct
vent gas technology, which will provide you with
ease of use, clean, and efficient heat for years to
come. The DVI 44’s copious glass, sleek styling, and
enameled or painted façade options gives the DVI
44 ambiance and a pleasing look that enhances any
room.
However, as with any gas appliance, the unit must
be properly and safely installed and maintained by
qualified service personnel to ensure safe and
trouble-free operation.
DVI 44 Model 8860 features:
1. The most realistic looking gas fire available
today with highly detailed logs.
2. Heat Wave® refractory firebox liner to reflect the
heat into your room in the most efficient way
possible.
3. Real Platinum glowing embers, for instant glow
and realism.
4. Child safety screen to reduce the risk of severe
burns on the front glass.
5. Smart thermostatic remote control with split
burner technology for a full range of heat output.
6. Integral, quiet, and efficient room air circulating
fan – standard.
7. Battery backup to maintain basic functionality
during power outages (up to a week on fresh
batteries).
The Proflame System Features:
1. Thermostatic Remote Control
a. Twelve (12) flame levels, adjustable via
the remote
b. Split Burner control via remote
c. Six (6) blower speeds, adjustable via the
remote
d. Thermostatic mode to turn on/off based
upon room temperature.
2. The option to toggle back and forth between an
3. “Child-safe” lock-out on remote control.
4. “Low Battery” indicator for Transmitter on remote
Operate and maintain this gas heater according to
the instructions in this manual. For your safety, and
years of trouble free operation, read this manual in
its entirety.
Verify the gas connections and that venting systems
supply adequate combustion and ventilation air to
meet the requirements of local, regional or national
installation codes. Qualified service personnel must
inspect the gas heater before use, and at least
annually.
Manufactured & warranted by:
Hearthstone Quality Home heating Products, Inc.
317 Stafford Ave.
Morrisville, VT 05661
flame levels automatically as the unit
approaches the set point temperature.
f. Firebox Accent Light controlled by the
remote.
Intermittent (IPI) or Continuous (CPI) pilot mode
via the remote.
a. The IPI (Summer) mode allows the most
efficient use of gas, burning the pilot
only when the thermostat calls for the
burner to ignite.
b. The CPI (Winter) mode runs the pilot
continuously keeping the firebox warmer
thus promoting better draft in colder
weather.
control
Read this Owner’s Manual
Insert Must Be Installed and Maintained By
Qualified Service Personnel
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
6
Safety & Good Practices
Your DVI 44 is an attractive and extremely efficient
and easy to use heater, utilizing today’s best
technologies. By following a few simple safety
precautions and by performing minimal
maintenance, the unit will remain appealing while
providing years of quality performance.
The installation must conform to local codes or, in
the absences of local codes, the current National
Fuel Gas Code, ANSI Z223.1 (NFPA 54) or
CAN/CGA B149 Installation Code. (Installer
l’appareil selon les codes ou réglements locaux, ou,
en l’absence de tells réglements, selon les Codes
d’installation CAN/CGA B149.)
CAUTION: DO NOT USE THIS APPLIANCE IF ANY
PART WAS UNDER WATER. IMMEDIATELY CALL
A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE HEATER AND TO REPLACE ANY PART OF
THE CONTROL SYSTEM AND GAS CONTROL
THAT HAS BEEN UNDER WATER. (NE PAS SE
SERVIR DE CET APPAREIL S’IL A ÉTÉ PLONGÉ
DANS L’EAU, COMPLÉTEMENT OU EN PARTIE.
APPELER UN TECHNICIEN QUALIFIÉ POUR
INSPECTOR L’APPAREIL ET REMPLACER TOUTE
PARTIE DU SYSTÉME DE CONTRÔLE ET TOUTE
COMMANDE QUI ONT ÉTÉ PLUNGES DANS
L’LAU.)
During the first few hours of operation the appliance
may produce smoke and/or odor. This is normal
during the first several burns and also after long
periods when the stove is not burned. During these
initial burns, open a window(s) to assist in the
removal of the smoke/odor.
The appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of ½ psig. (3.5k Pa). The
appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than ½ psig (3.5k Pa).
Fire Hazard
Do not store or use gasoline, other flammable
vapors or liquids in the vicinity of this appliance.
Locate the DVI 44 out of traffic areas and away from
furniture, draperies, clothing, and flammable
material.
Vent Only to the Outside
Never vent the gas heater to other rooms or
buildings.
Service Caution
If you believe your DVI 44 is not in any way
performing properly, immediately discontinue
operation until the unit is inspected and approved by
qualified service personnel. Prior to servicing the
unit, turn the gas to the valve off, and disconnect
any electrical source. Ensure the unit is cool prior to
servicing and cleaning. Replace any safety screen,
guard, or component removed during servicing
prior to operation. (Tout écran ou protecteur retiré
pour permettre l’entretien de l’appareil doit être remis
en place avant de mettre l’appareil en marche.) Use of
any components not supplied by Hearthstone on the
stove voids all warranties. Do not substitute
components.
Proper Fuel
This gas heater is designed to burn natural gas (NG)
or with conversion, liquid propane (LP). Never burn
any fuel gas not intended for use with this unit.
Never burn paper, wood, or other materials in this
appliance.
This heater is factory equipped to burn natural gas
(NG). To burn propane (LP), you must purchase an
LP conversion kit 98-56601.
This appliance is only for use with the type(s) of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
certified kit is used. Cet appareil doit être atilisé
uniquement avec les types de gas indiqués sur la
plaque signalétique. Ne pas l’utiliser avec d’autres
gas sauf si un kited conversion certifié est installé. )
WARNING: THIS GAS APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERVING A
SEPARATE GAS OR SOLID-FUEL BURNING
APPLIANCE
WARNING: DO NOT OPERATE THE APPLIANCE
WITH THE FRONT GLASS REMOVED, CRACKED,
OR BROKEN. REPLACEMENT OF GLASS
SHOULD BE DONE BY A LICENSED OR
QUALIFIED SERVICE PERSON. ONLY OPEN
FRONT FOR ROUTINE SERVICE. DO NOT SLAM
FRONT OR STRIKE GLASS. AVERTISSEMENT. NE
PAS UTILISER L’APPAREIL SI LE PANNEAU
FRONTAL EN VERRE N’EST PAS EN PLACE, EST
CRAQUÉ OU BRISÉ. CONFIEZ LE
REMPLACEMENT DU PANNEAU À UN
TECHNICIEN AGRÉÉ.
WARNING: HEARTHSTONE RECOMMENDS THAT
ONLY AN NFI CERTIFIED SERVICE TECHNICIAN
INSTALLS, AND REPAIRS THIS APPLIANCE. A
QUALIFIED SERVICE TECHNICIAN MUST
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
7
INSPECT THE APPLIANCE BEFORE USE, AND AT
LEAST ANNUALLY. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIAL, PETS,
ETC. IT IS IMPERATIVE THAT THE CONTROL
COMPARTMENTS, BURNERS, AND CIRCULATING
AIR PASSAGES OF THE APPLIANCE ARE KEPT
CLEAN AND FREE OF OBSTRUCTIONS.
(L’INSTALLATION ET LA RÉPARATION DEVRAIT
ÊTRE CONFIÉES À UN TECHNICIEN QUALIFIÉ.
L’APPAREIL DEVRAIT FAIRE L’OBJET D’UNE
INSPECTION PAR UN TECHNICIEN
PROFESSIONNEL AVANT D’ÊTRE UTILISÉ ET AU MOINS UNE FOIS L’AN PAR LA SUITE. DES
NETTOYAGES PLUS FRÉQUENTS PEUVENT
ÊTRE NÉCESSAIRES SI LES TAPIS, LA LITERIE,
ET CETERA PRODUISENT UNE QUANTITÉ
IMPORTANTE DE POUSSIÈRE. IL EST ESSENTIEL
QUE LES COMPARTIMENTS ABRITANT LES
COMMANDES, LES BRÛLEURS ET LES
CONDUITS DE CIRCULATION D’AIR DE
L’APPAREIL SOIENT TENUS PROPRES)
Hot Surfaces
Certain exposed surfaces of the DVI 44 will reach
high temperatures during normal operation.
Clearances to combustibles must be maintained, as
specified in the “Clearances To Combustibles”
section of this manual.
DUE TO HIGH TEMPERATURES THE APPLIANCE
SHOULD BE LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE, DRAPERIES,
CLOTHING AND FLAMMABLE MATERIALS. (EN
RAISON DES TEMPÉRATURES ÉLEVÉES,
L’APPAREIL DEVRAIT ÊTRE INSTALLÉ DANS UN
ENDROIT OÙ IL Y A PEU DE CIRCULATION ET
LOIN DU MOBILIER ET DES TENTURES.)
CHILDREN AND ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH SURFACE
TEMPERATURES AND SHOULD STAY AWAY TO
AVOID BURNS TO SKIN OR CLOTHING IGNITION.
(LES ENFANTS ET LES ADULTES DEVRAIENT
ÊTRE INFORMÉS DES DANGERS QUE POSENT
LES TEMPÉRATURES DE SURFACE ÉLEVÉES ET
SE TENIR À DISTANCE AFIN D’ÉVITER DES
BRÛLURES OU QUE LEURS VÊTEMENTS NE
S’ENFLAMMENT.)
CAREFULLY SUPERVISE YOUNG CHILDREN
WHEN THEY ARE IN THE SAME ROOM AS THE
APPLIANCE. TODDLERS, YOUNG CHILDREN,
AND OTHERS MAY BE SUSCEPTIBLE TO
ACCIDENTAL CONTACT BURNS. A PHYSICAL
BARRIER IS RECOMMENDED IF THERE ARE AT
RISK INDIVIDUALS IN THE HOUSE. TO RESTRICT
ACCESS TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO KEEP
TODDLERS, YOUNG CHILDREN, AND OTHER AT
RISK INDIVIDUALS OUT OF THE ROOM AND
AWAY FROM HOT SURFACES. (LES JEUNES
ENFANTS DEVRAIENT ÊTRE SURVEILLÉS
ÉTROITEMENT LORSQU’ILS SE TROUVENT
DANS LA MÊME PIÈCE QUE L’APPAREIL. LES
TOUT PETITS, LES JEUNES ENFANTS OU LES
ADULTES PEUVENT SUBIR DES BRÛLURES
S’ILS VIENNENT EN CONTACT AVEC LA
SURFACE CHAUDE. IL EST RECOMMANDÉ
D’INSTALLER UNE BARRIÈRE PHYSIQUE SI DES
PERSONNES À RISQUES HABITENT LA MAISON.
POUR EMPÊCHER L’ACCÈS À UN FOYER OU À
UN POÊLE, INSTALLEZ UNE BARRIÈRE DE
SÉCURITÉ; CETTE MESURE EMPÊCHERA LES
TOUT PETITS, LES JEUNES ENFANTS ET TOUTE
AUTRE PERSONNE À RISQUE D’AVOIR ACCÈS À
LA PIÈCE ET AUX SURFACES CHAUDES.)
CLOTHING OR OTHER FLAMMABLE MATERIAL
SHOULD NOT BE PLACED ON OR NEAR THE
APPLIANCE. (ON NE DEVRAIT PAS PLACER DE
VÊTEMENTS NI D’AUTRES MATIÈRES
INFLAMMABLES SUR L’APPAREIL NI À
PROXIMITÉ.)
CLEAN THE AREA AROUND, UNDER, AND
BEHIND THE UNIT ON A REGULAR BASIS TO
PREVENT THE ACCUMULATION OF DUST AND
LINT.
Ceramic Logs, & Burner
If the decorative ceramic log, or burner material
supplied with the DVI 44 are damaged or parts are
missing, they must be replaced with the same, or
approved Hearthstone replacement parts. These
components affect the combustion quality and safety
of the heater. Do not replace ceramic logs, or the
burner with unapproved ceramic components or any
other material.
We recommend you always wear gloves and safety
goggles while handling the ceramic log set, and
burner materials.
Electrical Hazard
Any three-prong grounded plug must be plugged
directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding
prong from any plug or otherwise attempt to
circumvent the grounding protection provided with
the unit. The DVI 44 must be electrically grounded in
accordance with local codes, or in the absence of
local codes, with the National Electrical Code,
ANSI.NFPA 70 in the U.S. or CSA C22.1 Canadian
Electrical Code in Canada.
Do Not Light Pilot or Burner by Hand
The pilot light on this gas heater is lit using an
electronic ignition module as described elsewhere in
this manual. Never attempt to light the pilot or main
burner by hand with a match or lighter.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
8
Mobile Home Installations
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home
(USA only), where not prohibited by local codes.
(Cet appareil peut être installé dans un maison
préfabriquée (mobile) déjá installée á demeure si les
réglements locaux le permettent.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
9
Specifications
LISTED:Gas-Fired Direct-Vent Fireplace Heater
Model: DVI 44 Direct-Vent Gas Fireplace
Insert (8860)
Testing Agency: Intertek Testing Services
NA, Inc. (ITS)
Tested to: ANSI Z21.88-09, CSA 2.33-09,
CAN/CGA2.17-M91
Certified for Canada, CSA P.4.1-02
Approved for Mobile Home Installation (see
page 8)
Certified for use by:
Board of State Examiners of Plumbers & Gasfitters
100 Cambridge Street, Room 1511
Boston, MA 02202
www.mass.gov
Figure 1 - Model 8860 Dimensions (Inches)
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
10
Specification
NG
LP
INPUT RATING (Btu/hr) (0-610 m)
43,000
46,000
MAXIMUM OUTPUT (Btu/hr) (0-610 m)
28,478
31,496
MINIMUM INPUT (Btu/hr) (0-610m)
15,000
17,000
HIGH ALTITUDE RATING (Btu/hr) 610-1370 m
36,000
37,000
ORIFICE SIZE (DMS) 0-610 m (front/rear))
46F/38R
55F/53R
MANIFOLD PRESSURE - (in. W.c./kpa)
3.5/0.87
10.0/2.48
MANIFOLD PRESSURE - Low setting (in. W.c./kpa)
1.6/0.40
6.4/1.59
INLET PRESSURE - MINIMUM (in.w.c./kpa)
5.0/1.25
12.0/2.99
INLET PRESSURE-MAX (in. W.c./kPa) 14.0/3.47
10.5/2.6
14.0/3.47
Figure 2 – 8860 Minimum Fireplace Dimensions
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
11
NOTE: REMOVE FAÇADE & SURROUND FOR
COMPLETE ACCESS TO ELECTRICAL AND GAS
CONNECTIONS.
DVI 44 8860 Model Overview
Proflame 2 GTMFS System
The Proflame 2 GTMFS is a modular remote control
system that directs the functions of the DVI 44. The
Proflame 2 GTMFS System is configured to control
the on/off, main/split burner operation, its flame
levels, and provides Manual and Smart thermostatic
control of the hearth appliance. The system controls
two remotely actuated 120V/60Hz power outlets. The
Fan outlet controls the fan speed through six levels,
and the Auxiliary outlet, used for the firebox light,
either on or off. There is also an additional constantly
powered 120V/60Hz outlet. The system has battery
backup power for burner operation and control during
power outages (see page 13 for specifications).
Back-up Battery Holder- On/Remote/Off
Switch
The back-up battery holder is powered (6V DC) by
the Control Board and uses four 1.5 volt AA type
batteries for backup during power outages. The slider
switch is set to one of three positions: ON (Manual
Override), REMOTE (Remote Control) or OFF. The
ON selection turns the valve on (to high), and
activates the split flow setting last used if the Remote
becomes inoperative.
Figure 4 – Proflame 2 Battery Holder
Figure 3 – Proflame 2 Remote Transmitter
Remote Transmitter
The DVI 44 comes equipped with a thermostatic
remote control transmitter. The easy to read LCD
display shows all functional abilities as well as a
childproof lockout and low battery indicator. It
displays room temperature readout, set temperature
readout and function status. The remote transmitter is
powered by three 1.5 volt AAA batteries. A Mode Key
is provided to index between the features and a
Thermostat Key is used to turn on/off or index
through thermostat functions.
Figure 5 – Proflame 2 Control Board
Proflame 2 Control Board
This is the command center for the appliance. The
Control Board allows the pilot to run in the
Intermittent (IPI) mode or the Constant (CPI) mode.
The pilot mode can be toggled between IPI and CPI
via the remote control. The Control Board signals the
burner to light or shut down and provides the ignitor
with the electricity needed for sparking. It is the main
power supply for the entire system when 120V power
is available or by the batteries in the Back-up Battery
Holder during a power outage.
The Control Board provides 120V power to control
the fan unit through 6 speeds and turns the Accent
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
12
Light on and off via the remote control. Neither the
Accent Light nor the blower will operate when 120V
power is not present.
The Control Board is equipped with a three-prong
(grounding) plug for protection against shock hazard
and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or
remove the grounding prong from the plug.
SIT Modulating Gas Valve
The remote transmitter can modulate the valve and
the flame to 6 different settings between high and off.
You can modulate the flame via the remote yourself
or by setting the remote control to one of the
thermostatic modes. In the thermostatic mode, the
stove will turn on/off based on the temperature set on
the remote. In the Smart thermostatic mode, as the
room temperature approaches the limit set for shut
down the valve will automatically gradually step down
the flame height. The reverse happens when the
room cools - the valve will automatically gradually
increase the flame height.
SIT Split Burner Solenoid
The remote transmitter can toggle between dual
burner, and single burner mode (46,000 Btu/hr (LP)
43,000 (NG) or 16,000 Btu/hr). The burner will turn
on/off.
Pilot Assembly
The pilot assembly consists of a pilot hood, sensor
rod, and ignitor. The ignitor sends a spark to the pilot
hood which ignites the gas and lights the pilot. With
the pilot lit the sensor rod is engulfed by the flame,
flame rectification occurs and the appliance remains
lit. If the sensor does not stay engulfed by the flame
the main burner will not light and the pilot will shut
down.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
14
Control Functions
Pilot Mode
Continuous Pilot (CPI): Running the DVI 44 in CPI mode will keep your pilot on even when the thermostat
does not call for heat and when the burner is not lit. This is an advantage in cooler temperatures or under windy
conditions. The “standing pilot” helps to keep the venting warm and generate some draft within the system. The
standing pilot also keeps the firebox and venting warm – greatly minimizing, draft issues or condensation
formation on the glass during startup. The ignitor will automatically spark whenever the pilot mode is switched to
CPI, regardless of the position of the receiver switch. Hearthstone recommends the use of the CPI mode during
the heating season.
Intermittent Pilot (IPI): Using the IPI mode is a more efficient use of fuel as the pilot only ignites when the
thermostat calls for heat.
To switch back and forth between the two pilot modes 1) Press the OFF button on the remote 2) Press the
Mode button on the remote. 3) Press Up or Down on the center pad to toggle back and forth between the two
modes.
Back –up Battery Holder- On/Remote/Off Switch
The Back-up Battery Holder is normally powered by the Proflame 2 Control Board or by four 1.5V AA batteries
during a power outage. This On/Remote/Off switch can be set to three different positions:
On: Manual override allowing the valve to function and ignite the burner without the remote transmitter. The
ignitor will spark automatically.
Remote: Remote Transmitter controls all functions of components.
Off: Turns off the stove. If CPI mode is selected, pilot will remain lit.
PRG Key: Used to synchronize the Transmitter and Receiver initially, and after each battery change (see page
38).
Figure 7 - Receiver Detail
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.