Do not operate this equipment unless you
have read and understood the contents
of this manual! Failure to follow the
instructions contained in this manual
may result in serious injury or death.
This manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en
este manual puede resultar en un serio
lesión o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted
no puede entender el contenido de
este manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
AVERTISSEMENT
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel ! Le
non-respect des instructions contenues
dans ce manuel peut entraîner de
graves blessures ou la mort. Ce manuel
contient des informations importantes
concernant l’entretien, l’utilisation et le
fonctionnement de ce produit. Si vous ne
comprenez pas le contenu de ce manuel,
veuillez le signaler à votre supérieur.
Conservez ce manuel dans un endroit
sûr pour pouvoir vous y référer plus tard.
Français = p 15
CONTENTS
English
Important Owner Information .............................................. 2
Installing a Remote Control Enclosure ................................ 8
Control Enclosure Cutout Dimensions ................................8
IMPORTANT OWNER INFORMATION
Record the model number, serial number (specification label
located on the back of the unit), voltage, and purchase date
of the unit in the spaces below. Please have this information
available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. _________________________________________
Voltage ___________________________________________
Authorized Parts Distributors ........................... Back Cover
Business
Hours: 7:00 am to 5:00 pm Central Standard Time (CST)
(Summer Hours: June to September—
7:00 am to 5:00 pm CST Monday–Thursday
7:00 am to 4:00 pm CST Friday)
Telephone: 800-558-0607; 414-671-6350
E-mail: partsandservice@hatcocorp.com
Date of Purchase ___________________________________
Register your unit!
Completing online warranty registration will prevent delay in
obtaining warranty coverage. Access the Hatco website at
www.hatcocorp.com, select the Parts & Service pull-down
menu, and click on “Warranty Registration”.
INTRODUCTION
Hatco Modular Built-In Dry Heated Wells are specially designed
to hold heated foods at safe serving temperatures. Dry wells
are available in a variety of pan combinations — all heated
with a long-life heating element that is covered by a 2 year part
warranty. The metal sheathed heating element is controlled
by a remote thermostat. Heat is distributed evenly throughout
the heavy gauge stainless steel construction to ensure hot
food. The design allows for easy maintenance and durable
performance. All units are UL approved and equipped with a
remote control enclosure.
Units are equipped with EZ lock mounting hardware. Controls
include individual lighted power switches and thermostat
controls that retain temperature settings. One year parts and
on-site labor warranty is standard.
Hatco Modular Built-In Dry Heated Wells are a product of
extensive research and field testing. The materials used were
selected for maximum durability, attractive appearance, and
optimum performance. Every unit is inspected and tested
thoroughly prior to shipment.
24 Hour 7 Day Parts and Service
Assistance available in the United States
and Canada by calling 800-558-0607.
Additional information can be found by visiting our web site at
www.hatcocorp.com.
This manual provides the installation, safety, and operating
instructions for the Modular Built-In Dry Heated Wells. Hatco
recommends all installation, operating, and safety instructions
appearing in this manual be read prior to installation or operation
of a unit.
Safety information that appears in this manual is identified by
the following signal word panels:
WARNING
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to
personal injury.
2
Form No. DHWBIM-0417
English
WARNING
CAUTION
WARNING
IMPORTANT SAFETY INFORMATION
Read the following important safety information before using this equipment to avoid serious
injury or death and to avoid damage to equipment or property.
ELECTRIC SHOCK HAZARD:
• Turn power switch OFF, disconnect unit from power
source, and allow unit to cool before performing any
maintenance or cleaning.
• DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged or
saturated with water.
• Unit is not weatherproof. Locate unit indoors where
ambient air temperature is a minimum of 70°F (21°C) and
a maximum of 85°F (29°C).
• Remote control enclosure must be mounted on vertical
wall and installed in vertical position. Mounting remote
control enclosure in horizontal position may result in
collection of liquids and lead to electric shock.
• Do not use unit to melt or hold ice. Doing so may cause
condensation, creating an electrical hazard and causing
personal injury and/or damage to unit. Damage caused by
condensation is not covered by warranty.
• Do not clean unit when it is energized or hot.
• This unit is not “jet-proof” construction. Do not use jetclean spray to clean this unit.
• This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
• Use only Genuine Hatco Replacement Parts when service
is required. Failure to use Genuine Hatco Replacement
Parts will void all warranties and may subject operators
of the equipment to hazardous electrical voltage, resulting
in electrical shock or burn. Genuine Hatco Replacement
Parts are specified to operate safely in the environments
in which they are used. Some aftermarket or generic
replacement parts do not have the characteristics that will
allow them to operate safely in Hatco equipment.
(102 mm) of space from bottom of unit to all noncombustible surfaces. If safe distances are not maintained
combustion could occur.
• Unit must be installed using ribbon putty gasket between
the unit and the installation surface per installation
instructions (refer to the Installation section of this manual).
• Do not use flammable cleaning solutions to clean this
unit.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical codes. Check
with local electrical inspectors for proper procedures and
codes.
This unit is not intended for use by children or persons with
reduced physical, sensory, or mental capabilities. Ensure
proper supervision of children and keep them away from unit.
Make sure all operators have been instructed on the safe and
proper use of unit.
Make sure food product has been heated to the proper foodsafe temperature before placing in the unit. Failure to heat
food product properly may result in serious health risks. This
unit is for holding pre-heated food product only.
Hatco Corporation is not responsible for actual food product
serving temperature. It is the responsibility of the user
to ensure that food product is held and served at a safe
temperature.
This unit has no “user-serviceable” parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
BURN HAZARD:
• Some exterior surfaces on unit will get hot. Use caution
when touching these areas.
• DO NOT clean unit while it contains any food product.
Remove food product and allow unit to cool completely
before cleaning.
Locate unit at proper counter height in an area that is
convenient for use. The location should be strong enough to
support the weight of unit and contents.
NOTICE
Units are voltage-specific. Refer to specification label for
electrical requirements before beginning installation.
Standard and approved manufacturing oils may smoke up to
30 minutes during initial startup. This is a temporary condition.
Operate unit without food product until smoke dissipates.
Do not locate unit in an area subject to excessive temperatures
or grease from grills, fryers, etc. Excessive temperatures
could cause damage to unit.
Unit is designed and recommended for use in or on metallic
countertops. Damage to any countertop material is not
covered under the Hatco warranty. For other surfaces, verify
with manufacturer that material is suitable for prolonged
temperatures up to 200°F (93°C).
Do not use steel wool or metal scouring pad for cleaning.
Steel wool will scratch the finish.
Use non-abrasive cleaners and cloths only. Abrasive cleaners
and cloths could scratch finish of unit, marring its appearance
and making it susceptible to soil accumulation.
Do not use harsh chemicals such as bleach, cleaners
containing bleach, or oven cleaners to clean this unit. Damage
caused by chemicals is not covered by warranty.
Do not locate unit in area with excessive air movement around
unit. Avoid areas that may be subject to active air movements
or currents (i.e., near exhaust fans/hoods, air conditioning
ducts, and exterior doors).
Form No. DHWBIM-0417
3
MODEL DESCRIPTION
DHWBI-1
DHWBI-4
DHWBI-3
DHWBI-5
DHWBI-2
DHWBI-6
English
All Models
All Modular Built-In Dry Heated Well units are reliable and
versatile. Each unit has an insulated, stainless steel and
aluminized steel housing with a metal sheathed heating element.
The heating element is controlled with a thermostatic temperature
control and a lighted POWER ON/OFF switch housed in a remote
control enclosure. The air heating/circulation system provides
a consistent temperature in each well. The remote control
enclosure is connected to the unit with a 6′ (1829 mm) flexible
conduit assembly. Modular Built-In Dry Heated Wells can come
with a power cord or be hardwired directly to a power source for
a secure and cord-free serving area.
All models are equipped with EZ locking hardware and designed
to be mounted to the topside of a non-combustible countertop.
Modular Built-In Dry Heated Wells are designed, manufactured,
and tested to maintain safe food holding temperatures.
DHWBI-1, -2, -3, -4, -5, and -6 Models
DHWBI models are capable of holding a variety of pan
combinations in each heated well.
• One full size pan
• Two 1/2-size pans with adapter bars.
• Three 1/3-size pans with adapter bars.
• Six 1/6-size pans with adapter bars.
• Two 7 quart round pans with adapter top.
• Three 4 quart round pans with adapter top.
Food Pans, Pan Support Bars, and Adapter Tops sold
separately (refer to the OPTIONS AND ACCESSORIES section
in this manual).
IMPORTANT NOTE
Remote control enclosures must be mounted
on the front of the unit to ensure the controls
correspond with the correct wells (the front of the
unit is the side the conduit enters under the unit).
Remote control enclosures cannot be rewired and
must be installed in the proper location.
NOTE: Split controls also available. All models for Canada require
controls in a single control enclosure.
4
Form No. DHWBIM-0417
English
NEMA 5-15PNEMA 5-20P
NEMA 5-30P
NEMA L14-20P
Full-Size Pan Capacity
Insulated Top Mount
D H W B I - x
Dry Heated Well
Built-In
Plug Configurations
Some units are supplied from the factory with an electrical
cord and plug installed. Plugs are supplied according to the
application (not available with split controls). Refer to the
OPTIONS AND ACCESSORIES section for more information.
MODEL DESIGNATION
SPECIFICATIONS
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install the proper voltage and size electrical receptacle.
NOTE: Specification label located on side of the unit. See
label for serial number and verification of unit electrical
information.
NOTE: Receptacle not supplied by Hatco.
Plug Configurations
Electrical Rating Chart
Plug Configuration
ModelVoltageHertzWattsAmps
DHWBI-1120609608.0NEMA 5-15P48 lbs. (22 kg)
DHWBI-212060192016.0NEMA 5-20P93 lbs. (42 kg)
120/208–2406019208.0NEMA L14-20P93 lbs. (42 kg)
DHWBI-312060288024.0NEMA 5-30P133 lbs. (60 kg)
120/208–24060288016.0NEMA L14-20P133 lbs. (60 kg)
DHWBI-4120/208–24060384016.0NEMA L14-20P172 lbs. (78 kg)
DHWBI-5120/208–24060480024.0N/A217 lbs. (98 kg)
DHWBI-6120/208–24060576024.0N/A250 lbs. (114 kg)
(optional)Shipping Weight
NOTE: Shipping Weights are estimated.
Form No. DHWBIM-0417
5
SPECIFICATIONS
Side View
Front View
A
5/16″
(8 mm)
Flange
B
C
WARNING
CAUTION
Dimensions
Width
Model
(A)
Depth
(B) *
Height
(C)
Model
Width
(A)
Depth
(B) *
English
Height
(C)
DHWBI-1
DHWBI-2
DHWBI-3
* Units with over-sized bezel option have a Depth (B) of 27″ (686 mm).
15-1/2″
(394 mm)
29-1/2″
(749 mm)
43-1/2″
(1105 mm)
23-5/8″
(600 mm)
23-5/8″
(600 mm)
23-5/8″
(600 mm)
12-11/16″
(321 mm)
12-11/16″
(321 mm)
12-11/16″
(321 mm)
DHWBI-4
DHWBI-5
DHWBI-6
INSTALLATION
General
Modular Built-In Dry Heated Wells are shipped from the factory
with most components assembled and ready for use. Use the
following procedures to install the unit.
NOTE: All Modular Built-In Dry Heated Wells require the
control enclosure to be remote mounted.
NOTE: Make sure the installation location provides enough
room for the remote mounted control enclosure and
electrical connections.
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C) and a maximum of 85°F (29°C).
combustible surfaces. If safe distances are not
maintained combustion could occur.
• Unit must be installed using ribbon putty gasket
between the unit and the installation surface per
installation instructions.
This unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Check with local plumbing and electrical
inspectors for proper procedures and codes.
Locate unit at proper counter height in an area that is
convenient for use. The location should be strong enough
to support the weight of unit and contents.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Unit is designed and recommended for use in or on
metallic countertops. Damage to any countertop material
is not covered under the Hatco warranty. For other
surfaces, verify with manufacturer that material is suitable
for prolonged temperatures up to 200°F (93°C).
1. Remove the unit from the box.
NOTE: To prevent delay in obtaining warranty coverage,
2. Remove tape and protective packaging from all surfaces
NOTE: A qualified electrician should connect the unit(s) to a
3. Install the unit in the desired location. Refer to the
4. Install the remote control enclosure Refer to the “Installing
5. Provide a catch pan for the overflow drain pipe on the
• The 3/4″ overflow drain pipe also can be connected to
NOTE: Liquid will drain only if spilled into well.
57-1/2″
(1461 mm)
71-1/2″
(1816 mm)
85-1/2″
(2172 mm)
23-5/8″
(600 mm)
23-5/8″
(600 mm)
23-5/8″
(600 mm)
12-11/16″
(321 mm)
12-11/16″
(321 mm)
12-11/16″
(321 mm)
NOTICE
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
of unit.
power source.
“Installing the Unit” procedure in this section.
a Remote Control Enclosure” procedure in this section.
bottom of the unit. DO NOT allow drained liquids to
contact the conduit.
an on-site drain line. Consult a licensed plumber for
proper drain installation that conforms to local codes.
6
Form No. DHWBIM-0417
English
Ribbon Putty Gasket
Cutout edge of countertop.
Countertop
EZ Locking
Tab
Countertop
B
A
Countertop
INSTALLATION
Installing the Unit
NOTE: Cut the opening for both the unit and the control
enclosure(s) before placing unit into the countertop
opening.
1. Cut the appropriate opening in the countertop. Refer to the
“Countertop Cutout” chart in this section.
2. Cut the appropriate opening for the control enclosure(s).
Refer to the “Control Enclosure Cutout Dimensions” chart
in this section.
3. Place ribbon putty gasket around the cutout edge of the
countertop. Make sure the ribbon putty gasket overhangs
the cutout edge or seal unit with silicone adhesive.
NOTE: A roll of ribbon putty gasket material is supplied with the
unit.
Countertop Cutout Dimensions
ModelWidth (A)Depth (B)
DHWBI-1
DHWBI-2
DHWBI-3
DHWBI-4
DHWBI-5
DHWBI-6
14-1/8″ – 14-3/8″
(359 – 365 mm)
28-1/8″ – 28-3/8″
(715 – 720 mm)
42-1/8″ – 42-3/8″
(1070 – 1076 mm)
56-1/8″ – 56-3/8″
(1426 – 1431 mm)
70-1/8″ – 70-3/8″
(1782 – 1787 mm)
84-1/8″ – 84-3/8″
(2137 – 2143 mm)
22-1/4″ – 22-1/2″
(566 – 571 mm)
22-1/4″ – 22-1/2″
(566 – 571 mm)
22-1/4″ – 22-1/2″
(566 – 571 mm)
22-1/4″ – 22-1/2″
(566 – 571 mm)
22-1/4″ – 22-1/2″
(566 – 571 mm)
22-1/4″ – 22-1/2″
(566 – 571 mm)
4. Place the unit into the countertop opening.
5. Using a screwdriver, rotate the unit’s EZ locking tabs
NOTE: The Hatco EZ locking tabs work on countertops
6. Carefully trim and remove the excess ribbon putty material
7. Install the control enclosure(s). Refer to the “Installing a
Installing Ribbon Putty Gasket
outward to secure the unit to the underside of the
countertop. Rotate as many tabs as needed to secure the
unit to the countertop.
EZ Locking Tabs
that have a maximum thickness of 3/16″ (5 mm).
For countertops 3/16″–2″ (5–51 mm) thick, use an
appropriate number of accessory thick counter adapter
brackets (HWB-MNT-REC ). Refer to the OPTIONS AND ACCESSORIES section for Adapter Bracket
installation information.
from around the unit.
Remote Control Enclosure” procedure in this section.
Countertop Cutout Dimensions
NOTE: Required minimum clearance below countertop
cutout is 16-3/16″ (411 mm) when installing around
combustible surfaces and 13-11/16″ (348 mm) around
non-combustible surfaces.
Form No. DHWBIM-0417
7
Typical knockout
locations for power
source connection.
Control
Enclosure
A
C
D
B
Side View –
Control Enclosure
5-5/16″
(135 mm)
1-1/2″
(38 mm)
Silicone Sealant
7/16″
(11 mm)
3/8″
(9 mm)
INSTALLATION
English
Installing a Remote Control Enclosure
Remote control enclosures must be mounted on the front of
the unit to ensure the controls correspond with the correct wells
(the front of the unit is the side the conduit enters under the
unit). Remote control enclosures cannot be rewired and must
be installed in the proper location.
WARNING
ELECTRIC SHOCK HAZARD: Remote control enclosure
must be mounted on vertical wall and installed in vertical
position. Mounting remote control enclosure in horizontal
position may result in collection of liquids and lead to
electric shock.
NOTE: A qualified electrician should connect the unit(s) to a
power source.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the “Control Enclosure Cutout Dimensions” chart
below for the cutout dimensions for each control enclosure.
• The cutout depth required for all control enclosures is
6-1/8″ (153 mm).
• Make sure to have enough space inside the cutout if
installing with conduit on the side of the control enclosure.
• For units with two control enclosures: Each enclosure
cutout size will be different (see chart below).
2. Remove the trim cover from the control enclosure.
3. Position the control enclosure into the opening through the
backside.
4. Secure the control enclosure to the mounting surface
using screws (#8 sheet metal screw supplied).
5. Connect the proper power
source to the mounted
remote control enclosure.
Wiring must be fixed a
minimum of 4″ (102 mm)
from bottom of well(s).
6. Apply a 1/4″ (6 mm) bead
of NSF-approved silicone
sealant where the trim cover
will contact the cabinet surface. Refer to the “Control
Enclosure Cutout and Screw Hole Dimensions” illustration
for more information.
7. Reinstall the trim cover on the control enclosure and
secure in position using the four trim cover screws. Make
sure to embed the trim cover edge into the silicone.
NOTE: Standard UL approved units are equipped with a
72″ (1829 mm) flexible conduit connected to the remote
control enclosure.
Control Enclosure Cutout Dimensions
Opening
Model
DHWBI-1
DHWBI-2
DHWBI-3
DHWBI-4
DHWBI-5
DHWBI-6
Dimension
Width (A)
6-5/16″
(160 mm)
10-5/16″
(262 mm)
14-5/16″
(364 mm)
18-5/16″
(465 mm)
22-5/16″
(567 mm)
26-5/16″
(668 mm)
Opening
Dimension
Height (B)
4-3/4″
(119 mm)
4-3/4″
(119 mm)
4-3/4″
(119 mm)
4-3/4″
(119 mm)
4-3/4″
(119 mm)
4-3/4″
(119 mm)
Control Enclosure Cutout and Screw Hole Dimensions
Screw Hole
Dimension
Width (C)
6-9/16″
(167 mm)
10-9/16″
(269 mm)
14-9/16″
(370 mm)
18-9/16″
(472 mm)
22-9/16″
(573 mm)
26-9/16″
(675 mm)
8
Screw Hole
Dimension
Height (D)
2-1/2″
(64 mm)
2-1/2″
(64 mm)
2-1/2″
(64 mm)
2-1/2″
(64 mm)
2-1/2″
(64 mm)
2-1/2″
(64 mm)
IMPORTANT NOTE:
Make sure the installation location
provides enough room for electrical
connections to the control enclosure.
Follow local and national plumbing
and electrical codes.
Form No. DHWBIM-0417
English
WARNING
Temperature Control
Knob
Power I/O (on/off)
Switch
OPERATION
General
Use the following procedures to operate the Modular Built-In
Dry Heated Wells.
Read all safety messages in the Important Safety
Information section before operating this equipment.
ELECTRIC SHOCK HAZARD: Do not use unit to melt or
hold ice. Doing so may cause condensation, creating
an electrical hazard and causing personal injury and/or
damage to unit. Damage caused by condensation is not
covered by warranty.
NOTICE
Standard and approved manufacturing oils may smoke up
to 30 minutes during initial startup. This is a temporary
condition. Operate unit without food product until smoke
dissipates.
Startup
1. Prepare the wells for operation.
2. Place an empty pan in each well or cover each well with
a lid. This step is recommended to speed up pre-heating
and reach operating temperature.
3. Move the Power I/O (on/off) switch(es) to the I (on)
position. The indicator light on each switch glows when it
is on.
Food Warming
Place the appropriate size food pans with pre-heated food
product into the Dry Heated Wells.
• Always use a food pan. Do not place food directly into the
heated well.
• Keep pans covered to maintain food quality and
temperature.
Shutdown
1. Move the Power I/O (on/off) switches to the O (off) position.
The indicator light on the switches will shut off.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the catch pan is emptied after each spill to prevent
overflowing.
CAUTION
BURN HAZARD: Some exterior surfaces on the unit will
get hot. Use caution when touching these areas.
4. Turn the Temperature Control Knob(s) to the desired
setting to ensure safe food temperature.
WARNING
Hatco Corporation is not responsible for actual food
product serving temperature. It is the responsibility of the
user to ensure that food product is held and served at a
safe temperature.
5. Allow the unit to preheat for approximately 30 minutes.
Form No. DHWBIM-0417
Control Enclosure
9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.