WATER PURITY
®
TEST PEN
Model 03106
ASSEMBLY and OPERATING INSTRUCTIONS
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at http://www.harborfreight.com
Copyright © 2002 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools .
For technical questions and replacement parts,
please call 1-800-444-3353
Specifications
Test Data Error +/- 5% Response Time Approx. 1 second Recovery Time Approx. 2 seconds Internal Battery Life Approx. 3 years Waterproof To 3 meters Operating Temperature 41 to 122 degrees fahrenheit Weight 1.2 ounces
WARNING: When using the product, basic safety precau­tions should always be followed to reduce the risk of per­sonal injury and damage to equipment.
Read all instructions before using this product!
#03106 Page 1
03106 water purity pen manual.p65 7/8/03, 9:47 AM1
Safety Warnings and Precautions
Safety Warnings and Precautions
1. Keep children away. Children must never be allowed in the work area. Do not let them handle the Purity Pen or the test water. It is a delicate instrument that breaks easily.
2. Use the right product for the job. There are certain applications for which this product was designed. Do not modify this product and do not use this product for a purpose for which it was not intended. This product is designed as a portable tester for homeowner water testing. It is not designed for commercial applications with toxic or contaminated waters.
3. Use eye protection. Always wear ANSI approved impact safety goggles when working with tools and equipment.
Warning: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible condi­tions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be sup­plied by the operator.
Operation
Warning! Do not put the Purity Pen in boiling water, dirty water,
or solvents. Keep the tip clean and do not touch the tip other than cleaning it with a clean, lint free cloth. Do not knock, twist or pull the detector terminal. Do not short-circuit the two termi­nals of the detector; damage to the Test Pen could occur. Note: When this manual refers to “pure” water, it is referring to distilled water which the Purity Pen indicates at a value of 60 or below. Note: Do not use a metal container to test water. Only test a sample once, using only one Purity Pen. Failure to heed these warnings will cause innacurate test results. Note: To insure test precision, the temperature of the water to be tested should be the same as the ambient temperature. Make sure the detector is clean, and do not touch the detector. A glass of water should only be tested one time. Use another glass of water if another test is needed.
#03106 Page 2
03106 water purity pen manual.p65 7/8/03, 9:47 AM2
REV 07/03
See Assembly Drawing on page 4.
1. To insure precision results, try to test a water sample with the
same ambient temperature.
2. Take off the protective Sheath (#2).
3. Put no more than 1-1/2” of water in a sample cup.
4. Slide the switch to the “on” position and immediately let go of
the switch.
5. Wait until the display reads “------”. Then put the tip of the Pen
into the sample being careful not to let the metal tip touch the bottom of the container. Hold the pen vertical, in this position, for three seconds. The test results will be shown on the display.
6. Remove the Pen from the water and the display will return to
“------”. Slide the switch to the “on” position and immediately let go of the switch and the display will go blank. If you forget to turn it off, it will automatically go off in 3 seconds. Replace the protective Sheath (#2).
Note: Testing values listed on page 4.
Maintenance
1. Keep the tip clean by wiping it with a clean, lint free cloth.
2. Always store the Pen in its protective Sheath (#2).
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBU­TOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EX­PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACE­MENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LI­CENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACE­MENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
#03106 Page 3
03106 water purity pen manual.p65 7/8/03, 9:47 AM3
REV 07/03
Parts List
Part No. Description 1 Water Purity Test Pen 2 Pen Sheath
Diagram
1
Display
Metal Tip
2
Water Values:
0-60 = Pure water 60-200 = Drinkable water 200-300 = Only drinkable after boiling or using a filtration device Above 300 = Absolutely not drinkable water
Note: You may test other drinks (juice, milk, soda) and use the same scale as above. If you test a product once and then test another container of the same product, and get a different read­ing, it means the product with the highest value is deteriorating.
#03106 Page 4
03106 water purity pen manual.p65 7/8/03, 9:47 AM4
Loading...