1.4 Liter Ultrasonic Humidier
Item 68758
INSTRUCTIONS AND PRECAUTIONS
Visit our website at: http://www.harborfreight.com
Email our tech support at: tech@harborfreight.com
Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.
When unpacking, make sure that the product is intact and undamaged.
If any parts are missing or broken,
please call 1-800-444-3353 as soon as possible.
Copyright© 2011 by Harbor Freight Tools®. All rights reserved. No portion of this document or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this document may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.
For technical questions or replacement parts, please call 800-444-3353.
Page 2
Page 2 For technical questions, please call 1-800-444-3353. SKU 68758
Specications
Electrical Requirements 120V~60Hz, 25W
Water Tank Capacity 47 OZ. (1.4 L.)
3077984
Important Safety Information
Precautions
1. This product is not a toy. Do not allow children to play with or near this item.
2. Use as intended only.
3. Do not abuse the cord. Never use the cord for carrying, pulling
or unplugging the Humidier.
Keep cord away from heat, oil, sharp edges or moving parts.
4. Use a Ground Fault Circuit Interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock.
5. Do not use without water in the water tank. Distilled water is recommended.
6. Do not add medication, fragrance or oil to the water. It will cause the machine to malfunction and void the warranty.
7. Do not cover or insert anything into any openings on the unit.
8. Do not tilt, tip or attempt to empty
or ll unit while in operation.
9. Do not leave unit unattended in closed rooms.
10. To protect against electric shock, do not immerse unit, plug or cord in water or other liquids.
11. Do not direct mist nozzle at children, animals, walls or furniture.
12. Do not operate unit in the presence
of explosive or ammable fumes.
13. Do not place the Humidier or any parts near an open
ame, cooking appliance or
other heating appliance.
14. Do not operate Humidier with a damaged cord or plug, or if the product malfunctions or has been dropped or damaged in any manner.
15. Do not use with any attachments not recommended by the manufacturer.
16. Inspect before every use; do not use if parts are loose or damaged.
17. Maintain product labels and nameplates. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.
Page 3
Page 3For technical questions, please call 1-800-444-3353.SKU 68758
Grounding
TO PREVENT ELECTRIC SHOCK
AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION:
Check with a qualied
electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not
t the outlet, have a proper
outlet installed by a
qualied electrician.
Double Insulated Tools: Tools with Two Prong Plugs
Outlets for 2-Prong Plug
1. Tools marked “Double Insulated” do not require grounding. They
have a special double insulation
system which satises OSHA
requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code.
2. Double insulated tools may be used in either of the 120 volt outlets shown in the preceding illustration.
(See Outlets for 2-Prong Plug.)
Extension Cords
1. Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.
2. As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.
(See Table A on page 4.)
3. The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)
4. When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)
5. If you are using one extension cord for more than one item, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)
Page 4
Page 4 For technical questions, please call 1-800-444-3353. SKU 68758
6. If you are using an extension cord outdoors, make sure it is
marked with the sufx “W-A”
(“W” in Canada) to indicate it is acceptable for outdoor use.
7. Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or
have it repaired by a qualied
electrician before using it.
8. Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.
TABLE A: RECOMMENDED MINIMUM
WIRE GAUGE FOR EXTENSION CORDS*
(120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25´ 50´ 75´ 100´ 150´
0 – 2.0 18 18 18 18 16
2.1 – 3.4 18 18 18 16 14
3.5 – 5.0 18 18 16 14 12
5.1 – 7.0 18 16 14 12 12
7.1 – 12.0 18 14 12 10 -
12.1 – 16.0 14 12 10 - -
16.1 – 20.0 12 10 - - -
* Based on limiting the line voltage drop to ve volts at
150% of the rated amperes.
Operating Instructions
Read the ENTIRE
IMPORTANT SAFETY INFORMATION section at the beginning of this document including all text under subheadings therein before set up or use of this product.
Operation
Mist Nozzle
Power Switch /
Mist Intensity
Control
Water Tank
Power
Indicator
Light
1. Remove the Water Tank
by grasping the Tank rmly
and pulling upwards.
2. Turn the Water Tank over and turn the cap counterclockwise to open. Fill with cool tap water or distilled water. Do not use hot water. Do not add fragrance or oil
Page 5
Page 5For technical questions, please call 1-800-444-3353.SKU 68758
or medication to the water. It will cause the unit to malfunction.
Note: Distilled water is recommended.
3. Replace the ll cap and turn clockwise to tighten. Do not over tighten.
4. Set the Water Tank back in place, making sure that the Tank is correctly aligned with
the body of the Humidier.
5. Plug the unit into a 120V outlet.
6. Turn the Power Switch clockwise to turn on the unit.
7. Adjust the mist intensity by continuing to turn the Power Switch clockwise.
8. Once the Water Tank is in place, do not attempt to pick up or
move the Humidier. If you need to move the Humidier, unplug
the unit and drain the water from the base before moving.
9. Pay attention to the water level, adding more water when the level is low.
10. To eliminate excessive humidity, especially in smaller rooms, leave the room door open and adjust the Mist Intensity Control.
Note: It is best to keep the humidity
level between 30 and 50 percent. The comfort level of humidity will vary from room to room and with changing room conditions. In cold weather, windows and walls may fog from excessive indoor humidity. Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow.
Automatic Shut-off
The Humidier is equipped with
an automatic shut-off feature. If the unit runs dry and the unit becomes hot, the unit will stop working. If this happens, turn off
and unplug the Humidier. Let the unit cool down, then rell with
water and plug in to an outlet. Turn on to resume operation.
Do not run the Humidier
without water in the reservoir.
Page 6
Page 6 For technical questions, please call 1-800-444-3353. SKU 68758
Maintenance & Service
Procedures not specically
explained in this manual must be performed only
by a qualied technician.
To prevent serious injury from accidental operation: Turn the Power Switch off and unplug the unit from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
To prevent serious injury from tool failure: Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
Cleaning, Maintenance, and Lubrication
1. BEFORE EACH USE, inspect the
general condition of the Humidier.
Check for loose hardware, misalignment of parts, cracked or broken parts, damaged electrical wiring, and any other condition that may affect its safe operation.
2. AFTER USE, wipe surfaces dry with a clean cloth.
3.
WARNING! If the supply cord
of this Humidier is damaged,
it must be replaced only by a
qualied service technician.
Cleaning
Nebulizer
Sensor
Keep the Nebulizer and Water Sensor free of mineral deposits. To clean them, remove the Water Tank, empty the Reservoir and clean both areas with a soft brush (not included). Do not scrape the Nebulizer or Sensor. Do not use metal tools to clean unit.
If the Water Tank is extremely dirty, soak with a mild bleach and water solution, then rinse and dry with a soft cloth. Do not use detergent.
Do not leave water in the tank for a long period of time as bacterial growth may develop. Clean and dry the unit after every use.
Storage
1. Save the box for off-season storage.
2. Clean the tank, reservoir and all parts thoroughly. Dry before storage.
3. Leave the cap of the Water Tank loose to prevent the cap and gasket from sticking together and to prolong the life of the gasket.
Page 7
Page 7For technical questions, please call 1-800-444-3353.SKU 68758
Note: If water is left in the unit during storage, it may harden and
leave deposits that may affect operation of the unit.
Troubleshooting
If the Humidier is not producing mist:
Problem Solution
Unit not plugged in. Turn the Power Switch off, and plug in if needed.
Turn the power switch back on to resume operation. Unit not turned on. Turn on and adjust level. No water in the Tank. If the Tank is empty, turn off and unplug the
unit. Let it cool down, then rell with water.
Plug in and turn on to resume operation.
Water level too high. If the water level is blocking the Mist Nozzle,
turn off and unplug the unit. Empty some of the
water out of the Tank. Then resume usage.
Water Tank not properly seated onto the body of the unit.
If it is not seated properly, turn off and unplug
the unit. Adjust the Water Tank, then plug the
unit back in. Turn it on to resume operation.
Page 8
Page 8 For technical questions, please call 1-800-444-3353. SKU 68758
PLEASE READ THE FOLLOWING CAREFULLY
NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Record Serial Number Here:
Note: If product has no serial number, record
month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes
only, and are not available individually as replacement parts.