Harbor Freight Tools 62508 Owner's Manual & Safety Instructions

Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.
Copyright© 2014 by Harbor Freight Tools®. All rights reserved.
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating,
inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference.
Owner’s Manual & Safety Instructions
Do not use for potable water.
Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
ITEM 62508
REV 14l
Page 2 For technical questions, please call 1-888-866-5797. Item 62508
Before start-up, note the following:
The pump can be connected to any shock-proof plug which has been installed according to regulations. The plug must have a supply voltage of 120 VAC at 60 Hz.
CAUTION
This pump has been evaluated for use with clear water only.
WARNING
IMPORTANT! For your own safety – before starting to run the pump, please have the following items checked by an expert:
1. Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
2. Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
3. The electrical connections must be protected from moisture.
4. If there is danger of flooding, the electrical connections must be taken to higher ground.
5. Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
6. The pump must be protected from frost.
7. The pump must be protected from running dry.
8. Access by children should also be prevented with appropriate measures.
9. Do not use for potable water.
This item is not lead-free. No person may use any pipe, any pipe or plumbing
fitting or fixture, any solder, or any flux, in the installation or repair of any public water system or any plumbing in a residential or nonresidential facility providing water for human consumption that is not lead-free.
10. WARNING: The cord of this product contains lead and/or di (2-ethylhexyl) phthalate (DEHP), chemicals known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health & Safety Code § 25249.5, et seq.)
11. WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code § 25249.5, et seq.)
12. Install only on a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI).
13. When connecting inlet and outlet pipes to Pump, use thread tape (not included) and securely fasten pipes in place.
14. Mount the Pump on a flat, level surface before use.
15. Prior to use, and periodically thereafter, check to make sure all connections are tight and secure.
16. Do not use with swimming pools or marine areas.
17. Do not use extension cords with this Pump.
18. Do not operate Pump on earth, clay or sand surfaces.
19. Do not allow the Motor to get wet.
20. Wear non-skid rubber boots when any water is on the floor.
21. DO NOT IMMERSE IN WATER. This is not a submersible pump. Use indoors and outdoors.
22. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
23. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
Fluid Type
The Pump is designed for use with clear water with a maximum temperature of 95°F (35°C). Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Page 3For technical questions, please call 1-888-866-5797.Item 62508
Specifications
Electrical Rating 120VAC / 60Hz / 5A Inlet / Outlet Diameter 1" - NPT Maximum Pressure 50 PSI Maximum Flow 550 GPH Maximum Suction Lift 23' Maximum Delivery Height 110' Maximum Water Temperature 95°F (35°C) Maximum Ambient Temperature 104°F (40°C) Power Cord Length 6'
3065430
Page 4 For technical questions, please call 1-888-866-5797. Item 62508
Functions
Inlet
Outlet
Priming
Plug
Power Cord (not shown)
Figure A
Loading...