![](/html/73/73de/73deef06ffbd95e9a440e86442c2a82e55d977c0eb57d260a5bd146e91aea4b8/bg1.png)
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
hereunder and that HAWS shall not be liable for general, special, or consequential
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipm ent. HAWS liability und er this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods,
or part thereof, which shall appear to the Company upon inspection to be of defective
material or not of first class workmanship, provided that claim is made in writing to Haws
within a reasonable period after receipt of the product. Where claims f or defects are made,
the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS
will not be liable for the cost of repairs, alterations or replacements, or for any expense
connected therewith made by the owner or his agents, except upon written authority from
HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective
materials or poor workmanship, except for replacements, as provided above. Buyer agrees
that Haws has made no other warranties either expressed or implied in addition to those
above stated, except that of title with respect to any of the products or equipment sold
damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. T he units also must be used for the
purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED
OR GIVEN BY HAWS.
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297
08/17 Model 9001EXPC1D1 Page 1 of 7
![](/html/73/73de/73deef06ffbd95e9a440e86442c2a82e55d977c0eb57d260a5bd146e91aea4b8/bg2.png)
Alarm horn and lamp do not
Check incoming circuit for power and power
Check that the direction of water flow
Check that water flow is sufficient.
Check all electrical connections for security,
Faulty flow switch. Replace entire switch
Faulty flasher module in alarm. Replace
Horn sounds but lamp does not
Only replace lamp with Haws P/N
Should replacement lamp also fail to operate,
Remove the guard/globe assembly from the
Check wiring connections.
Disconnect flow switch wires and test for
RECOMMENDED TOOLS: Pipe joint sealant, screwdriver, pipe wrench, 14 AWG wire,
3/4” conduit and basic electricians’ tools for power connection.
LOCATION OF UNIT: The Model 9001EXPC1D1 Alarm may be mounted directly to the
upper stand pipe of a safety shower or wall mounted next to a shower or eyewash. The
alarm should be clearly visible from several directions.
ELECTRICAL SUPPLY: 120 VAC 50/60 HZ, 23 Watts average power consumption.
Suitable for use in Class I, Division 1, Group C, D areas; Temperature rating T4 (135°C).
WARNING: Power shall be supplied by a dedicated circuit through a 10 AMP maximum
breaker or fuse and should not supply any power to any other devices.
WATER SUPPLY: The flow switch requires a minimum of 2.4 GPM to activate. Mount
flow switch in supply line with flow in horizontal direction and switch stem extending
vertically from tee. Mount switch with at least 6” of straight pipe on both sides to minimize
operate.
flash.
from flow switch.
corresponds to the arrow on the flow switch
body.
including those in alarm base.
assembly.
flasher module.
0003225505. (See Sheet 3 of Installation
drawing)
replace flasher module.
light fixture to replace the lamp. Only replace
lamp with Haws P/N 0003225505. (See Sheet
3 of Installation drawing)
08/17 Model 9001EXPC1D1 Page 2 of 7
continuity.
![](/html/73/73de/73deef06ffbd95e9a440e86442c2a82e55d977c0eb57d260a5bd146e91aea4b8/bg3.png)
INSTALLATION PROCEDURE
*WARNING: EXPLOSION HAZARD – SUBSTITUTI ON OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS 1, DIVISION 1.
STEP 1: Choose a location for mounting the flow switch in the water supply line. The inlet
and outlet ports of the flow switch must be a minimum of 6 inches from any tees
or elbows in the water supply line. See attached installation drawing.
STEP 2: Mount the flow switch assembly in the water supply line. The switch body must
be in the vertical position with the water pipe horizontal. The water flow must be
in the direction marked by the arrow on the flow switch body. Use pipe sealing
compound on all water pipe connections.
STEP 3: Choose a location for mounting the alarm assembly. The alarm housing should
be positioned along a vertical axis at least 7 feet above ground for best visibility.
The alarm may be mounted directly to a water pipe using the supplied brackets.
The alarm can also be bolted to a flat surface such as a wall, using flanges with
appropriate fasteners (not supplied).
STEP 4: Using wire nuts, connect the flow switch to the alarm and power. The pink and
orange wires are connected to the second normally closed contact of the flow
switch and may be used for remote alarm activation. The signal from the pink
wire will be supply voltage, to be provided to orange wire by customer, when no
water is flowing and zero voltage when the flow switch and local alarm are
activated. If a remote alarm is not used, the pink and orange wires must be
insulated at their free ends. Power to be routed using rigid conduit and a seal
fitting or Class 1, Division1 rated armored cable and an appropriate gland fitting.
See Electrical Wiring Diagram provided on installation drawing. Follow all
instructions in installation drawing and NEC code when installing unit.
OPERATION AND TEST INSTRUCTIONS
Test weekly. Instruct all employees in the use of emergency showers and eyewashes.
STEP 1: Apply power to the alarm branch circuit. The alarm should remain OFF.
STEP 2: Open the shower or eyewash flow valve. The alarm should sound and the light
should flash shortly after water flows from the system.
STEP 3: Shut off the flow valve. The alarm should turn off.
For more information about Haws products see our website: www.hawsco.com
© 2017 Haws® Corporation – All Rights Reserved
HAWS
®
and other trademarks used in these materials are the exclusive property of Haws Corporation.
08/17 Model 9001EXPC1D1 Page 3 of 7