NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipment. HAWS liability under this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods,
or part thereof, which shall appear to the Company upon inspection to be of defective
material or not of first class workmanship, provided that claim is made in writing to Haws
within a reasonable period after receipt of the product. Where claims for defects are made,
the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS
will not be liable for the cost of repairs, alterations or replacements, or for any expense
connected therewith made by the owner or his agents, except upon written authority from
HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective
materials or poor workmanship, except for replacements, as provided above. Buyer agrees
that Haws has made no other warranties either expressed or implied in addition to those
above stated, except that of title with respect to any of the products or equipment sold
hereunder and that HAWS shall not be liable for general, special, or consequential damages
claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. The units also must be used for the
purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED
OR GIVEN BY HAWS.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT:1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297
Model 8317CTFP (120V) &
8317CTFP.220V
LIMITED WARRANTY
No. 2081781 (17
09/14 Model 8317CTFP (120V) & 8317CTFP.220V Page 1 of 9
LOCATION OF UNIT: The Model 8317CTFP (120V) & 8317CTFP.220V Emergency Shower Eye /
Face Wash should be installed in close proximity to potential accident areas. It should be clearly
identified, free from obstructions and easy to access. Suitable for use in Class 1, Division 2 Group B,C,&
D areas. Temperature rating T6 (85º C).
ELECTRICAL SUPPLY FOR MODEL 8317CTFP: Electrical power required for standa rd heat traced
unit is 120 VAC. Average power consumption at 50º F (10º C) ambient temperature is 125 watts.
Maximum less lighting is 150 watts. Connection at input junction box is 3/4” NPT. DURING
POTENTIALLY FREEZING PERIODS; INSURE THAT UNIT IS CONNECTED TO A CONTINUOUS
POWER SUPPLY.
ELECTRICAL SUPPLY FOR MODEL 8317CTFP.220V: Electrical power required for standard heat
traced unit is 220 VAC. Average power consumption at 50º F (10º C) ambient temperature is 125 watts.
Maximum less lighting is 150 watts. Connection at input junction box is 3/4" NPT. DURING
POTENTIALLY FREEZING PERIODS; INSURE THAT UNIT IS CONNECTED TO A CONTINUOUS
POWER SUPPLY.
WATER SUPPLY: The minimum recommended line is 1-1/4” IPS with 30-90 psi (2-6 ATM ) flowin g
pressure. An inlet filter is recommended where sediment or mineral content is a problem. Inlet
connection is 1-1/4” IPS. WATER SUPPLY MUST BE FREEZE PROTECTED.
MAINTENANCE: In freezing conditions, wipe eye/face wash head and dust cover dry after each use to
prevent unwanted ice buildup. SP158B Freeze Protection Valve is a field serviceable item Refer to
SP158B Manual for more information.
WARNING: Fire and shock hazards: Must use a ground fault electrical protection device (30mA
GFEPD) for Heat Trace. Electrical fault currents may be insufficient to trip a conventional circuit
breaker.
INSTALLATION PROCEDURE
Refer to Installation Drawings for clarification. Use pipe joint sealant on all connections.
STEP 1: Prepare the emergency shower foundation locating three 3/8” anchors (not supplied), for
shower floor flange. Note flange hole positions so shower head eye/face wash and su pply inlet
will be in proper direction. Raise shower into position and shim under floor flange if required to
STEP 2: Connect water supply as follows: This model is designed for either a top water supply or a
maintain upright vertical.
bottom water supply. This model is shipped with a complete 1-1/4” IPS union connected at
the top supply inlet. At the bottom supply inlet there is only half of a 1-1/4” IPS union. The
other half of the union is connected to a freeze protection bleed valve located inside the
shipping carton. Remove outer half of the 1-1/4” union from the top water inlet. Assemble the
half union onto 1-1/4” IPS male thread of either the top or bottom water supply.
Complete supply connection at the desired 1-1/4” union. Attach the other half union with the
freeze valve attached to the other unused union and complete the connection. Refer to
SP158B Freeze Protection Valve installation instructions on Sheets 2 and 3 of installation
drawing.
Turn on water supply and check for leaks, then operation of eye/face wash and
shower together. If flow of either is inadequate check troubleshooting chart. Heat
trace (supplied), insulate and weather seal inlet union and above ground supply (by
others). If flow switch is used, heat-trace and insulate 6” above flow switch tee.
09/14 Model 8317CTFP (120V) & 8317CTFP.220V Page 2 of 9
Page 3
INSTALLATION PROCEDURE...
STEP 3: Connect electrical power supply conduit to input junction box using suitable conduit
fitting into 3/4” NPT inlet. Install optional area light and indicator light, if desired. For
MODEL 8317CTFP (120V): connect 120 volt AC line to 16 gauge shower wires as
follows: Black = 120 VAC, White = Neutral, Green = Ground.
For MODEL 8317CTFP.220V:
Connect 220 volt AC line to 16 gauge shower wires as follows: Black = 220 VAC,
Red = 2
Electrical Schematic Drawing, Sheet 4 of Installation Drawing).
nd
Hot, Green = Ground. Turn on power supply to complete installation. (See
OPERATING INSTRUCTIONS
Power to the 8317CTFP (120V) & 8317CTFP.220V may be left on year round. The nonadjustable thermostat will shut off heat cable when air temperature rises to 55
Heat cycle will repeat when air temperature drops to between 45º -55º F (7º - 13ºC).
C).
Periodic check of water temperature from shower or eye/face wash will confirm normal
operating temperatures between 45
º- 95ºF (7º-35ºC).
This unit is heated by low power heat trace cable suitable for freeze protection but not suitable
for providing a warm shower from a cold water supply. Moments after activating shower, water
temperature will drop to supply temperature.
º - 65º F (12º - 18º
ANSI recommends a comfortable shower temperature range of 60
ºF (15ºC) to 100ºF (38ºC). For
the protection of the user, we strongly recommend that some system be installed to provide
tempered (warm) water to this shower and eye/face wash. Heat trace cable used on this
shower heats slowly and may take 90 minutes to complete a full heat cycle.
No drain connection at bleed valve(s) is normally required. Valve(s) will remain closed unless
power outage, high ambient temperature (with optional scald protection valve, only) or
malfunction occurs (see Troubleshooting).
NOTE: IF GROUND WATER IS BELOW 38ºF (3.3ºC) SIMPLY TESTING SHOWER MIGHT
CAUSE BLEED VALVE TO OPEN. ONCE OPENED, COLD GROUND WATER WILL KEEP
BLEED VALVE OPEN. SEE TROUBLESHOOTING GUIDE FOR PROCEDURE TO CLOSE
BLEED VALVE ONCE OPENED.
Periodic tests for proper function of shower and eye/face wash should be performed and
recorded on inspection tags attached to unit or in separate maintenance logbook (preferred).
IMPORTANT SAFETY NOTICE
THE NATIONAL ELECTRICAL CODE REQUIRES GROUND-FAULT EQUIPMENT
PROTECTION ON EACH HEATING CABLE BRANCH CIRCUIT. TO REDUCE THE RISK OF
FIRE CAUSED BY DAMAGE OR IMPROPER INSTALLATION, CIRCUIT BREAKERS SUCH
AS SQUARE D QO-EPD AND QOB-EPD OR EQUIVALENT, WITH A 30mA TRIP LEVEL,
SHOULD BE USED. PLEASE SUBSTITUTE THESE BREAKERS WHEREVER REFERENCE
IS MADE TO CONVENTIONAL BREAKERS IN THIS DOCUMENT. ALTERNATIVE DESIGNS
PROVIDING COMPARABLE LEVELS OF GROUND-FAULT PROTECTION MAY ALSO BE
ACCEPTABLE.
09/14 Model 8317CTFP (120V) & 8317CTFP.220V Page 3 of 9
Page 4
TROUBLESHOOTING
PROBLEM
1. Continuous flow from freeze bleed valve. 1. If bleed water temperature is above 45ºF (7ºC),
2. Continuous flow from scald bleed valve.
(Optional valve).
3. Shower and eye/face wash water
temperature below 40ºF or above 100ºF.
4. Insufficient flow at shower and eye/face
wash.
5. Insufficient flow at eye/face wash only.
6. Insufficient water flow at the showerhead,
however, eye/face wash is sufficient.
7. Shower and eye/face wash valve stem leak.7. Remove shower arm or eye/face wash push flag.
8. Shower and eye/face wash valve leaks.
(Does not shut off completely).
REPAIR CHECKLIST
service bleed valve. For specific instruction regarding
removal, maintenance and re-installment of this
model, contact Haws Technical Support at 1-800640-5612. If below 45ºF (7ºC), verify electric power
to unit, then check thermostat. See item 3 below.
Once opened, cold supply water, (45ºF (7ºC), will
keep freeze bleed valve open. To shut bleed valve, it
must be warmed above 45ºF (7ºC).
2. If bleed water temperature is below 90ºF (32ºC),
service bleed valve. For specific instruction regarding
removal, maintenance and re-installment of this
model, contact Haws Technical Support at 1-800640-5612. Above 100ºF (38ºC) may be due to direct
sunlight or excess ambient temperature.
3. Shut off electric power. All electric connections are
made inside external junction box. Thermostat is
mounted in top port of junction box. Disconnect
thermostat leads from terminal block and wire nut in
junction box. Check thermostat continuity: open
circuit above 65ºF (18ºC), closed below 45ºF (7ºC).
Thermostat is not adjustable and should be replaced
if either of the continuity checks are incorrect. If unit
is subject to freezing temperatures, temporarily
disconnect thermostat and reconnect wiring to
bypass thermostat and protect shower from freezing
until replacement thermostat can be installed. Selfregulating heat trace cable will not overheat shower
until air temperature rises above 85ºF (30ºC).
4. Verify minimum 30 PSI (2 ATM), 28 gallon (106 liters
per minute) available supply. Check for blockage in
lines.
5. Probable clogging of flow control due to inadequate
line flushing. Turn water supply off. Unscrew
eye/face wash heads and adapter to gain access
and clean flow control.
6. Probable clogging of flow control inside showerhead.
Unscrew showerhead off of elbow and clean rubber
flow control.
Peel black trim strip from shower and separate
housing halves. Peel back or remove insulation to
gain access to valve. Remove “U” bracket from valve
stem and tighten valve stem hex packing nut to stop
leak. Reassemble bracket, insulation, shower
housing and valve arm.
8. Disconnect power to unit. Disassemble as in item 6.
Check valve arm stop tang for damage. Repair or
replace valve assembly. Heat cable is looped around
valve and should be pulled away from valve. Remove
valve. Reverse above steps to reassemble.
and other trademarks used in these materials are the exclusive property of Haws Corporation.
09/14 Model 8317CTFP (120V) & 8317CTFP.220V Page 4 of 9
Page 5
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEM ENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
SP155 THERMOSTAT
SHOWER VALVE ASSEMBLY
SP178
SHOWER/EYEWASH
SIGN
SP829
1-1/4" UNION
SHOWER HEAD
DRENCH HOSE VALVE
ASSEMBLY
www.hawsco.com
SP200
PULL ROD
www.hawsco.com
EYEWASH VALVE
ASSEMBLY
SP170 TEST TAG
DRENCH HOSE
SP158B FREEZE
PROTECTION VALVE
(SEE PAGES 7 & 8
FOR ADDITIONAL
COMPONENTS)
BYECN NO.
REVISED PER
ECN:
RTM
4921
DATE
03/29/05
FV
DRAWN
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
C
2014
Haws Corporation - All Rights Reserved
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
APPROVED
DATE
10/21/14
FV
CHKD
MODEL(S)
1/18
SCALE:
8317CTFP(120V) / 8317CTFP.220V
DRAWING TYPE:SIZE: A
PARTS BREAKDOWN
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (755) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
PAGE
PART NUMBER
0002081781
DRAWING NO.
15200A00 17
SHEETOF
11
5 of 9
REV
Page 6
C
Haws Corporation - All Rights Reserved.
2014
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
NOTES:
1. DIMENSIONS MAY VARY BY ± 1/2 INCH [13mm].
2. TO COMPLY WITH AN S I Z 358. 1- 2009 FOR EMERGEN CY EYEWASH OR EYE/FACE WASH A ND SHOWER EQUIPMENT:
- UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTABLE PLUMBING PRACTICES.
- EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED WITH NOZZLES NOT LESS THEN 83.8 CM (33 IN.) AND NO GREATER THAN
114.3 CM (45 IN.) FROM SURFACE ON WHICH USER STANDS AND 15.3 CM (6 IN.) MINIMUM FROM WALL OR NEAREST OBSTRUCTION.
- SHOWER SHALL BE POSITIONED SO THAT SHOWER HEAD IS NOT LESS THAN 208.3 CM (82 IN.) NOR MORE THAN 243.8 CM (96 IN.)
FROM SURFACE ON WHICH USER STANDS.
- SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 50.8 CM (20 IN.) AT 152.4 CM (60 IN.) ABOVE SURFACE ON WHICH
USER STANDS, AND CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 40.6 CM (16 IN.) FROM ANY OBSTRUCTION.
3. DO NOT USE REGULAR PIPE SEALANT. IF NECESSARY USE DOW CORNING 832 SEALANT PLACING 5 SMALL
BEADS ON THE MALE THREADS, JUST ABOVE THE FIRST THREAD.
(NOTES CONTINUED ON SHE E T 2 O F 4. )
2426mm
95-1/2"
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
152mm
6"
DRENCH HOSE
DRENCH HOSE ACTIVATION
VALVE ASSEMBLY
3
3/4" NPT JUNCTION BOX
FLOOR LINE
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
2299mm
90-1/2"
2172mm
85-1/2"
67-1/4"
1708mm
41-3/4"
1060mm
178mm
7"
APPROVED:
DRAWN:
RTM
FV
REVISE D PER
ECN:
DATE:
03/29/05
4921
DATE:
10/21/14
CHK'D.:
BY:ECN NO.
FV
SCALE:
MODEL(S)
355mm
14"
ABS JACKET
REMOVABLE
MOUNTING LOCATION
AREA LIGHT
FOR OPTIONAL
POWER CON NE C TIO N
927mm
36-1/2"
1098mm
43 1/4"
1/20
8317CTFP(120V)/ 8317CTF P.2 20V
DRAWING TYPE:SIZE: A
INSTALLATION
0002081781.D
PART NUMBER
DRAWING NO.
SHEETOF
15201A00 17
14
REV
MOUNTING LOCATION
FOR OPTIONAL
INDICATOR LIGHT
6-3/4"
INSTALLATION INSTRUCTIONS.)
SP158B FREEZE PROTECTION VALVE
(SEE NOTES ON SHEETS 2 & 3 FOR
(775) 359-4712 FAX (755) 359- 7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.H A WSCO.CO M
SPARKS, NEVADA 89431
1455 KLEPPE LANE
171mm
NOTE: PULL ROD AND HA NDLE NOT
MUST BE IN UP POSITION WHEN FULLY
CLOSED AND PULL ROD INSERTED IN
HOLE SHOWN.
ASSEMBLED. ORIENTATION OF HANDLE
TRACED AND INSULATED
SUPPLY MUST BE HEAT
Ø9"
Ø203mm
Ø8"
B.C.
30°
3X
Ø10mm
Ø3/8"
Ø229mm
20-1/2"
521mm
TO A BOTTOM SUPPLY UNIT.
MANUAL (PAGE 2) TO CONVERT
OF THE INSTALLATION PROCEDURE
TOP SUPPLY SHOWN. SEE STEP 2
IN THE OPERATION & MAINTENANCE
1-1/4" IPS SUPPLY UNION (INLET)
IMPORTANT
PAGE
6 of 9
6 3/4"
171mm
Page 7
C
Haws Corpor at ion - All Rights Reserved.
2014
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
MAKE SPECIFICATIONS AND MEASURE M ENTS SUBJECT TO CHANGE WITHOUT NOTICE.
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IM PROVEMENTS