Hearth and Home Technologies CR36D, CL36D User Manual

CL36D and CR36D
WOODBURNING FIREPLACE
INSTALLATION & OPERATING
INSTRUCTIONS
WARNING!
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.
02-02 1 12538 Rev D
CL36D AND CR36D INSTALLATION INSTRUCTIONS
Table of Contents
Design and Installation Considerations ........................................................................................... 3
A. Listings and Code Approvals .......................................................................................................... 4
B. Description of the Fireplace System .............................................................................................. 4
C. Fireplace System Components ...................................................................................................... 5
D. Pre-Installation Preparation .......................................................................................................... 10
E. Chimney Requirements................................................................................................................ 12
F. Installation of Fireplace ................................................................................................................ 15
G. Constructing a Chase .................................................................................................................. 22
H. Operating Instructions .................................................................................................................. 25
I. Maintenance Instructions ............................................................................................................. 29
Index ........................................................................................................................................... 31
Warranty ...................................................................................................................................... 32
CAUTION:
Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insulation will produce an odor when the fireplace is used.
SAFETY PRECAUTIONS
1. Please read these installation instructions completely
before beginning installation procedures. Failure to follow them could cause a fireplace malfunction resulting in serious injury and/or property damage.
2. Always check your local building codes prior to
installation. The fireplace installation must comply with all local, regional, state and national codes and regulations.
3. An adequate supply of replacement combustion air
from outside the house must be available to the fire for the fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.
In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required to support combustion. Hearth Technologies Inc. is not responsible for any smoking or related problems that may result from the lack of adequate combustion air. It is the responsibility of the builder/ contractor to ensure that adequate combustion air has been provided for the fireplace.
4. This fireplace must be installed with the Hearth
Technologies Inc. (HTI) SL Series Chimney System.
The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given in these installation instructions.
5. NEVER leave children unattended when there is a fire
burning in the fireplace.
6. This woodburning fireplace is built for solid fuel only. NEVER use gasoline, gasoline type lantern fuel,
kerosene, charcoal lighter fluid, or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.
7. DO NOT use chimney cleaners or flame colorants in your fireplace.
8. The flue damper must be open at all times when the fireplace is in use.
9. While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric shock or burns. Also, make sure the fireplace is completely cooled before servicing.
10. To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace and chimney prior to use and periodically during the burning season. See page 29 for cleaning instructions.
CL36D AND CR36D INSTALLATION INSTRUCTIONS
DESIGN AND INSTALLATION CONSIDERATIONS
When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly. This may result in smoke spillage from your fireplace, as well as cause other combustion appliances to operate incorrectly.
Tightly sealed construction is important for energy efficiency. Unfortunately, a great deal of effort has been directed to tightening up sidewall construction, while considerably less attention has been paid to tightening upper portions of the warm air envelope (insulated ceilings). This has increased the Stack Effect, a condition that increases the negative pressure generated by the structure. This negative pressure will directly affect the drafting performance of a fireplace chimney. To minimize the negative pressure generated by stack effect, make certain that all ductwork installed in the attic spaces is sealed airtight. Minimize the number of recessed light fixtures installed in the insulated ceiling, and use sealed recessed light fixtures. Finally, make certain the whole house fans and attic access panels are tightly sealed. These are important design considerations that must be observed during the design and construction stage of the home.
If you desire to put a fireplace in your basement, we recommend that you consider a direct vent gas fireplace. Basements always have a significant negative air pressure that causes the fireplace system to be more susceptible to smoke spillage and cold flue backdrafting. Since direct vent gas fireplaces are sealed, they are not affected by the negative pressure that exists in basements.
Finally, woodburning fireplaces perform best when their chimney (roof termination) is located on the upper half of the roof, especially when cathedral ceilings are present. Chimneys that are located on the lower half of the roof realize what is known as lazy flue and will not draft as well as a chimney that is located in the upper portion of the roof. The reason for this is that the stack effect generated by the overall height of the living spaces inside the house will exceed the draft generated by the chimney system. If you desire to place a woodburning fireplace in a location where the termination cap would be located on the lower half of a roof, such as on an outside wall at the base of a cathedral ceiling, we recommend that you consider using a direct vent gas fireplace. This will assure the homeowner a fireplace that operates correctly.
These properties do not affect just your woodburning factory built fireplace. They can cause any woodburning fireplace as well as any conventionally vented (B-vent) gas appliance to operate improperly. Careful planning at this stage of your project will ensure satisfaction with the operation of your fireplace once it is completed.
02-02 3 12538 Rev D
CL36D AND CR36D INSTALLATION INSTRUCTIONS
A. LISTINGS AND CODE APPROVALS
This fireplace system has been tested and listed in accordance with UL 127 standards, and has been listed by Underwriters Laboratories Inc. for installation and operation in the United States and Canada.
This fireplace has been tested and listed for use with the optional components listed on page 5. These optional components may be purchased separately and installed at a later date. However, installation of an outside air kit will require significant reconstruction, and should be installed at the time of the initial fireplace installation.
Check with your local building code agency prior to installing this fireplace to ensure compliance with local codes, including the need for permits and follow-up inspections. If you need assistance during installation, please contact your local dealer or the Heatilator Technical Services Department, Hearth Technologies Inc., 1915 W. Saunders St., Mt. Pleasant, Iowa 52641 (1-800-843-2848).
Heatilator® is a registered trademark of Hearth Technologies Inc., Division, HON INDUSTRIES.
WARNING!
This fireplace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit­ers Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read through these instructions thoroughly before starting your installation and follow them carefully throughout your project.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
1. The Heatilator fireplace system consists of the following: a. Fireplace/Integral Grate/Outside Combustion Air System b. Refractory c. Chimney Termination Cap d. Chimney System e. Hearth Extension
2. Optional Components Include: a. Glass Doors b. Chimney Air Kit
Note: Illustrations used throughout these instructions
reflect typical installations and are for design purposes only. Actual installation may vary slightly due to indi­vidual design preferences. However, minimum and maxi­mum clearances must be maintained at all times.
The illustrations and diagrams used throughout these installation instructions are not drawn to scale.
Figure 1 - Typical Fireplace System
CL36D AND CR36D INSTALLATION INSTRUCTIONS
C. SYSTEM COMPONENTS
1. Fireplace Components
#golataC:noitpircseD
D63RC/D63LCspirtSnoitcetorPhtraeHdnaetarGlargetnIhtiw,ecalperiF
6341MDkcalB-weiV-raelC,dlof-iB-srooDssalG
B6341MDssarBdehsiloP-weiV-raelC,dlof-iB-srooDssalG S6341MDleetSsselniatS-weiV-raelC,dlof-iB-srooDssalG
6341PDkcalB-detniT-srooDssalG
B6341PDssarBdehsiloP-detniT-srooDssalG S6341PDleetSsselniatS-detniT-srooDssalG 6341EPDlenaPdnE-srooDssalG
B6341EPDssarBdehsiloP-lenaPdnE-srooDssalG S6341EPDleetSsselniatS-lenaPdnE-srooDssalG
3XHnoisnetxEhtraeH
R3RG/L3RG)ecalperiFhtiwdedulcni(etarGlargetnI
41KA)ecalperiFhtiwdedulcni(tiKriAedistuO
Bi-Fold Glass Doors
DM1436 DM1436B DM1436S
GR3L/GR3R Integral
Grate
02-02 5 12538 Rev D
Perception Glass Doors
DP1436 DP1436B DP1436S
Perception Glass Door
End Panel
DPE1436 DPE1436B DPE1436S
HX3 - Hearth Extension
CL36D AND CR36D INSTALLATION INSTRUCTIONS
Fireplace Dimensions
AK14 - Outside Air Kit
CL36D AND CR36D INSTALLATION INSTRUCTIONS
2. Chimney Components
The following pictures show only those chimney components which may be safely used with this fireplace.
#golataC:noitpircseD
A4KACtiKriAyenmihC
4DIriAedistuO/tcuDdetalusnI
4DUriAedistuO/tcuDdetalusninU
603LSgnol"6-noitceSyenmihC 213LSgnol"21-noitceSyenmihC 813LSgnol"81-noitceSyenmihC 423LSgnol"42-noitceSyenmihC 633LSgnol"63-noitceSyenmihC 843LSgnol"84-noitceSyenmihC
3LSrezilibatSyenmihC
513L51-nruteR/tesffOyenmihC 033L03-nruteR/tesffOyenmihC 833SF 933S51-potseriF 043S03-potseriF
8SAdleihSnoitalusnIcittAthgiartS
778BJdnaBtnioJyenmihC
678BCtekcarByenmihC
073FRhctiP21/6ottalF-gnihsalFfooR
173FRhctiP21/21ot21/6-gnihsalFfooR 443RTpaCnoitanimreTdnuoR 243RTpaCnoitanimreTgnipocseleTdnuoR 573TSpaCnoitanimreTerauqS 543STpaCnoitanimreTerauqS
P543STdetniaP-paCnoitanimreTerauqS
53TCpoTesahC
33SDL'3x'3-duorhSevitaroceD
64SDL'6x'4-duorhSevitaroceD
thgiartS-potseriF
02-02 7 12538 Rev D
Chimney Sections
#golataCAB
603LS"6"¾4 213LS"21"¾01 813LS"81"¾61 423LS"42"¾22 633LS"63"¾43 843LS"84"¾64
=AhtgnellautcA =Bfohtgnel(htgnelevitceffE
CL36D AND CR36D INSTALLATION INSTRUCTIONS
SL3 - Chimney Stabilizer
sahtiretfatrapyenmihc
)rehtonaotdeppansneeb
Offset/Return
#golataCA
513L51
033L03
Firestop Spacer
#golataCAB
833S0"½41 933S5181 043S03"32
CB876
Chimney Bracket
RF370 - Roof Flashing
Flat to 6/12 Pitch
3
/8"
JB877
Joint Band
RF371 - Roof Flashing
6/12 to 12/12 Pitch
AS8
Straight Attic
Insulation Shield
CL36D AND CR36D INSTALLATION INSTRUCTIONS
LDS33 (3 x 3) LDS46 (4 x 6)
Decorative Shroud
ST375
Square
Termination Cap
TR344 Round
Termination Cap
TS345/TS345P
Square
Termination Cap
TR342
Round Telescoping
Termination Cap
CT35
Chase Top
02-02 9 12538 Rev D
CAK4A
Chimney Air Kit
CL36D AND CR36D INSTALLATION INSTRUCTIONS
WARNING!
To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers or exposed insulation. Localized overheating could occur and a fire could result.
D. PRE-INSTALLATION PREPARATION
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the fireplace. Consideration should be given to these factors before deciding on a location.
CLEARANCES!
A minimum ½ air clearance must be maintained at the back and side of the fireplace assembly.
Chimney sections at any level require a 2 minimum air space clearance between the framing and chimney section.
Figure 2 - Fireplace Locations
Figure 3 shows a typical installations assuming an outside air kit is being used. Therefore, an allowance must be made for 90° bends. Less space is required when ducting goes directly outside without forming elbows.
These are rough framing
dimensions only.
htiW
riAedistuO
"44=A63=A
Figure 3
Installation Along a Wall or an Exterior Chase
tuohtiW
riAedistuO
5
/8"
WARNING!
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous. Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the
roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will reduce the possibility of fireplace smoking or air flow reversal.