Haws 7501BLH, 7501BL240H Installation, Operation & Maintenance Instructions Manual

No. 0510000809(1)

Model 7501BLH/7501BL240H

INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS

LIMITED WARRANTY

or part thereof, which shall appear to the Company upon inspection to be of defective
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
Hazardous Location Heated Blanket for 7501 Portable Eyewash
HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods,
material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR
MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
.
FOR CUSTOMER SERVICE: 1-888-640-4297
03/18 Model 7501BLH/7501BL240H Page 1 of 6
CAUTION: A GROUND FAULT DEVICE MUST BE USED WITH THIS HEATING DEV ICE. ATTENTION: CE PRODUIT DOIT ÊTRE UTILISÉ AVEC UNE PROTECTION DE MISE À LA
TERRE. THIS HEATING BLANKET IS ONLY FOR USE WITH HAWS MO DEL 7501 PORTABLE
EYEWASH.
RECOMMENDED TOOLS: Assorted tools as needed for installing power cord. LOCATION OF UNIT: The Model 7501BLH/7501BL240H heated blanket should be installed
over a 7501 tank in close proximity to potential accident areas. It should be clearly identified, free from obstruction, and easily accessible. This assembly should be wall mounted in accordance with the 7501 installation instructions. NOTE: Portable eyew ash unit Models
7501BLH/7501BL240H shall not be exposed to ambient temperatures exceeding 38C (100F). Models 7501BLH/7501BL240H are suitable for use in Class 1, Division 2 Group B, C,
& D, temperature rating T6 (85°C) and Class 2, Division 2 Group F, G, NEMA/TYPE 4 areas. ELECTRICAL SUPPLY FOR MODEL 7501BLH: 120VAC, 60 Hz, 1.38A. No power cord is
supplied. The junction box is undrilled; the user must drill an appropriate hole for a suitable hazardous-rated electrical fitting. The Model 7501BLH must use a ground fault protection device (30mA GFCI) for Heat Trace. Electrical fault currents may be insufficient to tri p a conventional circuit breaker. Units are suitable for installation and use in Class 1, Division 2, Group B, C, D, T6, Class 2, Division 2, Group F, G, NEMA/TYPE 4 areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE AND/OR FEDERAL CODES USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I, II, DIVISION 2 – NO RIGID CONNECTION PERMITTED. DURING POTENTIAL FREEZING PERIODS INSURE THAT
UNIT IS CONNECTED TO A CONTINUOUS POWER SUPPL Y. ELECTRICAL SUPPLY FOR MODEL 7501BL240H: 240VAC, 50/60 Hz, 0.64A. No power
cord is supplied. The junction box is undrilled; the user must drill an appropriate hole for a suitable hazardous-rated electrical fitting. The Model 7501BL240H must use a ground fault protection device (30mA GFCI) for Heat Trace. Electrical fault currents may be insufficient to trip a conventional circuit breaker. Units are suitable for installation and use in Class 1, Division 2, Group B, C, D, T6, Class 2, Division 2, Group F, G, NEMA/TYPE 4 areas and MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE AND/OR FEDERAL CODES USING FLEXIBLE CONDUIT OR CABLE RATED FOR CLASS I, II, DIVISION 2 – NO RIGID CONNECTION PERMITTED. DURING POTENTIAL FREEZING PERIODS INSURE THAT
UNIT IS CONNECTED TO A CONTINUOUS POWER SUPPL Y. AMBIENT TEMPERATURE RATING:
-30°F (-35°C) TO 100°F (38°C)
03/18 Model 7501BLH/7501BL240H Page 2 of 6