Hatco DHWBI-1 Installation Manual

hatcocorp.com
ADVERTENCIA
Register Online!
S’inscrire en ligne!
(voir page 15)
Modular Built-In Insulated Dry Heated Wells
Puits chauffants secs modulaires intégrés
avec isolation
DHWBI Series • Série DHWBI
Installation and Operating Manual
Manuel d’installation et d’utilisation
Do not operate this equipment unless you have read and understood the contents of this manual! Failure to follow the instructions contained in this manual may result in serious injury or death. This manual contains important safety information concerning the maintenance, use, and operation of this product. If you’re unable to understand the contents of this manual, please bring it to the attention of your supervisor. Keep this manual in a safe location for future reference.
P/N 07.04.814.00 © 2017 Hatco Corporation
WARNING
English = p 2
No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte. Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto. Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor. Almacenar este manual en una localización segura para la referencia futura.
AVERTISSEMENT
Ne pas utiliser cet équipement sans avoir lu et compris le contenu de ce manuel ! Le non-respect des instructions contenues dans ce manuel peut entraîner de graves blessures ou la mort. Ce manuel contient des informations importantes concernant l’entretien, l’utilisation et le fonctionnement de ce produit. Si vous ne comprenez pas le contenu de ce manuel, veuillez le signaler à votre supérieur. Conservez ce manuel dans un endroit sûr pour pouvoir vous y référer plus tard.
Français = p 15
CONTENTS
English
Important Owner Information .............................................. 2
Introduction ...........................................................................2
Important Safety Information .............................................. 3
Model Description ................................................................4
Model Designation ...............................................................5
Specifications ....................................................................... 5
Plug Configurations ............................................................. 5
Electrical Rating Chart ......................................................... 5
Dimensions .......................................................................... 6
Installation .............................................................................6
General ................................................................................ 6
Installing the Unit ................................................................. 7
Countertop Cutout Dimensions ...........................................7
Installing a Remote Control Enclosure ................................ 8
Control Enclosure Cutout Dimensions ................................8
IMPORTANT OWNER INFORMATION
Record the model number, serial number (specification label located on the back of the unit), voltage, and purchase date of the unit in the spaces below. Please have this information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. _________________________________________
Voltage ___________________________________________
Operation ...............................................................................9
General ................................................................................ 9
Maintenance ........................................................................ 10
General .............................................................................. 10
Daily Cleaning ...................................................................10
Monthly Cleaning ............................................................... 10
Troubleshooting Guide ...................................................... 11
Options and Accessories .................................................. 12
Limited Warranty ................................................................14
Authorized Parts Distributors ........................... Back Cover
Business Hours: 7:00 am to 5:00 pm Central Standard Time (CST)
(Summer Hours: June to September 7:00 am to 5:00 pm CST Monday–Thursday 7:00 am to 4:00 pm CST Friday)
Telephone: 800-558-0607; 414-671-6350
E-mail: partsandservice@hatcocorp.com
Date of Purchase ___________________________________
Register your unit!
Completing online warranty registration will prevent delay in obtaining warranty coverage. Access the Hatco website at www.hatcocorp.com, select the Parts & Service pull-down menu, and click on “Warranty Registration”.
INTRODUCTION
Hatco Modular Built-In Dry Heated Wells are specially designed to hold heated foods at safe serving temperatures. Dry wells are available in a variety of pan combinations — all heated with a long-life heating element that is covered by a 2 year part warranty. The metal sheathed heating element is controlled by a remote thermostat. Heat is distributed evenly throughout the heavy gauge stainless steel construction to ensure hot food. The design allows for easy maintenance and durable performance. All units are UL approved and equipped with a remote control enclosure.
Units are equipped with EZ lock mounting hardware. Controls include individual lighted power switches and thermostat controls that retain temperature settings. One year parts and on-site labor warranty is standard.
Hatco Modular Built-In Dry Heated Wells are a product of extensive research and field testing. The materials used were selected for maximum durability, attractive appearance, and optimum performance. Every unit is inspected and tested thoroughly prior to shipment.
24 Hour 7 Day Parts and Service Assistance available in the United States and Canada by calling 800-558-0607.
Additional information can be found by visiting our web site at www.hatcocorp.com.
This manual provides the installation, safety, and operating instructions for the Modular Built-In Dry Heated Wells. Hatco recommends all installation, operating, and safety instructions appearing in this manual be read prior to installation or operation of a unit.
Safety information that appears in this manual is identified by the following signal word panels:
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to personal injury.
2
Form No. DHWBIM-0417
English
WARNING
CAUTION
WARNING
IMPORTANT SAFETY INFORMATION
Read the following important safety information before using this equipment to avoid serious injury or death and to avoid damage to equipment or property.
ELECTRIC SHOCK HAZARD:
• Turn power switch OFF, disconnect unit from power source, and allow unit to cool before performing any maintenance or cleaning.
• DO NOT submerge or saturate with water. Unit is not waterproof. Do not operate if unit has been submerged or saturated with water.
• Unit is not weatherproof. Locate unit indoors where ambient air temperature is a minimum of 70°F (21°C) and a maximum of 85°F (29°C).
• Remote control enclosure must be mounted on vertical wall and installed in vertical position. Mounting remote control enclosure in horizontal position may result in collection of liquids and lead to electric shock.
• Do not use unit to melt or hold ice. Doing so may cause condensation, creating an electrical hazard and causing personal injury and/or damage to unit. Damage caused by condensation is not covered by warranty.
• Do not clean unit when it is energized or hot.
• This unit is not “jet-proof” construction. Do not use jet­clean spray to clean this unit.
• This unit must be serviced by qualified personnel only. Service by unqualified personnel may lead to electric shock or burn.
• Use only Genuine Hatco Replacement Parts when service is required. Failure to use Genuine Hatco Replacement Parts will void all warranties and may subject operators of the equipment to hazardous electrical voltage, resulting in electrical shock or burn. Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used. Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment.
FIRE HAZARD:
 • Install unit withaminimum of 3-1/2″ (89mm) of space
from bottom of unit to all combustible surfaces or 1″
(102 mm) of space from bottom of unit to all non­combustible surfaces. If safe distances are not maintained combustion could occur.
• Unit must be installed using ribbon putty gasket between the unit and the installation surface per installation instructions (refer to the Installation section of this manual).
• Do not use flammable cleaning solutions to clean this unit.
This unit must be installed by qualified, trained installers. Installation must conform to all local electrical codes. Check with local electrical inspectors for proper procedures and codes.
This unit is not intended for use by children or persons with reduced physical, sensory, or mental capabilities. Ensure proper supervision of children and keep them away from unit.
Make sure all operators have been instructed on the safe and proper use of unit.
Make sure food product has been heated to the proper food­safe temperature before placing in the unit. Failure to heat food product properly may result in serious health risks. This unit is for holding pre-heated food product only.
Hatco Corporation is not responsible for actual food product serving temperature. It is the responsibility of the user to ensure that food product is held and served at a safe temperature.
This unit has no “user-serviceable” parts. If service is required on this unit, contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350.
BURN HAZARD:
• Some exterior surfaces on unit will get hot. Use caution when touching these areas.
• DO NOT clean unit while it contains any food product. Remove food product and allow unit to cool completely before cleaning.
Locate unit at proper counter height in an area that is convenient for use. The location should be strong enough to support the weight of unit and contents.
NOTICE
Units are voltage-specific. Refer to specification label for electrical requirements before beginning installation.
Standard and approved manufacturing oils may smoke up to 30 minutes during initial startup. This is a temporary condition. Operate unit without food product until smoke dissipates.
Do not locate unit in an area subject to excessive temperatures or grease from grills, fryers, etc. Excessive temperatures could cause damage to unit.
Unit is designed and recommended for use in or on metallic countertops. Damage to any countertop material is not covered under the Hatco warranty. For other surfaces, verify with manufacturer that material is suitable for prolonged temperatures up to 200°F (93°C).
Do not use steel wool or metal scouring pad for cleaning. Steel wool will scratch the finish.
Use non-abrasive cleaners and cloths only. Abrasive cleaners and cloths could scratch finish of unit, marring its appearance and making it susceptible to soil accumulation.
Do not use harsh chemicals such as bleach, cleaners containing bleach, or oven cleaners to clean this unit. Damage caused by chemicals is not covered by warranty.
Do not locate unit in area with excessive air movement around unit. Avoid areas that may be subject to active air movements or currents (i.e., near exhaust fans/hoods, air conditioning ducts, and exterior doors).
Form No. DHWBIM-0417
3
MODEL DESCRIPTION
DHWBI-1
DHWBI-4
DHWBI-3
DHWBI-5
DHWBI-2
DHWBI-6
English
All Models
All Modular Built-In Dry Heated Well units are reliable and versatile. Each unit has an insulated, stainless steel and aluminized steel housing with a metal sheathed heating element. The heating element is controlled with a thermostatic temperature control and a lighted POWER ON/OFF switch housed in a remote control enclosure. The air heating/circulation system provides a consistent temperature in each well. The remote control
enclosure is connected to the unit with a 6′ (1829 mm) flexible
conduit assembly. Modular Built-In Dry Heated Wells can come with a power cord or be hardwired directly to a power source for a secure and cord-free serving area.
All models are equipped with EZ locking hardware and designed to be mounted to the topside of a non-combustible countertop. Modular Built-In Dry Heated Wells are designed, manufactured, and tested to maintain safe food holding temperatures.
DHWBI-1, -2, -3, -4, -5, and -6 Models
DHWBI models are capable of holding a variety of pan combinations in each heated well.
• One full size pan
• Two 1/2-size pans with adapter bars.
• Three 1/3-size pans with adapter bars.
• Six 1/6-size pans with adapter bars.
• Two 7 quart round pans with adapter top.
• Three 4 quart round pans with adapter top. Food Pans, Pan Support Bars, and Adapter Tops sold
separately (refer to the OPTIONS AND ACCESSORIES section in this manual).
IMPORTANT NOTE
Remote control enclosures must be mounted on the front of the unit to ensure the controls correspond with the correct wells (the front of the unit is the side the conduit enters under the unit). Remote control enclosures cannot be rewired and must be installed in the proper location.
NOTE: Split controls also available. All models for Canada require
controls in a single control enclosure.
4
Form No. DHWBIM-0417
English
NEMA 5-15P NEMA 5-20P
NEMA 5-30P
NEMA L14-20P
Full-Size Pan Capacity Insulated Top Mount
D H W B I - x
Dry Heated Well
Built-In
Plug Configurations
Some units are supplied from the factory with an electrical cord and plug installed. Plugs are supplied according to the application (not available with split controls). Refer to the OPTIONS AND ACCESSORIES section for more information.
MODEL DESIGNATION
SPECIFICATIONS
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly grounded electrical receptacle of the correct voltage, size, and plug configuration. If plug and receptacle do not match, contact a qualified electrician to determine and install the proper voltage and size electrical receptacle.
NOTE: Specification label located on side of the unit. See
label for serial number and verification of unit electrical information.
NOTE: Receptacle not supplied by Hatco.
Plug Configurations
Electrical Rating Chart
Plug Configuration
Model Voltage Hertz Watts Amps
DHWBI-1 120 60 960 8.0 NEMA 5-15P 48 lbs. (22 kg) DHWBI-2 120 60 1920 16.0 NEMA 5-20P 93 lbs. (42 kg)
120/208–240 60 1920 8.0 NEMA L14-20P 93 lbs. (42 kg)
DHWBI-3 120 60 2880 24.0 NEMA 5-30P 133 lbs. (60 kg)
120/208–240 60 2880 16.0 NEMA L14-20P 133 lbs. (60 kg) DHWBI-4 120/208–240 60 3840 16.0 NEMA L14-20P 172 lbs. (78 kg) DHWBI-5 120/208–240 60 4800 24.0 N/A 217 lbs. (98 kg) DHWBI-6 120/208–240 60 5760 24.0 N/A 250 lbs. (114 kg)
(optional) Shipping Weight
NOTE: Shipping Weights are estimated.
Form No. DHWBIM-0417
5
SPECIFICATIONS
Side View
Front View
A
5/16″ (8 mm) Flange
B
C
WARNING
CAUTION
Dimensions
Width
Model
(A)
Depth
(B) *
Height
(C)
Model
Width
(A)
Depth
(B) *
English
Height
(C)
DHWBI-1
DHWBI-2
DHWBI-3
* Units with over-sized bezel option have a Depth (B) of 27″ (686 mm).
15-1/2
(394 mm)
29-1/2
(749 mm)
43-1/2
(1105 mm)
23-5/8
(600 mm)
23-5/8
(600 mm)
23-5/8
(600 mm)
12-11/16 (321 mm)
12-11/16 (321 mm)
12-11/16 (321 mm)
DHWBI-4
DHWBI-5
DHWBI-6
INSTALLATION
General
Modular Built-In Dry Heated Wells are shipped from the factory with most components assembled and ready for use. Use the following procedures to install the unit.
NOTE: All Modular Built-In Dry Heated Wells require the
control enclosure to be remote mounted.
NOTE: Make sure the installation location provides enough
room for the remote mounted control enclosure and electrical connections.
ELECTRIC SHOCK HAZARD: Unit is not weatherproof. Locate unit indoors where ambient air temperature is a minimum of 70°F (21°C) and a maximum of 85°F (29°C).
FIRE HAZARD:
 • Installunitwithaminimumof3-1/2″(89mm)ofspace
from bottom of unit to all combustible surfaces or
1″(102mm)of space from bottom ofunittoallnon-
combustible surfaces. If safe distances are not maintained combustion could occur.
• Unit must be installed using ribbon putty gasket between the unit and the installation surface per installation instructions.
This unit must be installed by qualified, trained installers. Installation must conform to all local electrical and plumbing codes. Check with local plumbing and electrical inspectors for proper procedures and codes.
Locate unit at proper counter height in an area that is convenient for use. The location should be strong enough to support the weight of unit and contents.
Do not locate unit in an area subject to excessive temperatures or grease from grills, fryers, etc. Excessive temperatures could cause damage to the unit.
Unit is designed and recommended for use in or on metallic countertops. Damage to any countertop material is not covered under the Hatco warranty. For other surfaces, verify with manufacturer that material is suitable for prolonged temperatures up to 200°F (93°C).
1. Remove the unit from the box.
NOTE: To prevent delay in obtaining warranty coverage,
2. Remove tape and protective packaging from all surfaces
NOTE: A qualified electrician should connect the unit(s) to a
3. Install the unit in the desired location. Refer to the
4. Install the remote control enclosure Refer to the “Installing
5. Provide a catch pan for the overflow drain pipe on the
• The 3/4″ overflow drain pipe also can be connected to
NOTE: Liquid will drain only if spilled into well.
57-1/2
(1461 mm)
71-1/2
(1816 mm)
85-1/2
(2172 mm)
23-5/8
(600 mm)
23-5/8
(600 mm)
23-5/8
(600 mm)
12-11/16 (321 mm)
12-11/16 (321 mm)
12-11/16 (321 mm)
NOTICE
complete online warranty registration. See the IMPORTANT OWNER INFORMATION section for details.
of unit.
power source.
“Installing the Unit” procedure in this section.
a Remote Control Enclosure” procedure in this section.
bottom of the unit. DO NOT allow drained liquids to
contact the conduit.
an on-site drain line. Consult a licensed plumber for proper drain installation that conforms to local codes.
6
Form No. DHWBIM-0417
English
Ribbon Putty Gasket
Cutout edge of countertop.
Countertop
EZ Locking Tab
Countertop
B
A
Countertop
INSTALLATION
Installing the Unit
NOTE: Cut the opening for both the unit and the control
enclosure(s) before placing unit into the countertop opening.
1. Cut the appropriate opening in the countertop. Refer to the “Countertop Cutout” chart in this section.
2. Cut the appropriate opening for the control enclosure(s). Refer to the “Control Enclosure Cutout Dimensions” chart in this section.
3. Place ribbon putty gasket around the cutout edge of the countertop. Make sure the ribbon putty gasket overhangs the cutout edge or seal unit with silicone adhesive.
NOTE: A roll of ribbon putty gasket material is supplied with the
unit.
Countertop Cutout Dimensions
Model Width (A) Depth (B)
DHWBI-1
DHWBI-2
DHWBI-3
DHWBI-4
DHWBI-5
DHWBI-6
14-1/8 – 14-3/8
(359 – 365 mm)
28-1/8 – 28-3/8
(715 – 720 mm)
42-1/8 – 42-3/8
(1070 – 1076 mm)
56-1/8 – 56-3/8
(1426 – 1431 mm)
70-1/8 – 70-3/8
(1782 – 1787 mm)
84-1/8 – 84-3/8
(2137 – 2143 mm)
22-1/4 – 22-1/2
(566 – 571 mm)
22-1/4 – 22-1/2
(566 – 571 mm)
22-1/4 – 22-1/2
(566 – 571 mm)
22-1/4 – 22-1/2
(566 – 571 mm)
22-1/4 – 22-1/2
(566 – 571 mm)
22-1/4 – 22-1/2
(566 – 571 mm)
4. Place the unit into the countertop opening.
5. Using a screwdriver, rotate the unit’s EZ locking tabs
NOTE: The Hatco EZ locking tabs work on countertops
6. Carefully trim and remove the excess ribbon putty material
7. Install the control enclosure(s). Refer to the “Installing a
Installing Ribbon Putty Gasket
outward to secure the unit to the underside of the countertop. Rotate as many tabs as needed to secure the unit to the countertop.
EZ Locking Tabs
that have a maximum thickness of 3/16″ (5 mm). For countertops 3/16″–2″ (5–51 mm) thick, use an
appropriate number of accessory thick counter adapter brackets (HWB-MNT-REC ). Refer to the OPTIONS AND ACCESSORIES section for Adapter Bracket installation information.
from around the unit.
Remote Control Enclosure” procedure in this section.
Countertop Cutout Dimensions
NOTE: Required minimum clearance below countertop
cutout is 16-3/16″ (411 mm) when installing around combustible surfaces and 13-11/16″ (348 mm) around
non-combustible surfaces.
Form No. DHWBIM-0417
7
Typical knockout locations for power source connection.
Control
Enclosure
A
C
D
B
Side View –
Control Enclosure
5-5/16″
(135 mm)
1-1/2″
(38 mm)
Silicone Sealant
7/16″
(11 mm)
3/8″
(9 mm)
INSTALLATION
English
Installing a Remote Control Enclosure
Remote control enclosures must be mounted on the front of the unit to ensure the controls correspond with the correct wells (the front of the unit is the side the conduit enters under the unit). Remote control enclosures cannot be rewired and must be installed in the proper location.
WARNING
ELECTRIC SHOCK HAZARD: Remote control enclosure must be mounted on vertical wall and installed in vertical position. Mounting remote control enclosure in horizontal position may result in collection of liquids and lead to electric shock.
NOTE: A qualified electrician should connect the unit(s) to a
power source.
1. Cut and drill the appropriate holes in the mounting surface. Refer to the “Control Enclosure Cutout Dimensions” chart below for the cutout dimensions for each control enclosure.
• The cutout depth required for all control enclosures is
6-1/8″ (153 mm).
• Make sure to have enough space inside the cutout if
installing with conduit on the side of the control enclosure.
• For units with two control enclosures: Each enclosure
cutout size will be different (see chart below).
2. Remove the trim cover from the control enclosure.
3. Position the control enclosure into the opening through the backside.
4. Secure the control enclosure to the mounting surface using screws (#8 sheet metal screw supplied).
5. Connect the proper power source to the mounted remote control enclosure. Wiring must be fixed a
minimum of 4″ (102 mm)
from bottom of well(s).
6. Apply a 1/4″ (6 mm) bead
of NSF-approved silicone sealant where the trim cover will contact the cabinet surface. Refer to the “Control Enclosure Cutout and Screw Hole Dimensions” illustration for more information.
7. Reinstall the trim cover on the control enclosure and secure in position using the four trim cover screws. Make sure to embed the trim cover edge into the silicone.
NOTE: Standard UL approved units are equipped with a
72″ (1829 mm) flexible conduit connected to the remote
control enclosure.
Control Enclosure Cutout Dimensions
Opening
Model
DHWBI-1
DHWBI-2
DHWBI-3
DHWBI-4
DHWBI-5
DHWBI-6
Dimension
Width (A)
6-5/16
(160 mm)
10-5/16
(262 mm)
14-5/16
(364 mm)
18-5/16
(465 mm)
22-5/16
(567 mm)
26-5/16
(668 mm)
Opening
Dimension
Height (B)
4-3/4
(119 mm)
4-3/4
(119 mm)
4-3/4
(119 mm)
4-3/4
(119 mm)
4-3/4
(119 mm)
4-3/4
(119 mm)
Control Enclosure Cutout and Screw Hole Dimensions
Screw Hole
Dimension
Width (C)
6-9/16
(167 mm)
10-9/16
(269 mm)
14-9/16
(370 mm)
18-9/16
(472 mm)
22-9/16
(573 mm)
26-9/16
(675 mm)
8
Screw Hole
Dimension
Height (D)
2-1/2
(64 mm)
2-1/2
(64 mm)
2-1/2
(64 mm)
2-1/2
(64 mm)
2-1/2
(64 mm)
2-1/2
(64 mm)
IMPORTANT NOTE:
Make sure the installation location provides enough room for electrical connections to the control enclosure. Follow local and national plumbing and electrical codes.
Form No. DHWBIM-0417
English
WARNING
Temperature Control Knob
Power I/O (on/off)
Switch
OPERATION
General
Use the following procedures to operate the Modular Built-In Dry Heated Wells.
Read all safety messages in the Important Safety Information section before operating this equipment.
ELECTRIC SHOCK HAZARD: Do not use unit to melt or hold ice. Doing so may cause condensation, creating an electrical hazard and causing personal injury and/or damage to unit. Damage caused by condensation is not covered by warranty.
NOTICE
Standard and approved manufacturing oils may smoke up to 30 minutes during initial startup. This is a temporary condition. Operate unit without food product until smoke dissipates.
Startup
1. Prepare the wells for operation.
2. Place an empty pan in each well or cover each well with a lid. This step is recommended to speed up pre-heating and reach operating temperature.
3. Move the Power I/O (on/off) switch(es) to the I (on) position. The indicator light on each switch glows when it is on.
Food Warming
Place the appropriate size food pans with pre-heated food product into the Dry Heated Wells.
• Always use a food pan. Do not place food directly into the heated well.
• Stir thick food items frequently to keep food heated uniformly.
• Keep pans covered to maintain food quality and temperature.
Shutdown
1. Move the Power I/O (on/off) switches to the O (off) position. The indicator light on the switches will shut off.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the catch pan is emptied after each spill to prevent overflowing.
CAUTION
BURN HAZARD: Some exterior surfaces on the unit will get hot. Use caution when touching these areas.
4. Turn the Temperature Control Knob(s) to the desired setting to ensure safe food temperature.
WARNING
Hatco Corporation is not responsible for actual food product serving temperature. It is the responsibility of the user to ensure that food product is held and served at a safe temperature.
5. Allow the unit to preheat for approximately 30 minutes.
Form No. DHWBIM-0417
Control Enclosure
9
Loading...
+ 19 hidden pages