Hayward OmniLogic Wireless Terminal Quick Start Manual

®
SYSTEM INFO
SYSTEM INFO
OmniLogic
6 Easy
Wireless Terminal
QUICK START GUIDE
Steps
Charge the
Wireless Terminal
Check latest
MSP Firmware
Version
Upgrade MSP
if Necessary
Connect to
Home Wireless
Network
Check latest Wireless Terminal Firmware Version
Upgrade
Wireless Terminal
if Necessary
Step 1 Step 2 Step 3
Charge the Wireless Terminal Check MSP Firmware Version Check Latest Firmware
v
MSP version is displayed
SPA
º
F
themes
cong wizard
system info
backup cong
restore cong
SYSTEM conguration
msp id:3233
component HUA version
MSP
MP
Relays
VSP
Wired Wall Mo..
display
network
web server
date/time
00-46-01-21-a0
1-65-0-2a-d4
3-10-0-0-1
10-0-0-0-4e
33-41-1-e7-42
1 / 2
R 2.0.1
R 1.0.2 R 1.0.2 R 3.0.4
R.2.0.0
90
The following steps should be performed ONLY with the Wireless Terminal placed in the charging cradle, or after charging for at least 8 hours. If a rm­ware upgrade is needed, it must be completed while in the charging cradle.
NOTE: The Wireless Terminal will take 12 seconds to reboot when placed in the charging cradle if the battery is fully discharged.
71º F
air
Before connecting the Wireless Terminal to the OmniLogic system, verify
that you have the latest OmniLogic MSP rmware version. The rmware
version displayed in “System Info” should be the same as the latest version available for download on the web. Follow the screens above to locate your
MSP rmware version and go to Step 3 to nd the latest rmware version
on the web.
cong
A list of all the latest rmware versions available for download appear. Note the rmware version located in the “Local MSP” box. If the version matches
your current version located in Step 2, then move on to Step 4. If not, then
go to Side B of this sheet to perform a rmware upgrade of your MSP.
To nd the latest available rmware
version, go to www.hayward.com/
rmware and select “OmniLogic”
from the “Select Product” drop­down menu and “HLBASE” from the “Select SKU” drop-down menu.
Select the “Firmware Updates” tab.
Step 4 Step 5 Step 6
With the latest MSP version loaded to your OmniLogic, Touch “OK” at the welcome screen below from your Wireless Terminal to enter the wireless
conguration screen.
NOTE: This following procedure assumes that your OmniLogic system is already connected to your home wireless network.
Go to “Wireless” Menu Connect To Home
Wireless Network
The wireless conguration screen will display all available wi networks. Se­lect the desired network from the list and input your password on the screen as shown below. Press the check mark to save your selection. Your Wireless Terminal is now congured to your home wireless network and will automat-
ically pair with your OmniLogic system.
Now that your Wireless Terminal is connected to the OmniLogic system,
the nal step is to verify that the rmware version of the Wireless Terminal
matches that of the MSP.
To nd the current rmware version of the Wireless Terminal, go to the Om­niLogic and follow the same screens shown in Step 2. Then go to the web-
site (Step 3) and verify that the latest rmware version matches that of your Wireless Terminal (shown as “Wi- Term” in the list below). If they match, congratulations, you are nished conguring your Wireless Terminal to your
OmniLogic. If they do NOT match, follow the steps on Side B of this sheet to
perform a rmware upgrade to your Wireless Terminal. The unit must be in the charging cradle when performing a rmware upgrade.
msp id:3233
component HUA version
MSP
MP
Relays
VSP
Wi-fi Term
00-46-01-21-a0
Welcome to the Hayward Wireless Remote
Press OK to setup your new remote.
configuration
OK
NOTE: The Wireless Terminal will only connect to an OmniLogic that is on the same network.
en
ON
Smith Home Wifi
q
w
a
ABC
.?123
Please enter [yourwifi] network password
Network Connections dynamic
WIRELESS connection
password
def g
xyz
space
hij k l
bc
v
o prst u
mn
1-65-0-2a-d4
3-10-0-0-1
10-0-0-0-4e
33-41-1-e7-42
Check Wireless Terminal
Firmware Version
R 3.0.0
R 1.0.2 R 1.0.2 R 3.0.4
R 3.0.0
MSP rmware version
Wireless Terminal rmware
version
Side A
If a rmware upgrade to your MSP or Wireless Terminal is required...
daylight favorites
alarm lights
º
F
air
71º F
82
SERVICE MODE main screen
daylight
sysinfo
upgrade
cong
Step 1 Step 2 Step 3
WARNING - Inserting and removing the USB thumb drive requires re­moval of the front panel. Verify that all power is removed to the Omni­Logic system before removing the front panel.
From your computer: To begin upgrading your MSP or your Wireless Ter-
minal (they should have same rmware version), navigate to the website as shown in Step 3 on Side A of this sheet. Insert your USB thumb drive (not
Download Latest
Firmware Version
Verify that power is removed to the OmniLogic system and remove the front panel. Insert the USB drive into the side of the MSP.
Replace the front panel and then power on the OmniLogic system. When
the system nishes powering back on, enter Service Mode by following the
screens below.
Insert USB into the MSP and Enter Service Mode
Follow the screens below to begin the upgrade for the device.
included) into the computer. Click on the orange download button located in the box of the component that you are upgrading. Save the rmware le to the USB drive. Download the “Wired Terminal” rmware shown below (Wired and Wireless Terminals use the same rmware).
When Upgrading your MSP (Step 3, Side A), select:
When Upgrading your Wireless Terminal (Step 6, Side A), select:
NOTE: It is best if you download the rmware in Chrome, Firefox or Safari browsers. If you download in Internet Explorer, once your download is com­plete, please remove the “.TXT” extension from the le on the USB drive.
service
mode
shut down
features
simple
o
mode
NOTE: Do not choose Timed Service Mode when upgrading a device. If you DO choose Timed Service Mode, be sure to dedicate enough time so that the upgrade will have time to nish. Upgrading a Wireless Terminal can take a
few minutes.
Press “Upgrade” button in Ser­vice Mode menu
component HUA current version
MSP 00-46-01-21-a0 R 1.5.0
MP 1-65-0-2a-a6 R 1.0.4
Wifi Term 33-41-1-e7-42 R 2.0.0
COMPONENT selection
Press the check mark Press “USB” to view the rm-
select device
Press Upgrade and Select
Component to be Upgraded
component HUA current version
MSP 00-46-01-21-a0 R 1.5.0
MP 1-65-0-2a-a6 R.1.0.4
Wifi Term 33-41-1-e7-42 R 2.0.0
Select the device to be up­graded
...\
USB/
ware les on the USB drive
select device
COMPONENT selection
select le
FILE selection
Side B
Remove the USB drive from the computer once the download is nished.
Step 4 Troubleshooting
Follow the screens below to nish upgrading the device. Note that the system
will restart after upgrading the MSP, not after upgrading the Wireless Terminal.
...\
USB/
MSP_AR_R020100
select file
Start the Upgrade
...\
USB/
MSP_AR_R020100
select file
If the problem persists after following these steps, call the Hayward Technical
Service Department at (908)-355-7995 for assistance.
No Conguration: If the Wireless Terminal displays the “Searching for Omni­Logic” screen shown below, then the OmniLogic system is not discovering the Wireless Terminal. To troubleshoot this issue, follow the steps below.
1. Verify that the OmniLogic and the Wireless Terminal are using the same
version rmware. If not, upgrade both to the latest versions available at
FILE selection
Select the rmware le that
you downloaded from the web
FILE selection
Press the check mark
www.hayward.com/rmware.
2. Verify that the OmniLogic is connected to your home network and that it can be controlled by web or mobile application. Refer to the OmniLogic manual for information on how to troubleshoot your home network con­nection.
component firmware file
MSP MSP_AR_R020100
ready to upgrade
0%
UPGRADE
Press the check mark to
begin the upgrade
firmware
success ready to restart
component firmware file
MSP MSP_AR_R020100
100%
UPGRADE firmware
Press the check mark to nish the upgrade once
it reaches 100%
2. Verify that the Wireless Terminal is connected to your home network.
Refer to page 3 in your HLWIRELESS manual. You may need to “forget” the previously congured access point and reconnect to the network.
092677 RevC
Loading...