HearthStone BI-48-ST, BI-48-SSR, BI-60-SSL, BI-60-SSR, BI-72-SSL Owner's Manual

...
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.  Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.  Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department or 911.
A qualified installer, service agency, or gas supplier must
perform installation and service of this appliance. In the Commonwealth of Massachusetts, all installation of gas lines and gas fittings must be performed by a licensed gas fitter or licensed plumber.
Ce manual est disponible en Francais a
www.hearthstonetech.com
Report #0361GF006S
WARNING: This product can expose you to chemicals including glass wool fiber and carbon monoxide which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
California Prop 65
CELESTE/GEMINI 48/60/72
Series 8930, 8935, 8940, 8945, 8950, and 8955
BUILT-IN DIRECE VENT GAS FIREPLACES
BI-48-SSR, BI-60-SSL, BI-60-SSR, BI-72-SSL, BI-72-SSR
Owner's Manual
Installation & Operating
Instructions
Read This Manual in Its Entirety
Operate and Maintain This Gas Heater
According to This Instruction Manual.
SAVE THESE INSTRUCTIONS
Hearthstone Quality Home Heating Products, Inc. ®
CELESTE/GEMINI 8930/8935/8940/8945/8950/8955
Manual: 6400-40404
R: 08/30/18
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
INDEX
IMPORTANT SAFETY INFORMATION.................................................................... 4
MODEL LIST.............................................................................................................. 6
SPECIFICATIONS...................................................................................................... 8
CLEARANCES........................................................................................................... 10
INSTALLATION INFORMATION................................................................................ 13
VENTING.................................................................................................................... 15
FINAL ASSEMBLY..................................................................................................... 21
LIGHTING & OPERATION......................................................................................... 24
GAS CONVERSION................................................................................................... 33
MAINTENANCE LOG FORMS...................................................................................37
INSTALLATION RECORD..........................................................................................38
CONTROL SYSTEM SCHEMATIC............................................................................ 40
TROUBLESHOOTING................................................................................................ 41
WARRANTY INFORMATION..................................................................................... 43
WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BEGININNG THE INSTALLATION OF THE CELESTE AND GEMINI PRODUCT LINES. ALTHOUGH THE BASIC REQUIREMENTS FOR THE INSTALLATION OF ALL DIRECT VENT GAS FIREPLACES ARE SIMILAR, EACH SPECIFIC PRODUCT HAS ITS OWN UNIQUE SET-UP AND INSTALLATION REQUIREMENTS THAT MUST BE FOLLOWED EXACTLY. PLAN YOUR INSTALLATION IN ADVANCE BY CAREFULLY REVIEWING ALL THE INFORMATION CONTAINED IN THIS MANUAL.
2
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
POÊLE AU GAZ À VENTILATION DIRECTE
Manuel de l'Utilisateur
Lire ce Manuel en Entier
Utiliser et Entretenir ce Poêle au Gaz
selon ce Manuel d'Instructions
CONSERVER CES INSTRUCTIONS!
Ne pas entreposer ni utiliser d’essence ni d’autre
vaperurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareil. Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans le batiment où vous vous trouvez.
Quittez le bâtiment immédiatement. Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
3
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
IMPORTANT SAFETY INFORMATION
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/BCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
The installation must provide for adequate ventilation air to the appliance. This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. The appliance, when installed, must be electrically grounded in accordance with local codes, or, in the absence
of local codes, with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22. 1. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable
vapors and liquids. The flow of combustion and ventilation air must not be obstructed. Adequate accessibility clearances must be
maintained for servicing and proper operation of this appliance. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
Clothing or other flammable material should not be placed on or near the appliance. Any screen or guard removed for servicing an appliance must be replaced prior to operating the
appliance.
4
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments, burners and circulating air passageways of the appliance be kept clean.
WARNING: Do not operate the appliance with the glass door assembly removed, or if the glass is cracked or broken. Replacement of the glass should be done by a qualified service person.
WARNING: Use only glass assembly, P/N 48-510 which includes the glass panel, frame and gasket. Do not use substitute materials. Do not strike or slam the glass front. Do not use abrasive cleaners. Do not clean when hot.
CAUTION: DO NOT OPERATE WITH BROKEN GLASS
Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passageways of the appliance be kept clean.
Note:
Periodically conduct a visual check to ensure the pilot and burner flames are as shown (right).
Vent Installation Note:
When the first piece of direct vent pipe is attached to the starter collar of the fireplace, be sure to inspect both the inside and outside joints to ensure a secure fit with no air gaps. Once it is confirmed there are no gaps, rotate the pipe clockwise to lock it in place.
Follow the vent manufacture’s
installation instructions during vent pipe installation.
5
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
CELESTE 48 – SINGLE SIDE FIREPLACE
Right side vent exit Model# 8935-0000R
CELESTE 48 – SINGLE SIDE FIREPLACE
Left side vent exit Model# 8935-0000L
GEMINI 48 – SEE-THRU FIREPLACE
Model# 8930-0000
CELESTE 60 – SINGLE SIDE FIREPLACE
Right side vent exit Model# 8945-0000R
CELESTE 60 – SINGLE SIDE FIREPLACE
Left side vent exit Model# 8945-0000L
GEMINI 60 – SEE-THRU FIREPLACE
Model# 8940-0000
CELESTE 72 – SINGLE SIDE FIREPLACE
Right side vent exit Model# 8955-0000R
CELESTE 72 – SINGLE SIDE FIREPLACE
Left side vent exit Model# 8955-0000L
GEMINI 72 – SEE-THRU FIREPLACE
Model# 8950-0000
6
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
CERTIFICATION
This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2014/CSA 2.33-2014 Vented Gas Fireplace Heaters and CAN/CGA-2.17-M91 (R2014), Gas-Fired Appliances for Use At High Altitudes.
This AURORA Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations.
These appliances are approved for installation in the Commonwealth of Massachusetts by the Board of State Examiners of Plumbers and Gas Fitters.
Sample Rating Label (affixed to control panel within firebox)
7
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
NATURAL GAS SPECIFICATION CHART
INPUT
CELESTE/GEMINI 48
CELESTE/GEMINI 60
CELESTE/GEMINI 72
Input Rating BTU/Hr.
26,000
30,000
34,000
Min. Input BTU/Hr.
16,000
21,000
27,000
Orifice Size - DMS
#42
#49
#46
GAS SUPPLY
CELESTE/GEMINI 48
CELESTE/GEMINI 60
CELESTE/GEMINI 72
Manifold Pressure
3.5” w.c. / 0.9kPa
3.5” w.c. / 0.9kPa
3.5” w.c. / 0.9kPa
Min. Supply Pressure
5.5” w.c. / 1.4kPa
5.5” w.c. / 1.4kPa
5.5” w.c. / 1.4kPa
Max. Supply Pressure
10.0” w.c. / 2.5kPa
10.0” w.c. / 2.5kPa
10.0” w.c. / 2.5kPa
PROPANE (LP) SPECIFICATION CHART
INPUT
CELESTE/GEMINI 48
CELESTE/GEMINI 60
CELESTE/GEMINI 72
Input Rating BTU/Hr.
30,000
34,000
40,000
Min. Input BTU/Hr.
19,000
25,000
28,000
Orifice Size – DMS
#52
#56
#55
GAS SUPPLY
CELESTE/GEMINI 48
CELESTE/GEMINI 60
CELESTE/GEMINI 72
Manifold Pressure
10.0” w.c. / 2.5kPa
10.0” w.c. / 2.5kPa
10.0” w.c. / 2.5kPa
Min. Supply Pressure
11.0” w.c. / 2.8kPa
11.0” w.c. / 2.8kPa
11.0” w.c. / 2.8kPa
Max. Supply Pressure
13.0” w.c. / 3.3kPa
13.0” w.c. / 3.3kPa
13.0” w.c. / 3.3kPa
Efficiency NG/LP
CEL/GEM 48
CEL/GEM 60
CEL/GEM 72
*Typical Installation, Steady State Efficiency - %
62.2/68.4
69/73.9
72.6/76.4
Steady State Efficiency - %
61/63.4
64.8/70.8
70.4/74.8
Annual Fuel Utilization Efficiency (AFUE) - %
59/61.4
62.8/68.6
68.2/72.5
Canadian p.4 Efficiency - %
65.7/62
64.5/67.7
69.8/72.7
SPECIFICATIONS
*Your efficiency will increase with the length of the vent run. The typical installation tested is 5ft vertical and 5ft horizontal.
NOTE: The maximum achievable steady state efficiency can vary depending on how the fireplace is installed and operated.
It is recommended that the pilot flame be turned off if the appliance will not be in use for an extended
period of time.
This appliance is equipped for use with the fuel type indicated on the rating plate. Field conversion is
only permitted with a conversion kit supplied by Hearthstone.
8
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
SPECIFICATIONS
*The Horizontal and Vertical vent centerline dimensions’ account for the use of a 45-degree elbow.
The gas fireplace is shipped with a 3/8” tube OD (female) connection. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve. The stove and its main
control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The stove must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or greater than 1/2 psi (3.5 kPa). After the gas supply has been connected, use a commercial gas leak detector or apply a soapy water solution to all the fittings to check for gas leaks. Never use a flame to test for leaks.
9
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
GEMINI/CELESTE 48
GEMINI/CELESTE 60
GEMINI/CELESTE 72
Sides
4” (102mm)
4” (102mm)
4” (102mm)
Floor
1/2” (13mm)
1/2” (13mm)
1/2” (13mm)
Back (Single Sided)
2” (51mm)
2” (51mm)
2” (51mm)
Back (See-Thru)
12” (305mm)
12” (305mm)
12” (305mm)
Front
12” (305mm)
12” (305mm)
12” (305mm)
Clearance around vent pipe
1.5” (38mm)
1.5” (38mm)
1.5” (38mm)
CLEARANCES
The image above shows a typical installation.
All framing, finishing, and construction materials that fall within 4” (102mm) of either the sides or top of
the fireplace must be non-combustible and ½” below the unit.
Any materials that cover the front face or rear face of the fireplace must be non-combustible. Allow
clearance for removal of fireplace trim, screen, and glass.
The fireplace must be secured to the framing studs using the nailing flanges as shown above. Use 2
screws or nails per nailing flange to secure the fireplace.
The sheet metal face of this fireplace must be covered by a non-combustible material, it may not be left
exposed.
The floor the fireplace immediately rests on must be constructed of non-combustible material with an R
factor of at least .37, with a minimum thickness of ½” (13mm).
10
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
FRAMING BEFORE INSTALLATION
Sometimes it is necessary to frame the location you will be installing the fireplace before the fireplace is onsite, the above image shows an example of how to frame the wall before the fireplace is moved into position.
All framing, finishing, and construction materials that fall within 4” (102mm) of either the sides or top of
the fireplace must be non-combustible. (shown with a dashed line in the image above)
Note that the vent starter collar sits slightly above the top surface of the fireplace can, there must be
clearance to allow the fireplace with starter collar to slide into place.
The floor the fireplace immediately rests on must be constructed of non-combustible material with an R
factor of at least .37, with a minimum thickness of ½” (13mm).
This framing guide is just an example of the many ways in which a AURORA Fireplace can be installed.
You may need to customize this framing design to allow for things such as doors, windows, countertops, structural frame members or local code requirements.
Dimension “B” for your model can be found on page .
11
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
Room Volume for Vent Free
WARNING Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly
can create a fire hazard.
The combustible area above the facing must not protrude more than ¾ (19mm) from the facing; if it
does, it is considered a mantel and must meet the mantel requirements on the following page.
When selecting non-combustible materials for use in the installation, take note of the material’s
propensity to absorb and conduct heat. Materials such as metal, stone, and ceramics may transmit heat more readily than other building materials.
Only non-combustible materials (i.e. brick, tile, slate, steel, or other man made materials with a UL fire
rating of Zero) may be used in the construction and installation of this fireplace. Any material must be fastened to surrounding framing. NOT to the face of the fireplace.
ATTENTION: Before proceeding with your installation, determine if you plan to use either the Power Vent kit (99-
65350 horizontal or 99-653352 vertical) or the Heat Redistribution Kit (99-57350). Read the manual for these optional components before proceeding with your installation, as your installation requirements and procedure may change.
12
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
INSTALLATION INFORMATION
WARNING Read all instructions completely and thoroughly before attempting installation. Failure to do so could
result in serious injury, property damage, or loss of life. Operation of improperly installed or maintained venting system could result in serious injury, property damage, or loss of life.
NOTE: Any electrical wiring, gas plumbing, or vent installation required by the appliance must be done prior to final finishing. The unit shall be test burned on high for at least 30 minutes prior to final finishing to confirm proper operation. Failure to test the appliance before final finishing may require significant and costly reconstruction
INSTALLATION PRECAUTIONS:
Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing the vent kit, the installer must read this fireplace manual and vent kit instructions. Only a qualified, licensed, installer/service person shall install the venting system. The installer must follow the following safety rules:
Wear gloves and safety glasses for protection.  Use extreme caution when using ladders or when on rooftops.  Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your fireplace:
Installation of any damaged venting component.  Unauthorized modification of the venting system.  Installation of any component part not manufactured or approved by Hearthstone.  Installation other than permitted by these instructions.
NOTICE: Failure to follow these instructions will void the warranty.
13
Hearthstone Quality Home Heating Products, Inc CELESTE/GEMINI 48/60/72 Models 8930/8935/8940/8945/8950/8955
State of Massachusetts: The installation must be completed by a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS This product must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts. If this appliance is installed in a dwelling, building or structure used in whole or in part for residential purposes and the installation includes a horizontal vent termination that is less than seven (7) feet above the finished grade in the area of the venting, including but not limited to decks and porches, a hard-wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level of the dwelling, building or structure where the appliance is to be installed.
Additionally, a hard-wired or battery operated carbon monoxide detector with an alarm must be in­stalled on each additional level of the dwelling, building or structure served by the appliance. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors.
In the event that the horizontally vented appliance is installed in a crawl space or attic, the hard­wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
In the event that this requirement cannot be met at the time of completion of the installation of the appliance, the owner shall have a period of thirty (30) days to comply with the requirement. However, during said thirty (30) day period, a battery operated carbon monoxide detector with alarm must be installed.
Each carbon monoxide detector as required in accordance with the above provisions must comply with NFPA 720 and be ANSI/UL 2034 and IAS certified.
In addition, when the vent termination is less than seven (7) feet above finished grade a metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH IN-CLUDE PARTS LISTS, AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT THE COMPLETION OF THE INSTALLATION.
ATTENTION INSTALLERS: Mark below which venting system was used in the installation. These instructions must remain with the AURORA Gas Fireplace Installation & Operation Manual.
O Simpson DuraVent GS/PRO® O Selkirk Direct-Temp® O Security Secure Vent™ O AmeriVent Direct™ O Metal Fab Direct Vent O ICC Direct Vent
14