Haws 8309 User Manual

Page 1
)
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
E-mail: haws@hawsco.com website: www.hawsco.com
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale.
Model 8300-8309/8300CRP-8309CRP
Shower & Eye/Face Wash
LIMITED WARRANTY
The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.
No. 2080162(21
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297
04/14 Model 8300-8309/8300CRP-8309CRP Page 1 of 5
Page 2
LOCATION OF UNIT: The Model 8300/8300CRP/8309/8309CRP Emergency Shower should be installed in close proximity to potential accident areas. It should be clearly identified, free from obstructions and easy to access.
SUPPLY LINE: The minimum recommended line size is 1-1/4” IPS with 30-90 psi (2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.
PLUMBING CONNECTIONS: Inlet supply is female 1-1/4” IPS. Waste outlet is female 1-1/4” IPS.
INSTALLATION PROCEDURE
Refer to Installation Drawing for clarification. Check parts list to insure all required parts are included. Use pipe joint sealant PST #565 (Loctite) on all connections.
STEP 1: Prepare the emergency shower foundation by using the floor flange
assembly as a template. Locate the three holes for the 3/8-16 UNC x 6” anchor bolts (not supplied). They should extend 1” above the floor level.
STEP 2: Once the concrete foundation is ready (dry), assemble the floor flange
assembly to the anchor bolts; then securely fasten with 3/8-16 UNC Hex nuts and 3/8” washers (not supplied). Seal and tighten floor flange and tee (1-1/4”) making certain the waste tee is facing the proper location and the foot control holes are facing side to side.
STEP 3: Assemble nipple (1-1/4” x 21-1/2”) to the floor flange assembly and tighten
with a pipe wrench.
STEP 4: Assemble the eyewash loop assembly to the 21-1/2” nipple from Step
three. Connect the pipe wrench to the galvanized nipple between the two tees to avoid damage.
STEP 5: Assemble in the following order: Attach nipple (1-1/4” x 24”) onto the loop assembly.
Attach nipple (1-1/4” x 24”) onto the tee (1-1/4”). Attach tee (1-1/4” x 1-1/4” x 1”) onto nipple. Attach nipple (1x 9”) valve assembly onto tee (1-1/4” x 1-1/4” x 1”). Assemble the street elbow (1”) onto nipple (1” x 12-1/2”). Attach nipple onto valve.
STEP 6: Assemble showerhead onto street elbow (1”). STEP 7: Assemble the sign onto the unit. Use the strap, screws, washers and nuts
provided to mount the sign onto the upright. The sign should be positioned for maximum visibility.
STEP 8: Insert the plug into the optional supply line tee that is not used. Before
connecting the supply water line to the emergency shower, FLUSH THE
LINE THOROUGHLY.
04/14 Model 8300-8309/8300CRP-8309CRP Page 2 of 5
Page 3
TROUBLESHOOTING
PROBLEM
1. No flow. 1. Check the main shut-off valve.
2. Water leak between joints or fittings. 2. Tighten loose connections. If leak
REPAIR CHECKLIST
persists, the application of hot water will sometimes reseat improperly applied joint compound. After 30 minutes wait and retest. A persistent leak will necessitate reassembly and additional sealant.
3. Insufficient water flow, shower and eyewash.
3. Verify minimum 30 psi (2 ATM) flowing supply line pressure.
4. Water does not drain properly. 4. Check your drain system for debris. Check the main waste line of your building to see if it does handle the capacity required for the entire drainage system.
5. Insufficient water flow on eyewash,
however, shower is sufficient.
5.a. Verify minimum 30 psi (2 ATM) flowing supply line pressure.
b. Probable clogging of flow control due
to inadequate line flushing. Unscrew eye/face wash head and remove the four screws to disassemble head. Clean flow control and reassemble head. See SP65 Installation Drawing for details.
c. Remove cap located on L – Strainer
using a 3/8” allen wrench to access and clean filter screen.
6. Eyewash or face wash streams do not meet at desired eye level or are not balanced.
7. Insufficient water flow at the showerhead, however, eyewash is sufficient.
6. Possible blocked flow control see above solution. (Possible non-leveled eyewash assembly.)
7.a. Probable clogging of flow control inside shower head. Unscrew shower head off of elbow and clean rubber flow control.
© 2014 Haws® Corporation – All Rights Reserved HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.
04/14 Model 8300-8309/8300CRP-8309CRP Page 3 of 5
Page 4
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREM ENTS SUBJECT TO CHA NGE WITHO UT NOTICE.
2
1
OPTIONAL
3
ITEM DESCRIPTION
1 SHOWER HEAD 2 VALVE ASSEMBLY 3 SHOWER SIGN
FOOT TREADLE (NOT SHOWN)
4
PULL ROD
5 6
EYE/FACE WASH ASSY
7
SS BOWL
8
VALVE ASSEMBLY
9
STRIPE TA PE
10
TEST TAG
11
L-STRAINER
--
STR. REPAIR KIT
--
EYEWASH ASSEMBLY
PART NO.
SP829 SP260 SP178 SP220 SP200 SP65
SP90 SP225 SP185 SP170 SP509
VRKEWSTR
SP62FC
5
9
6
7
11
8
SP65 EYE/FACE WASH ASSEMBLY
10
BYECN NO.
REVISED PER
ECN:
4910
DATE
DRAWN
CLF
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
C
2014
Haws Corporation - All Rights Reserved
HAWS and other trademarks use d in these materials are the exc l usive property of Haws Corporation.
R
APPROVED
03/10/93
DATE
HM
CHKD
MODEL(S)
SCALE:
1:1
8300-8309/8300CRP-8309CRP
DRAWING TYPE: SIZE: A
PARTS BREAKDOWN
1455 KLEPPE LANE
SPARKS, NEVAD A 8943 1
(775) 359-4712 F AX (755) 359-7424
E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM
PAGE
PART NUMBER
0002080162
DRAWING NO.
11488C00 21
SHEET OF
11
4 of 5
REV
Page 5
C
Haws Corporation - All Rights Reserved.
2014
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
NOTES:
1. DIMENSIONS MAY VARY BY ± 1/2 INCH [13mm].
2. TO COMPLY WITH ANSI Z358.1-2009 FOR EMERGENCY EYEWASH OR EYE/FACE WASH AND SHOWER EQUIPMENT:
- UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTABLE PLUMBING PRACTICES.
- EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED WITH NOZZLES NOT LESS THEN 83.8 CM (33 IN.) AND NO GREATER THAN
114.3 CM (45 IN.) FROM SURFACE ON WHICH USER STANDS AND 15.3 CM (6 IN.) MINIMUM FROM WALL OR NEAREST OBSTRUCTION.
- SHOWER SHALL BE POSITIONED SO THAT SHOWER HEAD IS NOT LESS THAN 208.3 CM (82 IN.) NOR MORE THAN 243.8 CM (96 IN.)
FROM SURFACE ON WHICH USER STANDS.
- SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 50.8 CM (20 IN.) AT 152.4 CM (60 IN.) ABOVE SURFACE ON WHICH
USER STANDS, AND CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 40.6 CM (16 IN.) FROM ANY OBSTRUCTION.
3. DO NOT USE REGULAR PIPE SEALANT. IF NECESSARY USE DOW CORNING 832 SEALANT PLACING 5 SMALL
BEADS ON THE MALE THREADS, JUST ABOVE THE FIRST THREAD.
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
1661mm
65
8
"
3
SP829
3
FLOOR LINE
2096mm
82
2
"
1
L-STRAINER
280mm
11"
635mm
25"
1056mm
41
2
"
1
238mm
9
3
8
"
APPROVED:
DRAWN:
SLS
REVI SED PER
ECN:
DATE:
04/25/08
4910
DATE:
BY:ECN NO.
CHK'D.:
HM
SCALE:
MODEL(S)
1:1
8300-8309/8300CRP/8309CRP
DRAWING TYPE: SIZE: A
INSTALLATION
0002080162.D
PART NUMBER
DRAWING NO.
SHEET OF
09459A00 21
11
REV
167mm
6
2
1
"
1-1/4"
IPS
WASTE
1567mm
61
4
"
3
(699mm)
(27
2
1
")
IPS
1-1/4"
SUPPLY
2266mm
89
1
4
"
30°
SCALE 10 :1
TOP VIEW
(775) 359-4712 FAX (755) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
SPARKS, NEVADA 89431
1455 KLEPPE LANE
203mm
ø
B.C.
8"
9.5mm
3X ø
ø
229mm
9"
3/8"
PAGE
5 of 5