Installation Instructions / Warranty
Pharo
26310001
26311001
Pharo SideWay Showerpanel
Satin Chrome panel with Chrome trim 26310001
White panel with Chrome trim 26311001
Product Specification
Minimum incoming water pressure 21.75 psi
Recommended incoming water pressure 29 - 72 psi
Max. hot water temp 176oF*
Recommended hot water temp. 120oF - 140oF*
Max. flow rate handshower 2.5 gpm
bodysprays < 1 gpm each
Supplies 1/2” NPT hot and cold
Protection against back siphonage provided by check valves in handshower outlet, and in the hot
and cold supply elbows. The check valves should be removed and inspected yearly.
This showerpanel is for installation on a flat wall only. It is not possible to mount it in a corner.
*Know and follow all applicable local plumbing codes when setting the temperature on the water heater. In Massachussets,
the water heater may be set no higher than 112oF.
Necessary Tools for Installation (not included):
level
measuring device
grease pencil
8 mm drill bit
10, 22, and 24 mm wrenches
2 mm Allen wrench
mallet
waterproof sealant
pliers
Box Contents
Open the box carefully. Take care not to lose or
damage any of the component parts. Make sure
that all parts are present and are in good condition. If a component is missing or damaged,
contact Hansgrohe Technical Services.
3
Roughing in
Stub out for the hot and cold water supplies at the positions shown on the diagram. The 1/2”
NPT nipples should be long enough to extend 5/8” outside the surface of the finished wall.
Finish and seal the wall. The panel will hang on the finished wall.
Installation
Drill the screw holes at the positions shown using an 8 mm bit. Be careful not to drill into any
water lines!
Install the anchors. Seal the wall around the
anchors with waterproof sealant.
Seal the wall around the hot and cold nipples
with waterproof sealant. Wrap the nipples
with Teflon tape. Install the elbows so that the
outlets face downward.
Install the screws in the anchors. Install the
nuts so that the backs of the nuts are 5/8”
away from the finished wall.
Hang the panel from the top screws only. With a helper
holding the panel away from the wall, connect the panel supply hoses to the elbows.
Lift the panel up slightly. Push it back against the wall. Lower
the panel. The slots in the bottom of the panel should go over
the bottom screws.
Tighten the top and bottom nuts.
5
Place a rubber hose washer in one end of the handshower
hose. Screw this end of the hose to the handshower outlet on
the right side of the panel.
Place a screen washer in the other end of the hose. Screw
this end of the hose to the handshower.
Guide the handshower hose into place. Rest the handshower
in the holder.
Install the shelves and the top cover.
Justify the Handle:
Turn the handshower on.
Turn the temperature control handle until the output water
measures 100o on a thermometer.
Turn the handshower off. Do not move the tempera-
ture control handle.
Without turning it, remove the temperature control handle.
Remove the safety set. Reinstall it so that it is oriented as
shown in the diagram.
Reinstall the handle so that the safety stop override button is
at the 12:00 position. Install and tighten the handle screw.
Loosen the handle screw 1/4 - 1/2 turn. Install the screw
cover.
safety set
7
Adjust the Slider
Use a 2 mm Allen wrench to turn the slider adjustment screw.
Turn the screw counter-clockwise to make the slider easier to
move, clockwise to make it harder to move.
User Instructions