05/19 Model 7500 Page 2 of 6
RECOMMENDED TOOLS: Three 1/4" diameter anchors suitable for supporting filled
eyewash (approximately 140 pounds) and tools needed to install these anchors.
LOCATION OF UNIT: The Model 7500 Portable Eyewash should be installed in close
proximity to potential accident areas. It should be clearly identified, free from obstructions
and easily accessible. May be wall or shelf mounted.
NOTE: Personal wash units shall be protected from freezing and shall not be exposed
to ambient temperatures exceeding 38⁰C (100⁰F).
INSTALLATION INSTRUCTIONS
STEP 1: Mount unit to wall utilizing “J” bracket (supplied). Note: ¼” mounting hardware not
supplied. Unit can also be mounted on shelf. Make sure portable eyewash unit is
level from front to back and left to right before securing bracket to wall. Eyewash
nozzles should be between 33 inches (83.8 cm) and 45 inches (114.3 cm) above the
floor when eyewash arm is in the active (lowered) position (See Installation Drawing
Page 7 of 7).
IMPORTANT:
Filled eyewash unit is heavy (approximately 140 pounds). Wall bracket anchors,
(Quantity-3, not supplied), or shelf must be strong enough to support the filled
eyewash and the weight of a worker leaning on eyewash.
STEP 2: Install drain hose (supplied), if desired.
STEP 3: Fill up to fill line (make sure that no debris or contaminants of any kind are present in
the flushing fluid). Make sure unit is level from front to back and left to right. If
installed as indicated, eyewash unit will provide 15-minute duration of flow.
STEP 4: Take proper precautions to help prevent the growth of potentially harmful bacteria in
eyewash tanks. (Refer to Maintenance Instructions).
OPERATING INSTRUCTIONS
Instruct all employees in the use of this Emergency Eyewash. Personnel should be assigned to
check eyewash liquid level daily.
STEP 1: Lead patient to nearest eyewash station. Seconds can make the difference in
preventing serious eye injury.
STEP 2: Pull yellow eyewash arm firmly. Eyewash arm will drop to activate eyewash.
STEP 3: Lower head until eyes enter eyewash stream. Use thumbs and forefingers to hold
eyelids open. Flush for 15 minutes.
STEP 4: Seek qualified medical attention immediately.