Haws 7501BLH, 7501BL240H Installation, Operation & Maintenance Instructions Manual

Page 1
No. 0510000809(1)

Model 7501BLH/7501BL240H

INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS

LIMITED WARRANTY

or part thereof, which shall appear to the Company upon inspection to be of defective
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
Hazardous Location Heated Blanket for 7501 Portable Eyewash
HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods,
material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
.
FOR CUSTOMER SERVICE: 1-888-640-4297
03/18 Model 7501BLH/7501BL240H Page 1 of 6
Page 2
CAUTION: A GROUND FAULT DEVICE MUST BE USED WITH THIS HEATING DEV ICE. ATTENTION: CE PRODUIT DOIT ÊTRE UTILISÉ AVEC UNE PROTECTION DE MISE À LA
TERRE. THIS HEATING BLANKET IS ONLY FOR USE WITH HAWS MO DEL 7501 PORTABLE
EYEWASH.
RECOMMENDED TOOLS: Assorted tools as needed for installing power cord. LOCATION OF UNIT: The Model 7501BLH/7501BL240H heated blanket should be installed
over a 7501 tank in close proximity to potential accident areas. It should be clearly identified, free from obstruction, and easily accessible. This assembly should be wall mounted in accordance with the 7501 installation instructions. NOTE: Portable eyew ash unit Models
7501BLH/7501BL240H shall not be exposed to ambient temperatures exceeding 38C (100F). Models 7501BLH/7501BL240H are suitable for use in Class 1, Division 2 Group B, C,
& D, temperature rating T6 (85°C) and Class 2, Division 2 Group F, G, NEMA/TYPE 4 areas. ELECTRICAL SUPPLY FOR MODEL 7501BLH: 120VAC, 60 Hz, 1.38A. No power cord is
supplied. The junction box is undrilled; the user must drill an appropriate hole for a suitable hazardous-rated electrical fitting. The Model 7501BLH must use a ground fault protection device (30mA GFCI) for Heat Trace. Electrical fault currents may be insufficient to tri p a conventional circuit breaker. Units are suitable for installation and use in Class 1, Division 2, Group B, C, D, T6, Class 2, Division 2, Group F, G, NEMA/TYPE 4 areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE AND/OR FEDERAL CODES USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I, II, DIVISION 2 – NO RIGID CONNECTION PERMITTED. DURING POTENTIAL FREEZING PERIODS INSURE THAT
UNIT IS CONNECTED TO A CONTINUOUS POWER SUPPL Y. ELECTRICAL SUPPLY FOR MODEL 7501BL240H: 240VAC, 50/60 Hz, 0.64A. No power
cord is supplied. The junction box is undrilled; the user must drill an appropriate hole for a suitable hazardous-rated electrical fitting. The Model 7501BL240H must use a ground fault protection device (30mA GFCI) for Heat Trace. Electrical fault currents may be insufficient to trip a conventional circuit breaker. Units are suitable for installation and use in Class 1, Division 2, Group B, C, D, T6, Class 2, Division 2, Group F, G, NEMA/TYPE 4 areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE AND/OR FEDERAL CODES USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I, II, DIVISION 2 – NO RIGID CONNECTION PERMITTED. DURING POTENTIAL FREEZING PERIODS INSURE THAT
UNIT IS CONNECTED TO A CONTINUOUS POWER SUPPL Y. AMBIENT TEMPERATURE RATING:
-30°F (-35°C) TO 100°F (38°C)
03/18 Model 7501BLH/7501BL240H Page 2 of 6
Page 3
INSTALLATION PROCEDURE
NOTE: Instructions apply to all models unless otherwise specified. STEP 1: Unpack the blanket. Lay flat with inner surface (silver) up.
STEP 2: Install the power cord in the junction box using a suitable hazardous-rated electrical
fitting and flexible conduit or cable rated for Class I, II, Division 2. RIGID CONNECTIONS ARE NOT PERMITTED. The junction box is undrilled; the user must drill the appropriate size hole for the electrical fitting used. Wire the power cord to terminal block referencing the supplied electrical drawing. The cord and fittings selected must have the appropriate hazardous rating required for the installation location. The Model 7501BL240H/7501BL240H must use a ground fault protection device (30mA GFCI) for Heat Trace.
NOTICE: MODEL 7501BLH/ 7501BL240H REQUIRES MINIMUM NEMA/TYPE 4 COMPLIANT EQUIPMENT. ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC/ CEC CODE USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I, II, DIVISION 2 – NO RIGID CONNECTION PERMITTED. THE CORD AND FITTINGS SELECTED MUST HAVE THE APPROPRIATE HAZARDOUS LOCATION RATING REQUI RED FOR THE INSTALLATION LOCATION.
STEP 3: Set 7501 tank bottom down on the blanket in the orientation shown.
03/18 Model 7501BLH/7501BL240H Page 3 of 6
Page 4
STEP 4: Wrap the blanket up and over the 7501 tank and attach bottom Velcro closures.
STEP 5: Fold side flaps to over sides of tank using the Velcro to attach the edges together.
STEP 6: Pull open/down eyewash flap and yellow eyewash arm. Attach webbing loop around
eyewash arm below eyewash heads.
STEP 7: Mount assembled eyewash and blanket in accordance with 7501TH/7501T240H
installation instructions.
IMPORTANT SAFETY NOTICE
THE NATIONAL ELECTRICAL CODE REQUIRES GROUND-FAULT EQUIPMENT PROTECTION ON EACH HEATING CABLE BRANCH CIRCUIT. TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER INSTALLATION, CIRCUIT BREAKERS SUCH AS SQU ARE D QO-EPD AND QOB-EPD OR EQUIVALENT, WITH A 30mA TRIP LEVEL, SHOULD BE USED. PLEASE SUBSTITUTE THESE BREAKERS WHEREVER REFERENCE IS MADE TO CONVENTIONAL BREAKERS IN THIS DOCUMENT. ALTER NATIVE DES IGNS PROVIDING COMPARABLE LEVELS OF GROUND-FAULT PROTECTION MAY ALSO BE ACCEPTABLE.
03/18 Model 7501BLH/7501BL240H Page 4 of 6
Page 5
TROUBLESHOOTING

PROBLEM

REPAIR CHECKLIST

breaker.
on junction box.
sunlight or excess ambient temperature.
thermostat can be installed.

OPERATING INSTRUCTIONS

The 7501BLH/7501BL240H can be connected to power year-round. The non-adjustable thermostat will shut off heat cable when air temperature rises to 82°-72°F (28°-22°C). Heat cycle will repeat when air temperature drops to between 62°-72°F (16°-22°C). Periodic check of water temperature of eyewash will confirm normal operating temperatures between 62°-95°F (16°-35°C).
Heat trace cable used on this blanket heats slowly and may take several hours to warm cold water into ANSI recommend temperature range of 60°F (15°C) to 100°F ( 38°C).
1. Heat trace does not turn on. 1. a. No power to unit. Check GFCI and circuit
b. If ambient temperature is high and
doesn’t allow the blanket temperature to drop below 67°F (19°C) the heater may not switch on. Heater settings are: Non­adjustable thermostat preset to switch on at 67°± 5°F (17°± 3°C) and switch off 77°± 5°F (25°± 3°C). Test the thermostat and heater function by applying ice thermostat for approximately 3-5 minutes. The heat trace cable should become warm to the touch when operating properly. Thermostat is located
2. Eyewash water is above 100°F (38°C).
b. Shut off electric power. All electric
For more information on Haws products, see our website: www.hawsco.com
© 2018 Haws HAWS
03/18 Model 7501BLH/7501BL240H Page 5 of 6
®
®
Corporation – All Rights Reserved
and other trademarks used in these materials are the exclusive property of Haws Corporation.
1. a. Ambient air temperature is above 100°F (38°C). Relocate eyewash out of direct
connections are made inside the junction box. Thermostat is mounted on the side of junction box. Disconnect thermostat leads from terminal block and wire nut in junction box. Check thermostat continuity: open circuit above 82°F (28°C), closed below 62°F (16°C). Thermostat is not adjustable and should be replaced if either of the continuity checks are incorrect. If unit is subject to freezing temperatures, temporarily disconnect thermostat and reconnect wiring to bypass thermostat and protect eye wash from freezing until replacement
Page 6
THIS DOCUMENT IS TRUE AND CORRECT AT TIM E OF PUB L ICATION. CONTINUED PRODUCT IMPROV E ME NTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
GROUND
POWER IN
6 of 6
PAGE
TERMINAL
BLOCK
GREEN BLACK WHITE (120V) / RED (240V)
120 VAC MODEL 7501BLH 240 VAC MODEL 7501BL240H
THERMOSTAT
MODEL 7501BLH / 7501BL240H
ELECTRICAL DETAIL
FOR MODELS 7501BLH & 7501BL240H:
1. ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE (30mA GFCI) FOR HEAT TRACE. ELECTRICAL CURRENTS MAY BE INSUFFICIENT TO TRIP A CONVENTIONAL CIRCUIT BREAKER. ALL INSTALLATIONS MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE, AND/OR FEDERAL CODES.
2. ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC/CEC CODE USING FLEXIBLE CONDUIT OR CABLE RATED FOR NEMA/TYPE 4 – NO RIGID CONNECTION PERMITTED. MODEL 7501BLH/ 7501BL240H REQUIRES MINIMUM NEMA/TYPE 4 COMPLIANT EQUIPMENT. THE CORD AND FITTINGS SELECTED MUST HAVE THE APPROPRIATE HAZARDOUS LOCATION RATING REQUIRED FOR THE INSTALLATION LOCATION.
C
2018
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
R
5235
DRAWN:
CC
APPROVED:
MJ
REVISED PER
ECN:
5235
DATE: 12/28/17
DATE:
BY:ECN NO. CHK'D.:
05/29/18
MODEL(S)
CC MJ
SCALE:
SHIELD
HEAT TRACE CABLE
1:1
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM
7501BLH / 7501BL240H
ELECTRICAL SCHEMATIC