Reviewthe following safetyprecautions carefullybefore operate the device to avoid anypersonalinjuries or damages to the device and anyproducts connected to it.Toavoid potentialhazards use the device asspecified bythis user’s guide only.
Onlyprofessionallyauthorizedpersonnelcan perform maintenance.Do notrun theproductwhenthe outer cover or panelis open.Do not operate with suspected failures.Ifsuspected damage occurs with the device,have
itinspected byqualified service personnelbefore further operations.
Do notoperate in wet/damp conditions.Do notuse in explosive environmentsKeep productsurfaces cleanand dry.Security warning:One should abide bythe relevantterms in the manualregarding safetyor
injuryto human bodyor damages to the product,as wellas operation or environmentwhichmayresultin testfailure.
Before the use,please read and understand the warning and safetyinformation mentioned in
this manual.
Use the instrumentaccording to the function specified in the manual.Ifthe component needs measurement,make sure the circuitis turned offand allcapacitorsin
the circuitare discharged before the measurement.
Before the measurement,components such as capacitors shallbe discharged.The lithiumbatteryof18650 or Type C-USBis used to provide power for the instrument.It
can be charged with Type C-USBport.
SafetySymbols
Warning:Remind the user to followthe operatingprocedures in the manual.
1
Environment
Please do notoperate the instrumentin the place thatis dusty,vibrative,underdirectsunlight
or where there is corrosive air.
The normalworking temperature is 0℃~40℃,relative humidity≤75%,so the instrument
should be used under above condition to guarantee the accuracy.
Please store the instrumentin the place where temperature is between 5℃and 40℃,
humidityis less than 85%RH.Ifthe instrumentwillnotbe putin use for a time,please have itproperlypacked with its originalbox or a similar box for storing.
The instrument,especiallythe testcable should befar fromstrong electro-magnetic field,to
avoid the jamming on measurement.
Use of Test Fixture
Please use the accessorytestfixture or cable together with your device.The testfixture made byuser or fromother companymaycause theincorrectmeasurementresult.The testfixture,cableand the pin ofDUTshould be keptclean, thus to guarantee the goodconnection between DUTand fixture.
Warm-up
Toguarantee the accurate measurement,the warm-up time is no less than 15min.Please notturn on or offinstrumentfrequently,in orderto avoid the inner datafluster.
General Check
When you have gota newLCR,itis suggested thatyou shouldperforma generalinspection onthe instrumentaccording to the following steps:
Check the shipping container for damage:Inspect the shipping container for damage after unpacking it.Itis notrecommended to power on
the instrumentin the caseofa damaged container.Check the accessories:Accessories supplied with the instrumentare listedin “Accessories”in this manual.Ifthecontents
are incomplete or damaged,please notifyour distributor atyour localarea orthe salesdepartment.
Check the instrument:In case there is anymechanicaldamage or defect,or the instrumentdoes notoperateproperly,
This handheld LCRmeteris used to measure inductance,capacitance,resistance and othercomponents ofthe parameters,smallsize,using7.4Vlithiumbatterypower supply,can beapplied to desktop applications,more mobile measurementand handheld measurementoccasions to provide greatconvenience.
Itprovides a resolution offour thousands digits for main parameters and a resolution of0.0001 forsecondaryparameter.Thehighest measurementfrequencyis 100kHz,and can measure the levelof0.6Vrms,0.3Vrms.Its automatic rangecan displaythe results in the fast,medium,or slowmode.Itcanautomaticallyselectthe appropriatemeasurementparameters according to thecharacteristics ofthe component.Themeasurementaccuracycan reach 0.25%.Itcombines theconvenience ofa handheld instrumentand good performance ofa table-type one.
The operationissimple and intuitive,and the testfrequency,parameters and speed can beselected immediately.Italso has a recording mode to assistin readingdata.Open circuitand shortcircuitcorrection function to improve the accuracyofmeasurement.Practicalconfigurationmenu can setbuzzer,automatic shutdown,language and other operations.
The instrumentis equipped with remote communication function and can be connected to PCvia Type C-USBcable for remote controland data acquisition.
3
Chapter 1 Overviewoffrontpanel
1.1Frontpanel
Description ofthe frontpanelis shown in the figure(Note:In this manual,long press meansholdingthe keyfor more than 2 seconds).
1.Display:2.8 inch TFTLCDscreen,which displayallfunctions ofthe instrument.
2.R-Xshortcut key:Selectthe mainparameter as Rand the secondaryparameter as Xdirectly.
3.C-Dshortcutkey:Selectthe mainparameter as Cand the secondaryparameter as Ddirectly.
4.L-Qshortcut key:Selectthe mainparameter as Land the secondaryparameter as Qdirectly.
5. Dataholdingrecordingkey:Turn on or offthedata holding function.
6. Frequencykey:Switch to fixedfrequencyquickly.
7.Rangekey:Switchtothe required rangequickly.You can selectAuto,10Ω,100Ω,1kΩ,10kΩ
and 100kΩ in turn.Auto is the automatic range,LCRwillautomaticallyselectthe appropriatehardware range according to the currenttested component,and theother rangesarethe fixedgear position.
8.Level shortcutkey: Switchto the fixedlevel(300mV,600mVRMS)quickly.
10.Mainparameterkey:Switchtothe main parametersquickly.You can selectAuto,R,L,C,Z
in turn.Auto is the function ofautomatic parameters.LCRselects the appropriate combination ofmain parameters and secondaryparameters according to the properties ofthe currenttestedcomponent.
11.Secondaryparameter key:Switchtothe secondaryparametersquickly.Ifthe main parameterselectas Auto, thiskeywillnotwork.
12.Equivalentmodekey:Switch equivalentbetween SERand PALquickly.Usershould selectthe equivalentmode according to testneed.
13.Setkey:Press the keytoenter the setting interface to setthe systemlanguage, automaticshutdown,displaybrightness,boot state and buzzer.Clickagainthe keyin the setting interface to viewthe device systeminformation. Clickagainitto return to the testinterface.
14.Arrowkeys:leftand rightarrowkeysto controlthemovementofthe cursor;up and downarrowkeys to selectthe parameter.
15.Power key:Press itto turn on or offthe instrument.
16.Data holdingrecordingkey:Press to turn on or offthe data holdingfunction.Press thekey
successivelycan switch functions ofMAX,MINand AVGin turn,and return to normaltestinterface after completingone cycle.Ifyou changethe main or secondaryparameter, it willexitthis function.Thefunction is disabled inautomatic parameters.
17.Relative and correctionmultifunctionalkey:Shortpress to turn on or offthe relative function,shortpressagainto exitthe relative value (REL) function.Long press to turn on thecorrection function.
18.Comparatorswitchand tolerancelimitsshortcutmultifunctionalkey:Long press toturn on or offthe comparator.Shortpress to quicklyswitch deviation tolerancelimit.
19.3-terminaltestjack
20.5-terminaltestnotch
Note:Pleaseseethelabel ontheadapterfor itsinputparameters;usethesuppliedadapter,or purchase the specifiedpower adapter from our company.The use of otheradapters may cause unnecessary damage.
Reminder:After connect theexternal powersupply,theinternalbattery power supplycircuitwillbeautomaticallycutoffand chargethebattery,
4.USBconnectionstate,displayed when itis connected to the PCand hidden atanyother time;Whenconnectedthe instrumentto the computerintheinitial,the USBiconiswhite,which
means thatthe USBis connected.Atthis time,the keyisstill availableandunlocked. Afterreceiving the firsteffective command,the USBicon becomes green, which means thatthe computer is communicated with the instrumentsuccessfully.The frontpanelbutton is unlockedafterUSBis pulled outor *GTLcommand is used.Then the USBicon turns white again and thebutton is available.
5.Measurementparametersettings
6.Batterypower icon:The remaining power is indicated.Please timelycharge the instrumentwhen the power is insufficient.
6
System settings interface
Complete
fiveterminal
testhole
Accessthree
terminaltest
hole
HI
LO
GUARD
On the systemsettings interface users can setthe language,auto power off,brightness,power setting and buzzer.And viewthe modeland versionofthe instrument.Press [SET] keyto enter the systemsetting interface,press the arrowkeyto selectthe settingoption and highlight,and press the arrowkeyfor specific setting.Then press the [SET] buttonagainto viewthe modeland version ofthe instrument.Press [SET]keyagainto exitthe system setting interface.
1.3Testport
TheserialLCRuses the3-terminaland 5-terminaltestports atthe same time,which is tocombine convenience andhigh accuracyfor the test.See the figure for the testterminal.
The three-terminaltestportofthe instrumentuses the standard rubberjack,therefore theinexpensive rubberplug-alligator clip can be used as the testline.Itis veryconvenientto applythe extended test,butthe drawbackislowtesting accuracy.
To improve the accuracyofthe testline when using the extension line,the LCRisalso equipped withthefive-terminaltestnotch for dedicated testfixture.Itrenders possible the completefour-terminalmeasurementofthe extension lineto ensure the high testing accuracy.
7