ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
TEST IDEAL RANGE ADJUSTMENT REQUIRED
Free Chlorine 1.0 - 3.0 ppm
pH 7.2 - 7.8
WEEKLY
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too high - add muriatic acid
Too low - add soda ash.
SwimPure PlusSwimPure Plus
SwimPure Plus
SwimPure PlusSwimPure Plus
®®
®
®®
Alkalinity 80 - 120 ppm
MONTHLY
Salt 2700 - 3400 ppm Add salt as required to increase.
Stabilizer 60 - 80 ppm Add cyanuric acid to increase.
Calcium 200 - 400 ppm Add calcium to increase.
QUARTERLY
Electrolytic Cell inspect & clean Refer to section in manual.
Refer to www.hayward.com for latest manual
revisions, additional information and helpful service.
Add baking soda to increase.
dd acid as required to decrease.
Drain and add water to decrease.
Operation and Installation
Manual
AQR-SWP
620 Division St.
Elizabeth, NJ 07207
Copyright © 2012 Goldine Controls
092099E RevG
www.hayward.com
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions
should always be followed, including the following:
• READ AND FOLLOW ALL
INSTRUCTIONS
• Use Copper Conductors Only
• Disconnect all AC power during installation.
• Warning - To reduce the risk of injury, do not permit
children to use this product unless they are closely
supervised at all times.
• A green colored terminal marked "Earth Ground" is lo-
cated inside the wiring compartment. To reduce the risk
of electric shock, this terminal must be connected to the
grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to
the circuit conductors supplying the equipment.
• One bonding lug for US models (two for Canadian mod-
els) is provided on the external surface. To reduce the
risk of electric shock, connect the local common bonding
grid in the area of the swimming pool, spa, or hot tub to
these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada.
• All field installed metal components such as rails, ladders,
drains, or other similar hardware within 3 meters of the
pool, spa or hot tub shall be bonded to the equipment
grounding bus with copper conductors not smaller than 8
AWG US / 6 AWG Canada.
• NOTICE TO USERS: This control product is to be used
only in accordance with the directions of this label. It is
an offense under the Pest Control Products Act to use a
control product under unsafe conditions.
LIMITED WARRANTY (effective 03/01/12) Hayward warrants its Pro Logic, OnCommand
and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus
and SwimPure chlorination products to be free of defects in materials and workmanship,
under normal use and service, for a period of three (3) years. Hayward also warrants its Aqua
Trol chlorination products to be free of defects in materials and workmanship, under normal
use and service for a period of one (1) year. These warranties are applicable from the initial
date of purchase on private residential swimming pools in the US and Canada. Installations
of product for use on commercial pools in the US and Canada is covered for a period of one
(1) year for defects in materials and workmanship. Hayward warrants all accessories and
replacement parts for the above-identified pool automation and chlorination products for a
period of one (1) year. Accessories also include remotes, actuators, base stations, temperature
sensors, flow switches and chemistry probes. Each of these warranties is not transferable and
applies only to the original owner.
Hayward shall not be responsible for cartage, removal, repair or installation labor or any
other such costs incurred in obtaining warranty replacements or repair.
Proof of purchase is required for warranty service. If written proof of purchase is not
provided, the manufacturing date code will be the sole determinant of the date of installation of the product. To obtain warranty service or repair, please contact the place of
purchase or the nearest Hayward authorized warranty service center. For more information on authorized service centers please contact the Hayward Technical Service
Support Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the Hayward web
site at www.hayward.com.
WARRANTY EXCLUSIONS:
1. Material supplied or workmanship performed by others in process of installation.
2. Damage resulting from improper installation including installation on pools larger than
the product rating.
3. Problems resulting from failure to install, operate or maintain the product(s) in accordance with the recommendations contained in the owners manual(s).
4. Problems resulting from failure to maintain pool water chemistry in accordance with the
recommendations in the owners manual(s).
5. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs
or alternations, fire, flood, lightning, freezing, external water, degradation of natural
stone used in or immediately adjacent to a pool or spa, war or acts of God.
6. Use of a non-genuine Hayward replacement salt chlorination cell on any Hayward
automation or chlorination product will void the warranty for that product.
The express limited warranty above constitutes the entire warranty of Hayward Pool
Products with respect to its products and is in lieu of all other warranties expressed or
implied, including warranties of merchantability or fitness for a particular purpose. In no
event shall Hayward Pool products be responsible for any consequential, special or
incidental damages of any nature. Some states do not allow a limitation on how long an
implied warranty lasts, or the exclusion of incidental or consequential damages, so the
above limitation may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights, which vary from state to state.
• SAVE THESE INSTRUCTIONS
16
4. "Check Salt" LED illuminated or flashing
Be sure that the correct model Turbo Cell has been selected (page 7).
Check salt level in pool/spa. If salt level is low, add salt according to chart on page 4.
Before adding large quantities of salt, it is advisable to have your salt level professionally checked.
5. "High Salt" LED illuminated
Be sure that the correct model Turbo Cell has been selected (page 7).
Check salt level in pool/spa. If salt level is too high, lower salt level by draining some of
the pool water out of the pool and replace with fresh water. Continue until the salt
concentration is at recommended levels.
6. "Inspect Cell" LED flashing
Be sure that the correct model Turbo Cell has been selected (page 7).
Inspect and clean cell according to directions on page 8. When done, press the "diagnostic" button for 3 seconds to stop the "Inspect Cell" LED flashing.
7. "Inspect Cell" LED illuminated
Be sure that the correct model Turbo Cell has been selected (page 7).
8. Possible causes of little or no free chlorine residual
- SwimPure Plus switch in OFF position.
- Desired Output % adjustment setting is too low.
- Low stabilizer (Cyanuric Acid).
- Filter pump time too short (8 hours for average size pools, more for large pools)
- Salt level too low (below 2400 ppm, Check Salt LED on).
- Salt level too high (High Salt LED on).
- Very warm pools increase chlorine demand--increase Output %, or filter run time.
- Cold water (below 50ºF) causes SwimPure Plus to stop generating (Generating LED
flashing).
- Excessive scaling on cell.
- High level of Nitrogen in pool water.
- "Yellow Out" or similar treatment recently used. Some yellow algae treatments will
use chlorine at a very high rate and deplete the residual free chlorine. Manually shock
the pool if indicated in the directions on the algae treatment. It still may be a matter of
days before the pool returns to "normal" and chlorine tests will show the desired 13ppm free chlorine reading.
Table of Contents
OPERATIONOPERATION
OPERATION
OPERATIONOPERATION
GeneralGeneral
General........................................................................................1
GeneralGeneral
Water ChemistryWater Chemistry
Water Chemistry......................................................................1
Water ChemistryWater Chemistry
ControlsControls
Controls......................................................................................6
ControlsControls
MaintenanceMaintenance
Maintenance...............................................................................8
MaintenanceMaintenance
INSTALLATIONINSTALLATION
INSTALLATION
INSTALLATIONINSTALLATION
MountingMounting
Mounting....................................................................................10
MountingMounting
PlumbingPlumbing
Plumbing......................................................................................11
PlumbingPlumbing
WiringWiring
Wiring..........................................................................................12
WiringWiring
TROUBLESHOOTINGTROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTINGTROUBLESHOOTING
TroubleshootingTroubleshooting
Troubleshooting..........................................................................14
TroubleshootingTroubleshooting
9. "-Pcb-" displayed and all 4 red/yellow LEDs are illuminated.
A possible Printed Circuit Board fault has been detected. Call for
service.
15
WARRANTYWARRANTY
WARRANTY
WARRANTYWARRANTY
WarrantyWarranty
Warranty.....................................................................................16
WarrantyWarranty