Models: Dakota 42-B Dakota 42H-B
DO NOT DISCARD THIS MANUAL
CAUTION
Rea d , understand an d f o ll ow th e se instructions for safe i n s t a l l a t i o n a n d operation.
L e a v e t h i s manual with party responsible for use and operation.
Owner’s Manual
Installation and Operation
WARNING
If the information in these instruc­tions is not followed exactly, a
re may result causing property damage, personal injury, or death.
• Do not store or use gasoline or other am
mable vapors and liquids in the vicinity of this or any other appliance.
• What to do if you smell gas:
- Do
not try to light any appliance.
- Do not touch any electrical switch. Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
• Installation and service must be performed
by a qualied installer, service agency, or
the gas supplier.
-
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as appliance.
• A l er t c h i l d re n a n d a du l t s t o h a z ar ds o f h ig h temperatures.
High temperatures may ignite clothing or other ammable materials.
• Keep clothing, furniture, draperies and other combustibles away.
This appliance must be installed outside.
Note: An arrow () found in the text signies change in
content.
Installation and service of this appliance should
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 1
be performed by qualied personnel. Hearth & Home Technologies suggests NFI certied or
factory-trained professionals, or technicians supervised by an NFI
certied professional.
Read this manual before installing or operating this appliance.
This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1 in the USA installation codes.
ANSI Z21.50-2003 - CSA 2.22-M2003
Serial (Serie):
Mfg. Date:
Vented gas fireplace - for outdoor installation only. Not for use with solid fuel. (Foyer au
gaz à évacuati on - p our install ation à l'extérie ur seulemen t. Ne doit pa s entre utilise avec un combustible solide.)
Minimum Permissible Gas Supply for Purposes of Input Adjustment. Natural Gas Propane Gas Approved Minimum (De Gaz) Acceptable . . 7.0 in. w.c. (Po. Col. d'eau) . . .11.0 in. w.c. (Po. Col. d'eau)
Maximum Pressure (Pression) . . . . . . . . . . 10.0 in. w.c. (Po. Col. d'eau) . .14.0 in. w.c. (Po. Col. d'eau)
Maximum Input BTUH: . . . . . . . . . . . . . . . . 60,000 . . . . . . . . . . . . . . . . . . . 53,000
Orifice Size: . . . . . . . . . . . . . . . . . . . . . . . . #25DMS . . . . . . . . . . . . . . . . . .#44DMS
This product is covered by one or more of the following patents: (Nos produits sont couverts par un ou plusieurs des brevels suivants): (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254; 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending (ou autres brevets americains et etrangers en attente).
DAKOTA42-B
DAKOTA42L-B
4036-994A
MADE
IN USA
Model (Modele):
VENTED GAS
FIREPLACE
8R54
Outdoor Lifestyles by Hearth & Home Technologies Inc. 7571 - 215th St. West., Lakeville, MN 55044
OD
Please retain this owner’s manual for future reference.
Congratulations
Congratulations on selecting a Heat & Glo LifeStyle Collection gas appliance—an elegant and clean alternative to wood burning appliances. The Heat & Glo LifeStyle Collection gas appliance you have selected is designed to provide the utmost
in safety, reliability, and efciency.
As the owner of a new appliance, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.
This owner’s manual should be retained for future reference. We suggest you keep it with your other important documents and product manuals.
The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.
Your new Heat & Glo LifeStyle Collection gas appliance will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo LifeStyle Collection family of appliance products!
We recommend that you record the following pertinent
Homeowner Reference Information
information about your appliance:
Model Name: Date purchased/installed:
Serial Number: Location on appliance:
Dealership purchased from: Dealer phone:
Notes:
Listing Label Information/Location
The model information regarding your specic appliance can be found on the rating plate usually located in the control area
of the appliance.
Type of Gas
Gas and Electric Information
Serial Number
Model Number
2 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
Table of Contents
1 Listing and Code Approvals
A. Appliance Certication . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Specications C. BTU Specications
D. High Altitude Installations
. . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . . 4
2 Getting Started
A. Design and Installation Considerations . . . . . . . . . . . . 5
Moisture Resistance: B. Tools and Supplies Needed C. Inspect Appliance and Components
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
. . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . 6
3 Framing and Clearances
A. Select Appliance Location . . . . . . . . . . . . . . . . . . . . . . 7
B. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
C. Mantel Projections
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 Termination Locations
A. Vent Termination Minimum Clearances . . . . . . . . . . . . 9
5 Appliance Preparation
A. Remove Logs and Shipping Cover . . . . . . . . . . . . . . 10
B. Securing and Leveling Appliance
. . . . . . . . . . . . . . . 10
6 Gas Information
A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
B. Gas Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C. Gas Connection D. High Altitude Installations E. Valve Access
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
. . . . . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
7 Electrical Information
A. Intellire Ignition System Wiring . . . . . . . . . . . . . . . .14
8 Finishing
A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
B. Facing Material
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
9 Appliance Setup
A. Clean the Appliance. . . . . . . . . . . . . . . . . . . . . . . . . .17
B. Grate Assembly Placement C. Positioning the Logs D. Glass Assembly E. Placing Lava Rock F. Reinstall Door Lock
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
. . . . . . . . . . . . . . . . . . . . . . . . . . . 19
. . . . . . . . . . . . . . . . . . . . . . . . . .19
. . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . . . . . . 17
10 Operating Instructions
A. Before Lighting Appliance . . . . . . . . . . . . . . . . . . . . . 20
B. Lighting the Appliance C. After the Appliance is Lit D. Frequently Asked Questions
. . . . . . . . . . . . . . . . . . . . . . . .21
. . . . . . . . . . . . . . . . . . . . . . 22
11 Troubleshooting
A. Intellire Ignition System . . . . . . . . . . . . . . . . . . . . . . 23
12 Maintaining and Servicing the Appliance
A. Valve Service and Replacement . . . . . . . . . . . . . . . .25
B. Battery Replacement B. Maintenance and Service Tasks:
. . . . . . . . . . . . . . . . . . . . . . . . . 26
13 Reference Materials
A. Appliance Dimension Diagram . . . . . . . . . . . . . . . . . 28
B. Service Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
C. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
D. Contact Information
. . . . . . . . . . . . . . . . . . . . . . . . . . 36
. . . . . . . . . . . . . . . . . . . 22
. . . . . . . . . . . . . . . . 27
29
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 3
Listing and Code Approvals
1
A. Appliance Certication
MODELS: Dakota 42-B, Dakota 42H-B LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Appliance STANDARD: ANSI Z21.50-2003—CSA2.22-M2003
This product is listed to ANSI standards for “Vented Gas Fireplaces” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehi­cles”, and “Gas Fired Appliances for Use at High Altitudes”.
B. Glass Specications
Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such
as bathtub enclosures as dened by the Consumer Product
Safety Commission (CPSC). The tempered glass has been
tested and certied to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certication Council
SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Section
1201.5 “Certication and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certicate shall
accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.
C. BTU Specications
Maximum
Models
Dakota 42-B (NG) 60,000 25
Dakota 42-B (LP)
Input BTUH
53,000 44
Orice Size
(DMS)
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang-
ing the existing burner orice to a smaller size. Input rate
should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop-
er orice size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under
water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
4 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
Getting Started
2
A. Design and Installation Considerations
These appliances must be installed outdoors.
The Dakota 42-B Series outdoor gas replace is designed
for outdoor use. It may also be installed in screened porches and lanais that meet these minimum requirements:
• Minimum porch area - 96 square feet
• Minimum ceiling height - 84 in.
A minimum of two walls can be screened but must be open to outside ventilation.
• Minimum screen area - 64 square feet
• Minimum screen top height - 80 in.
Refer to Section 3.B. for clearances.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national codes and regulations.
• Consult insurance carrier, local building, fire
ofcials or authorities having jurisdiction about
restrictions, installation inspection, and permits.
When planning an appliance installation, it’s necessary to determine the following information before installing:
• Where the appliance is to be installed.
• Gas supply piping.
• Electrical wiring.
• Framing and nishing details.
Moisture Resistance:
This outdoor replace will shed moderate amounts of water,
but is not waterproof. Water and condensing water vapor may enter the chase under certain conditions.
The replace will not perform as an exterior wall. Moisture
penetration must be considered for construction that places the replace in structure walls or on moisture sensitive sur­faces.
When installed on exterior walls: Hearth & Home Tech­nologies recommends that the replace chase be con­structed outside the structure’s weather envelope. Where
the platform meets the wall, use a ashing detail similar to
that required for attached decks. Chase platforms, including hearths should slope away from the structure at 1/8 in. to
1/4 in. per foot. The replace can be shimmed level.
When installed on surfaces where water may collect or
cause damage: Hearth & Home Technologies recommends that a drainage pan be placed under the unit. This can be constructed of metal, adhesive polymer membrane (such as ice and water shield) or other suitable materials. A means of drainage out of the pan such as tubes or weep holes should be provided. A slope of 1/8 in. to 1/4 in. per foot towards
the drain port is suggested. The replace can be shimmed
level.
Hearths should slope away from the front of the replace
and chase at 1/8 in. to 1/4 in. per foot. Spark strips must be on top of any combustible hearth materials used for moisture management.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 5
B. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Reciprocating saw Framing material Pliers Hi temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits (1/4 in.) Plumb line Safety glasses Manometer Voltmeter Tape measure Level Non-corrosive leak check solution 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
C. Inspect Appliance and Components
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
• Carefully remove the appliance and components from the packaging.
• The gas logs may be packaged separately and must be
eld installed.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
• Read all of the instructions before starting the
installation. Follow these instructions carefully
during the installation to ensure maximum safety and benet.
WARNING
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent system component.
• Modication of the appliance or vent system.
• Installation other than as instructed by Hearth & Home Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a re hazard.
6 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
B
A
G
E
Note: If this surface is inside the building’s warm air envelope...
...then this surface must be an exterior wall system.
C
D
F
F
C
D
G
F
E
57-3/4 in.
(1467 mm)
81-3/4 in.
(2076 mm)
Framing and Clearances
3
Note:
• Illustrations reect typical installations and are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design preference.
A. Select Appliance Location
When selecting a location for your appliance it is important to consider the required clearances to walls (See Figure 3.1).
No t e: For actual applianc e dimensions refer to Section 13.
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings.
• To combustibles.
• For service access.
Locate appliance away from trafc areas.
Figure 3.1 Appliance Locations
WARNING
Fire Risk Odor Risk
• Install appliance on hard metal or wood surfaces extending full width and depth of appliance.
• Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.
in. 24-3/4 24-1/8 48 49 5/8 1/2 1-1/2
mm 629 613 1219 1245 16 13 38
A B C D E F G
WARNING
Fire Risk
• Lo c ate and i nstall a ppliance to all
clearance specications in manual.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 7
Fireplace Structure
Mantel
B
A
If A is:
Then
B
must be at
least:
in.
6 - 36 26
mm
152 - 914 660
in.
36 or more
18
mm
914 or more 457
84 in.
(2134 mm)
minimum
height
Additional Structure
or Sidewall
Roof or
Overhang
12 in. (305 mm) max. combustible mantel depth
B. Clearances
B
D Header height. Use only noncombustible material below the top of the top standoffs.
A
C
84 in.
(2134 mm)
to ceiling
0 in.
0 in. to level of standoffs
Combustible Object
36 in.
(914 mm)
Combustible flooring may be installed next to the front of the appliance.
1-1/2 in. (38 mm)
Drywall
0 in.
1/2 in. (13 mm)
1-1/2 in. (38 mm)
Upper front can be covered with non-combustible material or removed and replaced with non-combustible material.
Framing Dimensions
A B C D
in. 24-1/8 43-7/8 49 43-7/8
mm 613 1114 1245 1114
Figure 3.2 Framing Dimensions
C. Mantel Projections
8 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
WARNING
Fire Risk
• Comply with all minimum clearances to combustibles
as specied.
• Fr a m i n g o r f i n i s h i n g mat e ria l use d on t h e front of, or in front of, the appliance closer than the mi nimums lis ted, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause
re.
Figure 3.3 Clearances to Mantels or Other Combustibles Above Appliance
FP
= FIREPLACE OPENING
X
= AIR SUPP LY INLET
= AREA WHERE FIREPLACE IS NOT PERMITTED
O
N
P
R
Q
FP
(See Note 2)
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
Q
MIN
R
MAX
Dakota 10 feet 2 x Q
ACTUAL
1 additional termination cap Q + 3 feet 1 x Q
ACTUAL
2 additional termination caps Q + 6 feet 2/3 x Q
ACTUAL
3 additional termination caps Q + 9 feet 1/2 x Q
ACTUAL
R
MAX
= (2 / # caps plus fireplace ) x Q
ACTUAL
D
E
L
FP
A
H
M
X
J or K
I
A
G
F
FP
FP
FP
FP
FP
B
B
B
A = 0 in. . . . . . . . . . clearances above grade,
veranda, porch, deck or balcony.
B = 12 in. . . . . . . . . . clearances to window or door
that may be opened, or to
permanently closed window.
36 in. . . . . . . . . . vinyl windows or siding.
D** = 47 in. . . . . . . . . . vertical clearance to unventi-
lated soffit or to ventilated soffit
located above the terminal.
60 in. . . . . . . . . . vinyl clad soffits.
F = 9 in. . . . . . . . . . clearance to outside corner.
G* = 6 in. . . . . . . . . . clearance to inside corner.
48 in. . . . . . . . . . vinyl windows or siding.
H = 3 ft. (Canada) . not to be installed above a gas
meter/regulator assembly within
3 ft (914 mm) horizontally from
the center line of the regulator. I = 3 ft. (USA) 6 ft. (Canada) . clearance to service regulator
vent outlet and electric service.
J = 9 in. (USA) 12 in. (Canada) . clearance to non-mechanical air
supply inlet to building or the combustion air inlet to any other
appliance. K = 3 ft. (USA) 6 ft. (Canada) . clearance to a mechanical air
supply inlet.
L*** = 54 in. . . . . . . . . . clearance above paved sidewalk
(See note 1) or a paved driveway located on
public property.
M**** = 47 in. . . . . . . . . . clearance under veranda, porch,
deck, balcony or overhang.
Not allowed: . . . . . . vinyl
N = 6 in. . . . . . . . . . non-vinyl siding.
P = 84 in.
* 48 in. minimum for vinyl windows or vinyl siding. ** Not allowed for vinyl clad soffits. *** a fireplace shall not open directly above a sidewalk or paved
driveway which is located between two single family dwellings and services both dwellings.
**** only permitted if veranda, porch, deck or balcony is fully open
on a minimum of 2 sides beneath the floor, or if the screened porch guidelines are followed.
Note 1: Local codes or regulations may require different clearances. Note 2: Termination in an alcove space (spaces open only on one
side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1) There must be a 3 ft minimum between terminations or between the fireplace and termination. 2) All mechanical air intakes within 10 ft of a termination must be a minimum of 3 ft below the fireplace hood. 3) All gravity air intakes within 3 ft of the fireplace hood must be a minimum of 1 ft below the termination.
This fireplace is approved for installation onto screen porches with the following guidelines:
Minimum porch area: 96 sq ft Minimum ceiling height: 84 in. Minimum of two walls must be screened Minimum top of screen height, side walls: 6 ft 8 in. Minimum screen area: 64 sq ft
Note 2: There may be some odor and small amounts of soot associated with burning the Dakota on a screened porch. Ensuring good cross draft ventilation and routine maintenance of the fireplace will maximize comfort and cleanliness.
Termination Locations
4
A. Vent Termination Minimum Clearances
Figure 4.1 Minimum Clearances
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 9
Appliance Preparation
Open Open
Locking Screw
NAILING TABS
Upper front can be covered with non-combustible material or removed and replaced with non-combustible material.
5
CAUTION
B. Securing and Leveling Appliance
Sharp Edges
• We a r protective gl o v e s and safety glasses during installation.
A. Remove Logs and Shipping Cover
Remove locking screw at the top of the doors (shown in Fig­ure 5.1).
Open the doors by sliding the handles toward the outside edges of the doors. Remove the cartons of logs from their shipping location in the appliance.
Set the logs and door lock bracket screw aside for later re­installation.
WARNING
Fire Risk
• Prevent contact with sagging, loose insulation.
• Do NOT install against vapor barriers or exposed insulation.
The diagram shows how to properly position, level, and se­cure the appliance (see Figure 5.2). Nailing tabs are pro­vided to secure the appliance to the framing members.
• Place the appliance into position on either a combustible
or non-combustible continuous at surface.
Note: Remove the top standoffs before sliding appliance
into position if using an FPS prefab enclosure.
• Level the appliance from side to side and front to back.
• Shim the appliance with non-combustible material, such as sheet metal, as necessary.
• Bend out nailing tabs on each side.
• Keep nailing tabs ush with the framing.
• Secure the appliance to the framing by using nails or screws through the nailing tabs.
Figure 5.1 Door Operation
Figure 5.2 Proper Positioning, Leveling and Securing of an
Appliance
CAUTION
Do NOT notch into the framing around the appliance
10 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
spacers.
Gas Information
6
A. Fuel Conversion
Before making gas connections ensure appliance being in­stalled is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali-
ed technician using Hearth & Home Technologies specied
and approved parts.
B. Gas Pressure
Proper input pressures are required for optimum appliance performance. Gas line sizing requirements need to be made following NFPA51.
WARNING
Fire Risk Explosion Risk
High pressure will damage valve.
• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.
• Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.
C. Gas Connection
Note: Have the gas supply line installed in accordance with loc al building codes, if any. If not, follow ANSI
223.1. Installation should be done by a qualied installer
approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.)
Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and exible gas connector are connected to the 1/2 in.
(13 mm) control valve inlet.
• If substituting for these components, please consult
local codes for compliance.
Optional: A 5 ft exible gas line is available to those regions
which do not require black pipe to be used. See Service Parts List (Section 13).
Note: Gas line MUST be run from right side of appliance.
WARNING
Fire Risk Explosion Risk
Verify inlet pressures.
• Hi g h pr e ss u r e m ay ca u s e o v e r fi re condition.
• Low pressure may cause explosion.
Install regulator upstream of valve if line pressure is greater than 1/2 psig.
Pressure requirements for appliance are shown in table below.
Pressure Natural Gas Propane
Minimum Inlet Pressure 5.0 inches w.c. 11.0 inches w.c.
Maximum Inlet Pressure 7.0 inches w.c. 14.0 inches w.c.
Manifold Pressure 3.5 inches w.c. 10.5 inches w.c.
These pressures can be veried through the internal valve
access panels as shown in Section E. Valve Access.
WARNING
Gas Leak Risk
• Support control when attaching pipe to prevent bending gas line.
Note: The gap between supply piping and gas access hole may be plugged with non-combustible unfaced insulation
to prevent cold air inltration.
• Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.
• Incoming gas line s hould be piped into the valve compartment and connected to the 1/2 in. connection on the manual shutoff valve.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 11