Technical Information
Recommended water pressure 14.7 - 72.5 psi
Minimum water pressure 29 psi
Max. water pressure 147 psi
Recommended hot water temp. 120� - 140� F*
Max. hot water temp 165�F*
Max. flow rate:
showerhead 2.5 gpm
handshower 2.5 gpm
neck spray 2.5 gpm
bodysprays 0.72 gpm each
Thermostatic temperature control
•
The high temperature limit stop on the thermostatic mx-
•
ing valve may be reset to comply with local plumbing
codes.
Protection against back siphonage provided by check
•
valves. The check valves should be removed and
inspected yearly.
This panel may be used with an instantaneous water
•
heater if the heater is at least 24 kW and the output is
at least 3 gpm @ 30 psi pressure. However, only one
panel function may be used at a time.
*Please know and follow all applicable local plumbing codes when setting
the temperature on the water heater. In Massachusetts, the water heater
may be set no higher than 112�F.
showerhead
neck spray
handshower
bodysprays
Installation Considerations
For best results, Hansgrohe recommends that this unit
•
be installed by a licensed, professional plumber.
Please read over these instructions thoroughly before
•
beginning installation. Make sure that you have all
tools and supplies needed to complete the installation.
A minimum of two people is required to install
•
this panel. Do not attempt to install this panel
alone as injury or damage to the panel may result.
foot rest
Suggested installation
Minimum ceiling height -- 86 5/8”
3
Package Contents
Please check the package contents before beginning installation. If parts are missing or are not in
good condition, please contact Hansgrohe Technical Service.
Rough-in
Install 1/2” NPT male nipples at the positions shown on the rough-in diagram for the hot and
•
cold water supplies.
The nipples should extend 5/8” outside the surface of the finished wall.
•
Install the finished wall surface. Make the wall watertight.
•
The showerpanel will hang on the finished wall.
•
The measurements shown on page 5 are for the suggested installation shown on page 3,
•
which is ideal for users of approximately 5’11” in height. The minimum ceiling height for this
installation is 86 5/8”.
The panel height may be increased if desired. The measurements shown on page 5 must be
•
increased accordingly, including the minimum ceiling height.
Thoroughly flush the hot and cold water supplies before installing the showerpanel.
•
Installation
Wrap the threads on the nipples with Teflon tape.
Install the elbows. The elbow outlets should face
downward.
Seal the wall around the elbows
with waterproof sealant.
Failure to seal the wall can lead
to possible water damage.
Drill the holes for the mounting screws with an 8 mm
bit.
Do not drill into water lines!
Install the anchors.
Seal the wall around the anchors
with waterproof sealant.
Failure to seal the wall can lead
to possible water damage.
Install the screws. Install the nuts. There should be
9/16” between the rear of the nut and the surface of
the wall.
1
3
5
2
4
Hang the panel over the top screws only (1).
With a partner holding the panel out of the
way, Install the panel supply hoses on the
elbows. Tighten the hose nuts. (2)
Raise the panel (3). Push the bottom of the
panel over the bottom screws (4). Lower the
panel (5) so that the screws are in the narrow
parts of the keyways.
7
Tighten the nuts using a 10 mm wrench.
Place a black rubber hose washer in one end
of the handshower hose. Install this end of the
hose on the handshower outlet.
Place the screen washer in the other end of
the hose. Connect this end of the hose to the
handshower.
Place the handshower in the holder.
Install the top cover.