PRODUCT SPECIFICATIONS
Item Description
Electrical Requiremen ts One 9-Volt B attery (Not Included)
Display 3-1/2 D igit with a M aximum D isplay Reading of 1999
Measuring Range 1 ~ 2,000, 20,000, 50,0 00 Lux
Repeatability ±2%
Overrange Display The Highest Display Digit “1”
Accuracy ±4% Reading ±0.5% Full-Scale
±4% Reading ±5 digit (10,000 -50,000 Lux)
±5% Reading ±10 digit (50,000+ Lux)
Measuring Rate 2.0 times/sec.
Photo Detector One S ilicon Photo Diode
Tem perature Characteristic ±0.1%/°C
Accessories Carrying Case
Weight 0.7 Pounds
SAVE THIS MANU AL
You will need this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures, parts list and assembly
diagram. Keep your invoice with this manual. Write the invoice number on the inside of
the front cover. Keep this manual and invoice in a safe and dry place for future reference.
UNPACKING
When unpacking, check to make sure all the parts shown in this manual and the
carrying case are included. If any parts are missing or broken, please call Harbor F reight
Tools at the number shown on the cover of this manual as soon as possible.
GENERAL SAFETY WARNINGS AND PRECAUTIONS
1.Check for damaged parts. Before using this product, carefully check that it will
operate properly and perform its intended function. Check for damaged parts and
any other conditions that may affect the operation of this product.
NOTE:Individual replacement parts are not av ailab le for this product.
2.Maintain this product with care. Keep this product clean and dry when in use and
during storage for better product performance. Ser vice and maintenance should
be performed regularly by a qualified technician. When in use , the Photo Detector
(5) (white sphere) must be kept clean.
SKU 91194P A GE 2
Page 3
3.Use the right product for the job. There are cer tain applications for which this
product was designed. Do not modify this product, and do not use this product for
a purpose for which it was not intended.
4.Maintain labels and nameplates on this product. These carry impor tant infor-
mation. If unreadable or missing, contact Harbor Freight Tools for a replacement.
5.Do not use this product in excessive heat and humidity conditions.
6.Do not allow children to handle this product. This product is constr ucted with
small parts that may pose a serious choking hazard if swallowed.
7.WARNING! The warnings, precautions, and instructions discussed in this manual
cannot cover all possible conditions and situations that may occur. The operator
must understand that common sense and caution are factors, which cannot be b uilt
into this product, but must be supplied b y the operator.
OPERATING INSTRUCTIONS
NOTE: For additional references to the parts listed in the following pages refer to
Figure A, below.
PHOTO DETECTOR (5)
LCD DISPLAY (1)
POWER SWITCH (2)
RANGE SELECTION SWITCH (3)
DATA HOLD SWITCH (4)
FIGURE A
1.Press the Power Switch (2) to turn the Light Meter “ON”. Press the Power Switch
again to turn the Light Meter “OFF”. (See Figure A.)
2.Press the Range Selection Switch (3) to select between the ranges of 1 ~ 2,000/
20,000/50,000(200,000) Lux. At the same time, the LCD Display (1) will indicate
the value by which to multiply to receive the correct value. (See Figure A.)
SKU 91194PAGE 3
Page 4
3.Face the Photo Detector (5) in a horizontal position toward the light source.
(See Figure A, previous page.)
4.Read the number on the LCD Display (1). If the LCD Display only shows “1”, the
input signal is too strong and a higher measuring range should be selected.
(See Figure A.)
5.Press the Data Hold Switch (4) and “H” will illuminate on the LCD Display (1). The
most recent value will continue to show on the LCD until the Power Switch (2) is
pressed or the Data Hold Switch is pressed again. (See Figure A.)
6.After completing the measurement, make sure the Light Meter is turned “OFF” and
the Photo Detector (5) is covered. Then, store the unit in its Carrying Case.
(See Figure A.)
TO REPLACE THE BATTERY
When the 9 volt Battery (not included) becomes low, the letters “BT”
will illuminate on the LCD Display (1). To replace the Battery, remove the
Screw on the Battery Compar tment Door located on the back of the Light
Meter. Then remov e the Battery Compartment Door by sliding it down. Remove the old Battery. Install a ne w 9 v olt Battery. Then, replace the Battery
Compartment Door and the Screw. (See Figure B.)
BATTERY
COMPARTMENT
DOOR
SKU 91194P A GE 4
REAR VIEW
SCREW
FIGURE B
Page 5
SPECTRAL SENSITIVITY CHARACTERISTICS
RELATIVE
SENSITIVITY
(%)
INSPECTION, MAINTENANCE, AND CLEANING
100
80
60
40
20
0
SPECTRAL SENSITIVITY
400500600
WAVELENGTH (nm)
-V(r)
LIGHT
METER
700
FIGURE C
1.Before each use, inspect the general condition of the Light Meter. Check f or broken, loose or missing parts; low Battery; any condition that may affect the proper
operation of the product. If a problem occurs, have the problem corrected before
further use. Do not use damaged equipment.
2.Do not use abrasives or solvents to clean this product.
Please Note:
While the manufacturer has made every effort to ensure this is a
reliable and accurate tool, neither Harbor Freight Tools nor the manufacturer can be held responsible for any errors in lighting placement/
adjustment; the costs of any wasted film, time, etc.; or any other costs
incidental to any errors in measurement.
NOTE: No individual replacement parts are available for this product.
SKU 91194PAGE 5
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.