OmniLogic
6 Easy
Wireless Terminal
QUICK START GUIDE
Steps
Charge the
Wireless
Terminal
Check latest
MSP Firmware
Version
Upgrade MSP
if Necessary
Connect to
Home Wireless
Network
Check latest
Wireless Terminal
Firmware Version
Upgrade
Wireless Terminal
if Necessary
Step 1 Step 2 Step 3
Charge the Wireless Terminal Check MSP Firmware Version Check Latest Firmware
v
MSP version is displayed
SPA
º
F
themes
cong wizard
system info
backup cong
restore cong
SYSTEM
conguration
msp id:3233
component HUA version
MSP
MP
Relays
VSP
Wired Wall Mo..
display
network
web server
date/time
00-46-01-21-a0
1-65-0-2a-d4
3-10-0-0-1
10-0-0-0-4e
33-41-1-e7-42
1 / 2
R 2.0.1
R 1.0.2
R 1.0.2
R 3.0.4
R.2.0.0
90
The following steps should be performed ONLY with the Wireless Terminal
placed in the charging cradle, or after charging for at least 8 hours. If a rmware upgrade is needed, it must be completed while in the charging cradle.
NOTE: The Wireless Terminal will take 12 seconds to reboot when placed in
the charging cradle if the battery is fully discharged.
71º F
air
Before connecting the Wireless Terminal to the OmniLogic system, verify
that you have the latest OmniLogic MSP rmware version. The rmware
version displayed in “System Info” should be the same as the latest version
available for download on the web. Follow the screens above to locate your
MSP rmware version and go to Step 3 to nd the latest rmware version
on the web.
cong
A list of all the latest rmware versions available for download appear. Note
the rmware version located in the “Local MSP” box. If the version matches
your current version located in Step 2, then move on to Step 4. If not, then
go to Side B of this sheet to perform a rmware upgrade of your MSP.
Version on the Web
To nd the latest available rmware
version, go to www.hayward.com/
rmware and select “OmniLogic”
from the “Select Product” dropdown menu and “HLBASE” from
the “Select SKU” drop-down menu.
Select the “Firmware Updates” tab.
Step 4 Step 5 Step 6
With the latest MSP version loaded to your OmniLogic, Touch “OK” at the
welcome screen below from your Wireless Terminal to enter the wireless
conguration screen.
NOTE: This following procedure assumes that your OmniLogic system is
already connected to your home wireless network.
Go to “Wireless” Menu Connect To Home
Wireless Network
The wireless conguration screen will display all available wi networks. Select the desired network from the list and input your password on the screen
as shown below. Press the check mark to save your selection. Your Wireless
Terminal is now congured to your home wireless network and will automat-
ically pair with your OmniLogic system.
Now that your Wireless Terminal is connected to the OmniLogic system,
the nal step is to verify that the rmware version of the Wireless Terminal
matches that of the MSP.
To nd the current rmware version of the Wireless Terminal, go to the OmniLogic and follow the same screens shown in Step 2. Then go to the web-
site (Step 3) and verify that the latest rmware version matches that of your
Wireless Terminal (shown as “Wi- Term” in the list below). If they match,
congratulations, you are nished conguring your Wireless Terminal to your
OmniLogic. If they do NOT match, follow the steps on Side B of this sheet to
perform a rmware upgrade to your Wireless Terminal. The unit must be in
the charging cradle when performing a rmware upgrade.
msp id:3233
component HUA version
MSP
MP
Relays
VSP
Wi-fi Term
00-46-01-21-a0
Welcome to the Hayward Wireless Remote
Press OK to setup your new remote.
configuration
OK
NOTE: The Wireless Terminal will
only connect to an OmniLogic that
is on the same network.
en
ON
Smith Home Wifi
q
w
a
ABC
.?123
Please enter [yourwifi] network password
Network Connections dynamic
WIRELESS
connection
password
def g
xyz
space
hij k l
bc
v
o prst u
mn
←
1-65-0-2a-d4
3-10-0-0-1
10-0-0-0-4e
33-41-1-e7-42
Check Wireless Terminal
Firmware Version
R 3.0.0
R 1.0.2
R 1.0.2
R 3.0.4
R 3.0.0
MSP rmware version
Wireless Terminal rmware
version
Side A
If a rmware upgrade to your MSP or Wireless Terminal is required...
daylight favorites
alarm lights
º
F
air
71º F
82
daylight
sysinfo
upgrade
cong
Step 1 Step 2 Step 3
WARNING - Inserting and removing the USB thumb drive requires removal of the front panel. Verify that all power is removed to the OmniLogic system before removing the front panel.
From your computer: To begin upgrading your MSP or your Wireless Ter-
minal (they should have same rmware version), navigate to the website as
shown in Step 3 on Side A of this sheet. Insert your USB thumb drive (not
Download Latest
Firmware Version
Verify that power is removed to the OmniLogic system and remove the front
panel. Insert the USB drive into the side of the MSP.
Replace the front panel and then power on the OmniLogic system. When
the system nishes powering back on, enter Service Mode by following the
screens below.
Insert USB into the MSP
and Enter Service Mode
Follow the screens below to begin the upgrade for the device.
included) into the computer. Click on the orange download button located in
the box of the component that you are upgrading. Save the rmware le to the
USB drive. Download the “Wired Terminal” rmware shown below (Wired and
Wireless Terminals use the same rmware).
When Upgrading your MSP (Step 3, Side A), select:
When Upgrading your Wireless Terminal (Step 6, Side A), select:
NOTE: It is best if you download the rmware in Chrome, Firefox or Safari
browsers. If you download in Internet Explorer, once your download is complete, please remove the “.TXT” extension from the le on the USB drive.
service
mode
shut down
features
simple
o
mode
NOTE: Do not choose Timed Service Mode when upgrading a device. If you
DO choose Timed Service Mode, be sure to dedicate enough time so that the
upgrade will have time to nish. Upgrading a Wireless Terminal can take a
few minutes.
Press “Upgrade” button in Service Mode menu
component HUA current version
MSP 00-46-01-21-a0 R 1.5.0
MP 1-65-0-2a-a6 R 1.0.4
Wifi Term 33-41-1-e7-42 R 2.0.0
COMPONENT
selection
Press the check mark Press “USB” to view the rm-
select device
Press Upgrade and Select
Component to be Upgraded
component HUA current version
MSP 00-46-01-21-a0 R 1.5.0
MP 1-65-0-2a-a6 R.1.0.4
Wifi Term 33-41-1-e7-42 R 2.0.0
Select the device to be upgraded
...\
USB/
ware les on the USB drive
select device
COMPONENT
selection
select le
FILE
selection
Side B
Remove the USB drive from the computer once the download is nished.
Step 4 Troubleshooting
Follow the screens below to nish upgrading the device. Note that the system
will restart after upgrading the MSP, not after upgrading the Wireless Terminal.
...\
USB/
MSP_AR_R020100
select file
Start the Upgrade
...\
USB/
MSP_AR_R020100
select file
If the problem persists after following these steps, call the Hayward Technical
Service Department at (908)-355-7995 for assistance.
No Conguration: If the Wireless Terminal displays the “Searching for OmniLogic” screen shown below, then the OmniLogic system is not discovering the
Wireless Terminal. To troubleshoot this issue, follow the steps below.
1. Verify that the OmniLogic and the Wireless Terminal are using the same
version rmware. If not, upgrade both to the latest versions available at
FILE
selection
Select the rmware le that
you downloaded from the web
FILE
selection
Press the check mark
www.hayward.com/rmware.
2. Verify that the OmniLogic is connected to your home network and that it
can be controlled by web or mobile application. Refer to the OmniLogic
manual for information on how to troubleshoot your home network connection.
component firmware file
MSP MSP_AR_R020100
ready to upgrade
0%
UPGRADE
Press the check mark to
begin the upgrade
firmware
success ready to restart
component firmware file
MSP MSP_AR_R020100
100%
UPGRADE
firmware
Press the check mark to
nish the upgrade once
it reaches 100%
2. Verify that the Wireless Terminal is connected to your home network.
Refer to page 3 in your HLWIRELESS manual. You may need to “forget”
the previously congured access point and reconnect to the network.
092677 RevC