Harbor Freight Tools 69677 Owner's Manual

Table of Contents
Safety ......................................................... 2
Setup .......................................................... 6
Specications ............................................. 6
SAFETY OPERATION MAINTENANCESETUP
Operation .................................................... 9
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Maintenance .............................................. 15
Parts List and Diagram .............................. 20
Warranty .................................................... 23
Obey all safety messages that follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
Addresses practices not related to personal injury.
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING – When using tools, basic precautions should always be followed, including the following:
Set up Precautions
1. Gasoline fuel and fumes are ammable, and
potentially explosive. Use proper fuel storage and handling procedures. Do not store fuel
or other ammable materials nearby.
2. Have multiple ABC class re extinguishers nearby.
3. Operation of this equipment may create sparks
that can start res around dry vegetation. A spark
arrestor may be required. The operator should
contact local re agencies for laws or regulations relating to re prevention requirements.
4. Set up and use only on a at, level,
well-ventilated surface.
5. All connections and conduits from the Generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable.
6. Connections for standby power to a building
electrical system must be made by a qualied
electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
7. Wear ANSI-approved safety goggles, heavy-duty work gloves, and dust mask/respirator during set up.
8. Use only lubricants and fuel recommended in this manual.
Page 2
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Item 69671 / 69677
Set up Precautions (cont.)
9. Improper connections to a building electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage, and the generator may explode, burn, or
cause res when utility power is restored. Consult the utility company and a qualied electrician if
intending to use the generator for back up power.
Operating Precautions
1. CARBON MONOXIDE HAZARD
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
10. Do not operate the Generator before grounding. The Generator must be earth-grounded in accordance with all relevant electrical codes and standards before operation.
SAFETYOPERATIONMAINTENANCE SETUP
7. Fire Hazard! Do not ll gas tank while engine is running. Do not operate if gasoline has been spilled. Clean spilled gasoline before starting engine.
Do not operate near pilot light or open ame.
8. Do not touch engine during use. Let engine cool down after use.
9. Never store fuel or other ammable materials near the engine.
10. If the plugged in product operates abnormally or unusually slow, immediately stop using the generator as a power source. Always read and adhere to the instruction manual of the product to be powered, to make sure that it can be safely
and efciently powered by a portable generator.
Only use OUTSIDE and far away from windows, doors, and vents.
2. Never use a generator indoors, including in garages, basements, crawlspaces and sheds. Opening doors and windows or using fans will NOT prevent carbon monoxide build up in the home.
3. When using generators, keep them outdoors and far away from open doors, windows, and vents to avoid toxic levels of carbon monoxide from building up indoors.
4. If you start to feel sick, dizzy, or weak while using a generator, get to fresh air right away. The carbon monoxide from generators can quickly lead to full incapacitation and death.
5. Keep children away from the equipment, especially while it is operating.
6. Keep all spectators at least six feet from the Engine during operation.
11. Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock.
12. Do not exceed the maximum power rating of the generator. Make sure that the total electrical rating of the all of the tools or appliances plugged into the generator at the same time does not exceed that of the generator. Check that the startup surge will not be beyond the limit of the Generator. Power levels between rated and maximum may be used for no more than 30 minutes.
13. Avoid substantially overloading which will trip the circuit breaker. Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker or circuit protector OFF, but will shorten the service life of the generator.
14. Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground.
15. Do not touch electrically energized parts of the Generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object.
Item 69671 / 69677
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Page 3
16. Connect the Generator only to a load or electrical system (120 volt or 240 volt) that is compatible with the electrical characteristics and rated capacities of the Generator.
17. Insulate all connections and disconnected wires.
SAFETY OPERATION MAINTENANCESETUP
18. Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators.
29. Stay alert, watch what you are doing and use common sense when operating this piece of equipment. Do not use this piece of
equipment while tired or under the inuence
of drugs, alcohol or medication.
30. Dress properly. Do not wear loose clothing or jewelry. Keep hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
19. Only use a suitable means of transport and
lifting devices with sufcient weight bearing
capacity when transporting the generator.
20. Secure the Generator on transport vehicles to prevent the tool from rolling, slipping, and tilting.
21. Industrial applications must follow OSHA requirements.
22. Do not leave the Generator unattended when it is running. Turn off the Generator (and remove safety keys, if available) before leaving the work area.
23. The Generator engine can produce high noise levels. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Always wear ear protection when operating or working around the gas engine while it is operating.
24. Wear ANSI-approved safety glasses, hearing protection, and NIOSH-approved dust mask/respirator during use.
25. People with pacemakers should consult their
physician(s) before use. Electromagnetic elds
in close proximity to a heart pacemaker could cause pacemaker interference or pacemaker failure. Caution is necessary when near the engine’s magneto or recoil starter.
26. Use only accessories that are recommended by Harbor Freight Tools for your model. Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment.
27. Do not operate in explosive atmospheres,
such as in the presence of ammable
liquids, gases, or dust. Gasoline-powered engines may ignite the dust or fumes.
28. Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and connections to avoid sparking or arcing. These events could ignite fumes or vapors.
31. Parts, especially exhaust system components, get very hot during use. Stay clear of hot parts.
32. Do not cover the generator or its engine during operation.
33. Keep the generator, its engine, and surrounding area clean at all times.
34. Use the generator, accessories, etc., in accordance with these instructions and in the manner intended for the particular type of equipment, taking into account the working conditions and the work to be performed. Use of the equipment for operations different from those intended could result in a hazardous situation.
35. Do not operate the generator with known leaks in the engine’s fuel system.
36. This product contains or, when used, produces a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code § 25249.5, et seq.)
37. When spills of fuel or oil occur, they must be
cleaned up immediately. Dispose of uids and
cleaning materials as per any local, state, or federal codes and regulations. Store oil rags in a bottom-ventilated, covered, metal container.
38. Keep hands and feet away from moving parts. Do not reach over or across generator while operating.
39. Before use, check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator’s operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained equipment.
40. Use the correct generator for the application. Do not modify the generator or its engine, and do not use the generator for a purpose for which it is not intended.
Page 4
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Item 69671 / 69677
Service Precautions
1. Before service, maintenance, or cleaning:
a. Unplug all devices from the generator.
b. Turn the engine switch to its “OFF” position.
c. Allow the engine to completely cool.
d. Then, remove the spark plug
cap from the spark plug.
2. Keep all safety guards in place and in proper working order. Safety guards include
mufer, air cleaner, mechanical guards,
and heat shields, among other guards.
3. Make sure the Engine Switch is in its “OFF” position before moving the Generator and before performing any service, maintenance, or cleaning procedures on the unit.
4. Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight.
5. Do not alter or adjust any part of the
equipment or its engine that is sealed by the
manufacturer or distributor. Only a qualied
service technician may adjust parts that may increase or decrease governed engine speed.
6. Wear ANSI-approved safety goggles, heavy-duty work gloves, and dust mask/respirator during service.
7. Maintain labels and nameplates on the equipment. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement.
8. Have the equipment serviced by a qualied repair
person using only identical replacement parts. This will ensure that the safety of the equipment is maintained. Do not attempt any service or maintenance procedures not explained in this manual or any procedures that you are uncertain about your ability to perform safely or correctly.
9. Store equipment out of the reach of children.
10. Follow scheduled engine and equipment maintenance.
Refueling:
1. Do not smoke, or allow sparks, ames, or other sources of ignition around the equipment, especially when refuelling.
2. Do not rell the fuel tank while the engine is running or hot.
3. TO PREVENT FUEL LEAKAGE AND FIRE
HAZARD, Do not overll with fuel. Fill with fuel according to the Fuel Level information
below the Specication chart for your model.
4. Do not ll fuel tank to the top. Leave a little room for the fuel to expand as needed.
5. Refuel in a well-ventilated area only.
6. Wipe up any spilled fuel and allow excess to evaporate before starting engine. To
prevent FIRE, do not start the engine while the smell of fuel hangs in the air.
SAVE THESE
SAFETYOPERATIONMAINTENANCE SETUP
Item 69671 / 69677
INSTRUCTIONS.
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Page 5
Functional Description
Specications
SAFETY OPERATION MAINTENANCESETUP
Rated Output
Battery needed for electric start
Generator
Engine
Item 69677 - The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information, refer to the last pages of this manual.
Item 69671 - The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental Protection Agency. For warranty information, refer to the last pages of this manual.
(not included)
Electrical Receptacle
Displacement 420cc Engine Type Horizontal Single Cylinder 4 stroke OHV Cooling System Forced air cooled
Fuel
Engine Oil
Run Time @ 50% load 12 hr. Operational Volume 76 dB
Available accessories Wheel kit (sold separately)
Type 87+ octane unleaded gasoline Capacity 6.1 Gallons (23L)
Type SAE
Capacity 1.16 Quart (1.1L)
120/240V~, 60Hz 7,000 Watts (8750 max)
12V, lead acid, 9Ah
Two 3-Prong, duplex NEMA #5-20 120V One 3-Prong, NEMA #L5-20 twistlock 120V One 4-Prong, NEMA #L14-30 twistlock 120V/240V One DC Outlet 12VDC
10W-30 above 32° F 5W-30 at 32° F or below
Components and Controls
Fuel Cap
Fuel Valve
Choke
Air Filter
Frame
Starter
Handle
DC Receptacle
DC Circuit Breaker
AC Circuit Breakers
AC Receptacles
Ground Terminal
Power Switch
Low Oil Indicator
Page 6
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Item 69671 / 69677
Components and Controls (cont.)
START
The following are descriptions of the controls on the power panel. Your generator has sockets to power your products with circuit
breakers to protect the voltage ow.
I
O
1.
Engine Switch: Used to start and stop the Engine.
2. AC Receptacles: The Generator contains several AC Receptacles to power tools and equipment.
a. 3-Prong, duplex
120 volt receptacle (NEMA #5-20)
ON
OFF
3.
Circuit Breakers: The circuit breaker protects the Generator from overloading. The rating of the breaker and the load it protects are marked near the breaker. Should any of the Circuit Breakers trip, the Generator will stop the electricity output. If this happens, unplug all loads from the Generator. Allow the Generator to cool down. Then, press the tripped Circuit Breaker, restart the Engine, and re-attach loads.
4. 12 VDC Receptacle: 12 VDC Receptacle provides a power source for 12 volt DC items.
5. Grounding Terminal: Prior to each use, set up the ground wire (not included) connection to the Grounding Terminal to properly ground the Generator. See Set up instructions to properly ground the Generator.
SAFETYOPERATIONMAINTENANCE SETUP
b. 3-Prong, twistlock,
120 volt receptacle (NEMA #L5-20)
c. 4-Prong, twistlock,
120/240 volt receptacle (NEMA #L14-30)
WARNING! Connect tools and equipment
only to the Receptacle (120 volt or 240 volt) that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used.
Item 69671 / 69677
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Page 7
Initial Tool Set Up/Assembly
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
SAFETY OPERATION MAINTENANCESETUP
Note: For additional information regarding the parts listed in the following pages,
refer to the Assembly Diagram near the end of this manual.
TO PREVENT SERIOUS INJURY: Operate only with proper spark arrestor installed.
Operation of this equipment may create sparks that can start res around dry vegetation. A spark arrestor may be required.
The operator should contact local re agencies for laws or regulations relating to re prevention requirements.
At high altitudes, the engine’s carburetor, governor, and any other parts that control the fuel-air ratio will
need to be adjusted by a qualied mechanic to allow efcient high-altitude use and to prevent damage to the
engine and any other devices used with this product.
CAUTION: This generator is not intended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector (both not included). Sensitive electronic equipment includes,
but is not limited to, audio/video equipment, some television sets, computers, and printers. Sensitive
electronic equipment should be operated on approved inverter type generators or pure sine wave generators.
Note: Wheel Kit, item # 68531 (sold separately) can be used with this generator.
Battery Setup Instructions
All Generators can be started using the recoil method. Generators with the electric start option require installation of a battery to operate the electric start feature. Connect the battery to the generator engine:
1. Place a fully charged, lead-acid 12 V, 9 Ah battery (not included) in the battery holder on the generator.
2. Bolt in place using the hardware included with the battery.
Negative
Connector
Positive
Connector
Battery
Hardware
3. Attach the positive (red) cable connector from the engine to the Positive Terminal on the battery. Connect cable securely to prevent disconnection and short circuits.
4. Attach the negative (black) cable connector to the negative battery terminal.
Grounding
The Generator must be properly grounded before
use. Have the unit grounded by a qualied electrician if you are not qualied to do so.
To ground the Generator, connect a #6 AWG grounding wire (not included) from the Grounding Terminal on the Control Panel to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the Generator.
Page 8
For Generator technical questions, please call 1-800-444-3353.
For Engine technical questions, please call 1-800-520-0882.
Item 69671 / 69677