• Important operating
and maintenance
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency , or the
gas supplier.
• Read, understand and follow
these instructions for safe
installation and operation.
DO NOT
DISCARD
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/081
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
Page 2
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
Congratulations
Congratulations on selecting a Heat & Glo gas appliance
—an elegant and clean alternative to wood burning
appliances. The Heat & Glo gas appliance you have
selected is designed to provide the utmost in safety,
reliability, and effi ciency.
As the owner of a new appliance, you’ll want to read and
carefully follow all of the instructions contained in this
Owner’s Manual. Pay special attention to all Cautions and
Warnings.
Homeowner Reference Information
This Owner’s Manual should be retained for future
reference. We suggest that you keep it with your other
important documents and product manuals.
The information contained in this Owner’s Manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Heat & Glo gas appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of appliance products!
We recommend that you record the following pertinent
information about your appliance.
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on appliance: ____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Listing Label Information/Location
Test Lab & Report No.
Tested and
Listed by
OMNI-Test Laboratories, Inc.
Report No. / Rapport Numero
FAN TYPE VENTED CIRCULATOR Blower Electrical Rating115 V., 1.5 Amps, 60 Hz, 150 Watts
APPROVED FOR CANADA AND USA TO:
ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heater, and applicable sections of UL307b Gas Burning
Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CG A 2.17-M91 “Gas Fired Appliances
for use at High Altitudes.”
This appliance is manufactured for operation with Natural Gas. For conversion to propane the Manufacturer’s kit
provided with the stove must be used in conjuntion with the instructions in the owner's manual.
This vented gas fireplace heater is not for use with air filters.
This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is
required.
Input Rate on “HI” (BTU/Hr)30,00028,000
Input Rate on “LO” (BTU/Hr)22,50022,650
Main Burner Orifice (DMS)3652
Minimum Inlet Pressure (Inches W.C.)4.5”11”
Maximum Inlet Pressure (Inches W.C.)7.0”14”
Manifold Pressure on “HI” (Inches W.C.)3.5”10”
Efficiency up to82.5%81%
AFUE71%72.5%
This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for
Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for
information on making these changes.
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if
none, follow The National Fuel Gas Code,ANSI Z223.1 and NFPA54; or Canadian Installation Codes CAN/CGA-B149.
NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or
licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed
plumber or gas fitter.)
The model information regarding your specifi c appliance can be found on
the rating plate usually located in the control area of the appliance.
SERIAL
Beaverton
Oregon USA
C
061-S-63-5
SAMPLE
MINIMUM CLEARANCES TO COMBUSTIBLES
007
NO.
MODEL: PALOMA
VENTED GAS
NOT FOR USE WITH SOLID FUE
P.4.1-02 Canada Minimum Pipe 69% NG / 71% LP
For use with Natural GasFor use with Propane
APPLIANCE
L
"0-2000’"0-2000’
Adivision of Hearth & Home Technologies
20802 Kensington Blvd, Lakeville, MN 55044
www.heatnglo.com
Serial No.
Model Name
Manufactured by:
2005 2006 2007Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecJan
D. Loss of Power and Battery Backup Usage . . . . . . . . . . . . 31
E. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 32
= Contains updated information.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/083
Page 4
1
1
Listing and Code Approvals
A. Appliance Certifi cation
MODELS: Paloma
LABORATORY: Omni Test Laboratories, Inc.
TYPE: Vented Gas Fireplace Heater
STANDARD: ANSI Z21.88B-2003 • CSA 2.33-2003 • UL307B
CAN/CBA 2.17-M91
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
NOT INTENDED FOR USE AS A PRIMAR Y HEAT SOURCE.
This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Manufactured Home or Mobile Home installation may
occur only after the home is site located and must conform
with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured
Home Installations, ANSI/NCSBCS A225.1, or Standard
for Gas Equipped Recreational Vehicles and Mobile
Housing, CSA Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70,
or the Canadian Electrical Code, CSA C22.1.
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass
behind the curved glass. Replace glass only with 5 mm
ceramic glass. Please contact your dealer for replacement glass.
Note: This installation must conform with local codes. In the
absence of local c odes you must comply w ith the National
Fuel Gas Code, ANSI Z223.1 -latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
C. BTU Specifi cations
Model
(US or Canada)
Paloma (NG)30,00022,5003682.569
Paloma (LP)28,00022,650528171
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Orifi ce
Size
(DMS)
*Steady
State
Effi ciency %
**P.4
%
D. High Altitude Installations
Omni-Test Laboratories, Inc. listed gas appliances are
tested and approved without requiring changes for
elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500
feet in Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating
by changing the existing burner orifi ce to a smaller size.
Input rate should be reduced by 4% for each 1000 feet
above a 2000 foot elevation in the U.S.A. If the heating
value of the gas has been reduced, these rules do not
apply. To identify the proper orifi ce size, check with the
local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750ºC, shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or whether
plastered or unplastered shall be considered combustible
materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
*Maximum Vent Blower On
**Canada Only
Heat & Glo • Paloma • 7031-220 Rev. P • 10/084
Page 5
Note: The following requirements reference various
Massachuset ts and national codes not contained in this
document.
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above fi nished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satisfi ed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas fi tter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the fl oor
level where the gas equipment is to be installed. In addition, the installing plumber or gas fi tter shall observe that
a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the
responsibility of the property owner to secure the services
of qualifi ed licensed professionals for the installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
fl oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Inspection
The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
• The equipment listed in Chapter 10 entitled “Equip-
ment Not Required To Be Vented” in the most current
edition of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure separate from the dwelling, building or structure used in
whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
• Detailed instructions for the installation of the venting
system design or the venting system components; and
• A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi es
“special venting systems”, the following requirements
shall be satisfi ed by the manufacturer:
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certifi ed.
Signage
A metal or plastic identifi cation plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) inch in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/085
• The referenced “special venting system” instructions
shall be included with the appliance or equipment installation instructions; and
• The “special venting systems” shall be Product Ap-
proved by the Board, and the instructions for that system shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Commonwealth of Massachusetts requirements.
Page 6
2
2
Getting Started
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
C. Inspect Appliance and Components
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fi re offi cials or authorities having jurisdic-
tion about restrictions, installation inspection, and permits.
When planning an appliance installation, it’s necessary to
determine the following information before installing:
• Where the appliance is to be installed.
• The vent system confi guration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and fi nishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
• Carefully remove the appliance and components from
the packaging.
• Remove door and set aside on protective surface. See
page 44.
• Remove log set and component pack from fi rebox.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
• Read all of the instructions before starting the installation. Follow these instructions carefully during the
installation to ensure maximum safety and benefi t.
WARNING
Keep appliance dry.
• Mold or rust may cause odors.
• Water may damage controls.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Reciprocating saw Framing material
Pliers Hi temp caulking material
Hammer Gloves
Phillips screwdriver Framing square
Flat blade screwdriver Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Wrenches
Ratchets/Sockets Allen Wrench Set
Manometer Voltmeter
Tape measure 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
One 1/4 inch female connection (for optional fan)
Noncorrosive leak check solution or combustible gas detector
• Installation and use of any damaged appliance or vent
system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
WARNING
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
Heat & Glo • Paloma • 7031-220 Rev. P • 10/086
Page 7
3
3
Framing and Clearances
Note:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see fi gure 3.1).
B. Clearances to Combustibles
F
B
A
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffi c areas.
NOTE: For actual appliance dimensions refer to Section 12.
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat
from the appliance causing discoloration or odor.
Note: Flooring beneath appliance may reach 90 degrees plus
room ambient temperature. Check with flooring manufacturer
for maximum temperature allowed on flooring surfaces.
WARNING
Fire Risk.
• Locate and install appliance to all clearance
specifi cations in manual.
WARNING
Fire Risk.
Odor Risk.
Tipping Risk
• Install gas stove on a stable, level platform/
fl oor strong enough to support gas stove
without tipping.
• USE wood fl ooring, ceramic tile, brick hearth
or high pressure laminate fl ooring applied
directly over the sub-fl ooring material.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/088
Page 9
4
4
Termination Locations
A. Vent Termination Minimum Clearances
WARNING
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or other
materials.
Failure to keep insulation or other materials
away from vent pipe may cause fi re.
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
(See Figure 4.4 for specifi c clearances)
Figure 4.1
HORIZONTAL
OVERHANG
2 FT.
MIN.
GAS DIRECT VENT
TERMINATION CAP
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
* 3 foot minimum in snow regions
Figure 4.2 Minimum height from roof to lowest discharge
opening
20 INCHES MIN.
LOWEST
DISCHARGE
OPENING
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
X
12
ROOF PITCH
IS X/ 12
VERTICAL
WALL
Figure 4.2 specifi es minimum vent heights for various
pitched roofs.
GAS, WOOD OR FUEL
OIL TERMINATION
GAS
TERMINATION
C
A
Gas
Termination
A6 in.20 in. min.Horizontal distance between terminations
B20 in.24 in. min.Distance to perpendicular wall
C18 in.18 in. Vertical distance between terminations
Figure 4.3 Multiple Vertical Termination
Heat & Glo • Paloma • 7031-220 Rev. P • 10/089
Wood & Fuel Oil
Termination
B
Comments
Page 10
V
R
M
N
P
Q
(See Note 2)
T
S
Electrical
V
Service
V
S
V
D*
= VENT TERMINAL
V
A = 12 inches.................clearances above grade, veranda,
(See Note 1)
X
= AIR SUPPLY INLET
porch, deck or balcony
B = 12 inches.................clearances to window or door
that may be opened, or to permanently closed window. (Glass)
D* = 18 inches.................vertical clearance to unventilated
soffi t or to ventilated soffi t located
above the terminal
*30 inches ................for vinyl clad soffi ts and below
electrical service
F = 9 inches..................clearance to outside corner
G = 6 inches...................clearance to inside corner
H = 3 ft. (Canada) ..........not to be installed above a gas
meter/regulator assembly within 3
feet (90 cm) horizontally from the
center-line of the regulator
I = 3 ft ...........................clearance to gas service regulator
vent outlet
J = 9 inches (U.S.A.)
12 inches (Canada) clearance to non-mechanical
air supply inlet to building or the
combustion air inlet to any other
appliance
K = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (pow-
ered) air supply inlet
= AREA WHERE TERMINAL IS NOT PERMITTED
L** = 7 ft. ......................... clearance above paved
(See Note 1)
sidewalk or a paved driveway
located on public property
M*** = 18 inches................ clearance under veranda, porch,
deck, balcony or overhang
42 inches ............... vinyl
S = 6 inches................. clearance from sides of electri-
(See Note 5)
cal service
T = 12 inches................ clearance above electrical
(See Note 5)
service
Alcove Applications
N = 6 inches ..................non-vinyl sidewalls
12 inches ................vinyl sidewalls
P = 8 ft.
Q
MIN
1 cap3 feet 2 x Q
2 caps6 feet 1 x Q
3 caps9 feet2/3 x Q
4 caps12 feet1/2 x Q
Q
= # termination caps x 3 R
MIN
= (2 / # termination caps) x Q
MAX
R
MAX
ACTUAL
ACTUAL
ACTUAL
ACTUAL
ACTUAL
** a vent shall not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor, or meets Note 2.
NOTE 1: On private property where termination is less than 7 feet above
a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap
shield is suggested. (See vents components page)
NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions specifi ed for
vinyl or non-vinyl siding and soffi ts. 1. There must be 3 feet minimum
between termination caps. 2. All mechanical air intakes within 10 feet
of a termination cap must be a minimum of 3 feet below the termination
cap. 3. All gravity air intakes within 3 feet of a termination cap must be a
minimum of 1 foot below the termination cap.
NOTE 3: Local codes or regulations may require different
clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to
doors or other traffi c areas.
NOTE 5: Location of the vent termination must not interfere with
access to the electrical service.
WARNING: In the U.S: V ent system termination is NOT permitted in
screened porches. Y ou must follow side wall, overhang and ground
clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with
two or more sides open. You must follow all side walls, overhang
and ground clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper performance
of the appliance when the venting system does not meet these
Figure 4.4 Minimum Clearances for Termination
requirements.
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0810
Page 11
5
5
Vent Information
A. Venting Components
In order to comply with applicable codes and product
warranties, use only following venting components:
• Hearth & Home Technologies (HHT)
• Simpson Dura-Vent (SDV)
DO NOT USE FIELD-FABRICATED VENTING COMPONENTS. Refer to the venting manufacturer’s instructions.
This product is approved to be vented either horizontally,
through the side wall or vertically through the roof. You
may vent through a Class A or masonry chimney if an
approved adapter is used.
This appliance is a direct vent heater. All combustion air
must come directly from the outside of the building. The
vent pipe for this unit consists of an inner and an outer
pipe. The inner pipe carries the appliance exhaust out of
the system, and the outer pipe brings fresh combustion
air into the appliance.
• A round support box/wall thimble or heat shield is
required when the venting passes through a combustible wall.
• A support box or ceiling fi restop is required when the
venting passes through a ceiling.
• Roof fl ashing and a storm collar are required when
venting passes through the roof.
• Follow instructions provided with the venting for installation of these items.Em velissit lorpero et, velestie
B. Use of Elbows
CAUTION
ALL vent confi guration specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not
followed.
Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).
Two 45º elbows may be used in place of one 90º elbow . On
45º runs, one foot of diagonal is equal to 8-1/2 (216 mm)
inches horizontal run and 8-1/2 (216 mm) inches vertical
run. A length of straight pipe is allowed between two 45º
elbows (see Figure 5.1).
Vertical
12 in.
8-1/2 in.
WARNING
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
fl ue serving a separate solid-fuel or gas burning
appliance.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the fl ue.
8-1/2 in.
Horizontal
Figure 5.1
C. Measuring Standards
Vertical and horizontal measurements were made using
the following standards.
1. Pipe measurements are from center line to center line.
2. Horizontal terminations are measured to the outside
mounting surface (fl ange of termination cap) (see
Figure 4.1) on page 9.
3. Vertical terminations are measured to the top of the last
pipe before termination cap.
4. Horizontal pipe installed level with no rise.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0811
Page 12
D. How to Use the Vent Graph
1. Measure the distance from the top of appliance to the
center of the 90° elbow. On the graph below, draw a
horizontal line from that measurement on the vertical
axis across until it intersects with the slanted line.
2. From the point of this intersection, draw a vertical line
to the bottom of the graph.
3. The point at which this line meets the bottom line of the
graph is the maximum length of the horizontal run.
Example 1: If the vertical dimension from the top of the
appliance to the center of the 90° elbow is 7 ft. (2 m), the
horizontal run to the outer wall fl ange must not exceed 13
ft. (4 m).
Example 2: If the vertical dimension from the top of the
appliance is 21 ft. (6.4 m), the horizontal run to the outer
wall fl ange must not exceed 9 ft. (3 m).
4. Each 90° elbow is equivalent to 3 ft. (914 mm) of vent
pipe and each 45° elbow is equivalent to 1 ft. (305
mm) of vent pipe, and must be subtracted from vent
pipe run. A single vertical to horizontal 90° elbow is
already calculated into the allowable 15 ft. (5 m) run.
Each additional 90° elbow reduces the maximum
horizontal distance by 3 ft. (914 mm).
Example: The use of three elbows would reduce the
allowable horizontal run to 9 ft. (3 - 1 = 2 elbows x 3 ft.
= 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)
E. Venting Guidelines
• The maximum horizontal vent run is 15 ft. (5 m) when
the vertical vent rise is 10 ft. (3 m).
• The minimum horizontal vent run is 11-5/8 in. (295
mm).
• Horizontal sections require a 1/4 in. (6 mm) rise for
every 12 in. (305 mm) of horizontal travel.
Horizontal sections require noncombustible support
•
every 3 ft. (914 mm), e.g. wall strap.
• Wall thickness: Minimum 4 in. (102 mm). Maximum 20
in. (508 mm).
• Vent Diameter: Exterior 6-5/8 in. (168 mm); Inner 4 in.
(102 mm).
EXCEPTION FOR REAR VENT KIT
SNKD), HORIZONTAL INSTALLATION:
• The maximum horizontal vent run is 3 ft. (914 mm).
• The maximum horizontal vent run with a 45° elbow is 2
ft. (610 mm).
•
No external minimum rise is required. The minimum
horizontal vent run is 11-5/8 in. (295 mm).
• For any vertical rise when rear venting, a minimum of 2
ft. (610 mm) vertical must be used prior to any horizontal
run.
• Snorkel Kit (SLK-SNKD) must be used for horizontal
vent runs with no vertical rise.
3 ft. (914 mm) Maximum Horizontal run with no
vertical pipe and with 1/4 in. (6 mm) rise per foot.
TOTAL HORIZONTAL RUN TO
OUTSIDE OF EXTERIOR WALL
(INCLUDING ELBOWS)
To adjust the vent restrictor
plate, see page 34.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0812
Page 13
F. Horizontal Termination
90º ELBOW
PIPE LENGTH
WALL THIMBLE COVER
PIPE LENGTH
TERMINATION CAP
WALL THIMBLE
2. Direct vent pipe is designed with a locking connection.
To connect the venting system to the appliance flue
outlet, a twist-lock adapter is built into the appliance
at the factory. Wall thickness may vary. Remember
to include wall thickness in minimum clearances when
figuring venting lengths for your installation needs.
3. Female ends of direct vent pipe/elbows are designed
to slide straight onto the male ends of adjacent pipes
by orienting the pipe indentations so they match and
slide into the entry slots on the male ends, see Figure
5.4. Push the pipe sections completely together, then
twist-lock one section clockwise approximately onequarter turn, until the two sections are fully locked.
The female locking lugs may not be visible from the
outside. They may be located by examining the inside
of the female ends.
FEMALE LOCKING LUGS
MALE LOCKING
CHOOSE BETWEEN
INTERIOR WALL
- 2 IN. (51 MM)
CLEARANCE FROM
REAR OF STOVE
CENTER LINE
SNORKEL CAP KIT (SLK-SNKD) MUST BE
USED FOR HORIZONTAL VENT RUNS
Figure 5.3
SLIM LINE
WALL THIMBLE
TRIM RING
WITH NO VERTICAL RISE.
STANDARD
OR
WALL THIMBLE
SNORKEL CAP
MINIMUM OF 6 IN. (152 MM) OF
PIPE THROUGH THE WALL
1. Determine the desired location of the appliance. Check
to ensure that wall studs or roof rafters are not in the
way when the venting system is being planned. If this
is the case, you may want to adjust the location of the
appliance.
WARNING
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Ensure vent components are locked
together correctly.
• Pipe may separate if not properly joined.
Figure 5.4
WARNING
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation
instructions.
Connect vent sections per installation
instructions.
• Maintain all clearances to combustibles.
• Do NOT allow vent to sag below
connection point to appliance.
• Maintain specifi ed slope (if required).
Improper support may allow vent to sag or separate.
4. For installations using a round support box/wall thimble
(check pipe manufacturer's instructions), mark the wall
for a 10 in. x 10 in. (254 mm x 254 mm) square hole.
The center of the square hole should line up with the
center line of the horizontal pipe, as shown in Figure
5.5. Cut and frame the hole in the exterior wall where
the vent will be terminated. If the wall being penetrated
is constructed of noncombustible material, i.e. masonry
block or concrete, a 7 in. (178 mm) diameter hole is
acceptable.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0813
Page 14
CENTER LINE
WOOD
SCREW
CENTER OF HOLE
WALL
THIMBLE
Figure 5.5
CENTER LINE
5. Installation requires a minimum of 6 in. (152 mm)
horizontal run of vent with a 1/4 in. (6 mm) rise run
towards the termination. Each 1 ft. (305 mm) of
horizontal venting must include a 1/4 in. (6 mm) rise.
Never allow the vent to run downward. This could cause
high temperatures and may present the possibility of
a fire. The location of the horizontal vent termination
on an exterior wall must meet all local and national
building codes, and must not be easily blocked or
obstructed, see Figure 4.4 on page 10.
6. For installations requiring a vertical rise on the exterior
of the building, the HHT RHVK snorkel kit (Part #844-
8921) is available with a 14 in. (356 mm) and a 36
in. (914 mm) tall snorkel termination cap. Follow the
same installation procedures as used for standard
horizontal terminations. If the snorkel termination must
be installed below grade (i.e. basement application),
proper drainage must be provided to prevent water
from entering the snorkel termination. Do not backfill
around snorkel termination.
7. Position the horizontal termination cap in the center of
the 10 in. x 10 in. (254 mm x 254 mm) square hole and
run a bead of non-hardening mastic around its outside
edges, so as to make a seal between it and the wall,
attach termination cap to the exterior wall with the four
wood screws provided. The arrow on the vent cap
should be pointing up (Figure 5.6).
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0814
HOT
WALL THIMBLE
Figure 5.6
PART HHW2 #841-0670
(PREFERRED)
8. The four wood screws provided should be replaced
with appropriate fasteners for stucco, brick, concrete,
or other types of sidings.
9. Termination cap HHW2 (Part #841-0670) is highly
recommended on a building with vinyl siding, as the
vinyl siding standoff is built in. The pilot hole will be
2 in. (51 mm) closer to the bottom of the square than
the top. Using a framing square, draw a 14 in. x 14 in.
(356 mm x 356 mm) square around the pilot hole. See
Figure 5.7.
8 in.
(203 mm)
7 in.
(178 mm)
Figure 5.7
7 in.
(178 mm)
6 in.
(152 mm)
10. If you are installing termination cap HHW2, the pipe
will be off center on flashing). Ensure that proper
clearances to combustible materials are maintained. If
you are using an approved termination cap other than
HHW2 (part #841-0670) on a building with vinyl siding,
a vinyl siding standoff should be installed between the
termination cap and the exterior wall (Figure 5.8, on
the next page). Follow manufacturer’s instructions for
attaching the vinyl siding standoff to the horizontal
termination cap. The vinyl siding standoff prevents
excessive heat from possibly melting the vinyl siding
material. The vent terminal cap shall not be recessed
into a wall or siding. Remove siding from the area
where the standoff will be located.
Page 15
VINYL SIDING
WARNING
APPLY SEALANT TO
ALL FOUR SIDES
SCREWS
BOLT HORIZONTAL TOP
TO VINYL STANDOFF
WALL
THIMBLE
COVER
WALL THIMBLE
Figure 5.8
SCREWS
VINYL SIDING STANDOFF WITH
SIDING BENEATH REMOVED
11. Place the wall thimble cover over the pipe assembly
and slide the appliance and vent assembly towards
the wall, carefully inserting the vent pipe into the vent
termination cap assembly . It is important that the vent
pipe extend into the vent termination cap a sufficient
distance so as to result in a minimum pipe overlap of
1-1/4 in. (32 mm). Secure the connection between the
vent pipe and the vent termination cap by attaching
the two sheet metal strips extending from the vent
termination cap assembly into the outer wall of the
vent pipe. Use the two sheet metal screws provided
to connect the strips to the pipe section (Figure 5.9).
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Ensure vent components are locked
together correctly.
• Pipe may separate if not properly joined.
WARNING
Do NOT connect a pipe section to a termination cap
without using the telescoping flue section found on the
termination cap.
WARNING
Burn Risk
• Local codes may require installation of a
cap shield to prevent anything or anyone
from touching the hot cap.
1/4 in. (6 mm)
FOLD STRAP
HERE
SHEET METAL
SCREW
WALL
WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION
Figure 5.9
STRAP
THIMBLE
Note: The attachment from the vent pipe to the vent
termination cap must be sealed with silicone. Termination
caps shall not be recessed into a wall or siding.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0815
Page 16
G. Vertical Termination
VERTICAL TERMINATION
CAP USE PART #SLK-991DA
STORM COLLAR
FLASHING
FIRESTOP
SUPPORT BOX
PIPE LENGTH
On vertical terminations use only Part #SLK-991DA or like
components. See page 55.
Figure 5.10
1. Check the installation instructions for required 1 in.
(25 mm) clearances (air space) to combustibles when
passing through ceilings, walls, roofs, enclosures,
attic rafters, or other nearby combustible surfaces.
See page 16, Figure 5.15. Check the instructions for
maximum vertical rise of the venting system, and any
maximum horizontal offset limitations. All offsets must
fall within the set parameters of the vent graph (Figure
5.2) located on page 12.
Note: Maximum ver tical rise allowable is 40 f t. (10.7 m),
Figure 5.11 . Maximum number of 45º elbows permitted for a
vertical installation is eight, provided their inst allation does
not decrease maximum allowable horizontal run (as specifi ed
by vent graph, on page 12).
40 ft. (12 m)
MAXIMUM
Figure 5.11
2. Set the gas appliance in its desired location. Drop
a plumb bob down from the ceiling to the position of
the appliance flue exit, and mark the location where
the vent will penetrate the ceiling. Drill a small hole
at this point. Next, drop a plumb bob from the roof to
the hole previously drilled in the ceiling, and mark the
spot where the vent will penetrate the roof. Determine
if ceiling joists, roof rafters, or other framing will
obstruct the venting system. You may wish to relocate
the appliance, or to offset, as shown in Figure 5.12 to
avoid cutting load bearing members.
PLUMBER'S TAPE
CONNECTED TO
WALL STRAP
WALL
STRAP
WARNING
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as
specifi ed.
• Do not pack air space with insulation or other
materials.
Failure to keep insulation or other materials
away from vent pipe may cause fi re.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0816
Figure 5.12
TWO 45º
ELBOWS
Page 17
3. To install the round support box/wall thimble cover in
L
a flat ceiling, cut a 10 in. (254 mm) square hole in the
ceiling, centered on the hole drilled in Step 2. Frame
the hole as shown in Figure 5.13.
CEILING JOISTS
FRAMING
ROUND CEILING
SUPPORT BOX/WAL
THIMBLE COVER
SHINGLES OVERLAP ON
TOP EDGE OF FLASHING
Figure 5.14
CAP AND STORM
COLLAR NOT SHOWN
FOR CLARITY
1-1/2 in. (38 mm)
LONG WOOD
SCREWS
Figure 5.13
4. Assemble the desired lengths of pipe and elbows
necessary to reach from the appliance up through
the round support box. Ensure that all pipe and elbow
connections are in their fully twist-locked position.
Assemble as instructed.
5. Cut a hole in the roof centered on the small drill hole
placed in the roof in Step 2. The hole should be of
sufficient size to meet the minimum requirements for
clearance to combustibles, as specified. Continue
to assemble lengths of pipe and elbows necessary
to reach from the ceiling support box/wall thimble up
through the roof line. Galvanized pipe and elbows may
be utilized in the attic, as well as above the roofline.
The galvanized finish is desirable above the roofline,
due to its higher corrosion resistance.
• If an offset is necessary in the attic to avoid
obstructions, it is important to support the vent pipe
every 3 ft. (914 mm) to avoid excessive stress on the
elbows, and possible separation. Wall straps are
available for this purpose, Figure 5.12, page 16.
• Whenever possible, use 45° elbows, instead of 90°
elbows. The 45° elbow offers less restriction to the
flow of flue gases and intake air.
6. Slip the flashing over the pipe section(s) protruding
through the roof. Secure the base of the flashing to
the roof with roofing nails. Ensure the roofing material
overlaps the top edge of the flashing as shown in
Figure 5.14. Verify that the chimney is the required
height above the roof. See roof pitch table, Figure 4.3,
on page 9.
7. Continue to assemble pipe sections until the height of
the vent (before adding the termination cap) meets the
minimum code requirements as outlined in the current
CAN/CGA-B149 Installation Codes (in Canada), the
National Fuel Gas Code NFPA 54/ANSI Z223.1 (in
USA), or local codes. Note that for steep roof pitches,
the vent height must be increased. See Roof Pitch
Table (Figure 4.3, on page 9). In high wind conditions,
nearby trees adjoining rooflines, steep pitched roofs,
and other similar factors can result in poor draft, or
down drafting. In these cases increasing the vent
height or switching to the high wind termination cap
may solve this problem.
8. Slip the storm collar over the pipe, and push it down
to the top of the flashing (Figure 5.15). Use nonhardening sealant above and below the joint between
the storm collar and the pipe.
OPTIONAL HIGH WIND
TERMINATION CAP
SECURE FLASHING WITH
NON-HARDENING SEALANT AND
ROOFING NAILS
Figure 5.15
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0817
Page 18
9. Twist-lock the vent cap and seal.
Note: For multi-story vertical installations, a ceiling firestop
is required at the second floor, and any subsequent floors
(Figure 5.16). The opening should be framed to 10 in. x 10 in.
(254 mm x 254 mm) inside dimensions, in the same manner
as shown in Figure 5.13.
NAILS
CEILING FIRESTOP
MINIMUM 1 in.(25 mm)
CLEARANCE
MINIMUM 1 in.(25 mm)
CLEARANCE
Figure 5.16
MINIMUM 1 in. (25 mm)
CLEARANCE
MINIMUM 1 in.(25 mm)
CLEARANCE
WARNING
Fire Risk.
Explosion Risk.
• Any occupied areas above the first floor,
including closets and storage spaces, which
the vertical vent passed through must be
enclosed. The enclosure may be framed
and sheetrocked with standard construction
materials; however, refer to these installation
instructions for the minimum allowable
clearance between the outside of the vent
pipe and the combustible surfaces of the
enclosure. Do not fill any of the required air
space with insulation.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0818
Page 19
H. Cathedral Ceiling
1. Follow installation Steps 1 and 2 under vertical installation section, page 16.
2. Remove shingles or other roof covering as necessary
to cut the rectangular hole for the support box. Cut
the hole 1/8 in. (3 mm) larger than the support box
outline.
3. Lower the support box through the hole in the roof
until the bottom of the support box protrudes at least 2
in. (51 mm) below the ceiling (Figure 5.17). Align the
support box both vertically and horizontally with a level.
Temporarily tack the support box in place through the
inside walls and into the roof sheathing.
Figure 5.18
LEVEL
CATHEDRAL CEILING
SUPPORT BOX
2 in. (51 mm) MIN. BELOW
FINISHED CEILING
CUT HOLE 1/8 in. (3 mm)
GREATER IN SIZE THAN
PATTERN OF SUPPORT
BOX AS IT IS PROJECTED
ONTO ROOF LINE
Figure 5.17
4. Using tin snips, cut the support box from the top corners
down to the roofline, and fold the resulting flaps over
the roof sheathing (Figure 5.18). Before nailing it to the
roof, run a bead of non-hardening mastic around the
top edges of the support box to make a seal between it
and the roof. Clean out any combustible material from
inside the support box.
5. Assemble the desired lengths of pipe and elbows
necessary to reach from the appliance up through
the round support box. Ensure that all pipe and elbow
connections are in their fully twist-locked position.
Assemble as instructed.
6. Place the support clamp (provided with the support
box) inside the support box (at the bottom), and secure
to the pipe section. The clamp allows the support box
to support the weight of the pipe sections. Continue to
add pipe sections until you are above the roofline.
7. Complete the cathedral ceiling installation by following
the same procedures outlined in steps 7 through 9 for
vertical installations, pages 17-18.
8. Install the black trim collar around the outside of the
cathedral ceiling support box (Figure 5.19). The two
pieces of the trim collar slide over one another to allow
for easy adjustment around the support box. Using the
six screws provided, secure the four corners and the
overlapping sections of the trim collar to the ceiling.
You may want to predrill the holes for the overlapped
sections for ease of installation.
TRIM COLLAR
CATHEDRAL CEILING
SUPPORT BOX
SCREWS
Figure 5.19
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0819
Page 20
I. Class A Metal Chimney
TERMINATION
CAP PART #SLK-991DA
EXISTING METAL
CHIMNEY SYSTEM
RETRO CONNECTOR
DIRECT VENT
PIPE
TOP ADAPTER
FLASHING
4 in. (102 mm)
FLEX PIPE
4. Pass the flex pipe down through the center of the
chimney system, and center the top adapter on the top
of the chimney pipe. Drill four 1/8 in. (3 mm) diameter
holes through the top adapter, and into the chimney
top. Ensure that you are drilling into the metal on the
chimney . T wist lock the high wind termination cap onto
the top adapter (Figures 5.22 and 5.23).
Figure 5.20
CAUTION
Ensure that existing chimney is functionally sound and
clean.
• Have inspection done by qualifi ed chimney sweep or
professional installer BEFORE converting to direct vent
appliance.
1. Remove existing chimney cap.
2. Measure the distance from the top of the chimney to
the bottom of the ceiling support box, add 3 in. (76
mm) to this measurement, and cut a section of 4 in.
(101 mm) flex pipe to that length (the flex should be
fully extended).
3. Connect the end of the flex pipe section to the
underside of the top adapter, using four sheet metal
screws (Figure 5.21).
TOP ADAPTER
FLEX PIPE
SHEET METAL SCREWS
Figure 5.21
Figure 5.22
HIGH WIND
TERMINATION CAP
SHEET METAL SCREWS
DRILL FOUR 1/8 IN. (3 MM)
DIAMETER HOLES
Figure 5.23
5. Pull the flex pipe down through the ceiling support box,
until it protrudes approximately 3 in. (76 mm). Connect
the flex pipe to the retro connector, and attach with
sheet metal screws.
6. Push the flex pipe back up into the ceiling support box,
center the retro connector, and attach it to the support
box with sheet metal screws.
7. The connection between the appliance and the retro
connector may be completed with sections of direct
vent pipe.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0820
Page 21
J. Existing Masonry Chimney
T ype A
TERMINATION CAP PART
CO-AXIAL TO CO-LINEAR
CONNECTOR PART
#923GCL
PIPE LENGTH
(OPTIONAL)
Type C - Up & Out Installation
CHIMNEY LINER
#923GK
3 IN. (76 MM) FLEX LINER
SHOWING TWO 30 FT.
(9 M) SECTIONS OF
FLEX LINER
Type B
CO-AXIAL TO CO-LINEAR
CONNECTOR PART #923GCL
PIPE LENGTH
(OPTIONAL)
Type D - Hearth Mount
CHIMNEY LINER TERMINATION
CAP PART #923GK
30 ft. (9 m) OF 3 in. (76 mm)
FLEX LINER EXHAUST
SECTION
THIS SECTION OF THE
CHIMNEY MUST BE SEALED
THE CHIMNEY MUST BE
SEALED FROM THE 4 ft. (1 m)
SECTION TO TERMINATION
USING A SMOKE SHELF OR A
DAMPER. THE SEAL SHOULD
BE 6 in. (152 mm) BELOW THE
END OF THE 4 ft. (1 m) AIR
INTAKE SECTION.
4 ft. (1 m) OF 3 in. (76 mm)
FLEX LINER
“AIR INTAKE SECTION”
Figure 5.24
90º ELBOW
DIRECT
VENT PIPE
TOP ADAPTER
RETRO
CONNECTOR
TERMINATION CAP
PART #SLK-991DA
FLASHING
4 in. (102 mm)
FLEX LINER
CHIMNEY LINER
TERMINATION CAP
PART #923GK
30 FT. (9 m) OF 3 IN. (76 mm)
FLEX LINER
EXHAUST SECTION
THIS SECTION OF
THE CHIMNEY MUST
BE SEALED
ALCOVE CLEARANCE TO
COMBUSTIBLES MUST BE
MAINTAINED
CHIMNEY MUST BE SEALED
FROM 4 FT. (1 m) SECTION TO
TERMINATION USING A SMOKE
SHELF OR A DAMPER*.
SEAL SHOULD BE 6 IN. (152 mm)
BELOW END OF 4 FT. (1 m) AIR
INTAKE SECTION.
4 FT. (1 m) OF 3 IN. (76 mm)
FLEX LINER
AIR INTAKE SECTION
CO-AXIAL TO CO-LINEAR
CONNECTOR PART# 923GCL
*NOTE: In the Commonwealth of Massachusetts, the word damper shall
be replaced with the words fl ue restrictor.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0821
Page 22
CAUTION
Ensure that existing chimney is functionally sound and
clean.
• Have inspection done by qualifi ed chimney sweep or
professional installer BEFORE converting to direct vent
appliance.
1. Before cutting any holes, assemble the desired
sections of direct vent pipe to determine the center of
the masonry penetration.
2. Once the center point of the penetration has been
determined, cut a 6 in. (152 mm) diameter hole
in the masonry. If the hole is too large, the retro
connector might not mount properly; if the hole is
too small, the appliance might starve for intake air. If
there is a frame wall in front of the masonry wall, cut
and frame a 10 in. (254 mm) square opening in the
wall (centered around the 6 in. (152 mm) masonry
opening). If there is sheet rock only (no studs) in
front of the masonry the 10 in. (254 mm) opening is
still needed, but does not need to be framed. If the
hole is framed a round support box/wall thimble is
required. This allows the retro connector to mount
directly on the masonry and provide the correct
clearances to combustibles (Figure 5.25).
STUDWALL
10 in. x 10 in.
(254 mm x 254 mm)
FRAMED OPENING IN WALL
RETRO
CONNECTOR
MASONRY
CHIMNEY
CUT AND BEND FLASHING
AS NEEDED TO FIT CHIMNEY
Figure 5.26
SEALANT-ADHESIVE
4. To determine the length of flex needed, measure from
3 in. (76 mm) above the top of the flashing down to the
level of the opening. Add the distance from the center
of the chimney out through the wall. Cut a piece of 4
in. (102 mm) flex to this length (extended to its nominal
length). Be sure to leave 2-3 in. (51-76 mm) of flex
above the existing chimney to allow for connection to
the termination kit.
5. Connect the flex liner to the top adapter using three
sheet metal screws (Figure 5.21 page 20).
6. Feed the flex liner through the flashing into the
chimney . Carefully feed the flex liner down the chimney
to the bottom and out the opening in the masonry wall,
forming an angle to line up the flex liner with the vent
opening on the appliance.
FOUR MASONRY BOLTS
(NOT INCLUDED)
NOTE: For hearth applications refer to page 20, Figure 5.24
for the use of the 923GCL co-axial to co-linear appliance connector.
Figure 5.25
WALL THIMBLE COVER
3. Secure the flashing to the top of the masonry chimney
using a bead of non-hardening sealant-adhesive. If the
flashing is larger than the top of the chimney, cut and
fold flashing as needed to fit chimney (Figure 5.26).
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0822
WARNING
Fire Risk.
Explosion Risk.
• Do not let the fl ex liner sag below the level
at which it will connect to the appliance
or connector. This could allow hot gas to
become trapped and potentially become a
fi re hazard. The fl ex liner path should always
be sloped up toward the termination cap.
7. If additional lengths of flex liner are needed to span
the chimney height, use a flex coupler to connect the
pieces of flex liner together. Connect the flex to the
coupler by using four sheet metal screws for each side
(Figure 5.27, on the next page).
Page 23
FLEX LINER
FLEX COUPLER
6 in. (152 mm) DIAMETER
OPENING IN MASONRY WALL
SHEET METAL SCREWS
Figure 5.27
8. Secure the top adapter to the flashing. Use three sheet
metal screws through the side of the top adapter into
the flange on the flashing (Figure 5.28). Twist lock the
high wind termination cap on to the top adapter.
HIGH WIND TERMINATION
CAP #SLK-991DA
TOP ADAPTOR
THREE SHEET
METAL SCREWS
RETRO
CONNECTOR
THREE MASONRY BOLTS
Figure 5.29
(NOT INCLUDED)
10. Slide wall thimble cover over retro connector and
secure with masonry bolts (Figure 5.30). If you have
a framed wall in front of the masonry, use wood
screws to mount wall thimble cover to framed wall,
over retro connector and 10 in. (254 mm) square
framed opening (Figure 5.25, page 22). If needed,
add a section of direct vent pipe to the retro connector
in order to extend through the opening in the wall
thimble cover.
RETRO
CONNECTOR
Figure 5.28
FLASHING
9. Attach the flex to the retro connector. Use three sheet
metal screws to attach the flex liner to the connector
(Figure 5.29). Mount the retro connector to the
masonry wall using masonry bolts. Redrill larger holes
on connector as needed. Be careful to ensure that the
connector is centered in the opening and the mounting
holes line up with the masonry wall.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0823
WALL
THIMBLE COVER
FOUR MASONRY BOLTS
(NOT INCLUDED)
Figure 5.30
11. The connection between the appliance and the retro
connector may be completed with sections of direct
vent pipe.
Page 24
K. Slim Line Wall Thimble
Before you begin review the venting confi gurations in Fig-
ures A, B and C on the next page.
Assembling Slim Line Trim Ring and Heat Shield
Figure 5.31 Lay the trim ring on fl at surface and bend up
the six welded brackets into a 90 degree position. The
brackets along the outer edge of the ring are for locating
the ring in the center of the hole.
Figure 5.33 Attach the heat shield to the trim ring with
the four screws provided. Screws go through the heat
shield and into the brackets on the trim ring.
Installing Slim Line Trim Ring and Heat Shield
Measure from the fl oor to the center of the vent pipe. Cut
out a 9-1/2 in. (241 mm) hole in the wall. Hold the trim
ring/heat shield assembly in place and put a mark on the
shield with a black marker where it protrudes through the
exterior wall. See Figure A on the next page.
Use that mark as a guide to trim off excess heat shield
with a pair of sheet metal shears.
Figure 5.32 The heat shield is shipped fl at and must be
hand bent into a half circle before attaching it to the trim
ring. Bend the heat shield as shown.
CAUTION
Sharp Edges
• Wear protective gloves and safety
glasses during installation.
3/4
3/4
3/4
Figure 5.34 When installing the trim ring/heat shield
assembly make sure the trim ring is centered in the hole
and that the shield is above the pipe. There must be a
minimum of 3/4 in. (19 mm) minimum clearance maintained to combustibles from the top of the heat shield.
Ensure that framing on the inside of the wall is a minimum inner framing diameter of 10 in. x 10. in. (254 mm
x 254 mm).
The four trim ring mounting screws provided should be
replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0824
Page 25
FIG. A 90 DEGREE ELBOW
PLACE MARK WHERE PROTRUDES THROUGH
EXTERIOR WALL TO CUT OFF EXCESS
90° ELBOW
CENTER LINE
PIPE LENGTH
USE HEAT SHIELD / WALL THIMBLE
TRIM RING
PIPE LENGTH
HTI VENT HHW2 PART #841-0670
(RECOMMENDED FOR OPTIMUM PERFORMANCE)
FIG. B 45 DEGREE ELBOW
TRIM RING
45° ELBOW
HEAT SHIELD
OVER PIPE
5 IN. (127 MM) CLEARANCE
FROM APPLIANCE CORNER
TO COMBUSTIBLE WALL
5 IN. (127 MM) CLEARANCE
FROM APPLIANCE CORNER
FIG. C MINIMUM CLEARANCE
MINIMUM OF 6 IN. (152 MM)
INTERIOR WALL - 2 IN. (51
MM) CLEARANCE FROM
REAR OF STOVE
CENTER LINE
Snorkel Cap Kit (SLK-SNKD) must be used for horizontal vent runs with no vertical rise.
Figure 5.35
OF PIPE THROUGH THE WALL
WALL THIMBLE
HTI VENT HHW2 PART
HEAT SHIELD OVER
TOP HALF OF PIPE
TRIM RING
#841-0670 (RECOMMENDED
FOR OPTIMUM PERFORMANCE)
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0825
Page 26
6
6
TAB ON BACK
OF BURNER
Gas Information
A. Fuel Conversions
Before making gas connections ensure that appliance being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to
meet the appliance and locality needs must be made by
a qualifi ed technician using Hearth & Home Technologies
specifi ed and approved parts.
B. Converting to LP Gas
WARNING
Fire Risk.
Explosion Risk.
• If the information in these instructions is not
followed exactly, a fi re, explosion or produc-
tion of carbon monoxide may result causing
property damage, personal injury or loss of
life. The qualifi ed service agency is respon-
sible for the proper installation of this kit. The
installation is not proper and complete until
all the operation of the converted appliance
is checked as specifi ed in the manufactur-
er's instructions supplied with the kit.
• This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all applicable codes and requirements of the authority
having jurisdiction.
Massachusetts installation must be performed
by a licensed plumber or gas fi tter.)
Any damaged valve components should not be installed.
If a valve or regulator has been dropped or appears to
have been modifi ed, the valve or regulator should not be
installed.
T ools required: #2 Phillips head screwdriver; Power drill
(a 90° drill is helpful); Tamper-resistant Torx Driver TR20;
#2 Phillips bit; 5/32 in. (4 mm) Allen wrench; 3/8 in. (10
mm) open end wrench.
Coversion component list:
• LP Burner orifi ce: #52DMS
• Pilot orifi ce
• Gas valve regulator
• Propane conversion plate
• LP label
(In the Commonwealth of
CAUTION
The gas supply shall be shut off prior to disconnecting the
electrical power before proceeding with the conversion.
PROCEDURE FOR CONVERSION:
.
Turn off gas to appliance by closing the inlet line
1
valve.
2. Turn off power to the module and valve.
3. Remove the front door assembly, inner glass door
assembly and logs.
4. To remove the burner, loosen the front screw on the
pilot bracket. Slide the tab on the left side at the back
of the burner out from under the pilot bracket, and out
of the fi rebox. (Fig. 6.1)
TAB ON BACK
OF BURNER
Figure 6.1
5. Remove the inlet gas line from valve connection.
6. Remove the six hold down screws from the fi rebox
bottom plate.
7. Disconnect the orange and green wires from the control valve and lift the bottom plate and valve assembly
from the appliance.
8. Remove the orange and white wires from the ignition
module which is located on the control panel (see
Figure 7.1 on page 31).
9. Using a #20 tamper-proof Torx, remove the regulator
and rubber gasket on face of valve (see Figure 6.2).
Discard both the regulator and gasket.
10. Install the new regulator along with the new rubber
gasket included in the conversion kit (see Figure 6.2).
WARNING
Fire Risk.
Explosion Risk.
Gas Leak Risk.
• Rubber gasket must be seated properly on
valve face.
• Do no install a valve or regulator that has
been dropped.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0826
Page 27
VALVE
REATTACH
PILOT SHIELD
13. Place the round LP label on the bottom base pan.
Place the propane conversion plate adjacent to the
existing rating plate.
RUBBER
GASKET
REGULATOR
Figure 6.2
11. Using a 3/8 in. (10 mm) nut driver or wrench, remove
the NG orifi ce and replace it with the LP orifi ce pro-
vided in this kit (see Figure 6.3).
Note: The qualifi ed service agency installing this conversion
MUST enter the day, month, and year, and sign the propane
conversion plate added to the appliance.
14. Reinstall the bottom plate and valve assembly into
the appliance. Reinstall the six hold down screws.
15. Reconnect the inlet gas line to the valve assembly
and turn on the gas line valve. Check the incoming
line for leaks.
16. Reconnect the electrical power supply.
17. Reconnect the orange wire to the valve assembly.
This will allow for the pilot to turn on with the control
switch in the "ON" position. Check all pilot line connections for leaks. (See Figure 6.4)
18. Use a commercially available, non-corrosive leak
check solution to test for leaks around the pilot. Be
sure to rinse off all leak check solution following testing. See Figure 6.4 for leak check points. Extinguish
the pilot.
WARNING
Shock or burn risk.
• Disconnect green wire from gas valve.
Failure to disconnect green wire could result
in severe burns.
Figure 6.3
12. Unscrew the pilot tube fi tting on the pilot and replace
the orifi ce spud with the one included in the conver-
sion kit (see Figure 6.4).
ORIFICE SPUD
PILOT TUBE
ASSEMBLY
19. Reinstall the green wire on the valve.
20. Before reinstalling the burner, ensure that the shutter
setting is fully open. Reattach pilot to pilot shield to
burner (see Figure 6.5). Retighten the screw.
REATTACH
PILOT SHIELD
Figure 6.5
Figure 6.4
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0827
Page 28
21. Place one piece grommet over pilot wires and supply
tube. Slide and snap into mating rectangular slot.
Make sure it fi ts securely. See Figure 6.6.
Figure 6.6
WARNING
Fire Risk.
Explosion Risk.
If the information in these instructions is
•
not followed exactly, a fi re, explosion or
production of carbon monoxide may result
causing property damage, personal injury or
loss of life.
• The qualifi ed service agency is responsible
for the proper installation of this conversion
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer’s
instructions supplied with the kit.
22. Light the pilot and burner and use a commercially
available, non-corrosive leak check solution to test for
leaks. Be sure to rinse off all leak check solution following testing and prior to placing the appliance into
operation. Extinguish the pilot and burner.
23. Reinstall the logs by following the log placement
instructions.
24. Reinstall the inner glass door assembly and the front
door assembly.
25. Turn on the appliance to check for proper burner
fl ame pattern.
26. Verify that the signed and dated conversion plate has
been added to the appliance.
Verify the performance of the ignition system:
1. Verify pilot sparks, pilot lights, pilot stops sparking, and
the main burner turns "ON".
2. Turn the appliance "OFF". V erify that both the pilot and
burner turn "OFF".
3. Repeat Step 1 above.
4. With the burner "ON", remove the green wire con-
nected to the valve. The main burner should shut
"OFF".
5. Reattach the green wire to the valve, and the main
burner should turn back "ON".
6. With the main burner "ON", remove the orange wire
connected to the valve. The pilot and burner should go
out, and the pilot will start to spark.
7. Turn the appliance "OFF" and reattach the orange wire
to the valve.
WARNING
Fire Risk.
Explosion Risk.
• Disconnect any electrical cords and turn
off gas supply to unit before proceeding if
converting fuel on an appliance already fully
installed.
C. Gas Pressures
Proper input pressures are required for optimum appliance performance. Gas line sizing requirements need to
be made following NFPA54.
WARNING
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
WARNING
Verify inlet pressures.
• High pressure may cause overfi re condition.
• Low pressure may cause explosion.
• Verify minimum pressures when other
household gas appliances are operating.
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
Pressure requirements for appliance are shown in the
table below. Minimum pressures must be met when other
household gas appliances are operating.
PressureNatural GasPropane
Minimum inlet pressure
Maximum inlet gas pressure
Manifold pressure
5.0 inches
w.c.
7.0 inches
w.c.
3.5 inches
w.c.
11.0 inches
w.c.
14.0 inches
w.c.
10.0 inches
w.c.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0828
Page 29
If the pressure is not suffi cient, ensure:
• The piping used is large enough.
• The supply regulator is adequately adjusted.
• That the total gas load for the residence does not
exceed the amount supplied.
The supply regulator (the regulator that attaches directly
to the residence inlet or to the propane tank) should supply
gas at the suggested input pressure listed above. Contact
the local gas supplier if the regulator is at an improper
pressure.
D. Gas Connection
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI
223.1. Installation should be done by a qualifi ed installer
approved and/or licensed as required by the locality. (In
the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter ).
Note: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13 mm) T-handle manual shut-of f valve and
fl exible gas connector are connected to the 1/2 inch (13 mm)
control valve inlet.
• If substituting for these components, please consult
local codes for compliance.
WARNING
Gas Leak Risk
• Support control when attaching pipe to
prevent bending gas line.
WARNING
Fire or Explosion Hazard
• Gas buildup during line purge may ignite.
• Purge should be performed by qualifi ed technician.
• Ensure adequate ventilation.
• Ensure there are no ignition sources such as
sparks or open fl ames.
• A small amount of air will be in the gas supply lines.
When fi rst lighting appliance it will take a short time for
air to purge from lines. When purging is complete the
appliance will light and operate normally.
Air only needs to be purged again if gas valve has been
turned to the OFF position.
WARNING
CHECK FOR GAS LEAKS
Explosion Risk
Fire Risk
Asphyxiation Risk
• Check all fi ttings and connections.
• Do not use open fl ame.
• After the gas line installation is complete, all
connections must be tightened and checked
for leaks with a commercially-available,
non-corrosive leak check solution. Be sure
to rinse off all leak check solution following
testing.
Fittings and connections may have loosened
during shipping and handling.
Note: The gap between supply piping and gas access hole
may be caulked with high temperature c aulk o r stu ffed with
non-combustible, unfaced insulation to prevent cold air
infi ltration.
Leak test all gas line joints and the gas control valve prior
to and after starting the appliance.
Before making the gas connection, ensure that the
appliance you are installing is designed for the type of
gas being supplied. This information can be found on the
ratings label under the appliance. If the appliance has
been converted to propane (LP), the valve cover should
have a label stating that the appliance has been converted
to propane.
Connect the gas line at the 3/8 in. (10 mm) pipe connector
on the valve at the back of appliance. We recommend
connecting the appliance with an approved flex gas line.
If flex gas lines are not approved in your area, you must
connect a hard pipe to the gas hookup.
You must supply a manual shut-off valve in a visible
location within 3 ft. (914 mm) of the appliance.
WARNING
Fire hazard.
Do NOT change the valve settings.
• This valve has been preset at the factory.
• Changing valve settings may result in fi re
hazard or bodily injury.
HIGH AL TITUDE INST ALLATIONS
Omni-T est Laboratories, Inc. listed gas appliances are tested
and approved without requiring changes for elevations from
0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifi ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. If the heating value of the
gas has been reduced, these rules do not apply. To identify
the proper orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0829
Page 30
7
7
This appliance is equipped with a three
pronged (grounding) plug for your protection
against shock hazard and should be plugged
directly into a prop
Electrical Information
A. Recommendation for Wire
See Figure 7.1 for recommended maximum lead length
(two wire) when using wall thermostat/switch.
NOTE: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
1. This appliance may be used with a wall switch, wall
mounted thermostat and / or a remote control
2. If using thermostat, use one compatible with a millivolt
gas valve system.
3. Follow parameters for locating thermostat (see individual thermostat instructions) to ensure proper operation
of appliance.
4. Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
6. Keep wire lengths as short as possible by removing
any excess wire length.
7. Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
8. Ensure the thermostat is mounted level for accurate
readings.
9. The thermostat should be mounted on an inside wall
and not in direct line with the appliance convection air.
10. If the thermostat is located too close to the appliance, you may need to set the temperature setting
slightly higher to maintain the desired temperature
in your home.
Do not connect this appliance to a thermostat serving
any other appliance.
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.
WARNING
Shock hazard.
•
This appliance is equipped with a three
pronged (grounding) plug for your protection
against shock hazard and should be plugged
directly into a properly grounded three prong
receptacle. Do not cut or remove the grounding prong from this plug.
C. IntelliFire® Ignition System Wiring
This appliance requires a 1 10 V AC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 7.2 on the next page.
This appliance is equipped with an IntelliFire® control
valve which operates on a 3 volt system.
This appliance is supplied with a 3 volt AC transformer,
which requires the installation of the supplied junction
box.
This appliance is supplied with a battery pack that
requires two D cell batteries (not included). Batteries
cannot be placed in the battery pack while using the 3
volt AC transformer. Conversely, the transformer must be
unplugged if the battery pack is used.
CAUTION
Battery polarity must be correct or module damage will
occur.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0830
Page 31
SWITCH
NEUTRAL
PLUG-IN 3V
TRANSFORMER
ON/OFF
WALL
IGNITION
MODULE
VALVE
GROUND
(3V)
REMOTE
CONTROL
SPARKER/SENSOR
HOT
FLAME
BATTERY
PACK
IGNITION MODULE
3 VAC
APPLIANCE CHASSIS
BLACK
RED
I
S
WHT
ORG
GROUND TO
*
INTERMITTENT
PILOT IGNITOR
TRANSFORMER
PLUG IN
JUNCTION BOX
Figure 7.2
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
D. Loss of Power and Battery Backup Usage
1. Disconnect the power supply.
2. Remove the front door assembly and lower access
panel.
3. Place two "D" cell batteries into the battery holder.
(Figure 7.3)
4. Turn on appliance and verify it is operational.
5. Replace lower access panel and front door assembly.
3 VAC
BRN
ON/OFF SWITCH
BRN
PIGGYBACK
ORG
VALVE
GRN
NOTE: Appliance will not operate
unless properly grounded.
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.
Unplug when
using batteries
CAUTION
If IPI battery back-up is installed:
• Do not install batteries if the backup mode may not be used
for extended time.
• Batteries may leak.
• Install batteries only when needed for power outage.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0831
BATTERY LOCATION
Figure 7.3
Page 32
E. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 7.4):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box
to the appliance using a minimum of 14-3 with ground
wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female connector to the red
(switch leg) wire, route it through the knockout in the face
of the junction box, and connect to the top fan switch
connector (1/4 inch male) as shown.
MINIMUM 14-3 AWG
WITH GROUND
JUNCTION BOX
Red
Figure 7.4 Junction Box Wired to Wall Switch
Red
White
Black
Red
Black
Green
White
Green
SWITCH
Black
White
Green
POWER
SUPPLY WIRES
SWITCH BOX
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0832
Page 33
8
8
PILOT ASSEMBLY
IGNITER SHIELD
Appliance Setup
A. Remove Shipping Materials
Remove shipping materials from inside or underneath the
fi rebox.
Do not remove the ignitor shield on the pilot assembly
until set up is complete. (Figure 8.1)
PILOT ASSEMBL Y
IGNITER SHIELD
Figure 8.1
Gas line and power cord are shipped inside back panel.
To access the gas line and power cord, remove the top
plate from the appliance. Remove and retain the two
Allen head screws that hold the back panel in place. Refer
to Figure 8.6, page 33.
Using the black grommet located in the component bag,
slide it into the bottom of the back panel and feed the power
cord through the grommet, as shown in Figure 8.2.
B. Unbolting Appliance from the Pallet
The appliance is bolted and screwed to the pallet for shipping. Use a 1/2 in. socket to remove the bolt in center of
bottom plate. Use a Phillips screwdriver to remove the two
screws in the front of the bottom plate and the two screws
holding the metal strap across the back of the appliance.
Refer to Figure 8.3 for locations.
Figure 8.3
Figure 8.2
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0833
Page 34
C. Leveling and Lagging Down the Appliance
Lagging the appliance down is REQUIRED.
WARNING
Fire Risk.
Odor Risk.
Tipping Risk
• Install gas stove on a stable, level platform/
fl oor strong enough to support gas stove
without tipping.
• USE wood fl ooring, ceramic tile, brick hearth
or high pressure laminate fl ooring applied
directly over the sub-fl ooring material.
LAGGING
CLEARANCE
HOLE
Figure 8.6
Place the lag bolt from the component bag in the center
hole in the bottom plate (lagging clearance hole). The
appliance must be lagged down securely to prevent tipping forward.
Level
screw
Figure 8.4
Figure 8.5
Securing holes
Lag bolt hole
Level
screw
After unbolting the appliance from the pallet, insert two
1/4 20 x 1/1/2 counterscrews.
Using pliers, adjust the counterscrews to level the appliance.
Figure 8.7
Using pliers, adjust the counterscrews to level the appliance.
D. Accessories
Install approved accessories per instructions included
with accessories. See Service Parts List for appropriate
accessories. Refer to Section 16.
WARNING
Shock or fi re risk.
Use ONLY optional accessories approved for
this appliance.
• Using non-listed accessories voids warranty.
• Using non-listed accessories may result in a
safety hazard.
• Only Hearth & Home Technologies approved
accessories may be used safely.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0834
Page 35
E. Top to Rear Vent Conversion
PILOT ASSEMBLY
INNER EXTENSION COLLAR
DV ADAPTER
Note: When installing this appliance in a rear vent confi gura-
tion with no vertical rise, a Snorkel Kit must be used.
Kit Contents: Top cover (no hole); Back panel (with hole).
T ools Required: Power drill; #2 Phillips bit; 5/32 in. (4 mm)
Allen wrench; 5/8 in. (16 mm) open end wrench; high-temp
silicone sealant (optional).
1. Remove the front door assembly by lifting it off of the
spring-loaded latches on top of the appliance. Remove
the inner glass door by disengaging the spring-loaded
latches at the bottom of the appliance and lifting it off
of the two spring loaded latches at the top of the appliance.
2. Remove the top plate with hole and discard. (Figure 8.8).
INNER EXTENSION COLLAR
DV ADAPTER
Figure 8.10
6. Remove the four screws from the cover plate on rear
of appliance. Retain screws. (see Figure 8.11).
Figure 8.8
3. Remove and retain the Allen head screws that hold the
solid back panel in place. (Figure 8.9) Remove and
discard the solid back panel.
PILOT ASSEMBL Y
Figure 8.9
4. Remove the four screws from the DV adapter collar.
(Figure 8.10) Set aside DV adapter collar and screws.
5. Remove the inner extension starter collar (Shown in
Figure 8.10) and set aside.
Figure 8.11
7. Install the outer collar with gasket to the rear of appliance with screws previously removed. Install the inner
extension starter collar. (Figure 8.12).
8. Install the new back panel (with hole) to the rear of
appliance. Replace the allen head screws removed in
Step 3 to hold the back panel in place. (Figure 8.12).
Figure 8.12
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0835
Page 36
9. Install the cover plate removed from the rear of the
Top Vent
Rear Vent
appliance to the top of the appliance with the screws
previously removed. (Figure 8.13).
10. Install the new solid top.
Figure 8.13
F. Shutter Adjustment
The shutter is located on the underside of the burner, on
the burner neck (see Figure 8.14).
G. Installing the Vent Restrictor
The vent restrictor plate must be installed before installing
the baffle.
On the top of inside firebox for top vent ,on back of firebox
for rear vent, loosen the three screws out about 1/8 in.
Place the vent restrictor plate over the the screws and
slide into locking position. Retighten the screws. (See
Figure 8.15.)
Top Vent
Rear Vent
Figure 8.15
For vertical venting above 6 ft. a vent restrictor is required.
After installing the vent restrictor plate, remove the inner
rings as needed for proper flame height. (Refer to Figure
8.16.)
Figure 8.14
Figure 8.16
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0836
Page 37
H. Installing the Baffl e
PILOT ASSEMBLY
IGNITER SHIELD
PIN
The baffl e is shipped wrapped, inside the fi rebox. Install
the baffl e with the embedded “T” side up, place it on top
of the brackets on the inside of the fi rebox, ensuring back
edge of baffl e makes contact with the back of the fi rebox.
Place log #1 into the cradle in the burner. Lean the log
back towards right corner of firebox.
Figure 8.17
I. Positioning the Logs
Remove the ignitor shield from the pilot assembly prior to
installing the logs. (Figure 8.18).
PILOT ASSEMBL Y
IGNITER SHIELD
Figure 8.18
While still breakable, the logs do not become fragile until
after the appliance is burned and they have cured. After
curing, any handling must be done with care as breakage
can easily occur.
Note: Logs have been designed to work specifi cally with the
burner of this appliance. Exact placement will ensure proper
operation of your gas appliance.
Figure 8.19
Locate log #2 over the pin in log #1 and into notch in log
#1. Lean the log back toward the left corner of the firebox.
PIN
Figure 8.20
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0837
Page 38
J. Mineral Wool
WARNING
Explosion Risk.
• Follow ember placement instructions in manual.
• Do NOT place embers directly over burner ports.
• Replace ember material annually.
Improperly placed embers interferes with proper burner
operation.
Apply dime size pieces sparingly along front edge of
burner. Do not completely block ports.
Figure 8.21
K. Optional Blower
The GFK-160A Blower has been designed to circulate
room air through the appliance to enhance heat output.
The GFK-160A blower system operates on 120 VAC, 60
Hz power. This is available through a receptacle in the
factory installed junction box. The junction box is mounted
in the bottom of the appliance behind the access panel. A
variable speed control is provided with the blower system
to provide quiet forced air flow at the desired speeds. A
temperature sensor switch, which automatically turns the
blower ON/OFF, is also provided with this kit.
T ools Required: Powered screwdriver with Phillips head
bit; a fl ashlight is helpful.
Compare contents of carton with the actual parts received.
If any parts are missing or damaged, contact your dealer
before starting installation. Do not install a damaged
blower kit. See Figure 8.22.
BLOWER
CONTROL
KNOB
GROUND
Figure 8.22
CLIP
CONTROL
NUT
CONTROL
TEMP.
SENSOR
SWITCH
SPEED
WING
NUT
Installation precautions
The GFK-160A Blower kit is tested and safe when
installed in accordance with this installation manual. It is
your responsibility to read all instructions before starting
installation and to follow these instructions carefully
during installation to assure maximum benefit from, and
safe operation, of the blower.
This blower is carefully engineered and must be installed
only as specified. If you modify it or any of its components,
you may cause a fire hazard and will void the WARRANTY.
In addition, such action may void the coverage provided
by the owner's home insurance.
CAUTION
All wiring should be done by a qualified electrician and shall
be in compliance with local codes and with the National
Electric Code ANSI/NFPA NO. 70-current (in the United
States), or with the current CSA C22.1 Canadian Electric
Code (in Canada).
WARNING
Shock Risk
Explosion Risk
Do NOT wire 110V to gas control valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout
and may cause explosion.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0838
Page 39
Disconnect all electrical power. Remove the front door
Black Wires
Blue Wires
assembly by lifting off of appliance. Remove the lower
access door. See Figure 8.23.
Figure 8.23
Attach enclosed wires to the temperature sensor switch/
bracket assembly. The blue wire attaches to the rear of
the bracket and one of the black wires from the variable
speed control attaches closest to the prepunched screw
hole. See Figure 8.24.
Blue Wires
Black Wires
Locate the machine screw underneath the firebox on the
right side. Position the temperature sensor switch/bracket
assembly over the machine screw and attach with the
wing nut. Finger tighten. See Figure 8.26.
Figure 8.26
Note: The switch/bracket assembly must be installed so
that the sensor switc h makes contact with the bott om of
the fi rebox.
Attach rheostat in mating feature of control shield so that
orientation of control knob is downward. See Figure 8.27.
Figure 8.24
Feed the blue wire and other black wire from the variable
speed control behind the gas valve assembly. Insert the
wires into the slots indicated.
FAN OUTLET
CLIP
VARIABLE SPEED CONTROL
& TEMPERATURE SENSOR
SWITCH WIRES GO HERE
Figure 8.25
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0839
Figure 8.27
Page 40
Attach the ground clip to the control panel. Attach the
ground wire extension to the ground clip. Attach the the
blower ground wire to the ground wire extension.
Figure 8.28
Plug the blower cord into the FAN outlet on the junction
box. Refer to Figure 8.29, on the next page.
Push excess wires neatly towards the rear of the appliance.
Slide the blower into the bracket as indicated. Ensure
the blower is pushed back into the bracket to allow the
replacement of the lower access door. The magnet strips
located on the blower feet are designed to hold the blower
in place. See Figure 8.28.
Recommended operating procedures
Ignite the fire in the appliance with the variable speed
control switch in an "ON" position. The fan will automatically turn on when the temperature sensor switch closes
at approximately 110 degrees Fahrenheit. Heated air
should be delivered at the outlet grille. The fan will continue to operate after the appliance is turned OFF until the
sensor switch opens.
Various conditions (such as appliance model, type of
appliance installation, outside air temperature vs. inside
air temperature) can contribute to the length of the time
the blower remains on after the appliance is turned OFF.
The blower can be turned off manually with the speed
control switch.
Figure 8.29
Reattach the switch bracket with the two screws previously
removed.
Connect the variable speed control and the temperature
sensor switch to the short lead wires of the junction box by
plugging in the male and female connectors. See Figure
8.31, on the next page).
Plug appliance in. Turn the 110-120 VAC service "ON" at
the circuit breaker and turn the speed control switch to the
"ON" position.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0840
Page 41
Figure 8.30 Blower Wiring Diagram
BLUE
VARIABLE
SPEED SWITCH
TEMPERATURE
SENSOR SWITCH
JUNCTION BOX
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0841
Page 42
L. Remote Controls
3 Prong Cord
Wires Ties
T ools Required: Powered screwdriver with Phillips head
bit; hex wrench; 7/16 in. wrench; manometer.
Disconnect electricity at the circuit breaker before begin-
ning this installation.
Familiarize yourself with the instructions enclosed with
the remote control kit.
Remote receiver
Remove the top plate from the appliance. Remove the
Allen head screws attaching the back panel to the appliance. Retain screws.
Remove the front glass door assembly and the lower
access door.
Using two wire ties from the appliance component bag,
mount the remote receiver to the rear of the control
panel.
Feed the red and orange wires to the front of the appliance. Remove the optional blower, if installed.
Plug the 3-prong remote receiver cord into the junction
box (REM/AUX). Refer to Figure 8.30, on page 41.
Plug the 2-prong blower cord directly into the 3-prong
polarized plug on the back of the receiver. This receptacle
output is 110/120 VAC, 3 AMP.
Attach the ground wire from the blower onto the grounding clip.
Attach red wires from the remote receiver to the ON/OFF
switch.
Reinstall the blower into the blower bracket.
Installing flame control solenoid
Remove the screw and knob from the variable regulator
and discard. Unscrew the nut from the regulator and
discard.
Remove the bag containing a washer and blue and red
plungers from the side of the flame control solenoid.
Place washer on flame control solenoid. Insert the correct
plunger (blue - Natural Gas, red - LP) into the flame
control solenoid.
Thread the flame control solenoid with the correct plunger
into the thread hole in the variable regulator. Turn one to
two turns only. DO NOT tighten or damage may occur.
See Figure 8.32.
GAS CONTROL
VALVE
WASHER
VARIABLE
REGULATOR
FLAME CONTROL
SOLENOID
KNOB
Figure 8.31
3 Prong Cord
Wires Ties
NUT
VARIABLE
REGULATOR
WASHER
FLAME
CONTROL
SOLENOID
PLUNGER
Figure 8.32 Flame Control Solenoid
JAM NUT
SCREW
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0842
Page 43
Wiring the flame control solenoid:
Connect the two leads from the flame control solenoid to
the orange leads from the receiver. See Figure 8.33.
REMOTE
RECEIVER
BLUE
RED
ORANGE
JAM NUT
PLUNGER
REGULATOR
TOWER
BATTERY PACK
TRANSFORMER
3 VAC
PLUG
IN
BLACK
REMOTE RECEIVER
NGE
RED
ORANGE
ORA
RED
RED
IGNITION MODULE
RED
RED
RED
PIGGYBACK
ON/OFF SWITCH
ORANGE
ORANGE
3 VAC
BRN
BRN
RED JUMPER
WIRE TO
BROWN
RED
BRN
I
S
Figure 8.34 Remote Control IPI Wiring Diagram
INTERMITTENT
PILOT IGNITOR
TE
I
H
W
ORANGE
GROUND TO
FIREPLACE CHASSIS
ORANGE
VALVE
FLAME
CONTROL
SOLENOID
ORANGE
ORANGE
GREEN
Figure 8.33 Remote Receiver / Control Solenoid
Install a manometer into the pressure tap. Plug the remote
receiver into the 110-120 VAC power supply.
Light the appliance as directed in Section 9 of this manual.
Set the manifold pressure on the gas valve by rotating the
flame control solenoid. Adjust until the reading on the
manometer is 3.5 in. W.C. for natural gas or 10 in. W.C.
for LP.
Tighten the jam nut to the face of the variable regulator
body. See Figure 33 Turn the main gas knob on the gas
valve OFF . Remove the manometer from the pressure tap
and screw the tap closed.
Follow the instructions from the remote control kit to
operate and program the remote control.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0843
Page 44
M. Front Door Glass Assembly Installation
Remove the front door assembly by pulling bottom of front
away from appliance and lifting it off of the spring-loaded
latches on top of the appliance (see Figure 8.35).
Figure 8.35
N. Inner Glass Door Assembly Replacement
Turn the appliance OFF and let it cool down before replacing the inner glass door assembly.
With the front door assembly removed from the appliance,
remove the inner glass door assembly by disengaging the
spring-loaded latches at the bottom of the appliance and
lifting off of the two spring-loaded latches at the top of the
appliance.
Replace with a new inner glass door assembly.
Position the four fl at 1/4 in. (6 mm) spacer washers on the
front door so that the four mounting screws pass through
them. Position the glass over the front door.
Install the four protective barrels into the glass and the
four nylon washers on top of the glass.
From inside the door front, pass the screws through to the
outside and thread on the caps until tight. See Figure 8.36.
CAP AND BARREL FASTENER SYSTEM
Nylon washer on back
Screw
and front of glass
Finishing Cap
Protective barrel sleeve
through hole in the glass
Figure 8.37 Complete Assembly
WARNING
Handle glass doors with care.
• Inspect the gasket to ensure it is undamaged.
• Inspect the glass for cracks, chips or scratches.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door removed,
cracked, broken or scratched.
• Replace glass door assembly as a complete appliance.
Figure 8.36
Back side of
front door
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0844
Page 45
9
9
Operating Instructions
A. Before Lighting Appliance
Read this entire manual prior to using the appliance.
Failure to follow the instructions may result in property
damage, bodily injury, or even death.
CAUTION
If installing Intellifi re ignition battery backup:
• Do not install batteries if the backup mode may not be
used for extended time.
• Batteries may leak.
• Install batteries only when needed for power outage.
Before operating this appliance have a qualifi ed tech-
nician:
• Remove all shipping materials from inside and/or
underneath the fi rebox.
• Review proper placement of logs and mineral wool.
• Check the wiring.
• Check the baffl e adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper
position.
• Ensure that the fl ow of combustion and ventilation air is
not obstructed (front grilles and vent caps).
WARNING
Glass door must be in place when
appliance is operating.
Risk of:
• Combustion Fumes
• Fire
Do NOT operate appliance with glass
door removed.
• Open viewing glass for servicing only.
• Glass door MUST be in place and sealed before operating
appliance.
• Only use glass door certifi ed for use with appliance.
• Glass replacement should be done by qualifi ed technician.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
B. Controls
On/off Switch: When this switch is in the ON position, the
pilot ignitor is engaged until temperature is established.
The burner automatically turns on.
Valve Variable Control:
height from low (“LO”) to high (“HI”).
valve indicates the position of the knob.
Variable Speed Control: The blower is optional installed
on the appliance and this knob controls the speed of the
blower that pushes the heated air into the room.
Note: If using a remote control wall switch, or thermostat,
the On/Off Switch must be left “OFF”. Turning the On/Off
Switch to “ON” will keep the appliance on continually.
Valve Variable Control
This knob controls the flame
The indicator on the
CONTROL PANEL
Variable Speed
Control Knob
ON/OFF Switch
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
the owner’s information manual provided with this appliance.
For assistance or additional information consult a qualifi ed
installer, service agency or the gas supplier.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0845
Figure 9.1
Optional Future
Switch Location
Page 46
C. Lighting Appliance
IPI Ignition
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exact ly, a fi re or explosion may result causing proper t y
damage, personal injury or loss of life.
A. This appliance is equipped with
an intermittent pilot ignition (IPI)
device which automatically lights
the burner. Do not try to light the
burner by hand.
B.BEFORE LIGHTING, smell all
around the appliance area for gas.
Be sure to smell next to the fl oor
because some gas is heavier than
air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
WARNING:
DO NOT CONNECT 110 VAC TO
THE CONTROL VALVE.
Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to the owner’s information manual
provided with this appliance.
This appliance needs fresh air for
safe operation and must be installed
so there are provisions for adequate
combustion and ventilation air.
If not installed, operated, and maintained in accordance with the manufacturer’s instructions, this product
could expose you to substances in fuel
or fuel combustion which are known to
the State of California to cause cancer, birth defects, or other reproductive harm.
Keep burner and control compartment
clean. See installation and operating
instructions accompanying appliance.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
C. Do not use this appliance if any
part has been under water. Immediately call a qualifi ed service tech-
nician to inspect the appliance and
to replace any part of the control
system and any gas control which
has been under water.
CAUTION:
Hot while in operation. Do not touch.
Keep children, clothing, furniture, gasoline and other liquids having fl ammable
vapors away.
Do not operate the appliance with
panel(s) removed, cracked or broken.
Replacement of the panel(s) should be
done by a licensed or qualifi ed service
person.
NOT FOR USE
WITH SOLID FUEL
For use with natural gas and propane.
A conversion kit, as supplied by the
manufacturer, shall be used to convert
this appliance to the alternate fuel.
Also Certifi ed for Installation in a
Bedroom or a Bedsitting Room.
For assistance or additional information, consult a qualifi ed installer, ser-
vice agency or the gas supplier.
LIGHTING
INSTRUCTIONS
(IPI)
1. Turn off all electric power to the appliance.
2. This appliance is equipped with an ignition
device which automatically lights the burner.
Do not try to light the burner by hand.
GAS
VALVE
3. Wait fi ve (5) minutes to clear out any gas.
Then smell for gas, including near the fl oor. If
you smell gas, STOP! Follow “B” in the Safety
Information located on the left side of this label. If you don’t smell gas, go to next step.
4. Turn on all electric power to the appliance.
5. To light the burner, fl ip the ON/OFF switch to
the “ON” position. (The ON/OFF switch may
include a wall switch if so equipped).
6. If the appliance will not operate, follow the instructions “To Turn Off Gas to Appliance” and
call your service technician or gas supplier.
TO TURN OFF
GAS TO APPLIANCE
1. Turn off all electric power to the appliance if
service is to be performed.
2. Flip ON/OFF switch to the “OFF” position.
593-913D
Hearth & Home Technologies fi replace, please refer to www.fi replaces.com.
For additional information on operating your
Final inspection by
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0846
Page 47
D. After Appliance is Lit
Initial Break-in Procedure
When you light the appliance, you may notice that it produces heat which does have an associated odor or smell.
If you feel this odor is excessive it may require the initial
three to four hour continuous burn on high followed by a
second burn up to 12 hours to fully drive off any odor from
paint and lubricants used in the manufacturing process.
Condensation of the glass is normal.
CAUTION
• Prevent accidental appliance operation when not
attended.
• Unplug or remove batteries from remote control if absent
or if appliance will not be used for an extended period of
time.
• Property damage possible from elevated temperatures.
NOTE: The appliance should be run three to four hours
on the initial start-up. Turn it off and let it cool completely.
Remove and clean the glass. Replace the glass and run
the appliance for an additional 12 hours. This will help to
cure the products used in the paint and logs.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate any
odors associated with the appliance’s initial burning.
WARNING
Fire Risk.
High Temperatures.
Keep combustible household items away from
appliance.
Do NOT obstruct combustion and ventilation air.
• Do NOT place combustible items on top of or
in front of appliance.
• Keep furniture, draperies away from
appliance.
CAUTION
Smoke and odors released during initial operation.
• Open windows for air circulation.
• Leave room during initial operation.
• Smoke may set off smoke detectors.
Smoke and odors may be irritating to sensitive
individuals.
WARNING
Fire Hazard.
Keep combustible materials, gasoline and
other fl ammable vapors and liquids clear of
appliance.
• Do NOT store fl ammable materials in the
appliance’s vicinity.
• Do NOT use gasoline, lantern fuel, kerosene,
charcoal lighter fl uid or similar liquids in this
appliance.
• Combustible materials may ignite.
E. Frequently Asked Questions
ISSUESOLUTIONS
Condensation on the glass
Blue fl ames
Odor from appliance
Film on the glass
Metallic noise
Is it normal to see the pilot fl ame burn
continually?
This is a result of gas combustion and temperature variations. As the appliance warms, this
condensation will disappear.
This is a result of normal operation and the fl ames will begin to yellow as the appliance is al-
lowed to burn for 20 to 40 minutes.
When fi rst operated, this appliance may release an odor for the fi rst several hours.
This is caused by the curing of the paint and the burning off of any oils remaining from
manufacturing.
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing
process. A non-abrasive cleaner such as gas fi replace glass cleaner may be necessary. See
your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when
ON/OFF is turned off.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0847
Page 48
10
10
Troubleshooting
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do
experience a problem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the
corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed service technician.
A. Intellifi re Ignition System
SymptomPossible CauseCorrective Action
1. The ignitor/module
makes noise, but no
spark.
2. Pilot won’t light,
there is no noise or
spark.
a. Incorrect wiring.Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor
are connected to correct terminals on module and pilot assembly.
Reversed wires at the module may cause system to make sparking
noise, but spark may not be present at pilot hood.
b. Loose connections or electrical
shorts in the wiring.
c. Ignitor gap is too large.Verify gap of igniter to pilot hood. The gap should be approximately
d. Faulty module.Turn ON/OFF rocker switch or wall switch to OFF position. Remove
a. Transformer installed correctly.Verify that transformer is installed and plugged into module. Check
b. A shorted or loose connection in wiring confi guration or wiring harness.
Verify no loose connections or electrical shorts in wiring from module to pilot assembly. Rod closest to pilot hood should be ignitor.
Verify connections underneath pilot assembly are tight; also verify
connections are not grounding out to metal chassis, pilot burner,
pilot enclosure, mesh screen if present, or any other metal object.
.17 inch or 1/8 inch.
ignitor wire “I” from module. Place ON/OFF Rocker switch or wall
switch in ON position. Hold ground wire about 3/16 inch away from
“I” terminal on module. If there is no spark at “I” terminal module
must be replaced. If there is a spark at “I” terminal, module is fi ne.
Inspect pilot assembly for shorted sparker wire or cracked insulator
around electrode.
voltage of transformer under load at spade connection on module
with ON/OFF switch in ON position. Acceptable readings of a good
transformer are between 3.2 and 2.8 volts AC.
Remove and reinstall the wiring harness that plugs into module.
Verify there is a tight fi t. Verify pilot assembly wiring to module.
Remove and verify continuity of each wire in wiring harness.
3. Pilot lights but continues to spark, and
main burner will not ignite. (If the pilot continues to spark after the
pilot fl ame has been lit, fl ame rectifi cation has
not occurred.)
c. Improper wall switch wiring.Verify that 110/VAC power is “ON” to junction box.
d. Module not grounded.Verify black ground wire from module wire harness is grounded to
metal chassis of appliance.
e. Faulty module.Turn ON/OFF rocker switch or wall switch to OFF position. Remove
ignitor wire “I” from module. Place ON/OFF Rocker switch or wall
switch in ON position. Hold ground wire about 3/16 inch away from
“I” terminal on module. If there is no spark at “I” terminal module
must be replaced. If there is a spark at “I” terminal, module is fi ne.
Inspect pilot assembly for shorted sparker wire or cracked insulator
around electrode.
a. A shorted or loose connection in
sensor rod.
b. Poor fl ame rectifi cation or contami-
nated sensor rod.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0848
Verify all connections to wiring diagram in manual. Verify connections underneath pilot assembly are tight. Verify connections are
not grounding out to metal chassis, pilot burner, pilot enclosure or
screen if present, or any other metal object.
Verify that fl ame is engulfi ng sensor rod. If the pilot assembly does
not have a ground strap, consider installing one to increase fl ame
rectifi cation. Verify correct pilot orifi ce is installed and inlet gas
specifi cations. Flame carries rectifi cation current, not the gas. If fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or
too high an inlet pressure can cause pilot fl ame to lift. The sensor
rod may be contaminated. Clean sensor rod with emery cloth.
Page 49
Intellifi re Ignition System - (continued)
SymptomPossible CauseCorrective Action
3. (Continued) Pilot lights
but continues to spark,
and main burner will not
ignite. (If the pilot continues to spark after the pilot
fl ame has been lit, fl ame
rectifi cation has not oc-
curred.)
4. Pilot sparks, but Pilot
will not light.
c. Module is not grounded.Verify that module is securely grounded to metal chassis
of appliance. Verify that wire harness is fi rmly connected to
module.
d. Damaged pilot assembly or dirty sensor
rod.
e. Faulty module.Turn ON/OFF rocker switch or wall switch to OFF posi-
a. Correct gas supply.Verify that incoming gas line ball valve is “open”. Verify that
b. Ignitor gap is too large.Verify that spark gap from ignitor to pilot hood is .17 in. or
c. Module is not grounded.Verify module is securely grounded to metal chassis of
Verify that ceramic insulator around the sensor rod is not
cracked, damaged, or loose. Verify connection from sensor
rod to white sensor wire. Clean sensor rod with emery cloth
to remove any contaminants that may have accumulated
on sensor rod. Verify continuity with a multimeter with
ohms set at lowest range.
tion. Remove ignitor wire “I” from module. Place ON/OFF
Rocker switch or wall switch in ON position. Hold ground
wire about 3/16 inch away from “I” terminal on module. If
there is no spark at “I” terminal module must be replaced.
If there is a spark at “I” terminal, module is fi ne. Inspect
pilot assembly for shorted sparker wire or cracked insulator
around electrode.
inlet pressure reading is within acceptable limits, inlet pressure must not exceed 14 in. W.C.
1/8 in.
appliance.
d. Module voltage output / Valve/Pilot
solenoid ohms readings.
Verify battery voltage is at least 2.7 volts. Replace batteries
if voltage is below 2.7.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0849
Page 50
11
11
Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed
service technician should perform an appliance checkup at the beginning of each heating season.
Maintaining and Servicing Appliance
WARNING
Risk of injury or property damage.
Before servicing:
• Turn off gas.
• Turn off electricity to appliance.
• Disable remote control, if one is present.
• Ensure appliance is completely cooled.
After servicing:
• Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for servicing.
WARNING
Annual inspection by qualifi ed technician recommended.
Check:
• Condition of glass, glass assembly and glass seal.
• Obstructions of combustion and ventilation air.
• Burner ignition and operation.
• Burner air shutter adjustment
• Gas connections and fi ttings.
• Obstructions of termination cap.
Clean:
• Glass
• Air passageways, grilles,
control compartment
• Burner, burner ports
Risk of:
• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors
CAUTION
Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours operation.
Longer operation without cleaning glass may
cause a permanent white fi lm on glass.
When cleaning glass door:
• Avoid striking, scratching or slamming glass.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white fi lm.
• Do NOT clean glass when hot.
• Turn off appliance after 3-4 hours of operation and
ALLOW TO COOL.
• Remove and clean glass assembly.
• Replace glass assembly and operate appliance for
additional 12 hours.
Refer to maintenance instructions.
WARNING
Inspect external vent cap regularly.
• Ensure no debris blocks cap.
• Combustible materials blocking cap may ignite.
• Restricted air fl ow affects burner operation.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0850
Page 51
A. Maintenance Tasks
InspectMaintenance Tasks
1. Inspect for scratches, dents or other damage and repair as necessary.
2. Verify no obstructions to airfl ow through the louvers.
3. Verify maintenance of proper clearance to combustible household objects.
Gasket Seal, Glass
Assembly and Glass
Valve Compartment
and Firebox Top
Logs1. Inspect for broken, damaged, or missing logs. Replace as necessary.
Firebox1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.
Burner Ignition and
Operation
Venting1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.
Remote controls1. Verify operation of remote.
1. Inspect gasket seal and its condition.
2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.
3. Confi rm there is no damage to glass or glass frame. Replace as necessary.
4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components are
intact and operating properly. Replace as necessary.
5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.
1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw
tips that have penetrated the sheet metal are sharp and should be avoided.
2. Remove any foreign objects.
3. Verify unobstructed air circulation.
2. Verify correct log placement and no fl ame impingement causing sooting. Correct as necessary.
2. Replace appliance if fi rebox has been perforated.
1. Verify burner is properly secured and aligned with pilot or igniter.
2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.
3. Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.
4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.
5. Inspect for lifting or other fl ame problems.
6. Inspect orifi ce for soot, dirt or corrosion.
7. Verify manifold and inlet pressures. Adjust regulator as required.
8. Inspect pilot fl ame strength. Clean or replace orifi ce as necessary.
9. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery
cloth or replace as required.
10. Verify millivolt output. Replace as necessary.
2. Confi rm that termination cap remains clear and unobstructed by plants, etc.
3. Verify that termination cap clearance to subsequent construction (building additions, decks, fences or
sheds) has been maintained.
4. Inspect for corrosion or separation.
5. Verify weather stripping, sealing and fl ashing remains intact.
2. Replace batteries in remote transmitters and battery-powered receivers.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0851
Page 52
12
12
A. Appliance Dimension Diagram Without Stone Surround
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3.
Figure 12.2 Appliance Dimensions with Stone Surround
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0853
G
Page 54
C. Vent Components Diagram
9-7/16 in.
240 mm
SLP45
6-5/8 in.
168 mm
13-1/4 in.
7-1/4 in.
184 mm
6-9/16 in.
167 mm
337 mm
6-5/8 in.
168 mm
6-9/16 in.
167 mm
6-5/8 in.
168 mm
5-1/4 in.
133 mm
6 in.
152 mm
SLP4
6-5/8 in.
168 mm
6-9/16 in.
167 mm
6-5/8 in.
168 mm
9-3/4 in.
248 mm
6-1/2 in.
165 mm
SLP90
7-1/4 in.
184 mm
6-9/16 in.
167 mm
9-1/4 in.
235 mm
6-5/8 in.
168 mm
SLP6
6-5/8 in.
168 mm
13-1/4 in.
337 mm
SLP6A
6-5/8 in.
168 mm
6-9/16 in.
167 mm
25-1/4 in.
641 mm
SLP12A
6-5/8 in.
168 mm
6-9/16 in.
167 mm
37-1/4 in.
946 mm
6-5/8 in.
168 mm
6-9/16 in.
167 mm
49-1/4 in.
1251 mm
6-9/16 in.
167 mm
SLP12
Note: Pipes overlap 1-3/8 inches (34.93 mm) at each joint.
Figure 12.3 SLP Series Vent Components
SLP24
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0854
SLP36
SLP48
Page 55
D. Vent Components List
COMPONENTS
SLP-WT-BKCeiling Support / Wall Thimble, Black
SLP-CCS-BKCathedral Ceiling Support, Black
SLP6-BK6 inch Pipe Length, Black
SLP4-BK9 inch Pipe Length, Black
SLP12-BK12 inch Pipe Length, Black
SLP34-BK24 inch Pipe Length, Black
SLP36-BK36 inch Pipe Length, Black
SLP48-BK48 inch Pipe Length, Black
SLP6A-BK11 inch - 14-5/8 inch Pipe Length, Black
SLP12A-BK12 inch - 17 inch Pipe, Adjustable, Black
SLP45-BK45 degree Elbow, Black
SLP90-BK90 degree Elbow, Black
SLP44 inch Pipe
SLP66 inch Pipe
SLP1212 inch Pipe
SLP2424 inch Pipe
SLP3636 inch Pipe
SLP4848 inch Pipe
SLP4545 degree Elbow
SLP9090 degree Elbow
SLP6A3-6 in. Adjustable Pipe Extension
SLP12A3-12 in. Adjustable Pipe Extension
SLP-RF60/12 - 6/12 Roof Flashing
SLP-RF127/12 - 12/12 Roof Flashing
SL-SCDStorm Collar
SLP-FSCeiling Firestop
SLP-WSWall Firestop
SLP-HVSPipe Support Hanger
950Vinyl Protector Kit - SL Pipe
DRC-RADIUSDecorative Radius Cover
HTI-DV-WTWall Thimble
RF4-8Roof Flashing
TERMINATION KITS
SLP-TRAP2Trapezoid Termination Kit
SLP-TVHWVertical Termination Cap - High Wind
SLP-SK-BKHorizontal Termination Kit (includes 904B,
930D, SLK-01TRD)
SLK-SNKDSnorkel Kit
LINK-STOVE Adapter Kit (includes 30 ft. of 4 inch flex,
apapters, wall thimble, masonry
& ZC flashing, 991DA cap and hardware
package
VPK-DVVinyl Siding Protector Kit
SLP-HHW2HHW2 Horizontal High Wind Cap
(recommended for optimal performance)
899-4491HHW2K Horizontal Kit (one 90 degree
black wall thimble, 24 inch black
pipe, 11 inch - 14-5/8 inch adjustable
vent, HHW2 termination cap)
844-8921RHVK Snorkel Kit (with Dura-Vent parts
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
ITEMDESCRIPTIONCOMMENTSPART NUMBER
Temp Sensor
Switch On/Off rocker
Variable Speed Control
Air Defl ector 2123-185
Flue collar
Flue Restrictor Plate
107-531
230-0730
100-510A
7018-117
7031-222
Stocked
at Depot
Y
Y
Y
Conversion Kit NG NGK-PALOMA
Conversion Kit LP LPK-PALOMA
Pilot Orifi ce NG 593-528
Pilot Orifi ce LP 593-527
Regulator NGNGK-DXV
Regulator LPLPK-DXV
Blower with Rheostat
Remote Control
Wall Thermostat
Wall Switch Kit (Off white)
Wall Switch Kit (White)
Rear Vent Conversion Kit
Front Glass
Standard Hearth Pad
Touch Up Paint (Pewter)
Pre May 2008SRV-PAL-TR
Post May 2008PAL-TR
BronzePAL-GLS-BZ
GreenPAL-GLS-GR
SmokePAL-GLS-GY
BronzeHP-PAL-BZ
GreenHP-PAL-GR
SmokeHP-PAL-GY
GFK-160A
RCT-MLT-HNG
WH-STAT
WSK-21
WSK-21-W
TUPP-12
Y
Y
Y
Y
Y
Y
Valve assembly part numbers appear on following page.
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0858
Page 59
E. Service Parts
PALOMA
Bottom Plate Assembly
Valve Diagram
1
2
3
4
5
6
7
Beginning Manufacturing Date: July 2005
Ending Manufacturing Date: ______
11
10
8
9
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
F. Limited Lifetime Warranty
Hearth & Home Technologies LIMITED WARRANTY
Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet
and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada.
Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
Warranty PeriodHHT Manufactured Appliances and Venting
PartsLaborGasWoodPellet
1 YearXXXXXX
EPA
Wood
ElectricVenting
Components Covered
All Parts and Material Except as
covered by Conditions, Exclusion,
and Limitations listed
XX
2 years
3 yearsXFirepots
5 years3 yearsXXCastings & Baffl es
7 years3 yearsXXX
10 years1 yearXBurners, Logs & Refractory
Limited
Lifetime
1 yearXFirebox & Heat Exchanger
90 DaysXXXXXX All Replacement Parts
XXXXBlowers
XMolded Refractory Panels
Igniters, Electronic Components,
and Glass
Firebox, HHT Chimney,
Termination & Heat
Exchanger
See Conditions, Exclusions, and limitations. 9-01-08
CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY
• This warranty applies to the original owner and is transferable up to two years from date of purchase to the new homeowner,
provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance remains in its
original place of installation.
• The maximum amount recoverable under this warranty is limited to the purchase price of the product.
• In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.
• Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is
not covered under this warranty.
Page 1 of 24021-645A 09-01-08
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0860
Page 61
F. Limited Lifetime Warranty (continued)
• This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass
gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion
on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this
warranty.
• Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this
noise are not covered by this warranty.
• HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance
of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identifi cation
label furnished with the appliance; (2) installation which does not comply with local building codes; (3) shipping, improper
handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate
ventilation or drafting caused by tight sealing construction of the structure or handling devices such as exhaust fans or forced
air furnaces or other such causes; (5) use of fuels other than those specifi ed in the operating instructions; (6) installation
or use of components not supplied with the appliance or any other components not expressly authorized and approved
by HHT; and/or (7) modifi cation of the appliance not expressly authorized and approved by HHT in writing.
• This warranty does not apply to non-HHT venting components, hearth components or other accessories used in conjunction
with the installation of this product.
• This warranty is void if the appliance has been over-fi red or operated in atmospheres contaminated by chlorine, fl uorine,
or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or there is any
damage to the appliance or other components due to water or weather damage which is the result of, but not limited to,
improper chimney or venting installation.
• HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship during
the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the defective
component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.
• Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not
apply to you. This warranty gives you specifi c rights; you may also have other rights, which vary from state to state.
• EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE
WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF
THE WARRANTY SPECIFIED ABOVE.
This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all
warranties currently in existence.
If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary
parts or components, contact the nearest authorized HHT dealer or supplier.
Page 2 of 24021-645A 09-01-08
Heat & Glo • Paloma • 7031-220 Rev. P • 10/0861
Page 62
G. Contact Information
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
www.heatnglo.com
Please contact your Heat & Glo dealer with any questions or concerns.
For the location of your nearest Heat & Glo dealer,