Harbor Freight Tools 69303 Owner's Manual

Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating,
inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.
ITEM 69303
Visit our website at: http://www.harborfreight.com
Email our technical support at: tech@harborfreight.com
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-800-444-3353 as soon as possible.
Copyright© 2011 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.
Before start-up, note the following:
CAUTION
The pump can be connected to any shock-proof plug which has been installed according to regulations. The plug must have a supply voltage of 120 V~ at 60 Hz.
WARNING
IMPORTANT! For your own safety – before starting to run the pump, please have the following items checked by an expert:
1. Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, connect only to a properly grounded, grounding-type receptacle.
2. Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
3. The electrical connections must be protected from moisture.
4. If there is danger of flooding, the electrical connections must be taken to higher ground.
5. Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
6. The pump must be protected from frost.
This pump has been evaluated for use with water only.
13. Do not operate Pump on earth, clay or sand surfaces.
14. Do not allow the Motor to get wet.
15. Wear non-skid rubber boots when any water is on the floor.
16. Inspect insulation regularly; do not use if insulation damaged.
17. Use indoors only.
18. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure. In addition, people with pacemakers should:
• Properly maintain and inspect to avoid electrical shock.
• Any power cord must be properly
grounded. Ground Fault Circuit Interrupter (GFCI) should also be implemented – it prevents sustained electrical shock.
7. The pump must be protected from running dry.
8. This product is not a toy. Keep it out of reach of children. Access by children should also be prevented with appropriate measures.
9. WARNING: Handling the Power Cord on this product will expose you to lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health & Safety Code § 25249.5, et seq.)
10. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
11. Do not use with swimming pools or marine areas.
12. Do not use extension cords with this Pump.
19. Secure the intake and discharge pipes (not included) to a solid surface to ensure the stability of the Pump.
20. When connecting intake and discharge pipes to Pump, use thread tape (not included) and securely fasten pipes in place.
21. Mount the Pump on a flat, level surface before use.
22. Prior to use, and periodically thereafter, check to make sure all connections are tight and secure.
Fluid Type
The Pump is designed for use with water with a maximum temperature of 77° F (25°C). Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Page 2 For technical questions, please call 1-800-444-3353. Item 69303
Specifications
Electrical Rating 120V~ / 60Hz / 10 A Inlet / Outlet Diameter 1 IN. NPT Maximum Flow 976 GPH Maximum Suction Lift 26 FT. Maximum Delivery Height 150 FT. Start Pressure 22 PSI Stop Pressure 65 PSI Power Cord Length 6 FT.
Installation
Note: Do not install the pump by suspending it unsupported from its power cord or discharge hose.
The pump must be suspended from the handle. Remove Shipping Plug before installation.
Installing
1. Thread the Pressure Control Box onto the water outlet on the top of the Pump.
2. Set the Pump horizontally on a level, solid and dry foundation.
3. Secure the Pump to the mounting surface by installing bolts (not included) through the mounting holes in the base plate.
4. The Pump is supplied with 1" NPT connections to be fitted in the suction and discharge ports. See Figure 1.
5. If the Pump is installed with long pipes (as shown), the pipes must be properly supported on either side of the Pump to prevent straining the connections. If the Pump is drawing water from a well, fit a foot valve (not included) to the end of the suction pipe.
WARNING! Do not allow the Pump to get wet.
Note: The maximum delivery height
of the Pump is 32 feet.
Page 3For technical questions, please call 1-800-444-3353.Item 69303
Loading...
+ 5 hidden pages