WARRANTY
ORP HI 982401 is warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrode is warranted for a period of one year. This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner.
IST982401R3 05/05
Instruction Manual
R
(HI 982401)
On-line, Waterproof
ORP meter with Alarm
and appearance of its products without advance notice.
www.hannainst.com
Dear Customer, Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for a correct operation. Please read it carefully before using the meter.
If you need additional technical information, do not hesitate to e-mail us at tech@hannainst.com.
This instrument is in compliance with the
directives.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and ex­amine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center.
The meter is supplied with:
• Screwdriver
• 12 Vdc power adapter
Note: Conserve all packing material until the instrument has
been observed to function correctly. Any defective item must be returned in its original packing.
GENERAL DESCRIPTION
HI 982401 is an ORP meter specially designed to meet the needs of monitoring ORP such as in swimming pools. The housing has been completely sealed against
vapors and humidity with IP54 rating. Simply hang the above the sample to be monitored.
The HI 3214P/2 gel-filled ORP electrode (optional) is inter- changeable and the BNC connector is protected behind a waterproof sheath. The unique design of the electrode pro­vides longer life even in harsh conditions.
ACCESSORIES
HI 3214P/2 Double fiber junction, plastic body, Platinum
ORP electrode with 2 m (6.6’) cable and BNC connector
HI 7020M ORP test solution at 200/275 mV, 230 mL HI 7020L ORP test solution at 200/275 mV, 500 mL HI 7091M Reducing solution, 230 mL HI 7091L Reducing solution, 500 mL HI 7092M Oxidizing solution, 230 mL HI 7092L Oxidizing solution, 500 mL HI 7061L Electrode cleaning solution, 500 mL bottle HI 710005 12 Vdc power adapter, US plug HI 710006 12 Vdc power adapter, European plug HI 710012 12 Vdc power adapter, Australian plug HI 710013 12 Vdc power adapter, Southern Africa plug HI 710014 12 Vdc power adapter, UK plug
CE DECLARATION OF CONFORMITY
Recommendations for Users Before using this product, make sure that it is
entirely suitable for the environment in which it is used. Operation of this instrument in residen­tial areas could cause unacceptable interferences to radio and TV equipment.
During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharges.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC performance.
To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 Vac or 60 Vdc.
To avoid damages or burns, do not perform any measurement in microwave ovens.