Installation Instructions / Warranty
3-Hole Roman Tub Rough
3-Hole Roman Tub Trim Kits
3-Hole Roman Tub Rough
06607000
Technical Information
Recommended water pressure 45-80 psi
Max. water pressure 145 psi
Recommended hot water temp. 10° - 140° F*
Max. hot water temp 165°F*
Hole size in mounting surface
valves 1¼"
spout 1⅜"
spout retaining pin ³⁄₁₆"
Max. mounting surface depth 1⁹⁄₁₆"
Max ow rate 10 gpm
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation Considerations
For best results, this unit should be installed by a licensed, professional plumber.
•
Large dierences in pressure between the hot and cold supplies should be balanced.
•
The included connecting tubes are type “K” copper tubing. If an installation dierent from the one
•
shown here is desired, the plumber may provide his own copper tubing.
To insure proper t of the trim, this valve must be installed after the mounting surface is nished and
•
made watertight.
This valve requires ½" hot and cold supply lines (not included)
•
The hot and cold water supplies should be ushed thoroughly before installation of this rough valve.
•
Damage to the cartridges caused by debris is not covered by the warranty.
Installation
Install the connecting tubes
Connect the valves to the spout tee using ⅜" compression ttings (included). Tighten the compression
ttings wrench tight.
Install the rough
Remove the plaster shield, spout adapter and gasket
from the spout tee.
If the mounting surface is unusually, thin, leave the white
plastic spacer in place. Otherwise, it may be removed
and discarded.
Insert the valves and spout tee through the mounting
surface.
Install the stop rings and escutcheon adapters on the
valves. When installed correctly, the stop rings will stop
the escutcheon adapters at the proper mounting height.
Lower the valves so that the escutcheon adapters rest on
the mounting surface.
Slide the spout adapter gasket over the spout tee,
aligning the hole in the gasket with the retaining pin hole
on the mounting surface.
Install the spout adapter.
The retaining pin on the bottom of the
adapter must go through the hole in the
mounting surface.
Tighten the mounting nuts and tensioning screws.
Install the plaster shields. Leave them in place until the
trim is installed.
3
Trim, 3-Hole Roman Tub Sets
Solaris 06630XX0
Stratos 06574XX0
Metro 06651000
Swing C Tango C Limbo C
Cross handle 061XX0 06045XX0 06109XX0
Scroll handle 0611XX0 06044XX0 06108XX0
Lever handle 0610XX0 06043XX0 06107XX0
These trim kits are for use with rough 06607000. The rough must be installed, and the mounting surface complete and watertight.
06630XX0 06574XX0 06651XX0
Swing C
cross handles shown
4
Tango C
scroll handles shown
Limbo C
lever handles shown