Haws 7501 Installation, Operation And Maintenance Manual

INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
HAWS AG Bachweg 3 CH-3401 Burgdorf Switzerland
Avlis-Avenido Senador, Testonio Vilela 505 Jardim Aeroporto Itu, S.P. 13304-550 Brasil
E-mail: haws@hawsco.com
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
HAWS® warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to company within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose, which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions HAWS cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL, PLEASE CALL:
FOR PARTS CALL:
(U.S.A. AND CANADA ONLY) MONDAY-THURSDAY: 6:00 A.M. – 4:00 P.M. PST
Model 7501 Portable Eyewash
LIMITED WARRANTY
1-800-766-5612 1-800-758-9378
FRIDAY: 6:00 A.M – 1:00 P.M. PST
website: www.hawsco.com
No. 2080045(2)
12/06 Model 7501 Page 1 of 5
RECOMMENDED TOOLS: Two 1/4" diameter anchors suitable for supporting filled eyewash (approximately 80 pounds) and tools needed to install these anchors.
LOCATION OF UNIT: The Model 7501 Portable Eyewash should be installed in close proximity to potential accident areas. It should be clearly identified, free from obstructions and easily accessible.
INSTALLATION INSTRUCTIONS
Step 1: Wall mount with “J” Bracket (see Installation Drawing). Eyewash nozzles should
be between 33 inches (83.8 cm) and 45 inches (114.3 cm) above the floor when eye wash arm is in the active (lowered) position.
IMPORTANT:
Filled eyewash unit is heavy (approximately 80 pounds). Wall bracket anchors or
shelf must be strong enough to support the filled eyewash and the weight of a worker leaning on eyewash.
Step 2: Fill up to fill line and place on level surface if possible. If installed as indicated,
eyewash unit will provide 15-minute duration of flow.
Step 3: Take proper precautions to help prevent the growth of potentially harmful
bacteria in eyewash tanks. (Refer to Maintenance Instruction).
OPERATING INSTRUCTIONS
Instruct all employees in the use of this Emergency Eyewash. Personnel should be assigned to check eyewash liquid level daily.
Step 1: Lead patient to nearest eyewash station. Seconds can make the difference in
preventing serious eye injury.
Step 2: Pull yellow eyewash arm firmly. Eyewash arm will drop to activate eyewash. Step 3: Lower head until eyes enter eyewash stream. Use thumbs and forefingers to hold
eyelids open. Flush for 15 minutes.
Step 4: Seek qualified medical attention immediately.
12/06 Model 7501 Page 2 of 5